Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Similar documents
Thermo Scientific. Anion-Exchange Column

Dionex IonPac AS28-Fast-4µm column

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

columns IonPac AS17-C Anion Exchange Column

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

columns IonPac AS18 Anion-Exchange Columns

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

columns IonPac AS22 Anion-Exchange Column

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

anion-exchange column

Utility of the Charge Detector in Ion Chromatography Applications

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Determination of Organic Acids in Beer Samples Using a High-Pressure Ion Chromatography System

for IonPac AG11-HC IonPac AS11-HC

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Determination of trace anions in concentrated hydrofluoric acid

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

columns IonPac SCS 1 Silica Cation Separator

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

suppressors SRS -ULTRA Self-Regenerating Suppressor

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Thermo Scientific Dionex eluent suppressors for ion chromatography

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

Inline sample preparation for the determination of anions in sodium hydroxide

Determinations of Heat Stable Amine Salts and Amines in Amine Scrubbing Solutions Using Suppressed Conductivity and Charge Detection

Expanded capabilities in ammonium and amine detection

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Overcoming Challenging Matrices in Ion Chromatography

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

suppressors Eluent Suppressors for Ion Chromatography

High-Performance Chromatography Superior isocratic separation of

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

PRODUCT MANUAL. OMNIPAC PAX-100 GUARD COLUMN (4 x 50 mm, P/N ) OMNIPAC PAX-500 GUARD COLUMN (4 x 50 mm, P/N )

Determination of Trace Anions in Organic Solvents

IonPac Trace Cation Concentrator

The determination of trace anions in concentrated phosphoric acid

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Determination of trace anions in high-nitrate matrices by ion chromatography

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Determination of Inorganic Anions in Wastewater by Ion Chromatography

The Determination of Trace Anions in Concentrated Phosphoric Acid

Determination of Adsorbable Organic Halogen in Wastewater

Determination of urea in ultrapure water by IC-MS/MS

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

A Platform Method for Pharmaceutical Counterion Analysis by HPLC

Determination of Monochloroacetic Acid in Carbocisteine

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

groups I and II cations, amines, divalent transition metals

Determination of trace anions in organic solvents using matrix elimination and preconcentration

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath

Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column

Determination of Methylamine in Drug Products

ProPac WCX-10 Columns

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

The power to increase productivity. Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Cation Exchange HPLC Columns

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography

HILIC Method Development in a Few Simple Steps

Determination of trace anions in concentrated glycolic acid

Development of the Thermo Scientific Dionex IonPac AS26 Column for Haloacetic Acid Analysis

PRODUCT MANUAL. for the. IONPAC CG14 GUARD COLUMN (2 x 50 mm, P/N ) (4 x 50 mm, P/N )

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

IC5000 Ion Chromatography System

PRODUCT MANUAL OMNIPAC PCX-500 GUARD COLUMN (PCX-500 GUARD, P/N ) OMNIPAC PCX-500 ANALYTICAL COLUMN (PCX-500 ANALYTICAL, P/N )

[ Care and Use Manual ]

Determination of Perchlorate in High Ionic Strength Fertilizer Extracts by Ion Chromatography

Monitoring Protein PEGylation with Ion Exchange Chromatography

IC Columns Introduction

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

IonPac SCS 1 IonPac SCG 1

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Transcription:

