APPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate)

Similar documents
Method Development for Chiral LC/MS/MS Analysis of Acidic Stereoisomeric Pharmaceutical Compounds with Polysaccharide-based Stationary Phases

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate)

Gemini-NX Performance paired with Axia Technology

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction

Your Reversed Phase Method

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography

Quick and Simple Cleanup for. Medicinal Chemistry. It s BIG.

APPLICATIONS TN Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12

The Standard for ph Method Development

Application Note. Authors. Abstract. Pharmaceuticals

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes

ChromegaChiral TM CSP Media and Columns

ChromegaChiral TM CSP Media and Columns

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

35 % OFF HPLC. The Ultimate Guide to

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

Optical Isomer Separation Columns and Packing Materials

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

LC-MS compatible Separation of the Fungicide Spiroxamine

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

4. Place a 20 ml VOA vial in position 1 of the tray. 5. Place a 6 ml C18-E cartridge in position 1 of the carousel.

770-9P. Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

ANALYSIS OF BASIC COMPOUNDS

mau 200 ph min

[ Care and Use Manual ]

Chiral Separation Using SFC and HPLC

Fast, Accurate Environmental Testing

LC Technical Information

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development

Reversed Phase Solvents

Setting the Standard for ph Method Development

Enhance Resolution FOR POLYMER ANALYSIS, Guaranteed *

Journal of Chromatography A

Leave Your Footprint!

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Separation of Chiral Pesticides by SFC and HPLC

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns

CHAPTER 1 Role of Bioanalytical Methods in Drug Discovery and Development

TCI Chiral HPLC Column

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

Setting the Standard for ph Method Development

1.7µm Fortis C18 UHPLC Columns

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

Enantiomer Separation of Chiral Acids on CHIRALPAK AX-QN and CHIRALPAK AX QD

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Chiral Method Development in LC/MS Using Macrocyclic Glycopeptide CSPs

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

FAQ's. 1 - Which column would be the most appropriate for my application?

CHROMTECH - CHIRAL HPLC COLUMNS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

Multi-Channel SFC System for Fast Chiral Method Development and Optimization

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

ChromegaChiral TM Columns. The right choice for chiral purification

PhenogelTM Non-Aqueous GPC/SEC Columns

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

6 Optical Isomer Separation Columns

SEPARATION OF FLURBIPROFEN AND IBUPROFEN ENANTIOMERS ON A CHIRAL STATIONARY PHASE USING SUPERCRITICAL FLUIDS

Determination of Pharmaceuticals in Environmental Samples

C18 Column. Care & Use Sheet

penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Basic Principles for Purification Using Supercritical Fluid Chromatography

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Improved Automated Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

Practicing Chiral Chromatography in Your Mobile Phase Comfort Zone

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Sample Preparation Method Development for Complex Matrices Such as Foods by QuEChERS and Solid Phase Extraction (SPE)

LIQUID CHROMATOGRAPHY

IN QUALITATIVE ANALYSIS,

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Astec CHIROBIOTIC. Macrocyclic Glycopeptide-Based Chiral HPLC Phases

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

HILIC Method Development in a Few Simple Steps

Quantitative Analysis and Identification of Migrants in Food Packaging Using LC-MS/MS

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

columns IonPac AS17-C Anion Exchange Column

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Transcription:

T-1079 APPLICATI Method Development for Reversed Phase Chiral LC/M/M Analysis of tereoisomeric Pharmaceutical Compounds with Polysaccharide-based tationary Phases Philip J. Koerner, Kari Carlson, Liming Peng, wapna Jayapalan, and Tivadar Farkas Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 UA Five different Lux polysaccharide-based chiral stationary phases were explored in the reversed phase elution mode using mobile phases consisting of 0.1 % formic acid in acetonitrile or methanol to demonstrate the feasibility of LC/M/M analysis of a variety of acidic pharmaceutical racemates. Introduction Developing simple and straightforward reversed phase chiral LC separations coupled with highly sensitive M detection is a challenging requirement for conducting drug metabolism and pharmacokinetic studies of stereoisomers. Polysaccharide derivatives are the most widely used chiral stationary phases (CP) due to their wide chiral recognition and high loading capacity. As normal phase is favorable for their principal mechanism of chiral recognition hydrogen bonding interaction the majority of chiral separations with polysaccharide phases are performed in normal phase using hexane and alcohol modifiers as mobile phase components. However, these mobile phases are highly flammable and are not compatible with atmospheric pressure ionization (API) M ion sources. The current research was extended to investigate the effectiveness of an acidic mobile phase for the separation and detection of acidic stereoisomers by EI or APCI LC/M/M and for method development of these applications. Experimental Analytes: 15 acidic compounds of pharmaceutical interest were analyzed. The structures are shown in Figure 2 and the M ionization and MRM transitions monitored are listed in Table 1. Columns: Lux 3 μm Cellulose-1, 150 x 2.0 mm Lux 3 μm Cellulose-2, 150 x 2.0 mm Lux 3 μm Amylose -2, 150 x 2.0 mm Lux 5 μm Cellulose-4, 250 x 4.6 mm Lux 5 μm Cellulose-3, 250 x 4.6 mm Kinetex 2.6 μm C18, 50 x 2.1 mm (used for achiral analysis) (3 μm, 150 x 2.0 mm) or 1.0 ml/min (5 μm, 250 x 4.6 mm) flow split to 0.25 ml/min into M/M Injection Volume: 5 μl (150 x 2.0 mm) or 20 μl (250 x 4.6 mm) Mobile Phase: 1. 0.1 % Formic acid in Acetonitrile or Methanol 2. 5 mm Ammonium bicarbonate in Acetonitrile or Methanol (achiral analysis) 3. 5 mm Ammonium formate in Acetonitrile or Methanol (achiral analysis) 4. 5 mm Ammonium acetate in Acetonitrile or Methanol (achiral analysis) Instrument: HPLC ystem: Agilent 1200 series equipped with binary pump and autosampler (Agilent, Palo Alto, CA) M Detector: AB CIEX 4000 LC/M/M Turbo V source with EI or APCI probe Turbolonpray EI or APCI in Positive or egative Ion Mode; MRM Results and Discussion Chiral LC/M/M Experiments Five different polysaccharide-based chiral stationary phases (Lux Cellulose-1, Lux Cellulose-2, Lux Cellulose-3, Lux Cellulose-4, and Lux Amylose-2 (Figure 1) were explored in the reversed phase elution mode for the separation of a variety of acidic compounds of pharmaceutical interest in mobile phases consisting of 0.1 % formic acid in acetonitrile or methanol and M/M detection. Figure 1. tructures of Polysaccharide-based Chiral tationary (CPs) Phases Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate) CH HC CH Lux Cellulose-1 Cellulose tris (3,5-dimethylphenylcarbamate) Lux Amylose-2 Amylose tris (5-chloro-2-methylphenylcarbamate) HC HC CH CH CH CH Lux Cellulose-3 Cellulose tris-(4-methylbenzoate) C Me Me C C Me Page 1 of 8

APPLICATI Table 1. MRM Transitions and Concentrations of Acidic Racemates Compound I and MRM Conc.* Compounds I and MRM Conc.* Ibuprofen EI - 205.1/160.1 100 Abscisic acid APCI - 263.0/152.7 50 Flurbiprofen EI - 243.0/198.7 50 Mecoprop EI - 214.1/141.7 50 uprofen EI + 261.1/111.0 50 Ketorolac EI - 254.0/209.8 EI + 256.2/105.0 Fenoprofen APCI - 241.0/196.8 100 Etodolac EI - 286.1/242.0 50 Carprofen APCI - 272.8/228.8 100 Warfarin EI - 307.1/160.9 EI + 309.2/163.1 Indoprofen EI + 282.1/236.1 50 EI - 420.1/77.9 50 Proglumide EI - 333.1/120.9 50 Trichlormethiazide EI - 377.8/241.6 50 1-(Phenylsulfonyl)- 3-indoleboronic acid EI - 300.0/209.8 100 * Conc. (ng/ml) 50 50 election of Mobile Phase Additives As acidic analytes are present as anions in mobile phases of neutral ph their retention is not favorable on polysaccharide-based CPs. Early elution and poor or no enantioseparation can result under these conditions. Acidic mobile phase additives are often required to suppress the dissociation of acidic analytes, resulting in increased retention and improved enantioselectivity. Three volatile organic acids, (trifluoroacetic acid (TFA, pk a 0.59), formic acid (FA, pk a 3.75), and acetic acid (HAc, pk a 4.76) were evaluated on Lux Cellulose-1 and Lux Amylose-2 CPs as acidic additives. In general, these additives provide similar enantioresolution for weakly acidic racemates (Figures 3A-3C) while the stronger acidic additive (TFA) performs better for the stronger acidic racemates (Figures 3D 3F). Formic acid provides comparable enantioseparations and peak shapes to TFA. Considering the memory effect of TFA commonly experienced on polysaccharide-based CPs and its ion suppressing tendency in M detection, formic acid was selected in preference over TFA in reversed phase mobile phase for the chiral separation and M/M detection of acidic racemates. Figure 2. Molecular tructures of Acidic Racemates H H H F H H H H Ibuprofen Flurbiprofen uprofen Fenoprofen Carprofen Indoprofen H H H H H H B H Proglumide Abscisic Acid Mecoprop Ketorolac 1-(Phenylsulfonyl)-3- indoleboronic acid H H H 3 C H Etodolac H H H CF 3 H H H 2 H 2 Warfarin Trichlormethiazide Page 2 of 8

