AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography

Similar documents
Your Reversed Phase Method

Gemini-NX Performance paired with Axia Technology

APPLICATIONS TN Separation and Quantitation of Physiologic Cobalamins (Vitamin B 12

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction

Quick and Simple Cleanup for. Medicinal Chemistry. It s BIG.

The Standard for ph Method Development

APPLICATIONS TN Lux Cellulose-2 or -4 Cellulose tris (3-chloro-4-methylphenylcarbamate) or (4-chloro-3-methylphenylcarbamate)

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate)

35 % OFF HPLC. The Ultimate Guide to

Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis

Enhance Resolution FOR POLYMER ANALYSIS, Guaranteed *

4. Place a 20 ml VOA vial in position 1 of the tray. 5. Place a 6 ml C18-E cartridge in position 1 of the carousel.

Fast, Accurate Environmental Testing

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

IN QUALITATIVE ANALYSIS,

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Sepax SRT -C, Zenix -C SEC Phases

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

PhenogelTM Non-Aqueous GPC/SEC Columns

[ Care and Use Manual ]

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Optimization of temperature-sensitive assays using the Spark Te-Cool

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

1.7µm Fortis C18 UHPLC Columns

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Superose High-performance Columns

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

ProPac WCX-10 Columns

MetWorks Metabolite Identification Software

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

The Challenge: Sepax SEC C-line columns!

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

New Product Update. HPLC Columns

Monitoring Protein PEGylation with Ion Exchange Chromatography

ApplicationNOTE Abstract

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

Take Your Food Testing to the Next Level

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

HiTrap HIC Selection Kit

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Human C-reactive protein ELISA using Sword Peroxidase Reagents

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Fast, Effective XPS Point Analysis of Metal Components

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns

2017 Source of Foreign Income Earned By Fund

of mass spectrometry

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Thermo Scientific. Anion-Exchange Column

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Enhancement of Linearity and Response in Charged Aerosol Detection

Setting the Standard for ph Method Development

This document is a preview generated by EVS

Sample Preparation Method Development for Complex Matrices Such as Foods by QuEChERS and Solid Phase Extraction (SPE)

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis

protein interaction analysis bulletin 6300

Introduction to Fourier Transform Infrared Spectroscopy

Microbial DNA qpcr Multi-Assay Kit Clostridium perfringens Pathogenicity

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

LC Technical Information

Definitive EtG/EtS LC-MS/MS Analysis:

Introduction to Fourier Transform Infrared Spectroscopy

Advances in Sample Preparation for Accelerated Solvent Extraction

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

Corporate Governance, and the Returns on Investment

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development

Setting the Standard for ph Method Development

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Transcription:

Biologics Workflow AGGREGATE ANALYSIS by Size Exclusion Chromatography New biozen SEC columns provide: High efficiency on both HPLC and UHPLC Extreme inertness and robustness Finely tuned high and low MW separation windows PLUS! Biocompatible titanium hardware minimizes priming and reproducibility concerns! www.phenomenex.com/biozen

One Particle Platform With mab aggregate often at very low levels (<0.1 % by peak area compared to monomer) and fragment separation a requirement, adequate resolution and peak shape have become even more crucial to method outcomes. To address this need, the robust set of biozen SEC columns were developed with a combination of UHPLC efficiency and higher sensitivity, to drive resolution and identification of even lower level targets. High Efficiency Excellent Inertness Increased Sensitivity Thermally Modified Fully Porous Exceptional Quality and Robustness Best choice for HMW aggregates! biozen SEC-2 1.8 µm Extremely inert, high density fully porous particle with high efficiency and low molecular weight (LMW) separation range of 1 k 450 kda. biozen SEC-3 1.8 µm Extremely inert, high density fully porous particle with high efficiency and high molecular weight (HMW) separation range of 10 k 700 kda. Biocompatible Hardware Biocompatible Titanium Frit WOOHOO! biozen SEC columns come in titanium BioTi HPLC/UHPLC hardware that curtails lengthy priming steps, unwanted secondary interactions, problematic carryover, and recovery issues between injection to detection. Traditional Stainless Steel Biocompatible Titanium 2

