Short Bunch Length Measurements

Similar documents
Particle Beam Diagnostics

Short Pulse, Low charge Operation of the LCLS. Josef Frisch for the LCLS Commissioning Team

EO single-shot temporal measurements of electron bunches

Hiromitsu TOMIZAWA XFEL Division /SPring-8

Generation and characterization of ultra-short electron and x-ray x pulses

Free-electron laser SACLA and its basic. Yuji Otake, on behalf of the members of XFEL R&D division RIKEN SPring-8 Center

Linac Driven Free Electron Lasers (III)

SPPS: The SLAC Linac Bunch Compressor and Its Relevance to LCLS

H. Maesaka*, H. Ego, T. Hara, A. Higashiya, S. Inoue, S. Matsubara, T. Ohshima, K. Tamasaku, H. Tanaka, T. Tanikawa, T. Togashi, K. Togawa, H.

Experimental Optimization of Electron Beams for Generating THz CTR and CDR with PITZ

Jitter measurement by electro-optical sampling

LOLA: Past, present and future operation

FURTHER UNDERSTANDING THE LCLS INJECTOR EMITTANCE*

Opportunities and Challenges for X

Femto-second FEL Generation with Very Low Charge at LCLS

Time resolved transverse and longitudinal phase space measurements at the high brightness photo injector PITZ

Linac Based Photon Sources: XFELS. Coherence Properties. J. B. Hastings. Stanford Linear Accelerator Center

Electro-optic techniques for temporal profile characterisation of relativistic Coulomb fields and Coherent Synchrotron Radiation.

Diagnostic Systems for Characterizing Electron Sources at the Photo Injector Test Facility at DESY, Zeuthen site

Observation of Coherent Optical Transition Radiation in the LCLS Linac

INVESTIGATIONS OF THE DISTRIBUTION IN VERY SHORT ELECTRON BUNCHES LONGITUDINAL CHARGE

Investigations on the electron bunch distribution in the longitudinal phase space at a laser driven RF-electron source for the European X-FEL

Present Capabilities and Future Concepts for Intense THz from SLAC Accelerators

Femtosecond X-ray Pulse Temporal Characterization in Free-Electron Lasers Using a Transverse Deflector. Abstract

Diagnostic Systems for High Brightness Electron Injectors

SPARCLAB. Source For Plasma Accelerators and Radiation Compton with Laser And Beam

Flexible control of femtosecond pulse duration and separation using an emittance-spoiling foil in x-ray free-electron lasers

CONCEPTUAL STUDY OF A SELF-SEEDING SCHEME AT FLASH2

Low slice emittance preservation during bunch compression

Juliane Rönsch Hamburg University. Investigations of the longitudinal phase space at a photo injector for the X-FEL

Optimum beam creation in photoinjectors using spacecharge expansion II: experiment

Coherent Cherenkov radiation from ultra-short electron bunch passing through vacuum channel in conical target

Commissioning of the new Injector Laser System for the Short Pulse Project at FLASH

FLASH overview. Nikola Stojanovic. PIDID collaboration meeting, Hamburg,

X-band Experience at FEL

An Adventure in Marrying Laser Arts and Accelerator Technologies

LCLS Injector Prototyping at the GTF

STATUS OF E-157: METER-LONG PLASMA WAKEFIELD EXPERIMENT. Presented by Patrick Muggli for the E-157 SLAC/USC/LBNL/UCLA Collaboration

ASTRA simulations of the slice longitudinal momentum spread along the beamline for PITZ

Microbunching Workshop 2010 March 24, 2010, Frascati, Italy. Zhirong Huang

Overview on the longitudinal diagnostics for ERLs

BUNCH LENGTH MEASUREMENT AT THE FERMILAB A0 PHOTOINJECTOR USING A MARTIN-PUPLETT INTERFEROMETER *

RF-Gun Experience at PITZ - Longitudinal Phase Space

SRF GUN CHARACTERIZATION - PHASE SPACE AND DARK CURRENT MEASUREMENTS AT ELBE*

X-Band RF Harmonic Compensation for Linear Bunch Compression in the LCLS

SPARCLAB. Source For Plasma Accelerators and Radiation Compton. On behalf of SPARCLAB collaboration

Femto second X ray Pulse Generation by Electron Beam Slicing. F. Willeke, L.H. Yu, NSLSII, BNL, Upton, NY 11973, USA

Simulations of the IR/THz Options at PITZ (High-gain FEL and CTR)

X-ray Free-electron Lasers

VELA/CLARA as Advanced Accelerator Studies Test-bed at Daresbury Lab.

