Installation Instructions

Similar documents
C7400A and C7400C Enthalpy Sensors

C7400A and C7400C Enthalpy Sensors

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

Exercise 1: Thermistor Characteristics

Designing a Thermostat Worksheet

INSTRUCTION MANUAL ANALOG COLORIMETER

Exercise 2: The DC Ohmmeter

Installation and Operation Manual. AllSync Plus Wired Clocks

MULTI-OUTPUT PROGRAMMABLE CONTROLLERS MODELS UMX-4 & UMX-8

POINTS OF CAUTION BEFORE USE...

Assembly and Operation Manual. April 2016

What You Need to Get Started INSTALLATION GUIDE

PHOENIX CONTACT - 04/2016. Features

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

3mm Surface Mount, Single-Turn, Sealed Cermet Trimmers

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

Pressure Display Controller

REPAIR PARTS. GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS951155DXAB.

PARTS CATALOGUE / TECHNICAL GUIDE Cal. 4F32A, 8F32A Cal. 8F33A, 8F35A

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

TEC BACnet MS/TP Network Series Thermostat Controllers Technical Bulletin

Minute Impulse Clock Controller I01DN

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

REPAIR PARTS. AMH95 Amana brand 95% Hybrid Furnace AMH950453BXAA AMH950703BXAA AMH950704CXAA AMH950904CXAA AMH950905DXAA AMH951155DXAA

Project. Project Location. Catalog #

M2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

KZPb

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

KZMb

MKIII -MB USER S GUIDE 09/18/18. Rev. 3

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

16mm Size Metal Shaft Type

A Rain Sensitive House Window Closes Automatically When Raining

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

REPAIR PARTS. DSXC 16/18 SEER Remote Condensing Unit

Product Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Drive electronics pq12

TRANMITTER QUALITY VERIFYING. HygroDat 20 M TR 200 I-2002 HygroClip HMP 233. Humidity- and Temperature Measurement System for process control

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintages C, D. TYA, TAA Vintages A, B. Last Manufactured: 1999

Barometric Relief Damper

REPAIR PARTS. DSZC 16/18 SEER Remote Heat Pump

FOREMAN ASSEMBLY / OWNER S MANUAL

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

5SJ4...-.HG Circuit Breakers to IEC and UL 489

HVAC Electrical Wiring Diagrams / Ohm s Law / Sequence of Operation RV

PUSH TUBE STANDARD DUTY

Edgetech Instruments Inc.

SKF actuators available for quick delivery. Selection guide

INSTALLATION GUIDE OWNER S GUIDE

nufacturing Company, L.P San Felipe, Suite 500

Digital Controller Operation

Features of Uni-Thermo

I-FORCE Ironless linear motors

KSAb

FOR POLARIS ATV s P/N ASSEMBLY / OWNERS MANUAL

TB-2012M BAROMETRIC PRESSURE SENSOR USER S MANUAL

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

W7459A,B,C,D Solid State Economizer Logic Module

TEMPERATURE SENSOR. Model TH-T. Roctest Limited, All rights reserved.

Variable swirl diffusers

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012

5484BN/R7DC-AHJB/XR/MS(ELA)

Water terminal control solutions

ATV WP2 FRONT MOUNT PUSH TUBE

Technical Instructions 5020.B. Specification 12 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm

WIP201610P L Series Engineering Specification

Field Pro Operation and Installation Manual

REPAIR PARTS. GUP, GUPI, and GUPX "B" SERIES

Performance Measurements for Mechanical Air Handling Systems

WIP252012P L Series Engineering Specification

Route and retain the clinometer cable so that it does not interfere with moving parts where the unit is mounted.

SKA DDL IRON CORE LINEAR MOTORS. Direct Drive Technology

ME 4/549 Lab Assignment 5: Single Block Experiment Spring 2006 due 1 June 2006

LM35 Precision Centigrade Temperature Sensors

Technical Instructions cal D. Specifikation 12 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

Pyschrometric Sample Problem Pharmaceutical Engineering Graduate Program New Jersey Institute of Technology

REPAIR PARTS. DSZC 16/18 SEER Remote Heat Pump

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

SSi Super Systems Inc.

REPAIR PARTS. DSXC16/18 Remote Condensing Units. This manual is to be used by qualified technicians only. This manual replaces RP-580D.