Overlaid Successive Injections Protein Priming Comparison biozen Titanium BioTi Hardware Traditional Stainless Steel mau 30 25 20 15 10 5 0 App ID 24683 mau 30 25 20 15 10 5 0 Injection: 20 15 10 5 2 Multiple injections needed for priming. 3 4 5 6 min 3 4 5 6 min Conditions for both columns: Aggregate Analysis by Size Exclusion Adalimumab Trastuzumab HMW Dimer HMW Dimer App ID 24685 App ID 24684 App ID 24713 Column: biozen 1.8 μm SEC-3 Dimension: 150 x 4.6 mm Mobile Phase: 100 mm Sodium Phosphate Buffer (ph 6.8) Flow Rate: 0.3 ml/min Temperature: Ambient Detection: UV @ 280 nm Sample: 1. g-globulin 2. Ovalbumin Conditions same for both samples: Column: biozen 1.8 μm SEC-3 Dimension: 300 x 4.6 mm Part No.: 00H-4772-E0 Mobile Phase: 50 mm Dipotassium phosphate + 100 mm Sodium sulphate (ph 6.8) Flow Rate: 0.2 ml/min Temperature: 25 C Detection: UV @ 280 nm Sample: As Noted 3

Aggregate Analysis by Size Exclusion Rituximab HMW Aggregates Dimer Fragment App ID 24683 Cetuximab High aggregate recovery! HMW Fragment App ID 24763 Conditions same for all samples: Column: biozen 1.8 μm SEC-3 Dimension: 300 x 4.6 mm Part No.: 00H-4772-E0 Mobile Phase: 50 mm Dipotassium phosphate + 100 mm Sodium sulphate (ph 6.8) Flow Rate: 0.2 ml/min Temperature: 25 C Detection: UV @ 280 nm Sample: As Noted 4

Aggregate Analysis by Size Exclusion Infliximab Dimer App ID 24764 ADC Analysis Herceptin - mcmmaf High efficiency particle provides excellent, sharp peak shape for a large range of biologics App ID 24682 Conditions same for all samples: Column: biozen 1.8 μm SEC-3 Dimension: 300 x 4.6 mm Part No.: 00H-4772-E0 Mobile Phase: 50 mm Dipotassium phosphate + 100 mm Sodium sulphate (ph 6.8) Flow Rate: 0.2 ml/min Temperature: 25 C Detection: UV @ 280 nm Sample: As Noted Acknowledgment We would especially like to thank Colin McKee and ADC Biotechnology LTD for their support and ADC samples for this application. 5

Biocompatible Column/System Protection The easiest way to extend column performance and minimize costly system and detector upkeep is to prevent contaminants and particulates from getting into and past your LC column with a guard system. SecurityGuard guard cartridge systems provide this protection and truly make it easy to acquire this benefit on both HPLC and UHPLC systems. SecurityGuard ULTRA Guard Cartridge System with Titanium Contaminants Trapped New Titanium Frit Material Chamber Compounds of Interest Contaminants and Particulates Cartridge Holder From Injector SecurityGuard ULTRA UHPLC Column to Detector * Cartridge schematic not drawn to scale Ensure Protein Recovery with Biocompatible Accessories! Certified Vial Products Phenex Syringe Filters PES membranes offer fast-flow and ultra-low protein binding www.phenomenex.com/sffinder Verex Vials, Caps, and Kits Wide-range of certified vial and cap products to ensure precision www.phenomenex.com/vialfinder 6

biozen Column Selection Peptide Mapping biozen Peptide PS-C18 biozen Peptide XB-C18 Glycan Analysis biozen Glycan Intact and Fragment Analysis biozen Intact C4 biozen Intact XB-C8 Peptide Quantitation biozen Peptide PS-C18 biozen Peptide XB-C18 Aggregation Total mab Intact Mass Average DAR ADC biozen SEC-3 biozen SEC-2 biozen Intact C4 biozen Intact XB-C8 biozen SEC-3 biozen Intact XB-C8 Product Ordering Information biozen Products - Powered by Biocompatible Hardware biozen Columns (mm) Biocompatible Guard Cartridges 100 x 2.1 150 x 2.1 for 2.1 mm Holder /3pk ea biozen 2.6 μm Glycan 00D-4773-AN 00F-4773-AN AJ0-9800 AJ0-9000 50 x 2.1 150 x 2.1 for 2.1 mm Holder /3pk ea biozen 1.6 μm Peptide PS-C18 00B-4770-AN 00F-4770-AN AJ0-9803 AJ0-9000 50 x 4.6 150 x 4.6 for 4.6 mm Holder /10pk /kit biozen 3 μm Peptide PS-C18 00B-4771-E0 00F-4771-E0 AJ0-7606 KJ0-4282 50 x 2.1 150 x 2.1 for 2.1 mm Holder /3pk ea biozen 1.7 μm Peptide XB-C18 00B-4774-AN 00F-4774-AN AJ0-9806 AJ0-9000 50 x 2.1 150 x 2.1 250 x 2.1 50 x 4.6 150 x 4.6 for 2.1 mm for 4.6 mm Holder /3pk /3pk ea biozen 2.6 μm Peptide XB-C18 00B-4768-AN 00F-4768-AN 00G-4768-AN 00B-4768-E0 00F-4768-E0 AJ0-9806 AJ0-9808 AJ0-9000 50 x 2.1 150 x 2.1 50 x 4.6 150 x 4.6 for 2.1 mm for 4.6 mm Holder /3pk /3pk ea biozen 3.6 μm Intact C4 00B-4767-AN 00F-4767-AN 00B-4767-E0 00F-4767-E0 AJ0-9809 AJ0-9811 AJ0-9000 biozen 3.6 μm Intact XB-C8 00B-4766-AN 00F-4766-AN 00B-4766-E0 00F-4766-E0 AJ0-9812 AJ0-9814 AJ0-9000 150 x 4.6 300 x 4.6 for 4.6 mm Holder /3pk ea biozen 1.8 μm SEC-2 00F-4769-E0 00H-4769-E0 AJ0-9850 AJ0-9000 biozen 1.8 μm SEC-3 00F-4772-E0 00H-4772-E0 AJ0-9851 AJ0-9000 If biozen columns in this brochure do not provide at least equivalent separations to a competing column of the same phase, particle size, and dimensions, send in your comparative data within 45 days and keep the column for FREE! 7