LCLS Accelerator Parameters and Tolerances for Low Charge Operations

Coherent THz Pulses: Source and Science at the NSLS

Electro optic sampling as a timing diagnostic at Pegasus lab

Femtosecond Width X-ray Generation with the SLAC Linac and the FFTB Beamline *

S2E (Start-to-End) Simulations for PAL-FEL. Eun-San Kim

II) Experimental Design

THz Electron Gun Development. Emilio Nanni 3/30/2016

PoS(EPS-HEP2017)533. First Physics Results of AWAKE, a Plasma Wakefield Acceleration Experiment at CERN. Patric Muggli, Allen Caldwell

X-band RF driven hard X-ray FELs. Yipeng Sun ICFA Workshop on Future Light Sources March 5-9, 2012

Beam compression experiments using the UCLA/ATF compressor

Longitudinal Measurements at the SLAC Gun Test Facility*

UCLA Neptune Ramped Bunch Experiment. R. Joel England UCLA Department of Physics and Astronomy Particle Beam Physics Laboratory May 19, 2004

Plasma-based Acceleration at SLAC

Excitements and Challenges for Future Light Sources Based on X-Ray FELs

Beam Echo Effect for Generation of Short Wavelength Radiation

FACET-II Design Update

Echo-Enabled Harmonic Generation

Dielectric Accelerators at CLARA. G. Burt, Lancaster University On behalf of ASTeC, Lancaster U., Liverpool U., U. Manchester, and Oxford U.

Fast Simulation of FEL Linacs with Collective Effects. M. Dohlus FLS 2018

ATTOSECOND X-RAY PULSES IN THE LCLS USING THE SLOTTED FOIL METHOD

Femtosecond and sub-femtosecond x-ray pulses from a SASE-based free-electron laser. Abstract

Parameter selection and longitudinal phase space simulation for a single stage X-band FEL driver at 250 MeV

Longitudinal phase space tomography and its. implementation in energy recovery linacs

Excitements and Challenges for Future Light Sources Based on X-Ray FELs

3. Synchrotrons. Synchrotron Basics

X-Ray Diagnostics Commissioning at the LCLS

Brightness and Coherence of Synchrotron Radiation and Free Electron Lasers. Zhirong Huang SLAC, Stanford University May 13, 2013

Measurement of wakefields in hollow plasma channels Carl A. Lindstrøm (University of Oslo)

Simulations of the IR/THz source at PITZ (SASE FEL and CTR)

1 Mathematical description of ultrashort laser pulses

What have we learned from the LCLS injector?*

PAL LINAC UPGRADE FOR A 1-3 Å XFEL

R&D experiments at BNL to address the associated issues in the Cascading HGHG scheme

Emittance and Quantum Efficiency Measurements from a 1.6 cell S- Band Photocathode RF Gun with Mg Cathode *

Supplementary Figure 1 Schematics of an optical pulse in a nonlinear medium. A Gaussian optical pulse propagates along z-axis in a nonlinear medium

Insertion Devices Lecture 2 Wigglers and Undulators. Jim Clarke ASTeC Daresbury Laboratory

SwissFEL INJECTOR DESIGN: AN AUTOMATIC PROCEDURE

Short Introduction to CLIC and CTF3, Technologies for Future Linear Colliders

High Brilliance Beam Diagnostic

FLASH/DESY, Hamburg. Jörg Rossbach University of Hamburg & DESY, Germany - For the FLASH Team -

Short Wavelength SASE FELs: Experiments vs. Theory. Jörg Rossbach University of Hamburg & DESY

