Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

Similar documents
Chemistry 524--Final Exam--Keiderling Dec. 12, pm SES

Chem 524 Lecture Notes CD (Section 18) update 2011

Spectroscopy Problem Set February 22, 2018

CHEM*3440. Photon Energy Units. Spectrum of Electromagnetic Radiation. Chemical Instrumentation. Spectroscopic Experimental Concept.

CHEM Outline (Part 15) - Luminescence 2013

Instrumental Analysis: Spectrophotometric Methods

Chem Homework Set Answers

Ch 313 FINAL EXAM OUTLINE Spring 2010

Chapter 15 Molecular Luminescence Spectrometry

Complete the following. Clearly mark your answers. YOU MUST SHOW YOUR WORK TO RECEIVE CREDIT.

Model Answer (Paper code: AR-7112) M. Sc. (Physics) IV Semester Paper I: Laser Physics and Spectroscopy

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

Classification of spectroscopic methods

Advanced Spectroscopy Laboratory

Chapter 6 Photoluminescence Spectroscopy

Lecture 0. NC State University

CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016

INTRODUCTION Atomic fluorescence spectroscopy ( AFS ) depends on the measurement of the emission ( fluorescence ) emitted from gasphase analyte atoms

high temp ( K) Chapter 20: Atomic Spectroscopy

AS 101: Day Lab #2 Summer Spectroscopy

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

Chemistry 543--Final Exam--Keiderling May 5, pm SES

Molecular Luminescence Spectroscopy

DEPARTMENT OF CHEMISTRY UNIVERSITY OF SWAZILAND

1. Transition dipole moment

Atomization. In Flame Emission

Application of IR Raman Spectroscopy

Analytical Spectroscopy Review

Atomic Emission Spectroscopy

Spectroscopy tools for PAT applications in the Pharmaceutical Industry

LABORATORY OF ELEMENTARY BIOPHYSICS

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Spectroscopy. Page 1 of 8 L.Pillay (2012)

Fourier Transform Infrared. Spectrometry

IR Spectrography - Absorption. Raman Spectrography - Scattering. n 0 n M - Raman n 0 - Rayleigh

Ultraviolet-Visible and Infrared Spectrophotometry

2001 Spectrometers. Instrument Machinery. Movies from this presentation can be access at

DAY LABORATORY EXERCISE: SPECTROSCOPY

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

Chem 524 Lecture Notes Raman (Section 17) 2013

Chem 155 Midterm Exam Page 1 of 10 Spring 2010 Terrill

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

Comments to Atkins: Physical chemistry, 7th edition.

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

Raman and stimulated Raman spectroscopy of chlorinated hydrocarbons

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

JABLONSKI DIAGRAM 2/15/16

25 Instruments for Optical Spectrometry

Absorption photometry

Spectroscopy: Introduction. Required reading Chapter 18 (pages ) Chapter 20 (pages )

9/13/10. Each spectral line is characteristic of an individual energy transition

EXPERIMENT 09 OBSERVATION OF SPECTRA

Lecture 16 Instrumentation for ICP AES-VIII-Instruments

Diagnósticos em Plasmas

Wavelength λ Velocity v. Electric Field Strength Amplitude A. Time t or Distance x time for 1 λ to pass fixed point. # of λ passing per s ν= 1 p

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

Chemistry 2. Molecular Photophysics

9/28/10. Visible and Ultraviolet Molecular Spectroscopy - (S-H-C Chapters 13-14) Valence Electronic Structure. n σ* transitions

DETERMINATION OF RELATIVE FLUORESCENCE QUANTUM YIELD USING THE AGILENT CARY ECLIPSE

Atomic Absorption Spectroscopy

Singlet. Fluorescence Spectroscopy * LUMO

OPERATING INSTRUCTIONS

How does your eye form an Refraction

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

a. An emission line as close as possible to the analyte resonance line

Answers to questions on exam in laser-based combustion diagnostics on March 10, 2006

P. Lambrev October 10, 2018

Astr 2310 Thurs. March 3, 2016 Today s Topics

Atomic Absorption Spectroscopy (AAS)

n ( λ ) is observed. Further, the bandgap of the ZnTe semiconductor is

Skoog Chapter 6 Introduction to Spectrometric Methods

Physics 214. Midterm Exam Spring Last Name: First Name NetID Discussion Section: Discussion TA Name:

Analytical Chemistry II

Explain With A Schematic Diagram The Principle Of Vapor Absorption System

CHM 424 EXAM 4 CRIB - COVER PAGE FALL

1901 Application of Spectrophotometry

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

How does your eye form an Refraction

Lecture 7: Atomic Spectroscopy

Direct, Reliable, and Correct Oxygen Measurement

Fluorescence Polarization Anisotropy FPA

Spectroscopy. Practical Handbook of. J. W. Robinson, Ph.D., D.Sc, F.R.C.S. Department of Chemistry Louisiana State University Baton Rouge, Louisiana

Atomic Absorption & Atomic Fluorescence Spectrometry

What is spectroscopy?

