Correlation of SODAR and Meteorological Tower Measurements. Prepared for: West Virginia Division of Energy

Similar documents
WIND DATA REPORT FOR THE YAKUTAT JULY 2004 APRIL 2005

WIND DATA REPORT. Vinalhaven

WIND DATA REPORT. Vinalhaven

Using Cell-Based VIL Density to Identify Severe-Hail Thunderstorms in the Central Appalachians and Middle Ohio Valley

Wind Resource Data Summary Cotal Area, Guam Data Summary and Transmittal for December 2011

Ohio Anemometer Loan Program (ALP) 3rd Quarter 2008 Progress Report

WIND DATA REPORT. Lynn, MA

Dennis: SODAR-Based Wind Resource Assessment

Site Description: Tower Site

Site Description: Tower Site

PRELIMINARY WIND RESOURCE ASSESSMENT OF WINDYGATES FIRST NATIONS PROJECT. Department of Innovation, Energy and Mines Contact. Rick Halas Document No

WIND DATA REPORT. Rockport School Complex Rockport, Massachusetts

Data Comparisons Y-12 West Tower Data

Introduction to Algebraic Expressions

WIND DATA REPORT. WBZ Tower, Hull, MA

WIND DATA REPORT. WBZ Tower, Hull, MA

COUNTY OF SONOMA PERMIT AND RESOURCE MANAGEMENT DEPARTMENT 2550 Ventura Avenue, Santa Rosa, CA (707) FAX (707)

WIND DATA REPORT DARTMOUTH, MA

WIND DATA REPORT. WBZ Tower, Hull, MA

Process Recommendations for Drift Reduction Technology Studies

Regional Haze Metrics Trends and HYSPLIT Trajectory Analyses. May 2017

(1) Verification Report: Johnson, C., (2010). Simandou Hills: Verification Study of high Resolution Modelling. Exeter: UK Meteorological Office.

WYANDOTTE MUNICIPAL SERVICES COMMUNITY WIND ENERGY PROJECT WIND RESOUCE SUMMARY

UPDATE #5 TO: A METHODOLOGY TO DETERMINE ANNUAL EFFECTIVENESS OF EMISSION MITIGATION TECHNIQUES IN THE ODSVRA

LONG TERM SITE WIND DATA QUARTERLY REPORT. Bishop and Clerks

Assessment of wind energy for Nevada using towers and mesoscale modeling

***When doing the lab report write-up, be sure to follow the guidelines.***

ODOR FOOTPRINTS AND THE ODOR FOOTPRINT TOOL

^_ Key Observation Point Viewshed Model. Grazing Yak Solar Project. Key Observation Point Location Map KOP #6 KOP #3 KOP #1 KOP #2 KOP #4 KOP #5

SONIC THERMOMETRY TODAY. W.R. Dagle and H.A. Zimmerman. Applied Technologies, Inc., Longmont, CO 80501

Increasing Transmission Capacities with Dynamic Monitoring Systems

This wind energy forecasting capability relies on an automated, desktop PC-based system which uses the Eta forecast model as the primary input.

WIND DATA REPORT. Dartmouth, MA

P5.3 EVALUATION OF WIND ALGORITHMS FOR REPORTING WIND SPEED AND GUST FOR USE IN AIR TRAFFIC CONTROL TOWERS. Thomas A. Seliga 1 and David A.

COOMALIE RIDGES RADIOMETRIC SURVEY, RUM JUNGLE AREA,

HURRICANE FRANCES CHARACTERISTICS and STORM TIDE EVALUATION

research highlight Wind-Rain Relationships in Southwestern British Columbia Introduction Methodology Figure 2 Lower Mainland meteorological stations

NC Streambed Mapping Project Issue Paper

Canal Velocity Indexing at Colorado River Indian Tribes (CRIT) Irrigation Project in Parker, Arizona using the SonTek Argonaut SL

WIND DATA REPORT. Savoy

Meteorological Data Collection, X/Q and D/Q, Critical Receptors

SOUTHERN CLIMATE MONITOR

Memorandum. Air Sampling

Notice on a Case Study on the Utilization of Wind Energy Potential on a Remote and Isolated Small Wastewater Treatment Plant