APPLICATI Figure 3. Effect of Acidic Additives on the Enantioseparation of Acidic Racemates in Reversed Phase Lux 3 µm Cellulose-1 Flurbiprofen Lux 3 µm Amylose-2 A. Acetonitrile / Acetic D. Acetic B. E. Formic Column: As noted Detection: UV @ 220 nm App ID 19326 C. Trifluoroacetic acid (TFA) (40:60) F. Trifluoroacetic App ID 19327 Effect of Mobile Phase Additives The LC/M/M responses of acidic racemates with EI negative (EI-) mode in 5 mm ammonium formate, 5 mm ammonium acetate, and 5 mm ammonium bicarbonate containing mobile phases with either acetonitrile or methanol as organic modifier using an achiral column (Kinetex 2.6 µm C18) were compared to responses in 0.1 % formic acid (Figures 4 and 5). The results show M/ M responses using 0.1 % formic acid in acetonitrile or methanol are comparable to the responses using the other acid modifiers in EI- mode, with the exception of carprofen which showed poor response with all of the acidic mobile phase additives. This shows that 0.1 % formic acid as acidic mobile phase additive is fully compatible with M/M detection and can be implemented as the first choice for mobile phase additive. Figure 4. LC/M/M Responses of Acidic Racemates in EI- with Different Additives and Methanol 1500000 Effect of rganic Modifier on Chiral Resolution Acetonitrile or methanol was the organic modifier used in chiral reversed phase HPLC. Decreasing the eluting strength of the mobile phase by decreasing the percentage of acetonitrile or methanol in the mobile phase will increase retention and resolution (Figure 6). However, once enantiomers elute later than about 10 minutes with only partial resolution, baseline separation can be rarely achieved by further decreasing the % organic modifier in the mobile phase. In our study, acetonitrile was more successful than methanol in providing chiral resolution on Lux CPs in reversed phase (RP) mode (Figure 8), typically yielding sharper and narrower peaks. 1250000 250000 1000000 200000 150000 750000 500000 250000 0 Warfarin Etodolac Ibuprofen 100000 50000 Fenoprofen Flurbiprofen Proglumide 1-(P)-3-indoleboronic Ketorolac Fenoprofen Flurbiprofen Proglumide 1-(P)-3-indoleboronic Ketorolac Mecoprop Carprofen 0 Mecoprop Carprofen 0.1 % Formic acid / Methanol 5 mm Ammonium formate / Methanol 5 mm Ammonium bicarbonate / Methanol 5 mm Ammonium acetate / Methanol Page 3 of 8

APPLICATI Figure 5. LC/M/M Responses of Acidic Racemates in EI- with Different Additives and Methanol 1250000 1000000 750000 5 mm Ammonium bicarbonate / Acetonitrile 5 mm Ammonium formate / Methanol 0.1 % Formic acid / Acetonitrile 5 mm Ammonium acetate / Acetonitrile 500000 Ibuprofen Etodolac Ketorolac Mecoprop Carprofen 1-(P)-3-indoleboronic 250000 0 Warfarin Etodolac Fenoprofen Flurbiprofen Ibuprofen Proglumide Ketorolac Mecoprop Carprofen 1-(P)-3-indoleboronic Figure 6. Effect of Acidic Additives on the Enantioseparation of Acidic Racemates in Reversed Phase Proglumide Ibuprofen Lux 3 µm Cellulose-1 Lux 5 µm Cellulose-3 Flow Rate: 1 ml/min Dimensions: 250 x 4.6 mm Acetonitrile / 0.1% Formic Acetonitrile / 0.1% Formic acid (50:50) Column: As noted Dimensions: As noted Flow Rate: As noted Temperature: Ambient Acetonitrile / 0.1% Formic acid (30:70) App ID 19328 App ID 19329 Page 4 of 8