Chromatography Thermo Scientific Anion-Exchange Column Product Specifications Attain the optimal resolution of organic acids and inorganic anions using the new Thermo Scientific Dionex IonPac AS11-HC-4µm anion-exchange column. is a high-capacity, high-efficiency anion-exchange column that provides excellent resolution of organic acids and inorganic acids in complex matrices using potassium hydroxide gradient elution. Compared to the previous Dionex IonPac AS11-HC column, the new ion-exchange column uses smaller resin particles for more efficient separations resulting in more accurate peak integration and more reliable results. Column: (4 mm) Eluent Source: Thermo Scientific Dionex EGC 5 KOH Cartridge Eluent: 1 mm KOH from min; Peaks: 1. Quinate 5. mg/l 1 mm KOH from to 16 min;. Fluoride 1.5 to 3 mm KOH from 16 to min; 3. Lactate 5. 3 to 6 mm KOH from to 33 min 4. Acetate 5. Flow Rate: 1.5 ml/min 5. Propionate 5. Inj. Volume: µl 6. Formate 5.. Butyrate 5. Detection: Suppressed conductivity, Thermo Scientific. Methylsulfonate 5. Dionex ASRS 3 Anion Self-Regenerating 9. Pyruvate 5. Suppressor 4 mm, AutoSuppression, recycle mode. Valerate 5. 11. Monochloroacetate 5. 1. Bromate 5.. Chloride.5 14. Nitrite 5.. Triflouroacetate 5. 16. Bromide 5. 1. Nitrate 5. 1. Carbonate 6 19. Malonate.5 16 1 6. Maleate.5. Sulfate.5 9 11 1 14 19 3 9. Oxalate.5 3 4 5 3. Tungstate. 1 1. Phosphate.. Phthalate. 6. Citrate.. Chromate. 3 4. cis-aconitate 9. trans-aconitate. is a high-capacity, anion-exchange column with similar selectivity and increased peak efficiencies compared to the Dionex IonPac AS11-HC column. This high-capacity column is designed to resolve a large number of organic acids and inorganic anions in complex matrices, using potassium hydroxide gradient elution. The column is ideal for the determination of organic acids in uncharacterized samples. Applications using the Dionex IonPac AS11-HC column can be easily transferred to the column with the benefit is increased peak resolution, which provides more reliable results. The column is available in 4 mm, mm, and.4 mm i.d. formats. Highlights High-resolution separation of a wide variety of organic acids and inorganic anions in complex matrices Superior peak efficiency provides easier integration and more accurate results High-capacity allows injection of more concentrated samples without overloading and peak broadening

Column Features uses smaller particles than previous anionexchange columns resulting in excellent peak efficiencies and higher resolution separations. Improved resolution makes peak integration easier and more reliable leading to more accurate results. The high-capacity Dionex IonPac AS11-HC-4µm column allows the injection of more concentrated samples without overloading and peak broadening. A wide range of organic acids and inorganic anions can be separated in approximately 4 min using a sodium hydroxide gradient at a controlled temperature of 3 C, as illustrated in Figure 1. Highlights is solvent-compatible, which allows for anion-exchange selectivity control and easy column cleanup after the analysis of complex matrices. Typical applications include the determination of organic acids and inorganic anions in diverse sample matrices including: Fruit juices and wines Foods and beverages Fermentation and process solutions Chemical additives Chemical process solutions Wastewater Brines Power plant waters Economical Capillary Operation is also available in the.4 mm i.d. format for capillary operation offering the advantage of reduced operating costs. Ideal for limited sample volumes due to higher mass sensitivity. One hundred fold reduction in eluent consumption and waste disposal. 4 mm applications can be directly transferred to the.4 mm format by reducing flow rate by one hundred fold. Figure shows the high-resolution separation of inorganic anions and organic acids using the Capillary column. Column: Dionex IonPac AG11-HC-4µm/AS11-HC-4µm Peaks: 1. Quinate 5. mg/l (.4 mm). Fluoride 1.5 Eluent: 1 mm KOH for.1 min; 3. Lactate 5. 1 5 mm KOH from.1 to min; 4. Acetate 5. 5 to 55 mm KOH from to min 5. -Hydroxybutyrate 5. Eluent Source: Dionex EGC KOH cartridge 6. Propionate 5. Flow Rate: µl/min. Formate 5. Inj. Volume:.4 µl. Butyrate 5. 9. Methylsulfonate 5. Detection: Suppressed conductivity, Dionex ACES 3 Suppressor,. Pyruvate 5. AutoSuppression, recycle mode 11. Isovalerate 5. 1. Valerate 5.. Monochloroacetate 5. 14. Bromate 5.. Chloride.5 16. -Oxovalerate 5. 3 1. Nitrite 19. Trifluoroacetate 5. 5. 1. Ethylphosphate. Bromide 5. 5.. Nitrate 5.. Citramalate.5 3. Malate.5 31. Carbonate.5. Malonate.5 6. Citraconitate.5 33. Maleate.5 19 3 6 35. Sulfate.5 9. alpha-ketoglutarate.5 9 3 36 3. Oxalate.5 9 34 33 4 31. Fumarate.5 3 4 3. Tungstate. 5 6 14 1 33. Phosphate. 1 11 1 16 1 39 34. Phthalate. 35. Arsenate. 36. Citrate. 3. Chromate. - 3. Isocitrate. 3 4 39. cis-aconitate 4. trans-aconitate. Figure 1. provides a high-resolution separation of a wide range of organic acids and inorganic acids using sodium hydroxide gradient elution. The excellent peak efficiency allows for the separation more peaks in a single run. Column: Dionex IonPac AG11-HC/AS11-HC Peaks: 1. Quinate 5. mg/l (.4 mm). Fluoride 1.5 Eluent Source: Dionex EGC-KOH (Capillary) Cartridge 3. Lactate 5. Eluent: Potassium hydroxide 4. Acetate 5. 1 mm from to 5 min, 5. Propionate 5. 1 mm to mm from 5 to 14 min, 6. Formate 5. mm to 3 mm from 14 to 3 min,. Butyrate 5. 3 mm to 6 mm from 3 to 31 min. Methylsulfonate 5. Flow Rate: µl/min 9. Pyruvate 5. Inj. Volume:.4 µl. Valerate 5. 11. Monochloroacetate 5. Detection: Suppressed conductivity, Dionex ACES 3 Suppressor, 1. Bromate 5. AutoSuppression, recycle mode. Chloride.5 14. Nitrite 5.. Triflouroacetate 5. 16. Bromide 5. 1. Nitrate 5. 1. Carbonate 19. Malonate.5. Maleate.5 6. Sulfate.5 16 1 6. Oxalate.5 3. Tungstate. 9 11 1 14 19 3 9. Phosphate.. Pthalate. 3 4 5 1 1 6. Citrate.. Chromate.. cis-aconitate 9. trans-aconitate. 3 4 Figure. Gradient separation of inorganic anions and organic acids using the Dionex IonPac AS11-HC Capillary column.