Monitoring Survey in the Vicinity of St. Marys Cement: Interim Report

Chapter 7 Mudflow Analysis

Colorado Front Range Wildfires Situation Report #7 Monday, July 02, :15 AM (MDT)

WeatherHawk Weather Station Protocol

WIND AND MOUNTAIN CLIMATOLOGY IN SEVERE ENVIRONMENTS UNIVERSITY OF MASSACHUSETTS CLIMATOLOGICAL RESEARCH IN THE WHITE MOUNTAINS, NH SELECTED

STRUCTURAL ENGINEERS ASSOCIATION OF OREGON

Review of Anemometer Calibration Standards

Vectors. An Introduction

DELINEATION OF A POTENTIAL GASEOUS ELEMENTAL MERCURY EMISSIONS SOURCE IN NORTHEASTERN NEW JERSEY SNJ-DEP-SR11-018

GC Briefing. Weather Sentinel Tropical Storm Michael. Status at 8 AM EDT (12 UTC) Today (NHC) Discussion. October 11, 2018

Controlled Environment Testing Report

Consumer Guide. Southwest Windpower 1801 W. Route 66 Flagstaff, AZ USA

Summary of Ohio Tornadoes

Uncertainty analysis of heliostat alignment at the Sandia solar field

SHADOW STUDY REPORT REGARDING

Chapter 7 Mudflow Analysis

WIND DATA REPORT. Rockport School Complex Rockport, Massachusetts

Memorandum. From: Erik Hale, Meteorology Group Assistant Manager Date: January 8, 2010 Re: NRG #40 Transfer Function Recommendation.

Planned Burn (PB)-Piedmont online version user guide. Climate, Ecosystem and Fire Applications (CEFA) Desert Research Institute (DRI) June 2017

Lesson 10.1 Assignment

HyMet Company. Streamflow and Energy Generation Forecasting Model Columbia River Basin

APPENDIX 3.6-A Support Information for Newcastle, Wyoming Meteorological Monitoring Site

9-3 Constant Rate of Change and Slope

2/18/2019. Position-versus-Time Graphs. Below is a motion diagram, made at 1 frame per minute, of a student walking to school.

Lab Topographic Maps. Name: Partner: Purpose. Background Information

Town of Chino Valley. Survey Control Network Report. mgfneerhg mc N. Willow Creek Road Prescott AZ

Chapter 2 Describing Change: Rates

NIDIS Intermountain West Drought Early Warning System December 11, 2018

Tornado Hazard Risk Analysis: A Report for Rutherford County Emergency Management Agency

Centralized Forecasting Registration and Communication Requirements for Distribution Connected Variable Generators. IESO Training

LOCAL CLIMATOLOGICAL DATA Monthly Summary July 2013

Tutorial 8 Raster Data Analysis

Hazus: Estimated Damage and Economic Losses. North Carolina and South Carolina United States

MAPPING THE RAINFALL EVENT FOR STORMWATER QUALITY CONTROL

Meteorological QA/QC

AERMOD Sensitivity to AERSURFACE Moisture Conditions and Temporal Resolution. Paper No Prepared By:

Former Guterl Specialty Steel Site

APPENDIX Q BLASTING IMPACT ASSESSMENT REPORT

Sensitivity of AERSURFACE Results to Study Area and Location. Paper 2009-A-127-AWMA

EXPLORATION NEWS RELEASE MAGISTRAL DISTRICT: MORE GROWTH, MORE GOLD, MORE SILVER

Speedtech Mariner s EDGE

Implementation of the Alquist-Priolo Earthquake Fault Zoning Act in Los Angeles County

Position-versus-Time Graphs

4B.4 STATISTICAL SHORT-RANGE GUIDANCE FOR PEAK WIND SPEEDS AT EDWARDS AIR FORCE BASE, CA

Windcube TM Pulsed lidar wind profiler Overview of more than 2 years of field experience J.P.Cariou, R. Parmentier, M. Boquet, L.