Simulations of the Microbunching Instability in FEL Beam Delivery Systems

Measurements of Short Bunches at SPPS and E-164X

Low energy high brilliance beam characterization

O rion. The ORION Facility at SLAC. Bob Siemann AAC Workshop, June 15, 2000

Experimental Path to Echo-75 at NLCTA

Two-Stage Chirped-Beam SASE-FEL for High Power Femtosecond X-Ray Pulse Generation

Advanced laser technology for 3D-shaping ~ toward to the highest brightness of electron beam source ~

Tuning Techniques And Operator Diagnostics for FACET at SLAC National Accelerator Laboratory. Chris Melton SLAC Accelerator Operations

L. Bobb 1, 2, M. Billing 3, N. Chritin 2, P. Karataev 1, T. Lefevre 2

Transcription:

CAS T. Lefevre Short Bunch Length Measurements What is short? Why short Bunches? How do we produce them? How do we measure them?

What is short? When you are courting a nice girl an hour seems like a second. When you sit on a red-hot cinder a second seems like an hour. That's relativity. Albert Einstein

Why do we need short pulses? Develop machine with the aim to improve luminosity for a linear collider or brightness for a radiation source Short pulse to resolve fast phenomenon Femto Chemistry : Pump probe experiment diffraction dynamics Nanoscale Dynamics in Condensed matter : Coherent scattering at nanoscale Atomic Physics : ex: photo ionization Plasma and Warm dense Matter ; Astrophysical and weapons related studies Structure Studies on Single Particles and Biomolecules : Xray diffraction,

Fast Chemistry Pump-probe experiment

Nanoscale dynamics

Structure Analysis

What is short in accelerators? Acceleration @ 3GHz P in P out E(t) DE z t At 3GHz 1deg = 925fs

Short bunches by Magnetic Compression d DE/E z i chirp d d undercompression z z z z di V = V 0 sin(kz) Dz = R 56 d Accelerating Voltage Path-Length Energy- Dependent Beamline

Short bunches by Ballistic Compression Velocity Bunching By decelerating the bunch head and accelerating the bunch tail Accelerating Field E(t) Need one dedicated accelerating cavity No CSR effect and emittance dilution in the bends t Classical method with low energy thermoionic guns New concept with guns and emittance compensation

Short bunches around the world ILC 500fs CLIC 130fs XFEL 80fs LCLS 75fs

How do we measure short bunch length Define characteristics of beam instrumentation 1- Longitudinal Profile RMS or FWHM values More precise information on the beam characteristic 2- Single shot measurements 1 n! Sampling measurements Do not care about the beam reproducibility No additional problem due to timing jitter 3- Non interceptive Destructive Devices Can be used for beam study and beam control for on-line monitoring No risk of damage by the beam itself

How do we measure short bunches Level of Difficulty and Reliability Beam diagnostics should help you to understand how the beam behaves, it should not be the opposite A detector, what for? Online Beam stability Non-intercepting and reliable Only have access to a partial information (RMS values,..) Beam characterization and beam physics study Full information Complexity and time consuming

How do we measure short bunches Can we do non intercepting, single shot, beam profile measurement in an easy way? 1 + + = All in red perfect system

How do we measure short bunches Optical Method Bunch Frequency 1. Produce visible light 2. Analyse the light pulse using dedicated instruments The shorter the bunches, the broader the bunch frequency spectrum cavities manipulation Use cavities to convert time information into spatial information -based beam diagnostic Using short laser pulses and sampling techniques

Cherenkov radiation Equivalent to the supersonic boom but for photons Threshold process: Particles go faster than light b > 1/n n is the index of refraction b is the relative particle velocity g is the particle relativistic factor g c is the Cherenkov light emission angle cos 1 b c 1 1 bn l the length of the cherenkov radiator 2 N cherenkov 1 2 l a 1 b 1 b 1 2 n 2 The total number of photons proportional to the thickness of the Cherenkov radiator more