Biologics Workflow AGGREGATE ANALYSIS by Size Exclusion Chromatography Australia t: +61 (0)2-9428-6444 f: +61 (0)2-9428-6445 auinfo@phenomenex.com Austria t: +43 (0)1-319-1301 f: +43 (0)1-319-1300 anfrage@phenomenex.com Belgium t: +32 (0)2 503 4015 (French) t: +32 (0)2 511 8666 (Dutch) f: +31 (0)30-2383749 beinfo@phenomenex.com Canada t: +1 (800) 543-3681 f: +1 (310) 328-7768 info@phenomenex.com China t: +86 400-606-8099 f: +86 (0)22 2532-1033 cninfo@phenomenex.com Denmark t: +45 4824 8048 f: +45 4810 6265 nordicinfo@phenomenex.com Finland t: +358 (0)9 4789 0063 f: +45 4810 6265 nordicinfo@phenomenex.com France t: +33 (0)1 30 09 21 10 f: +33 (0)1 30 09 21 11 franceinfo@phenomenex.com Germany t: +49 (0)6021-58830-0 f: +49 (0)6021-58830-11 anfrage@phenomenex.com India t: +91 (0)40-3012 2400 f: +91 (0)40-3012 2411 indiainfo@phenomenex.com Ireland t: +353 (0)1 247 5405 f: +44 1625-501796 eireinfo@phenomenex.com Italy t: +39 051 6327511 f: +39 051 6327555 italiainfo@phenomenex.com Luxembourg t: +31 (0)30-2418700 f: +31 (0)30-2383749 nlinfo@phenomenex.com Mexico t: 01-800-844-5226 f: 001-310-328-7768 tecnicomx@phenomenex.com The Netherlands t: +31 (0)30-2418700 f: +31 (0)30-2383749 nlinfo@phenomenex.com New Zealand t: +64 (0)9-4780951 f: +64 (0)9-4780952 nzinfo@phenomenex.com Norway t: +47 810 02 005 f: +45 4810 6265 nordicinfo@phenomenex.com Portugal t: +351 221 450 488 f: +34 91-413-2290 ptinfo@phenomenex.com Spain t: +34 91-413-8613 f: +34 91-413-2290 espinfo@phenomenex.com Sweden t: +46 (0)8 611 6950 f: +45 4810 6265 nordicinfo@phenomenex.com Switzerland t: +41 61 692 20 20 f: +41 61 692 20 22 swissinfo@phenomenex.com United Kingdom t: +44 (0)1625-501367 f: +44 (0)1625-501796 ukinfo@phenomenex.com USA t: +1 (310) 212-0555 f: +1 (310) 328-7768 info@phenomenex.com All other countries Corporate Office USA t: +1 (310) 212-0555 f: +1 (310) 328-7768 info@phenomenex.com www.phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com BR59540318_I_1 Terms and Conditions Subject to Phenomenex Standard Terms & Conditions, which may be viewed at www.phenomenex.com/termsandconditions. Trademarks biozen, BioTi, SecurityGuard, Phenex, and Verex are trademarks of Phenomenex. SecurityGuard is patented by Phenomenex. U.S. Patent No. 6,162,362 CAUTION: this patent only applies to the analytical-sized guard cartridge holder, and does not apply to SemiPrep, PREP or ULTRA holders, or to any cartridges. FOR RESEARCH USE ONLY. Not for use in clinical diagnostic procedures. 2018 Phenomenex, Inc. All rights reserved.