Cyanide and sulfide analysis using amperometric detection and Metrosep A Supp /4.0

Similar documents
Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Analysis of various clays with Metrohm Combustion IC

Sulfur speciation in mining leachates by ion exchange with direct UV detection, using a perchlorate mobile phase.

Determination of Chloride, Fluoride, Bromide, Nitrate, Sulphate and Phosphate in Water Sample...

Air Monitoring. Semi-continuous determination of ambient air quality

Ion chromatography. Ion chromatography

Suppression in anion chromatography. More sensitive analysis of anions and organic acids

Draft Method proposal: determination of glucoheptonic acid (HGA) in fertilizers.

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Ion Chromatography Validation for the Analysis of Anions in Gunshot Residue

Determination of urea in ultrapure water by IC-MS/MS

DETERMINATION OF TOTAL HALOGEN CONTENT IN HALOGEN-FREE FLUXES BY INDUCTIVELY COUPLED PLASMA AND SOME LIMITATIONS OF ION CHROMATOGRAPHY

Determination of trace anions in concentrated hydrofluoric acid

Data Pack. Ion Chromatography Methods. June 2009

Determination of Trace Cations in Power Plant Waters Containing Morpholine

CIPAC. CIPAC Free relevant impurities methods:

Burning Through the Confusion: See How Combustion IC Provides Superior Halide Analysis

Ion Analysis of Hydraulic Fluids in Fracking Process

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

883 Basic IC plus. The smallest Metrohm ion chromatograph

Determination of Zinc, Cadmium, Lead and Copper in Effluent Sample

Determination of silicate in high-purity water using ion chromatography and online sample preparation

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

HYDROGEN CYANIDE 6017

Quantitative determination of ethephon in soluble concentration (SL) by Ion chromatography

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF

Pelagia Research Library

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Method of determination of phtalates in spirituous beverages by gaschromatography/mass

ION CHROMATOGRAPHY SYSTEM S 150

Combustion Ion Chromatography. Fast and reliable determination of halogens and sulfur

British American Tobacco Group Research & Development. Method - Determination of ammonia in mainstream smoke

The determination of trace anions in concentrated phosphoric acid

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography

Inline sample preparation for the determination of anions in sodium hydroxide

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Determination of trace anions in concentrated glycolic acid

The Determination of Trace Anions in Concentrated Phosphoric Acid

Problems with the measurement of NH 4 with Ion Chromatography

Quality Assurance is what we do to get the right answer for our purpose FITNESS FOR PURPOSE

Determination of Trace Anions in Concentrated Glycolic Acid

861 Advanced Compact IC

High performance liquid chromatography

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

METHOD 7199 DETERMINATION OF HEXAVALENT CHROMIUM IN DRINKING WATER, GROUNDWATER AND INDUSTRIAL WASTEWATER EFFLUENTS BY ION CHROMATOGRAPHY

Determination of mercury in water with the sctrace Gold

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

IonPac Trace Cation Concentrator

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

Chem 155 Unit 1 Spring 2010 Page 1 of 5

Determination of Benzoic acid Residue from Fruit Juice by Gas chromatography with Mass spectrometry Detection Technique

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

QUANTITATIVE DETERMINATION OF TARTARIC ACID IN TOLTERODINE TARTRATE BY ION CHROMATOGRAPHY USING CONDUCTIVITY DETECTION

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Iodide in milk. Robust Applications, Fluidly Running. Introduction. Application Note Food & Beverage

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS

Determination of Trace Anions in Concentrated Hydrofluoric Acid

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))

Waters. Ion Chromatography

Technical Report. Determination of Nitrite and Nitrate in Smokeless Tobacco Products by Ion Chromatography and Continuous Flow Analysis

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

TP Analytical Chemistry II 7 th, December 2012

Anethole. Gas chromatograhpy determination of trans-anethole in Spirit srinks of viti-vinicultural origin

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Determination of Trace Anions in Organic Solvents

Dionex IonPac AS28-Fast-4µm column

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

Department of Civil and Environmental Engineering, Stanford University, 473 Via Ortega, Stanford, California 94305, United States

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Applications of Ion-Selective Electrodes

Determination of adsorbable organic halogen in wastewater using a combustion ion chromatography system

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Impact factor: 3.958/ICV: 4.10 ISSN:

Appendix II- Bioanalytical Method Development and Validation

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Titer determination in potentiometry

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

Sulfotepp impurities in Chlorpyrifos EC formulations

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

BRIEFING. (EXC: K. Moore.) RTS C Propylparaben C 10 H 12 O Benzoic acid, 4 hydroxy, propyl ester; Propyl p hydroxybenzoate [ ].

Overcoming Challenging Matrices in Ion Chromatography

Combustion Ion Chromatography. Fast and reliable determination of halogens and sulfur

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

The analysis of organic acid content of additives, premix, feed, and water.