Optical Transition Radiation Light intensity (arb.unit.) A huge amount of development for the past 30 years TR is generated when a charged particle passes through the interface between two materials with different permittivity (screen in vacuum) 4x10 4 3x10 4 Polarization Parallel I (, ) Perpendicular I ( = 0, ) OTR Backward emission 2x10 4 1x10 4 ~2/g Specular reflection N OTR Radiation wavelength 0-0.10-0.05 0.00 0.05 0.10 2 ln ln2 1 b g 2 a Angle (rad) Number of OTR photons per charge particle ~ 5 10-3 in [400-600]nm Beam energy more Limitations : The thermal limit for best screens (C, Be, SiC) is ~ 1 10 6 nc/cm 2 DT 2 r de N tot 2 2 ( r) e 2 dx 2 cp

Optical Diffraction Radiation DR is generated when a charged particle passes through an aperture or near an edge of dielectric materials, if the distance to the target h (impact parameter) satisfies the condition : Beam energy h g 2 Radiation wavelength Slit h e - ODR Light A lot of activities on ODR, but only one measurement up to now : T. Muto et al, Physical Review Letters 90 (2003) 104801 Limitations : Not enough photons in the visible for low energy particles : E < 1 GeV for a decent impact parameter (100mm)

Optical method : Streak Camera 1 Streak cameras uses a time dependent deflecting electric field to convert time information in spatial information on a CCD Mitsuru Uesaka et al, NIMA 406 (1998) 371 200fs time resolution obtained using reflective optics and 12.5nm bandwidth optical filter (800nm) and the Hamamatsu FESCA 200 Limitations : Time resolution of the streak camera : (i) Initial velocity distribution of photoelectrons : narrow bandwidth optical filter (ii) Spatial spread of the slit image: small slit width (iii) Dispersion in the optics

Streak camera examples 666 ps Observation of bunch train Sweep speed of 250ps/mm Measure of bunch length = 4.5ps (1.4 mm) Sweep speed of 10ps/mm = 8.9ps (2.7 mm)

Exercise You have just been hired to work on a 5MeV electron gun 4ps bunch length. Your first job is dedicated to the design of a bunch length monitor using Cherenkov radiation and a streak camera. As a reminder, Cherenkov light is emitted when a charge particle travels inside a transparent medium with a velocity higher than the speed of light in this medium. The Cherenkov photons are emitted all along the material thickness Speed of light inside the material : b is the relative particle velocity g is the particle relativistic factor : d the thickness of the Cherenkov radiator v g c n with n is the index of refraction of the material 1 1 b 2 Questions: What is the minimum index of refraction of the given material so that Cherenkov effect occurs? The condition to produce Cherenkov is that b is higher than 1/n. In our case for 5MeV electron, g 1 and corresponds to a b =0.995. n should be then higher than 1.005 Assuming that you will use fused silica as a Cherenkov radiator (index of refraction is 1.46), How thick must be the crystal to keep the time resolution below 1ps? Since the photons travel at a speed lower than the electrons, and the time resolution will correspond to the time difference between photons and electrons in order to traverse the radiator. d In the present case in order to keep the time resolution better than 1ps, it corresponds to 660mm Dt n c 1 bc

Exercise You have been promoted and are now in charge of the bunch length measurement at the end of the Linac for electrons energy of 50GeV (4ps bunch length). Your boss specifically asks for a non destructive method and you are considering Optical Diffraction Radiation. ODR is a pure high relativistic phenomenon (contraction of length), where a charged particle emits radiation when it passes close to the edge of a dielectric medium. To produce ODR, there is a condition to fulfill between the distance from the edge to the beam (h), the beam energy (g) and the wavelength () of the radiation you like to produce. h g 2 Questions: What will be the required minimum distance from the edge of the slit to the beam in order to produce visible photons (550nm wavelength) Following the mentioned formula, the limit to produce 550nm photons corresponds to 8mm Is that distance looks reasonable, Would you think it can be used at lower beam energies Without emittance dilution, the beam size shrinks with the beam energy and 8mm is quite large with respect to the maximum transverse beam size (some 100mm) you will find at these beam energies. In principle, 1mm would be still good enough and it would correspond to 6.25GeV electrons.