High-Efficiency Particle Structure packing has unique structures composed of a highly crosslinked core and a Thermo Scientific Dionex MicroBead anionexchange layer attached to the surface, as shown in Figure 3. The Dionex IonPac AS11-HC-4µm column uses a 4 µm diameter super macroporous resin bead composed of ethylvinylbenzene crosslinked with 55% divinylbenzene. The anion-exchange layer is functionalized with quaternary ammonium groups. This anion-exchange layer has a controlled thickness, which results in excellent mass transfer characteristics and, consequently, very high-efficiency peaks. The combination of this controlled latex layer on the smaller particle size produces even higher efficiency peaks and better resolution. Solvent-Compatible Packing is % HPLC solvent compatible, therefore organic solvents can be used for efficient column cleanup or to enhance sample solubility. Time and expense can be saved through the elimination of time-consuming sample preparation steps. This feature allows complex matrices to be analyzed with minimal sample preparation and extends the utility of the column to new applications requiring solvents. Adding organic solvents to the eluent modifies column selectivity and enables the elution of nonpolar analytes or contaminants from the column. Determination of Short-Chain Organic Acids Weakly retained organic acids and inorganic anions commonly encountered in the food, beverage, biopharmaceutical, chemical, and power industries can be determined in a single run using the Dionex IonPac AS11-HC-4µm column. Resolution of monovalent organic acids and improved peak shape are two benefits of the high-resolution of the column. Increased Flexibility for Methods Development The solvent compatibility of the Dionex IonPac AS11-HC-4µm column permits the use of HPLC organic solvents in the eluent to modify ion-exchange selectivity. Both hydroxide concentration gradients and organic solvent gradients combined with elevated temperature can be used to achieve optimum resolution of closely eluting analyte pairs. The retention of the more hydrophobic member of the unresolved pair is decreased Figure 3. Structure of the column packing particle. Columns: Dionex IonPac AG11-HC-4µm/AS11-HC-4µm (4 mm) Aqueous Eluent: 1 mm KOH from to. min; 1 mm from. to min; 3 mm from to 3.3 min; 3 6 mm from 3.3 to 5.6 min + Methanol: Same KOH gradient % Methanol from to. min; % % Methanol from. to min; % Methanol from to 3.3 min; % Methanol from 3.3 to 5.6 min Eluent Source: Dionex EGC 5 KOH Cartridge Flow Rate: 1. ml/min Inj. Volume: µl Detection: Suppressed conductivity, Dionex ASRS 3 Suppressor 4 mm, external water mode -1 Eluent with Methanol 9 1 3 45 6 111 14 16 1 1 19 Figure 4. Effect of solvent on column selectivity and response. more by the addition of solvent, which improves resolution. Note that the solvent can also reduce the response of some anions so it should only be used as needed for improved separations. Figure 4 illustrates the effect of solvent on selectivity and response of monovalent and divalent organic 3 9 3 3435 36 3 3 6 31 33,,3 9 Aqueous Eluent,6 3 16 3 3 9 4,5 14 19 3536 31 3334 6 1 3 1 3 1 11 1-1 3 4 5 6 Highly Crosslinked Ethylvinylbenzene-Divinylbenzene Core -nm Diameter MicroBead Anion-Exchange Latex Coating 3 4 µm SEM Image of 4 µm Supermacroporous Bead Peaks: 1. Quinate mg/l. Fluoride 3 3. Lactate 4. Acetate 5. Glycolate 6. Propionate. Formate. Butyrate 9. Methylsulfonate. Pyruvate 11. Valerate 1. Galacturonate. Monochloroacetate 14. Bromate. Chloride 5 16. Nitrite 1. Trifluoroacetate 1. Sorbate 19. Bromide. Nitrate. Glutarate. Succinate 3. Malate. Carbonate. Malonate 6. Tartrate. Maleate. Sulfate 9. Oxalate 3. Fumarate 31. Tungstate 3. Phosphate 33. Phthalate 34. Citrate 35. Chromate 36. Isocitrate 3. cis-aconitate 3. trans-aconitate acids on the column. The column can be operated at ambient or elevated temperatures. The use of a controlled column temperature ensures reproducible results. 3