Final WIND DATA REPORT. Narragansett School District Templeton, Massachusetts

Guidelines. H.1 Introduction

Interview with Dr. Jaya Singh. 1. How critical is weather monitoring in a solar power plant and what are all the parameters to be monitored?

Superstorm Sandy Willis Re s post-event field damage survey preliminary report

GROUND WATER/SURFACE WATER INTERACTIONS 1-3 AWRA SUMMER SPECIALTP CONFERENCE USING GIs TO MAP THE DEPTH TO SEDIMENT IN A POND

CASE STUDY OF THE NOVEMBER WINDSTORM IN SOUTH CENTRAL COLORADO

CW3E Atmospheric River Post Event Summary

Sensitivity of FIA Volume Estimates to Changes in Stratum Weights and Number of Strata. Data. Methods. James A. Westfall and Michael Hoppus 1

Working with Digital Elevation Models in ArcGIS 8.3

Using PRISM Climate Grids and GIS for Extreme Precipitation Mapping

Kimberly J. Mueller Risk Management Solutions, Newark, CA. Dr. Auguste Boissonade Risk Management Solutions, Newark, CA

Transcription:

Correlation of SODAR and Meteorological Tower Measurements Prepared for: West Virginia Division of Energy 4/18/2011

CORRELATION OF SODAR AND MET TOWER MEASUREMENTS Authors: Principal Investigator: Christine Risch Researcher: Elizabeth Eastham Center for Business and Economic Research Marshall University One John Marshall Drive Huntington, WV 25755 Phone: (304) 696-2313 Fax: (304) 696-6088 Acknowledgements: This report was assembled with the assistance and review by George Carico and Jamie Wolfe of the Center for Environmental, Geotechnical and Applied Sciences at Marshall University. The project is supported by the West Virginia Division of Energy. Disclaimer: The contents of this report reflect the views of the authors who are responsible for the accuracy of the data presented herein. The views expressed in this report are those of the authors and do not reflect the official policy or position of Marshall University or its governing bodies. The use of trade names, if applicable, does not signify endorsement by the authors.

Table of Contents Introduction... 1 Time Zone and Time Lag Configuration... 1 Met Tower Configuration... 2 Site Layout and Typical Conditions... 3 Data Filtering... 3 Filtering Wind Speed Data... 3 Filtering Wind Direction Data... 3 Overall SODAR Performance... 4 Correlation Results... 5 Wind Speed Correlation Results... 5 Wind Direction... 7 Wind Distribution... 8 Average Wind Speed Comparison... 9 Conclusions... 10 References... 11 i

Table of Figures Figure 1 SODAR v. Met Tower 1111 Wind Speed at 40m... 5 Figure 2 SODAR v. Met Tower 1111 Wind Speed at 50m... 6 Figure 3 SODAR v. Met Tower 1111 Wind Speed at 60m... 6 Figure 4 SODAR v. Met Tower 1111 Wind Direction at 50m... 7 Figure 5 SODAR v. Met Tower 1111 Wind Direction at 60m... 8 Figure 6 Distribution of Wind Direction at 50m... 8 Figure 7 Distribution of Wind Direction at 60m... 9 Figure 8 Average Wind Speeds for SODAR and Met Tower 1111 Readings... 10 Table of Tables Table 1 Measurement Heights... 1 Table 2 Anemometer Calibration Values... 2 Table 3 Percentage of Valid Data versus Height, at 90% Confidence... 4 Table 4 SODAR v. Met Tower Wind Speed Correlation Results... 5 Table 5 SODAR v. Met Tower Wind Direction Correlation Results... 7 Table 6 Average Wind Speeds... 9 Table of Equations Equation 1 Met Tower Calibration Calculation... 2 Equation 2 Determining 45 Difference... 4 ii