Exercise You are responsible for the purchase of the streak camera and you should define what are the parameter of the streak camera to buy. You were told that you need a minimum of 2points per sigma in order to clearly measure a Gaussian bunch length. Question: Assuming that your MCP-CCD system is 1cm wide in vertical and have 500pixels, what will be the minimum sweep speed (in ps/mm) of the streak tube in order to measure the bunch length in your linac The spatial resolution of the MCP-CCD system corresponds to 1/500 = 20 mm per pixel. Your bunch length is 4ps sigma. Assuming that you need 2 pixels per sigma to measure the bunch length, you will need a sweep speed equivalent to 4ps/2pixels = 4ps/40mm = 100ps/mm The required sweep speed is 100ps/mm

Bunch Frequency For a given beam intensity, The shorter the bunch, the broader the bunch frequency spectrum Solid: Dash: Dash-dot: σ z = 1 ps σ z = 2 ps σ z = 3 ps Train of 5 bunches @3GHz and σ z = 2 ps The bandwidth of radiation produced from a Gaussian bunch, given by its Fourier transform, extends into the terahertz region for the ultra-short bunches 10 microns ~ 33.3femtoseconds ~ 30 THz From the measured frequency spectrum you can reconstructed the bunch length more

Bunch Frequency by Coherent Radiation When the wavelength of the radiation is longer than the bunch length, it is known that the coherent effect occurs inside the bunch For a given beam intensity, the shorter the bunch, the broader the bunch frequency spectrum The longitudinal shapes of the electron bunch can be extracted by analyzing the power spectrum of the radiation Intensity of coherent radiation N 2 Coherent Transition Radiation (CTR) P. Kung et al, Physical review Letters 73 (1994) 96 90fs, 32MeV beam Coherent Diffraction (CDR) B. Feng et al, NIM A 475 (2001) 492 497 ; A.H. Lumpkin et al, NIM A 475 (2001) 470 475 ; C. Castellano et al, Physical Review E 63 (2001) 056501 T. Watanabe et al, NIM A 437 (1999) 1-11 & NIM A 480 (2002) 315 327 more 700fs, 35MeV beam 470fs, 150MeV beam

Bunch Frequency by Coherent Radiation n! Michelson or Martin-Pupplet interferometer : The radiation is split in two bunches, one is delayed by a linear stage and the intensity of the recombined bunch is measured by two detectors (one for each polarization) The spectrum is obtained from the Fourier transform of the interferometer function 1 The polychromator enables to get the spectrum directly by a single shot. The radiation is deflected by a grating and resolved by the xx-channelsdetector array Limitations : Narrow dynamic range limited by the small bandwidth sensitivity of the system element (Grating, Beam splitter, ) Need cross calibrations more Resolution depends on the number of detectors (polychromator)

Exercise You did so well for the bunch length measurement in the linac that you are asked to provide some support to operate of the bunch compressors. The bunch compression is done using an accelerating structure and a magnetic chicane. A coherent diffraction radiation monitor is measuring the bunch frequency spectrum just downstream of the chicane. Coherent radiation monitor relies on the fact that the shorter the bunch the broader the bunch frequency spectrum. Accelerating Field E(t) 2 1 t Questions: On the figure, there are two different settings of the klystron phase. For these two cases, draw what will be the trajectory of electrons sitting at the head and at the tail of the bunch for each case? On the CDR monitor, two different bunch frequency spectra have been measured. Choose which spectra corresponds to which phase settings Are you happy with the performance of the bunch compressor? if not what will you modify to have a better result