Determination of N-Methylcarbamates by Reversed-Phase HPLC

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

2011_ST20_Taylor.pdf. SSPT Document not peer-reviewed by CORESTA

Automatic determination of the bromine number and the bromine index in petroleum products

BUTYL ALCOHOL in urine by GC-FID Code GC05510

Transcription:

Metrosep A Supp 10-100 /4.0 Branch Environment, Food, Beverages Keywords IC; 850; 858; Metrosep A Supp 10-100/4.0; Cyanide; Sulfide; 2.850.9110; DC Mode Summary The determination of sulfide and cyanide in standard solutions was investigated on the Metrosep A Supp 10-100/4.0 column using sodium hydroxide eluent. The influence of chloride in the sample matrix regarding the sulfide and cyanide determination was also tested. Samples Spiked Herisau tap water analyzed on Metrosep A Supp 10-100/ 4.0 column. Instruments 881 Compact IC pro Cation 2.881.0010 858 Professional Sample Processor 2.858.0020 IC Amperometric Detector 2.850.9110 Wall - Jet Cell 6.1257.010 Spacer 50 µm 6.1257.810 Ag Working Electrode 6.1257.240 Pd Reference Electrode 6.1257.740 Metrosep A Supp 10-100/4.0 6.1020.010 Metrosep A Supp 10 Guard/4.0 6.1020.500 Reagents Sulfide standard stock solution, 1 g/l. The 1000 ppm sulfide standard was prepared from sodium sulfide (Fluka 71975). The purity was 35%. 695 mg of Sodium sulfide was diluted in a 100 ml flask with 100 mmol/l sodium hydroxide (= 1000 ppm). The 1000 ppm cyanide standard was prepared from potassium cyanide (Fluka 60179). The diluted cyanide and sulfide standards were dissolved in 100 mmol/l sodium hydroxide. Sodium hydroxide solution 30% Suprapur (Merck 1.05589.0250) IDRANAL III standard solution 0.2 mol/l (Fluka 35102) Solutions Eluent 100 mmol/l sodium hydroxide + 0.01mmol/L EDTA in ultra pure water (resistivity >18 M ) Standard solutions Concentration of the cyanide and sulfide standards in the MagIC Net standard table in [µg/l] Standards Sulfide Cyanide Std. 1 0.025 0.025 Std. 2 0.5 0.5 Std. 3 1.0 1.0 Std. 4 2.0 2.0 Std. 5 4.0 4.0 Std. 6 6.0 6.0 Std. 7 8.0 8.0 Std. 8 10.0 10.0 Sample preparation No sample preparation was required. Page 1 of 7

Analysis The samples and standards were injected with the 858 Professional Sample Processor. Parameters Flow Mode Cell potential Range Damping Channel 1.0 ml/min DC 0.0 V Auto on current Column temperature 35 C Detector temperature 35 C Sample Loop 20 µl Calculation Automatic integration with MagIC Net 2.3 software using peak area. The calculation of the injection precision based on twelve injections of the 6 ppb standard. Area (na) x min Mean (5) % RSD % Recovery Cyanide 0.5 1.95 87 Sulfide 0.53 0.39 113.8 The recovery is calculated according to double injection of a standard with the same concentration as the spiked samples. Comments Before the first usage only, the column needs an pretreatment. Rinsing with 50 mmol/l EDTA solution with standard flow for 3 h, followed by conditioning with the eluent for 12 h. The EDTA concentration in the eluent depends on the column. The EDTA push the sulfide and cyanide peaks on the A Supp 10 to the front of the chromatogram, while the system peak doesn`t move. In this case the correct concentration of EDTA helps to separate the sulfide from the system peak. Conc. [µg/l] Mean (12) % RSD Cyanide 6.05 0.87 Sulfide 6.14 0.34 Results The recovery of sulfide and cyanide was tested with the Herisau tap water. The water was spiked with 10 ppb cyanide and sulfide. Additional sodium hydroxide up to 100 mmol/l was added. Conc. [µg/l] Mean (3) % RSD Cyanide 10.37 1.97 Sulfide 9.65 0.50 Date Thursday, December 1, 2011 Author Gabriele Zierfels Competence Center Ion Chromatography Metrohm International Headquarters Appendix Result chromatograms with peak table, calibration curves. The influence of chloride in the sample matrix was investigated. Therefore standard solutions with 15 ppb cyanide and 2.5 ppb sulfide together with different concentrations of chloride (0 3 g/l) were analyzed on an A Supp 10-250/4.0 column. The chromatograms displayed a chloride disturbance peak. The cyanide peak flattens with increasing chloride concentration. With a chloride concentration of 0.6 g/l in the sample and higher, the cyanide peak could not be calculated automatically. Page 2 of 7

Appendix Standard 2 (the peak at 3.2 min is the system peak) Standard 6 Page 3 of 7

Chromatograms of the spiked standards (15 ppb cyanide and 2.5 ppb sulfide) with 0.1 1.0 g/l chloride. Analysis on A Supp 10 250/4.0 1-1.0 g/l chloride 2-0.9 g/l chloride 3-0.8 g/l chloride 4-0.7 g/l chloride 5-0.6 g/l chloride 6-0.5 g/l chloride 7-0.4 g/l chloride 8-0.3 g/l chloride 9-0.2 g/l chloride 10-0.1 g/l chloride 11 - standard solution without chloride 1 2 3 4 5 6 7 8 9 10 11 Calibration curves: Page 4 of 7

Stability check To check stability of the measurement a 10 ppb standard solution of sulfide and cyanide was injected 69 times from different vials. Page 5 of 7

Stability check Cyanide Reproducibility check For this test another standard solution of 10 ppb cyanide and sulfide was prepared and analyzed 14 times according the same chromatographic conditions. Page 6 of 7