4 Column for Monovalent and Divalent Organic Anions The column provides improved separation of monovalent and divalent organic acids and inorganic anions using a sodium or potassium hydroxide gradient at a controlled temperature of 3 C. Because higher eluent concentrations can be used to separate monovalent anions, the higher capacity allows injection of more concentrated samples without overloading and provides improved peak shapes for monovalent organic acids in complex matrices, as illustrated in Figure 1. Determination of Carboxylic Acids in Complex Matrices can be used to monitor the organic acid and inorganic anion content in the quality control of foods, wines, and beverages. The high-capacity of the column makes it ideal for the analysis of organic acids and inorganic anions in complex matrices. Samples high in ionic-strength can be injected directly onto the column and do not cause overloading problems or poor peak shapes for monovalent organic acids (e.g., lactate, acetate, propionate, formate, and butyrate). Figure 5 shows the analysis of beer using the column. Butyrate is an important indicator of deterioration of foods and beverages and can be easily baseline resolved from formate on the column with a sodium hydroxide gradient/methanol gradient step change. Column: Dionex IonPac AG11-HC-4µm/AS11-HC-4µm ( mm) Eluent with Methanol: 1 mm KOH from to min with % Methanol, % to % Methanol at.1 min 1 mm KOH from.1 to1 min +% Methanol; to 3 mm KOH from 1 to min +% Methanol; 3 to 6 mm KOH from to 3 min +% Methanol Eluent Source: Dionex EGC III KOH Cartridge Flow Rate:.3 ml/min Inj. Volume:.5 µl Detection: Suppressed conductivity, Dionex ASRS 3 Suppressor mm, AutoSuppression, external water mode Sample: Beer sample with 1:5 dilution Peaks: 1. Quinate 5 mg/l. Fluoride 3 3. Lactate 5 4. Acetate 5 5. Propionate 5 1 6. Formate 5 Standard 9. Butyrate 5 11. Pyruvate 9. Chloride 5 1 3 4 6 5 16 1 19 14 1. Bromide 5 11. Nitrate 5 Beer Sample + ppm Butyrate 1. Succinate. Malate 14. Tartrate. Sulfate Beer Sample 16. Fumarate 1. Oxalate 1. Phosphate 19. Citrate. Isocitrate -. cis-aconitate 3 4 45. trans-aconitate Figure 5. Analysis of beer spiked with mg/l (ppm) butyrate using the column.