CORRELATION OF SODAR AND MET TOWER MEASUREMENTS Introduction This data correlation project was undertaken as part of a larger assessment project that aims to further development of wind energy on former surface-mined land in West Virginia. The study area is located in the vicinity of historical surface mine operations in northeastern West Virginia. The project utilized a Second Wind Triton Sonic Detection And Ranging (SODAR) unit to compare measured wind speed and direction data with the same data collected by a nearby meteorological (met) tower located in northeastern West Virginia. This report compares the correlation of wind speeds recorded by the SODAR unit and nearby met tower 1111 during a three week period from November 10, 2010 until December 1, 2010. For guidance in analyzing the data, two recent comparison reports were modeled (Scott, Elliott and Schwartz 2010, Walls 2010). Two main correlations will be calculated: Wind speed data Wind direction data. Both the met tower and the SODAR unit recorded wind speed measurements at varying heights during this three week time frame. Three reading heights, at 40, 50 and 60 meters, were logged by both measurement units, while the SODAR unit measured wind speeds at additional taller heights. However, due to the layout of the site, the SODAR unit had to be placed slightly downhill from the met tower and was therefore was positioned about 14 meters lower than the ground level of the met tower. The following measurement heights were paired to compensate for the 14 meter height difference and will be used for the correlations. Table 1 Measurement Heights SODAR Height Met Tower Height SODAR Difference 50m 40m -4m 60m 50m -4m 80m 60m +6m Met tower 1111 has both a Northwest and South anemometer reading at the 60 meter height. For the purpose of the correlation, the average of these two anemometers will be used after calibration, as described below. Time Zone and Time Lag Configuration Wind speed measurements documented by met tower 1111 were recorded in Eastern Standard Time (EST). In contrast, wind speed measurements documented by the SODAR unit were recorded in Universal Standard Time (UST). For this reason, the times provided in the original Page 1 of 11

data set for the SODAR unit prior to the end of Daylight Savings Time (DST) were decreased by four hours. As DST ended at 2:00 AM EST on November 7, 2010, the SODAR unit time records needed to be decreased by an additional hour. Therefore, times provided in the original data set for the SODAR unit during the specified time period have been decreased by a total of five hours to be consistent with EST recordings. Also, both the SODAR unit and the met tower record wind speed data at 10 minute intervals. However, a lag in time reporting exists. The timestamp for the SODAR unit records the time at the end of the 10 minute period while the met tower timestamp records the time at the beginning of the 10 minute period. Therefore an 11:00 AM EST reading for the SODAR corresponds to a 10:50 AM EST reading for the met tower. The SODAR unit was located near met tower 1111 from 2:20 PM EST on November 10, 2010 until December 1, 2010 at 12:40 PM EST. Due to the lag in time reporting, the correlation will follow this time period with the met tower reading beginning at 2:10 PM EST on November 10, 2010. Met Tower Configuration Calibration calculations for slope and offsets for the Northwest and South anemometers at the 60 meter height on the met tower were made. The calibration calculation is illustrated in Equation 1. Equation 1 Met Tower Calibration Calculation Where: represents the calibrated speed in MPH represents the recorded wind speed in MPH represents the slope calibration value represents the offset calibration value. The following table provides the slope and offset calibration values for each anemometer. Table 2 Anemometer Calibration Values Anemometer Slope Calibration Value Offset Calibration Value Northwest 0.758 0.39 South 0.76 0.37 Wind speeds recorded by the met tower, measured in miles per hour (MPH), also had to be adjusted and converted to match the SODAR s wind speed reading of meters per second (m/s). After the calibrations were made, a conversion factor of 0.44704 m/s was applied to the met tower s MPH readings for consistency. Page 2 of 11