REPAIR PARTS. MBE/MBR Air Handlers

variable flow dampers

SIMPLE D.C. CIRCUITS AND MEASUREMENTS Background

A.R.M. 52 PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER BLACK MODEL NUMBER GRAY. Owner s Manual

Circuit Analysis and Ohm s Law

TABLE OF CONTENTS. IC Recorder. Model No. RR-US300E. Colour (S)...Silver Type

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

Product Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow

LUSTROUS DREAM V3. High Power Solid-State LED Light Source. Introduction

Transcription:

PACKAGE CONTENTS ITEM QUANTITY Enthalpy Sensor (Part No. HH57AC078) No. 6B, 3 4-in. long Sheet Metal Screw 2 Blue Wire Assembly (256-in. long with 4-in. quick-connect fitting)* Violet Wire Assembly (256-in. long with 4-in. quick-connect fitting) 4-in. Quick-Connect Terminal Wire Tie 0 *The blue wire assembly is not used for enthalpy single-sensor installation into the TJ units. The quick-connect terminal is only used for enthalpy sensor installation into the TJ units. GENERAL There are 2 types of enthalpy control: single-sensor and differential. Both are accomplished using the enthalpy sensor part no. 50DJ90232. All units except the 48/50TJ06-028 units come with one outdoor-air enthalpy sensor as standard (on units with factory-installed economizers), and therefore have the single-sensor enthalpy control function as standard. For the 48/50TJ units, enthalpy control is not available as standard from the factory (on units with the factory-installed economizer), but an outdoor dry-bulb control is available. If single, outdoor-air enthalpy control is desired, a single enthalpy sensor must be installed in these units. NOTE: All accessory field-installed economizers have singlesensor enthalpy control as standard in the package (including TJ units). Differential enthalpy control is used to increase the operating efficiency of the rooftop system. The system compares the temperature and humidity of the return air to that of the outdoor air to determine whether outdoor air or mechanical cooling is more economical and efficient. On all units with a factory-installed economizer (except the 48/50TJ06-028), a single return-air enthalpy sensor is required to complement the factory-installed outdoor-air enthalpy controller to provide the differential enthalpy control function. The 48/ 50TJ06-028 units require 2 accessory enthalpy sensors to accomplish differential enthalpy control. NOTE: Differential enthalpy control can be accomplished with accessory enthalpy sensor on TJ units with accessory field-installed economizer. 48DJ,DK,LJ,NK,NP024-074 48/50TJ06-028 50DJ,DK,DW,DY,LJ,LW,NB,NK,NP,NY024-074 64RT028 Accessory Enthalpy Sensor Installation Instructions Part No. 50DJ90232. Remove and discard the factory-installed jumper assembly containing the 800-ohm resistor on the economizer control module (between terminals S R and +). See Fig.. 2. Remove black wire assembly containing the 620-ohm resistor from between economizer control module terminal S O and the outdoor-air thermostat (OAT). Place this wire assembly (containing the 620-ohm resistor) between economizer control module terminals S R and +, replacing the jumper removed in Step. See Fig.. 3. Disconnect the blue wire from the OAT. 4. Remove OAT from the outside of the economizer (see Fig. 2). 5. Mount the enthalpy sensor (Fig. 3) to the economizer on the outside of the unit (in the same location from which the OAT was removed) using the 2 screws provided. See Fig. 2. 6. Reconnect the blue wire removed in Step 3 to the enthalpy sensor terminal +. 7. Cut the violet wire provided to desired length and terminate with quick-connect terminal provided. Route the violet wire from the enthalpy sensor terminal S, through the snap bushing, and to the economizer control module terminal S O. See Fig.. SINGLE-SENSOR, OUTDOOR-AIR ENTHALPY CONTROL INSTALLATION 48/50TJ06-028 ONLY NOTE: The outdoor-air enthalpy sensor must be installed BEFORE the economizer hoods are installed on the unit or hoods will have to EC Enthalpy Control Sensor LED Light-Emitting Diode Fig. Economizer Control Module Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book PC Catalog No. 565-024 Printed in U.S.A. Form 50DJ-2SI Pg 7-93 Replaces: 48/50D,L,N-5SI Tab a b

8. Set changeover set point to the desired location. See Fig. 4. NOTE: For maximum benefit of outdoor air, set the enthalpy control to the A setting. At this setting, when the relative humidity is 50% and the outdoor air is below 74 F, the relay contacts on the sensor will be closed. 9. Reinstall economizer hoods if removed. CONTROL CONTROL POINT CURVE (Approx Deg) AT 50% RH A 73 B 68 C 63 D 58 ENTHALPY CONTROL RH Relative Humidity Fig. 4 Psychrometric Chart for Solid-State Enthalpy Control OAT Outdoor-Air Thermostat Fig. 2 Enthalpy Sensor Installed DIFFERENTIAL ENTHALPY CONTROL INSTALLATION ALL UNITS Fig. 3 Outdoor-Air and Return-Air Enthalpy Sensor + Size 06-028 Constant Volume Units (48/50TJ Units) NOTE: The outdoor-air enthalpy sensor must be installed BEFORE the economizer hoods are installed on the unit or hoods will have to. Remove and discard the factory-installed jumper assembly containing the 800-ohm resistor on the economizer control module (between terminals S R and +. See Fig.. 2. Disconnect black wire from economizer control module terminal S O and blue wire from the OAT (outdoor-air thermostat). 3. Remove OAT and black wire assembly containing the 620-ohm resistor from the outside of the economizer (see Fig. 2). 4. Mount the outdoor-air enthalpy sensor (first sensor) to the economizer on the outside of the unit (in the same location from which the OAT was removed) using the 2 screws provided. See Fig. 2. 5. Reconnect the blue wire removed in Step 2 to the enthalpy sensor terminal +. 6. Cut the violet wire provided to desired length and terminate with quick-connect terminal provided. Route the violet wire from the enthalpy sensor terminal S, through the snap bushing, and to the economizer control module terminal S O. 7. Mount the second enthalpy sensor in the return-air duct (return-air sensor). 8. Route the blue wire (provided) from terminal + on the return-air enthalpy sensor to the economizer control module terminal +. 2