Figures 6 and illustrate the separation of organic acids and inorganic anions in blush and red wine and apple and cranberry juice using the column. This column provides improved resolution over the previous anion-exchange columns for components with widely varying concentration ratios. The Dionex IonPac AS11-HC-4µm column resolves succinate and malate, even at very different concentrations in the apple juice, as shown in Figure. Column: Dionex IonPac AG11-HC-4µm/AS11-HC-4µm ( mm) Gradient: 1 mm KOH from to min with % Methanol; to % Methanol at.1 min; 1 mm KOH from to 1 min +% Methanol; 3 mm KOH from 1 to min +% Methanol; 3 6 mm KOH from to 3 min + % Methanol Eluent Source: Dionex EGC 5 KOH Cartridge Flow Rate:.3 ml/min Inj. Volume:.5 µl Detection: Suppressed conductivity, Dionex ASRS 3 Suppressor mm, external water mode Sample Prep.: -fold dilution Peaks: 1. Quinate 5 mg/l. Fluoride 3 3. Lactate 5 4. Acetate 5 14 16 5. Propionate 5 1 6. Formate 5. Butyrate 5 Standard 11 1 1 19. Pyruvate 6 9. Galacturonate 1 3 4 5 3 9. Chloride 5 11. Bromide 5 Blush Wine 1. Nitrate 5. Succinate 14. Malate. Tartrate 16. Sulfate Red Wine 1. Fumarate 1. Oxalate 19. Phosphate. Citrate. Isocitrate -. cis-aconitate 3 4 45 3. trans-aconitate Figure 6. Analysis of blush and red wine using the column. 5 Column: Dionex IonPac AG11-HC-4µm/AS11-HC-4µm (.4 mm) Eluent + Methanol*: 1 mm KOH from to min; 1 mm KOH from to 1 min; to 3 mm KOH from 1 to min; 3 to 6 mm KOH from to 3 min Eluent Source: Dionex EGC KOH capillary cartridge Flow Rate: µl/min Inj. Volume:.4 µl Peaks: 1. Quinate 1 mg/l. Fluoride.6 Detection: Suppressed conductivity, Dionex ACES 3 Suppressor, 3. Lactate 1 AutoSuppression, external water mode 4. Acetate 1 Sample: Juice with 1:5 sample dilution 5. Propionate 1 6. Formate 1. Butyrate 1. Pyruvate 9. Galacturonate. Chloride 1 1 11. Bromide 1 1. Nitrate 1. Glutarate 14. Succinate 1. Malate 34 5 6, 9 11 1 16,119 3 Standard 14 16. Carbonate Cranberry Juice 1. Tartrate 1. Sulfate 19. Fumarate. Oxalate Apple Juice. Phosphate 3. Citrate 3 3. Isocitrate 3. cis-aconitate -. trans-aconitate 3 3 4 45 *% Methanol was added to DI water reservoir by volume Figure. Analysis of apple and cranberry juices using the column.