Site Layout and Typical Conditions The SODAR was located 680 feet away from the met tower at an elevation 46 feet (14m) lower than the tower. The immediate site was an open field located within an immature wooded area. Scattered large and small trees surrounded the site. Several trees with heights of 60 to 65 feet were located between 57 and 92 feet away from the SODAR unit. Second Wind recommends siting a Triton no closer to trees than three times their height due to the potential for the trees to cause some wind speed averages to be echo-affected (Second Wind 2009). However, the density of the foliage in the area made tree removal impractical for this project. Data Filtering Filtering Wind Speed Data Before measurements from the met tower were correlated with the SODAR data readings at the three measurement heights, both sets of data were filtered. The SODAR unit data was sorted to remove any observation in which a wind speed measurement was not taken or was equal to zero. 1 Similarly, the met tower data was sorted to remove observations in which a wind speed measurement was not taken or was equal to zero, 2 and was subjected to an additional filter to remove any observations which read less than 0.5 m/s. Because the calibration offset on a typical anemometer is approximately 0.35 m/s, the purpose of this additional filter is to ensure that the documented reading is greater than the value of the offset (Scott, Elliott and Schwartz 2010). Filtering Wind Direction Data Additional correlations were conducted to compare wind direction (in degrees) for the SODAR unit and the met tower. For these correlations, wind direction values recorded by the met tower were only available at the 50 and 60 meter heights and are compared to the 60 and 80 meter SODAR readings, respectively. Similar to the wind speed correlations discussed in the previous section, the wind direction correlations follow the same time reporting period. The same low wind speed observations removed from the wind speed correlations were removed from this data set to maintain consistency. Any observation in which a wind direction was not recorded for either the met tower or the SODAR unit was omitted. Wind direction data was also adjusted to account for readings in the northern direction sector. A reading of 1 compared to a reading of 359 is, in actuality, only 2 different. However, comparing the base numbers of one and 359 will skew the reading in determining the correlation coefficient. Therefore, any observations limited to the northern direction sector where the difference between the SODAR and met tower readings is less than 45 were adjusted by 360. The following equation was used to determine the 45 difference: 1 In any instance where one observation for either the met tower or SODAR unit was removed, the entire observation for that 10 minute interval was removed to maintain a consistent number of observations for each height and wind speed measurement. 2 As a result of the calibration of the Northwest and South anemometers on the met tower, some values which were originally recorded as 0 MPH were converted to 0.3 m/s. These observations were also removed from the correlations. Page 3 of 11

Equation 2 Determining 45 Difference Where: represents SODAR direction reading A represents met tower direction reading A. This equation calculates the difference between a large SODAR unit observation and a small met tower observation. The same equation was used by replacing the and variables to calculate the difference between a large met tower observation and a small SODAR unit observation. The following example illustrates this adjustment in detail. Assume that for Observation A the met tower direction was 13 and the SODAR unit direction was 340. Inserting these values into the difference equation: Because the difference is less than 45, 360 will be added to the met tower direction reading so that the new observation value is 373. The same method is also used to adjust small SODAR unit readings compared to large met tower readings. Overall SODAR Performance The operational uptime of the SODAR unit was 99.97 percent. This resulted in gross data recovery of 3,014 observations out of a possible 3,015 observations over the three week time period. The met tower did not record wind speeds for one continuous period of 6 hours and 20 minutes during the three weeks. The percentage of valid data versus height available for correlation at the three heights of comparison is shown below, before and after filtering. The 90 percent quality level is shown, as that is the level chosen for this correlation. Table 3 Percentage of Valid Data versus Height, at 90% Quality Height Data Count Unfiltered Data Count Filtered # Obs % # Obs % 40 m 2,941 98 2,894 96 50 m 2,975 99 2,931 97 60 m 2,972 99 2,930 97 Page 4 of 11

Correlation Results The following subsections illustrate the relationship between the SODAR unit and met tower measurements on the basis of wind speed and wind direction. Wind Speed Correlation Results After configuring and filtering the wind speed data, the correlation coefficients and number of observations were calculated for each measurement height. The results of these calculations are provided in the following table. Table 4 SODAR v. Met Tower Wind Speed Correlation Results Height Coefficient Data Count 40m 0.9604 2928 50m 0.9632 2930 60m 0.9673 2861 The correlation coefficients calculated for all three measurement heights demonstrate that the SODAR unit and met tower wind speed readings are highly correlated. Figures 1 through 3 illustrate a graphical representation of the data used for each correlation. Figure 1 SODAR v. Met Tower 1111 Wind Speed at 40m 18.00 16.00 14.00 SODAR (m/s) 12.00 10.00 8.00 6.00 4.00 y = 0.9477x + 0.269 R² = 0.9223 2.00 0.00 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 Met Tower 1111 (m/s) Page 5 of 11