9. Route the violet wire (provided) from terminal S on the return-air enthalpy sensor to the economizer control module terminal S R. 0. Turn changeover set point dial clockwise past the D setting, or the control will not operate on a differential. See Fig... Reinstall economizer hood if removed. Size 024-030 Constant Volume Units (48DJ,LJ/50DJ,DW,LJ,LW and 64RT) NOTE: Return-air sensor must be installed before economizer. Remove access cover from top of economizer motor. See Fig. 5 and 6. + and S R on inside top of economizer motor access cover. See Fig. 7. 3. Route blue and violet wires supplied with differential enthalpy control sensor accessory through connector on the side of the economizer motor into the economizer motor wiring compartment. See Fig. 6. Connect the violet wire to + terminal and the blue wire to S R terminal. 4. Remove return-air enthalpy sensor from accessory package. bracket on filter track. See Fig. 5. 5. Connect violet wire to + terminal and blue wire to S terminal on return-air enthalpy sensor. Dress wires with wire ties supplied with accessory. 6. Replace economizer motor access cover. Turn the enthalpy set point potentiometer located on top of economizer motor clockwise past the D setting, or control will not operate on a differential. 7. Replace economizer hoods if removed. Size 024-030 Variable-Air Volume Units (48DJ,NK/50DJ,DK,NK,NY, 48NP/50NB,NP, and 64RT Units) NOTE: Return-air sensor must be installed before the economizer. Remove economizer hood (if hoods are already installed) to gain access to enthalpy control and outdoor-air section of unit. See Fig. 8 and 9. S R and + on enthalpy control in unit. See Fig. 7. 3. Connect violet wire to + terminal and blue wire to S R terminal on enthalpy control. (Wires are supplied with the differential enthalpy accessory.) 4. Turn the enthalpy control set point potentiometer clockwise past the D setting on the enthalpy control, or control will not operate on a differential. 5. Route wires to filter section as shown in Fig. 5, using wire ties to attach to existing wires. 6. Remove return-air enthalpy sensor from accessory package. bracket on filter track. See Fig. 5. 7. Connect violet wire to + terminal and blue wire to S terminal on return-air enthalpy sensor. 8. Reinstall economizer hood on side of unit. Fig. 5 Return-Air Enthalpy Sensor Installation and Wire Routing, 024-030 Units 3

OUTDOOR TEMP. F 55 S OPEN 3 T 5 2 4 T B C D TR P P DAMPER OPEN DAMPER CLOSED D C B A OR UNPOWERED STATE CW SETPOINTS CCW 3 2 24VAC Fig. 6 Economizer Motor Fig. 8 Economizer Hood Removal ENTHALPY CONTROL MINIMUM POSITION SO REV. B 9888A 90 70 60 30 0 % H U M I D I T Y 50 60 65 70 75 RUSH AT 24VAC 3 ma MIN. AT VDC CONTACT RATINGS:.5A RUN, 3.5A IN CONTACTS SHOWN IN HIGH ENTHALPY TR TR ENTHALPY CONTROL 620-OHM JUMPER 80 85 REV. 97-3672 NOTE: Sensor is on the back of the enthalpy control and is hidden in this photo. Fig. 7 Factory-Installed Enthalpy Control and Sensor Fig.9 Typical Enthalpy Control and Sensor Location 4