6 Table 1. Column selection guide. Analyte Fast profiling of mono-, di-, and trivalent organic acids and inorganic anions in well-characterized samples High-resolution of mono- and divalent organic acids Monovalent organic acids (lactate, acetate, propionate, formate, butyrate) Trace components in complex matrices using large-loop injection Organic acids and inorganic anions in high-ionic-strength matrices Organic acids in high-ionic-strength matrices (inorganic anions elute in void) Aromatic acids with conductivity detection Polarizable anions (iodide, thiocyanate, thiosulfate, perchlorate) Polyphosphates, polycarboxylates, and polysulfonates Preservatives (benzoate, citrate, sorbate) Recommended Column Dionex IonPac AS11 Dionex IonPac AS Dionex IonPac ICE-AS6 or Dionex IonPac ICE-AS1 Dionex IonPac AS11 Dionex IonPac AS16 Dionex IonPac AS16 Gradient Separations as Simple as Isocratic Runs with Eluent Generation The eluent generator (EG) produces high-purity potassium hydroxide eluent electrolytically, eliminating the need for eluent preparation. Only a source of deionized water is required. The potassium hydroxide eluent produced is free of carbonate contamination. The use of carbonate-free hydroxide eluents minimizes baseline shifts during hydroxide gradients, which provides greater retention time reproducibility, lower background conductivity, and lower detection limits for target analytes. Figure illustrates the gradient separation of heat-stable amine salts in water and up to 3% Methyldiethanolamine solution using the Dionex IonPac AS11-HC-4µm column with a potassium hydroxide gradient delivered by an EG. Monitoring of heat-stable salts is important to corrosion inhibition and waste discharge in the refinery industry. Column: Dionex IonPac AG11-HC-4µm/AS11-HC-4µm ( mm) Eluent Source: Dionex EGC 5 KOH Cartridge Gradient: Potassium hydroxide 1 mm from - to min; 1 3 mm from to min; 3 mm from to 3 min Flow Rate:.3 ml/min Inj. Volume: µl Column Temp.: 3 C Detection: Suppressed conductivity Dionex ASRS 3 Suppressor mm, recycle mode Samples: Heat stable salts in A: Water; B: % Methyldiethanolamine; C: 3% Methyldiethanolamine C B A 4 1 3 5 6 9 11 1 14 Peaks: 1. Fluoride mg/l. Acetate 3. Propionate 4. Formate 5. Chloride 6. Nitrite. Bromide. Nitrate 9. Carbonate 5. Sulfite 11. Sulfate 1. Oxalate. Phosphate 14. Thiosulfate - 3 Figure. Analysis of heat-stable amine salts using a column using a potassium hydroxide gradient delivered by an EG. 3

SPECIFICATIONS Dimensions: Analytical Column: mm and 4 mm Guard Column: 5 mm and 4 5 mm Capillary Column:.4 mm Capillary Guard Column:.4 5 mm Maximum Operating Pressure: 34.5 MPa (5 psi) Mobile Phase Compatibility: ph 14; % HPLC solvents Substrate Characteristics: Particle Diameter: 4 µm Pore Size: Å Crosslinking (%DVB): 55% Latex Characteristics: Functional Group: Alkanol quaternary ammonium ion Latex Crosslinking: 6% Latex Diameter: nm Hydrophobicity: Medium Low Capacity: 9 µeq (4 mm Analytical Column) µeq (4 5 mm Guard Column).5 µeq ( mm Analytical Column) 1.5 µeq ( 5 mm Guard Column).9 µeq (.4 mm Capillary Column). µeq (.4 5 mm Capillary Guard Column) Column Construction: PEEK with 3 threaded ferrule-style end fittings. All components are nonmetallic. System Requirements The Capillary column is recommended for use with the Thermo Scientific Dionex ICS-5 + Reagent Free HPIC or Thermo Scientific Dionex ICS-4 Capillary HPIC system. The Dionex IonPac AS11-HC-4µm Analytical column is recommended for use with the Dionex ICS-5 + HPIC system capable of operating up to 5 psi. The smaller particles used in the Dionex IonPac AS11-HC-4µm column generate higher backpressure under standard operating conditions and therefore cannot can be used with older Thermo Scientific Dionex IC systems. Suppressor Recommendations For optimum ease-of-use and performance, the column should be used with the Thermo Scientific Dionex AERS 5 Anion Electrolytically Regenerated Suppressor or the Thermo Scientific Dionex ACES 3 Anion Capillary Electrolytic Suppressor. Anion Trap Columns When using the EG for eluent delivery, a Thermo Scientific Dionex CR-ATC Continuously Regenerated Anion Trap Column should be installed between the eluent generator cartridge (EGC) and the degas module. As an alternative for 4 mm and mm systems, a Dionex IonPac ATC-HC column can be installed between the pump outlet and the EGC inlet. Alternatively, when using a manually prepared sodium hydroxide gradient with the column, the Dionex IonPac ATC-3 Anion Trap Column should be installed between the gradient pump and the injection valve to remove anionic contaminants from the eluent. Concentrator Columns For concentrator work with a mm or 4 mm column, use the Guard column; Ultra Trace Anion Concentrator columns (Dionex IonPac UTAC-ULP1, UTAC-XLP1, UTAC-ULP, or UTAC-XLP columns) or Trace Anion Concentrator Column (Dionex IonPac TAC-ULP1) when a single piston pump such as the Thermo Scientific Dionex AXP Auxiliary Pump (pulse damper required) is used for sample delivery. In addition to the concentrator columns listed above, use the Dionex IonPac UTAC-LP1, UTAC-LP or TAC-LP1 columns when the sample is delivered using a syringe or a low-pressure autosampler (e.g., Thermo Scientific Dionex AS-DV Autosampler). For concentrator work with a.4 mm capillary column, use Dionex IonPac AS11-HC-4µm Capillary Guard column or the Thermo Scientific Dionex IonSwift MAC- Concentrator Column.