Exercise Questions: On the figure, there are two different settings of the klystron phase. For these two cases, draw what will be the trajectory of electrons sitting at the head and at the tail of the bunch for each case? Case 1 Case 2 On the CDR monitor, two different bunch frequency spectra have been measured. Choose which spectra corresponds to which phase settings In case 1, the beam head is accelerated more than the tail such that it experiences a short trajectory than the tail in the chicane. Therefore the bunch gets longer. In case 2, the beam head and tail have the same energy so they will also have the same trajectory, the bunch length will remain the same. On the CDR you will measure a broader spectrum for the shortest bunch, which will be with the present setting for case 2. Are you happy with the performance of the bunch compressor? if not what will you modify to have a better result The bunch compressor is stretching the bunch at the moment and you are not satisfied, you suggest then to change the phase of the klystron in order to bring the bunch on the negative slope of the. This will correspond to bunch compression, accelerating more the tail than the head of the bunch.

by Deflecting Cavity 1 The Deflector can be seen as a relativistic streak tube. The time varying deflecting field of the cavity transforms the time information into a spatial information The bunch length is then deduced measuring the beam size at a downstream position using a screen or (LWS) R. Akre et al, SLAC-PUB-8864, SLAC-PUB-9241, 2002 300mm, 28GeV beam using a S-band deflector more Can extract even more information than the bunch length ex: slice emittance and intra bunch energy spread

by Deflecting Cavity more

Exercise With your new success, you really become an well recognized expert and the calibration of the deflector has been modified. You have been asked to calibrate the monitor. The deflector is working at 3GHz and for a maximum deflection (+/-90degree phase difference) the beam position on the screen changes by 5mm. Deflecting Field E(t) Zero - crossing -90 2 y 2 y 0 2 z +90 t Questions: If the bunch is placed at the zero-crossing of the deflector. What happen to the beam position and to the beam size? The beam position remains unchanged but the beam size increases If the natural beam size (no ) on the screen is 10mm, what will be approximately the size increase for zero-crossing if the bunch is 1ps long. The relation between the bunch length the beam size on the screen with and without power is given by the following expression. 3 GHz frequency corresponds to 333ps time period. The period corresponds to 360degrees of phase variation such that 90degrees @ 3GHz is equivalent to 83.25ps. The beam is moved by 5mm on the screen for a 90degrees klystron phase and would correspond to a time delay corresponding to 83.25ps 1ps is then equivalent to 60mm that will be added in quadrature to the 10mm of the original beam size. So the beam size will be then 60.8microns

Electro Optic Sampling n! This method is based on the polarization change of a laser beam which passes through a crystal itself polarized by the electrons electric field Bunch length is reconstructed by measuring the intensity of the polarization change as a function of laser timing A. M. MacLeod et al, Physical Review Letters 85 (2000) 3404 Using 12fs Ti:Al2O3 laser at 800nm and ZnTe crystal 0.5mm thick and a beam of 46MeV, 200pC, 2ps. more Limitations : Presence of phonon (5.3THz for ZnTe) can distort the measurement for bunch length < 200fs Radiation hardness (no problem observed up to now) Jitter of the laser- synchronization

Sampling Techniques more

Electro Optic based bunch length monitors 1. Sampling: multi-shot method arbitrary time window possible 2. Chirp laser method, spectral encoding): laser bandwidth limited~ 250fs I. Wilke et.al., PRL Vol.88, No.12 3. Spatial encoding: imaging limitation ~ 30-50 fs A. Cavalieri, et. al., PRL. 94, 114801 4. Temporal decoding: laser pulse length limited ~ 30fs S.P. Jamison, et.al., PRL Vol.93, No.11 more

How do we measure short bunches Optical radiation Cherenkov radiation X Optical Transition Radiation X Optical Diffraction Radiation X Streak camera X X > 200fs Coherent radiation Interferometry X X Polychromator X X Deflector X X X 1 n! Limitations Electro Optic Method Sampling X X X Jitter Spectral decoding X X X > 200fs Spatial decoding X X X > 50fs Temporal decoding X X X > 50fs

Exercise You are now working on the design of 4 th generation light source and you have been asked to define the several techniques to measure bunch length all along the machine. Choose at least one location where the following detector could be used along the machine. - ODR with a streak camera - deflector - Coherent diffraction radiation - EO spatial decoding 150MeV 2.8ps 250MeV 630fs 4.5GeV 75fs 20GeV

LCLS Machine Schematic Courtesy of P. Krejcik