Size 034-074 Constant Volume Units Manufactured After 2//92 (48DJ/50DJ,DW Units) NOTE: Return-air sensor must be installed before economizer. Remove access cover from top of economizer motor. See Fig. 6 and 0. + and S R on inside top of economizer motor access cover. 3. Route blue and violet wire supplied with differential enthalpy control accessory through connector on the side of the economizer motor into the economizer motor wiring compartment. See Fig. 6. Connect the violet wire to + terminal and the blue wire to S R terminal. 4. Remove return-air enthalpy sensor from accessory package. bracket on filter track. See Fig. 0. 5. Connect violet wire to + terminal and blue wire to S terminal on return-air enthalpy sensor. Dress wires with wire ties supplied with accessory. 6. Replace economizer motor access cover. Turn the enthalpy set point potentiometer located on top of economizer motor clockwise past the D setting, or control will not operate on a differential. 7. Reinstall hoods if removed. Size 034-074 Variable-Air Volume Units Manufactured After 2//92 (48DK,NK/ 50DK,DY,NK,NY, 48NP/50NB,NP Units) NOTE: Return-air sensor must be installed before the economizer. Remove economizer hood (if hoods are already installed) from one side of unit to gain access to enthalpy control and outdoor-air section of unit. See Fig. 0. S R and + on enthalpy control in unit. See Fig. 7. 3. Connect violet wire to + terminal and blue wire to S R terminal on enthalpy control. (Wires are supplied with the enthalpy sensor accessory.) 4. Turn the enthalpy set point potentiometer clockwise past the D setting on the enthalpy control, or control will not operate on a differential. 5. Route wires to filter section as shown in Fig. 0, using wire ties to attach to existing wires. 6. Remove return-air enthalpy sensor from accessory package. bracket on filter track. See Fig. 3 and 0. 7. Connect violet wire to + terminal and blue wire to S terminal on return-air enthalpy sensor. 8. Reinstall economizer hood on side of unit. Fig. 0 Differential Enthalpy Control Wiring Detail 5

All Size 034-074 Units Manufactured Prior to 2//92 (48DJ,DK,NK/50DJ,DK,DW,DY,NK, NY Units) NOTE: Return-air sensor must be installed before the economizer. Remove economizer hood (if hoods are already installed) from one side of unit to gain access to enthalpy control and outdoor-air section of unit. See Fig. 0. S R and + on enthalpy control in unit. See Fig. 7. 3. Connect violet wire to + terminal and blue wire to S R terminal on enthalpy control. (Wires are supplied with the differential enthalpy accessory.) 4. Turn the enthalpy set point potentiometer clockwise past the D setting on the enthalpy control, or control will not operate on a differential. 5. Route wires as shown in Fig. 0, using wire ties to attach to existing wires. 6. Remove return-air enthalpy sensor from accessory package. bracket on filter track. See Fig. 3 and 0. 7. Connect violet wire to + terminal and blue wire to S terminal on return-air enthalpy sensor. 8. Reinstall economizer hood on side of unit. ENTHALPY SENSOR CHECKOUT After installing the sensor(s), check them out to ensure proper installation and working condition. Refer to appropriate base unit Installation Instructions for complete troubleshooting information on the economizer controls. Outdoor-Air Sensor TEST The enthalpy sensor terminal + should be connected to terminal + on the economizer control module. Connect the positive ( +) terminal of a DC milliammeter to the S terminal of the sensor and the negative ( ) terminal of the meter to terminal S O of the economizer control module. RESULTS The milliammeter reading should be between 3 and 24 ma if the sensor is operating correctly. If the reading is 0 ma, the sensor is either wired backwards or is defective. Return-Air Sensor TEST The enthalpy sensor terminal + should be connected to terminal + on the economizer control module. Connect the positive (+) terminal of a DC milliammeter to the S terminal of the sensor and the negative ( ) terminal of the meter to terminal S R of the economizer control module. RESULTS The milliammeter reading should be between 3 and 24 ma if the sensor is operating correctly. If the reading is 0 ma, the sensor is either wired backwards or is defective. Economizer Checkout Procedures (48/50TJ Units Only) TEST PROCEDURE A. Disconnect power at TR and TR. Disconnect jumper between P and P. See Fig.. B. Jumper TR to. C. Jumper T to T. D. Disconnect outdoor-air thermostat connections from S O and +. Factory-installed 800 ohm resistor should remain connected to S R and +. E. Reconnect power to terminals TR and TR. TEST PROCEDURE A. Disconnect factory-installed resistor from terminals S R and +. RESULTS. LED (light-emitting diode) should be off. 2. Motor is in closed position. RESULTS. LED (light-emitting diode) should be on. 2. Motor drives toward open. High and Low Enthalpy Simulation TEST PROCEDURE A. Reconnect factoryinstalled 800 ohm resistor between terminals S R and +. B. Connect 200 ohm checkout resistor between terminals S O and +. C. Turn set point potentiometer to position A. D. Turn set point potentiometer to position D. E. Disconnect 200 ohm checkout resistor. RESULTS Low enthalpy test results:. LED (light-emitting diode) should be on. 2. Motor drives toward open. High enthalpy test results:. LED should be off. 2. Motor drives toward closed. 6

Copyright 993 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book PC Catalog No. 565-024 Printed in U.S.A. Form 50DJ-2SI Pg 8 7-93 Replaces: 48/50D,L,N-5SI Tab a b