APPLICATI Chiral LC/M/M Applications Figures 7-11 demonstrate 15 chiral separations on several different Lux chiral stationary phases. APCI negative (APCI-) mode was employed for the M/M detection of carprofen, abscisic acid, and fenoprofen as it provides much better M/M signals than EI- for these acidic racemates. EI positive (EI+) mode was used for the M/M detection of suprofen and gave slightly improved signal intensity for warfarin and ketorolac versus EI- (Figure 10). Most compounds evaluated here eluted in less than 10 min with baseline resolution in mobile phases of various elution strength. The results show that Lux Cellulose-3 was most successful in separating acidic racemates (ten racemates), especially nonsteroidal anti-inflammatory drugs, with good linearity (R 2 > 0.997) from 1.0 to 1000 ng/ml. Figure 7. Enantioseparations in Reversed Phase on Lux 3 µm Cellulose-1 with Acetonitrile App ID 19330 Acetonitrile / 0.1% Formic ample: Etodolac Acetonitrile / 0.1% Formic ample: Proglumide App ID 19334 App ID 19331 Acetonitrile / 0.1% Formic ample: Warfarin Acetonitrile / 0.1% Formic ample: Carprofen App ID 19335 Column: Lux 3 µm Cellulose-1 Part o.: 00F-4458-B0 App ID 19332 Acetonitrile / 0.1% Formic acid / (30:70) ample: Trichlormethiazide Acetonitrile / 0.1% Formic acid (40:60) ample: App ID 19336 App ID 19333 Acetonitrile / 0.1% Formic acid (30:70 ample: 1-(Phenylsulfonyl)- 3-indoleboronic acid Acetonitrile / 0.1% Formic acid (30:70) App ID 19337 Figure 8. Enantioseparations on Lux 3 µm Cellulose-2 with Acetonitrile or Methanol as Modifier App ID 19338 Acetonitrile / Formic ample: Proglumide Methanol / 0.1 % Formic acid (70:30) ample: Proglumide App ID 19339 Acetonitrile / Formic Methanol / 0.1 % Formic acid (70:30) App ID 19340 Acetonitrile / Formic ample: Methanol / 0.1 % Formic acid (70:30) ample: Column: Lux 3 µm Cellulose-2 Part o.: 00F-4456-B0 App ID 19341 Acetonitrile / Formic ample: 1-(Phenylsulfonyl)- 3-indoleboronic acid Methanol / 0.1 % Formic acid (70:30) ample: 1-(Phenylsulfonyl)- 3-indoleboronic acid App ID 19342 Acetonitrile / Formic ample: Etodolac Methanol / 0.1 % Formic acid (70:30) ample: Etodolac Page 5 of 8

APPLICATI Figure 9. Enantioseparations on Lux 5 µm Cellulose-4 with Acetonitrile App ID 19343 App ID 19344 ample: 1-(Phenylsulfonyl)- 3-indoleboronic acid acid (50:50) ample: Etodolac acid (40:60) Formic ample: Warfarin App ID 19347 App ID 19348 Column: Lux 5 µm Cellulose-4 Dimensions: 250 x 4.6 mm Part o.: 00G-4491-E0 Flow Rate: 1 ml/min Injection Volume: 20 µl App ID 19346 App ID 19345 ample: Proglumide acid (50:50) ample: acid (30:70) ample: Trichlormethiazide acid (80:20) ample: App ID 19350 App ID 19349 Figure 10. Enantioseparations in Reversed Phase on Lux 3 µm Amylose-2 with Acetonitrile egative Ion Mode Positive Ion Mode App ID 19351 Column: Lux 3 µm Amylose-2 Part o.: 00F-4471-B0 App ID 19354 App ID 19352 ample: Warfarin Formic ample: uprofen ample: Warfarin Formic ample: Flurbiprofen App ID 19353 Page 6 of 8