Ordering Information In the U.S., call () 346-639 or contact the Thermo Fisher Scientific Regional Office nearest you. Outside the U.S., order through your local Thermo Fisher Scientific office or distributor. Refer to the following part numbers. Analytical, Capillary and Guard Columns Part Number Analytical Column (4 mm) 3 Dionex IonPac AG11-HC-4µm Guard Column (4 5 mm) 34 Analytical Column ( mm) 35 Dionex IonPac AG11-HC-4µm Guard Column ( 5 mm) 36 Capillary Column (.4 mm) 31 Dionex IonPac AG11-HC-4µm Capillary Guard Column (.4 5 mm) 3 Anion Trap Columns Dionex CR-ATC Continuously Regenerated Anion Trap Column (for use with systems equipped with an Eluent Generator or Thermo Scientific Dionex RFC-3 Reagent-Free Controller) 64 Dionex CR-ATC Continuously Regenerated Anion Trap Column (for use with capillary anion columns) Dionex IonPac ATC-3 4 mm (9 mm) Anion Trap Column (for use with 4 mm columns) 5966 Dionex IonPac ATC-3 mm (4 35 mm) Anion Trap Column (for use with mm columns) 993 Dionex IonPac ATC-HC (9 5 mm) Anion Trap Column (for use with Thermo Scientific Dionex EG4 Eluent Generator) 5964 Trace Anion Concentrator Columns Part Number Dionex IonPac TAC- Trace Anion Concentrator (3 35 mm) 431 Dionex IonPac TAC-LP1 Trace Anion Concentrator (4 35 mm) 466 Dionex IonSwift MAC- Monolith Anion Concentrator (.5 mm) (for use with capillary IC) 4 Dionex IonPac TAC-LP1 Trace Anion Concentrator (4 35 mm) 466 Dionex IonPac TAC-ULP1 Trace Anion Concentrator (5 3 mm) 614 Dionex IonPac UTAC-LP1 Ultra Trace Anion Concentrator Low Pressure (4 35 mm) 639 Dionex IonPac UTAC-ULP1 Ultra Trace Anion Concentrator Ultra Low Pressure (5 3 mm) 6345 Dionex IonPac UTAC-XLP1 Ultra Trace Anion Concentrator Extremely Low Pressure (6 16 mm) 63459 Dionex IonPac UTAC-LP Ultra Trace Anion Concentrator Low Pressure (4 35 mm) 991 Dionex IonPac UTAC-ULP Ultra Trace Anion Concentrator Ultra Low Pressure (5 3 mm) 991 Dionex IonPac UTAC-XLP Ultra Trace Anion Concentrator Extremely Low Pressure (6 16 mm) Product Specification www.thermoscientific.com/dionex Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Fisher Scientific, Sunnyvale, CA USA is ISO 91: Certified. Australia +61 3 95 43 Austria +43 6 Belgium +3 53 3 4 41 Brazil +55 11 331 514 Canada +1 53 44 China 511 (free call domestic) 4 65 511 Denmark +45 3 6 6 Finland +35 9 391 France +33 1 6 9 4 Germany +49 63 4 14 India +91 64 9494 Italy +39 95 591 Japan +1 6 65 1 Korea + 34 6 Latin America +1 561 6 Netherlands +31 6 59 55 55 New Zealand +64 9 9 6 Norway +46 556 46 Singapore +65 69 119 Sweden +46 556 46 Switzerland +41 61 16 Taiwan +6 51 6655 UK/Ireland +44 144 33555 USA +1 53 45 PS_E /S