Figure 2 SODAR v. Met Tower 1111 Wind Speed at 50m SODAR (m/s) 20.00 18.00 16.00 14.00 12.00 10.00 8.00 6.00 4.00 2.00 y = 0.9466x + 0.2149 R² = 0.9277 0.00 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 Met Tower 1111 (m/s) Figure 3 SODAR v. Met Tower 1111 Wind Speed at 60m SODAR (m/s) 22 20 18 16 14 12 10 8 6 4 2 y = 1.0982x - 0.1978 R² = 0.9356 0 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 Met Tower 1111 (m/s) Page 6 of 11

Wind Direction After configuring and filtering the wind direction data, the correlation coefficients and number of observations were then calculated for each measurement height. The results of these calculations are provided in the following table. Table 5 SODAR v. Met Tower Wind Direction Correlation Results Height Coefficient Data Count 50 m 0.9719 2930 60 m 0.9519 2861 Both correlation coefficients at the 50 and 60 meter heights demonstrate that the SODAR unit and met tower wind direction readings are highly correlated. Wind direction data was not available from the met tower at 40 meters. Figures 4 and 5 provide a graphical representation of the data used for each correlation. Figure 4 SODAR v. Met Tower 1111 Wind Direction at 50m 450 400 350 SODAR (m/s) 300 250 200 150 100 y = 0.9869x - 3.4308 R² = 0.9446 50 0 0 50 100 150 200 250 300 350 400 450 Met Tower 1111 (m/s) Page 7 of 11

Figure 5 SODAR v. Met Tower 1111 Wind Direction at 60m 450 400 350 SODAR (m/s) 300 250 200 150 100 y = 0.9922x - 4.4605 R² = 0.9061 50 0 0 50 100 150 200 250 300 350 400 450 Met Tower 1111 (m/s) Wind Distribution Wind rose charts were also created to illustrate wind direction distributions between the SODAR unit and met tower 1111. These distributions are provided in Figures 6 and 7. Figure 6 Distribution of Wind Direction at 50m Page 8 of 11

Figure 7 Distribution of Wind Direction at 60m Average Wind Speed Comparison Average wind speeds were calculated for the three measurement heights to further examine the SODAR unit and met tower wind speed readings. The same time period and data set used for the correlation were studied. The following table provides the average wind speeds and differences by measurement height. Table 6 Average Wind Speeds Height Met Tower SODAR Difference 40m 6.47 6.40 0.07 50m 7.02 6.86 0.16 60m 7.14 7.64-0.50 Consistent with the wind speed correlations, the average wind speeds of the met tower and SODAR unit at each measurement height were very similar. The largest difference occurred with the 60 and 80 meter correlation where the SODAR unit recorded an average wind speed that was 0.5 m/s faster than the met tower. This difference could be explained by the larger height difference of 6 meters after taking into account the 14 meter base height difference. This data is also illustrated in Figure 8. Page 9 of 11

Figure 8 Average Wind Speeds for SODAR and Met Tower 1111 Readings 70 60 50 40 30 Met Tower 1111 SODAR 20 10 0 0.00 2.00 4.00 6.00 8.00 10.00 Conclusions The results of the correlations demonstrate that the SODAR unit and met tower are highly correlated with respect to wind speed and direction measurements. Further illustration of the relationship between the SODAR unit and met tower wind direction distributions using wind roses also shows very consistent measurement readings. Page 10 of 11

References Scott, G., D. Elliott, and M. Schwartz. Comparison of Second Wind Triton Data with Meterological Tower Measurements. Technical Report, Golden: National Renewable Energy Laboratory, 2010. Second Wind. "Guidelines for Siting a Triton by Met Towers, Trees and in Complex Terrain." User Manual, 2009. Walls, Liz. Guidelines for Triton Data Analysis and Comparison to Nearby Met Tower Measurements, rev. 3.1. Secondwind, 2010. Page 11 of 11