APPLICATI Figure 11. Enantioseparations in Reversed Phase on Lux 5 µm Cellulose-3 with Acetonitrile Modifier App ID 19355 ample: Mecoprop ample: Flurbiprofen App ID 19356 App ID 19357 ample: uprofen (EI + ) App ID 19358 Column: Lux 5 µm Cellulose-3 Dimensions: 250 x 4.6 mm Part o.: 00G-4493-E0 Flow Rate: 1 ml/min App ID 19360 App ID 19362 App ID 19359 ample: Etodolac ample: Fenoprofen (APCI - ) acid (95:5) ample: Ibuprofen acid (80:20) ample: Indoprofen ample: Abscisic acid (APCI - ) acid (80:20) ample: Proglumide App ID 19361 App ID 19364 App ID 19363 Injection Volume: 20 µl Conclusions The chiral LC/M/M analysis of fifteen different acidic racemates are successfully demonstrated on the polysaccharide-based CPs Lux Cellulose-1, Lux Cellulose-2, Lux Cellulose-3, Lux Cellulose-4, and Lux Amylose-2 in reversed phase (RP) elution mode. Formic acid is a good first choice for an acidic RP mobile phase additive as it leads to increased retention and improved enantioselectivity for acidic enantiomers and is also compatible with M/M detection. Increasing the percentage of organic modifier (acetonitrile or methanol) in the RP mobile phase has the expected effect of decreasing retention and enantioselectivity. Adjusting the organic modifier content of the mobile phase is therefore essential to optimizing chiral resolution. Page 7 of 8

APPLICATI Australia t: 02-9428-6444 f: 02-9428-6445 auinfo@phenomenex.com Austria t: 01-319-1301 f: 01-319-1300 anfrage@phenomenex.com Belgium t: +31 (0)30-2418700 f: +31 (0)30-2383749 beinfo@phenomenex.com Canada t: (800) 543-3681 f: (310) 328-7768 info@phenomenex.com Denmark t: 4824 8048 f: 4810 6265 nordicinfo@phenomenex.com Finland t: (09)4789 0063 f: +45 4810 6265 nordicinfo@phenomenex.com France t: 01 30 09 21 10 f: 01 30 09 21 11 franceinfo@phenomenex.com Germany t: 06021-58830-0 f: 06021-58830-11 anfrage@phenomenex.com Ireland t: 01 247 5405 f: +44 1625-501796 eireinfo@phenomenex.com Italy t: 051 6327511 f: 051 6327555 italiainfo@phenomenex.com Luxembourg t: +31 (0)30-2418700 f: +31 (0)30-2383749 nlinfo@phenomenex.com Mexico t: (55) 5018 3791 f: (310) 328-7768 tecnicomx@phenomenex.com The etherlands t: 030-2418700 f: 030-2383749 nlinfo@phenomenex.com ew Zealand t: 09-4780951 f: 09-4780952 nzinfo@phenomenex.com orway t: 810 02 005 f: +45 4810 6265 nordicinfo@phenomenex.com Puerto Rico t: (800) 541-HPLC f: (310) 328-7768 info@phenomenex.com United Kingdom t: 01625-501367 f: 01625-501796 ukinfo@phenomenex.com All other countries: Corporate ffice UA t: (310) 212-0555 f: (310) 328-7768 info@phenomenex.com Lux rdering Information 3 μm Analytical Columns (mm) ecurityguard Cartridges (mm) www.phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex UA, International Department at international@phenomenex.com 50 x 2.0 150 x 2.0 50 x 4.6 100 x 4.6 150 x 4.6 250 x 4.6 4 x 2.0* 4 x 3.0* Phases /10pk /10pk Cellulose-4 00B-4490-B0 00F-4490-B0 00B-4490-E0 00D-4490-E0 00F-4490-E0 00G-4490-E0 AJ0-8626 AJ0-8627 Cellulose-3 00B-4492-B0 00F-4492-B0 00B-4492-E0 00D-4492-E0 00F-4492-E0 00G-4492-E0 AJ0-8621 AJ0-8622 Cellulose-2 00B-4456-B0 00F-4456-B0 00B-4456-E0 00D-4456-E0 00F-4456-E0 00G-4456-E0 AJ0-8398 AJ0-8366 Cellulose-1 00B-4458-B0 00F-4458-B0 00B-4458-E0 00D-4458-E0 00F-4458-E0 00G-4458-E0 AJ0-8402 AJ0-8403 Amylose-2 00B-4471-B0 00F-4471-B0 00B-4471-E0 00D-4471-E0 00F-4471-E0 00G-4471-E0 AJ0-8471 AJ0-8470 5 µm emi-prep Columns (mm) ecurityguard Cartridges (mm) 150 x 10.0 250 x 10.0 10 x 10.0 Phases /3pk Cellulose-4 00F-4491-0 00G-4491-0 AJ0-8628 Cellulose-3 00F-4493-0 00G-4493-0 AJ0-8623 Cellulose-2 00F-4457-0 00G-4457-0 AJ0-8399 Cellulose-1 00F-4459-0 00G-4459-0 AJ0-8404 Amylose-2 00F-4472-0 00G-4472-0 AJ0-8472 for ID: 9-16 mm 5 μm Axia Packed Preparative Columns (mm) ecurityguard Cartridges (mm) 150 x 21.2 250 x 21.2 250 x 30 250 x 50 15 x 21.2** 15 x 30.0 + Phases /ea /ea Cellulose-4 00F-4491-P0-AX 00G-4491-P0-AX 00G-4491-U0-AX 00G-4491-V0-AX AJ0-8629 AJ0-8630 Cellulose-3 00F-4493-P0-AX 00G-4493-P0-AX 00G-4493-U0-AX 00G-4493-V0-AX AJ0-8624 AJ0-8625 Cellulose-2 00F-4457-P0-AX 00G-4457-P0-AX 00G-4457-U0-AX 00G-4457-V0-AX AJ0-8400 AJ0-8401 Cellulose-1 00F-4459-P0-AX 00G-4459-P0-AX 00G-4459-U0-AX 00G-4459-V0-AX AJ0-8405 AJ0-8406 Amylose-2 00F-4472-P0-AX 00G-4472-P0-AX 00G-4472-U0-AX 00G-4472-V0-AX AJ0-8473 AJ0-8474 *ecurityguard Analytical Cartridges require holder, Part o. : KJ0-4282 emiprep ecurityguard Cartridges require holder, Part o. : AJ0-7220 **PREP ecurityguard Cartridges require holder, Part o. : AJ0-8223 + PREP ecurityguard Cartridges require holder, Part o. : AJ0-8277 Terms and Conditions ubject to Phenomenex tandard Terms and Conditions, which may be viewed at http://www.phenomenex.com/termsandconditions. Trademarks Lux and Kinetex are registered trademarks of Phenomenex, Inc. in the United tates, European Union, and other jurisdictions. ecurityguard is a trademark of Phenomenex, Inc. Turbolonpray is a registered trademark and AB CIEX, API 3000, and Turbo V are trademarks of AB ciex Pte. Ltd. Disclaimer Comparative separations may not be representative of all applications. 2010 Phenomenex, Inc. All rights reserved. 20 µm Bulk Media for ID: 2.0 3.0 mm 3.2 8.0 mm 5 μm Analytical Columns (mm) ecurityguard Cartridges (mm) 50 x 2.0 50 x 4.6 100 x 4.6 150 x 4.6 250 x 4.6 4 x 2.0* 4 x 3.0* Phases /10pk /10pk Cellulose-4 00B-4491-B0 00B-4491-E0 00D-4491-E0 00F-4491-E0 00G-4491-E0 AJ0-8626 AJ0-8627 Cellulose-3 00B-4493-B0 00B-4493-E0 00D-4493-E0 00F-4493-E0 00G-4493-E0 AJ0-8621 AJ0-8622 Cellulose-2 00B-4457-B0 00B-4457-E0 00D-4457-E0 00F-4457-E0 00G-4457-E0 AJ0-8398 AJ0-8366 Cellulose-1 00B-4459-B0 00B-4459-E0 00D-4459-E0 00F-4459-E0 00G-4459-E0 AJ0-8402 AJ0-8403 Amylose-2 00B-4472-B0 00B-4472-E0 00D-4472-E0 00F-4472-E0 00G-4472-E0 AJ0-8471 AJ0-8470 for ID: 2.0 3.0 mm 3.2 8.0 mm 100 g 1 kg Phases Cellulose-1 04G-4473 04K-4473 Cellulose-2 04G-4464 04K-4464 Please inquire for 20 µm Lux Amylose-2, Cellulose-3 or Cellulose-4 media. for ID: 18 29 mm 30 49 mm If Lux analytical columns ( 4.6 mm ID) do not provide at least an equivalent or better separation as compared to a competing column of the same particle size, similar phase and dimensions, return the column with comparative data within 45 days for a FULL REFUD. T76320610_L Page 8 of 8