2101 Atomic Spectroscopy

Preview from Notesale.co.uk Page 1 of 38

Supplementary Information for. Vibrational Spectroscopy at Electrolyte Electrode Interfaces with Graphene Gratings

CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016

Physics 214 Midterm Exam Spring Last Name: First Name NetID Discussion Section: Discussion TA Name:

JABLONSKI DIAGRAM INTERACTIONS BETWEEN LIGHT AND MATTER LIGHT AS A WAVE LIGHT AS A PARTICLE 2/1/16. Photoelectric effect Absorp<on Emission ScaDering

Introduction. Molecules, Light and Natural Dyes. Experiment

Phys 2310 Fri. Dec. 12, 2014 Today s Topics. Begin Chapter 13: Lasers Reading for Next Time

Chem 310 rd. 3 Homework Set Answers

Chem 344 Final Exam Tuesday, Dec. 11, 2007, 3-?? PM

EMISSION SPECTROSCOPY

What happens when light falls on a material? Transmission Reflection Absorption Luminescence. Elastic Scattering Inelastic Scattering

Spectroscopy in Inorganic Chemistry. Vibration and Rotation Spectroscopy

Electronic Excitation by UV/Vis Spectroscopy :

Measurement Examples. Excitation and Emission Scans. Steady State Fluorescence Anisotropy. Kinetic Measurements

R O Y G B V. Spin States. Outer Shell Electrons. Molecular Rotations. Inner Shell Electrons. Molecular Vibrations. Nuclear Transitions

Transcription:

Chemistry 524--Final Exam--Keiderling May 4, 2011 3:30 -?? pm -- 4286 SES Please answer all questions in the answer book provided. Calculators, rulers, pens and pencils are permitted. No open books or extra sheets allowed. If you need a specific fundamental constant, conversion factor or definition ask for it; but everything needed should be in the exam, unless I made an error! Strategy there are lots of small questions, if you do not know one, skip ahead, leave a space in your answer book, it may come to you later and you will not waste time. You do not need to answer everything to get a good grade. There is some possibly helpful information at the end of the exam. GOOD LUCK! In the second half of the course we surveyed a number of different optical spectroscopic techniques and for each we reviewed the technologies used for building the spectrometers used for different kinds of analytical applications. Questions 1 7 are organized like the end of the course. All answers should be short and to the point, best answers are a few sentences. Unless clearly indicated to choose between them, all parts should be answered: 1. [10] Atomic spectroscopy is very valuable but got a short attention in lecture, although a large component of the text. It comes in several flavors: Atomic Absorption (AA), atomic emission (AE), resonance fluorescence, and I am sure there are several others. a. Compare AA and AE in terms of types of instrumentation needed, ability to discriminate analytes, costs, and sensitivity Answer only two (2) of b, c, d or e: b. What advantages does a graphite furnace have over flame atomization, problems? c. Describe the major steps the sample goes through for flame or plasma atomization. d. What are the advantages of using inductively coupled plasma (ICP) atomization? e. How is AA data quantified for determination of concentration? 2. [6] Molecular spectra are in general broader than atomic spectra and, if they were resolved to individual transitions, would be much more complex Answer only two (2) of a, b, c or d: a. Explain the apparent mirror symmetry between absorbance and fluorescence bandshapes and note why it is not a true mirror image b. Explain why fluorescence is normally seen from the S 1 excited state and often from just its v=0 vibrational state. How does this impact analyses? c. From which state do vibrations appear in the absorption spectral band shape, why? d. Why are rotational components of the molecular spectra relatively unimportant in analytical spectroscopy? - 1 -

3. [22] Absorbance spectroscopy in the uv-vis region underlies the most commonly used analytical techniques a. Absorbance requires two intensity measurements as opposed to one for luminescence. Explain why you need two, what they give you and how they are obtained Answer only one (1) of b or c: b. Explain a common way to create a double beam spectrometer (i.e. what kind of optical design is used) c. Explain some advantages of double beam spectrometry, disadvantages? Answer only two (2) of d, e, f or g: d. Some spectrometers scan from vis to uv but stop for a short time at ~350 nm. Explain why e. Since many spectrometers use gratings to scan from 200-800 nm, how do they avoid second and third order diffraction interference? Give one or two example solutions f. Some spectrometers vary the slit width as the scan proceeds. Give a plausible reason why g. What range of absorbance is reasonable for a commercial uv-vis? What are the limiting noise sources at high and low absorbances? Answer only one (1) of h or j: h. What is important about isobestic points for analyses? How can it be used analytically? i. Why use the wavelength corresponding to the band maximum for analyses if the whole band absorbance varies linearly with concentration? j. What impact can the slit width have on concentration determination with absorbance? Answer only one (1) of k or l: k. Xe arcs make very good uv-vis sources. Why are they not used in most commercial spectrometers? l. Why do you think are there not commercial CCD based uv-vis absorption spectrometers, but there are incredible numbers of digital cameras and telephones with CCDs? 4. [22] Molecular luminescence is the counterpart to absorbance and consists of fluorescence and phosphorescence (and other less analytically relevant methods) a. Many molecules do not fluoresce, even though they have absorbance. Explain why b. What kind of information is obtained by scanning the excitation wavelength and fixing the emission wavelength? How is it different from absorbance? c. Propose advantages and disadvantages of using a broad band (thermal) detector for normalization of the total source intensity as compared to excitation of a rhodamine dye with the output of the excitation monochromator and detection of its fluorescence. d. Describe how you would detect fluorescence lifetimes (there are two ways, pick one). Specify the types of detectors and electronics you would need e. Why can fluorescence for an isotropic sample be polarized but not absorbance? - 2 -

Answer only one (1) of f or g: f. Explain how you might discriminate phosphorescence from fluorescence in a sample g. How would you discriminate Raman from fluorescence in a sample Answer only one (1) of h or i: h. Explain sampling or experimental design changes that can enhance phosphorescence. i. What is quenching and give an example of using it for analysis of structure or properties? 5. [30] IR absorbance spectra are primarily used to monitor molecular vibrations a. Modern FTIRs dominate the market, partly due to the three advantages of FTIR. List the advantages and explain why each leads to more reliable spectra with FTIR as compared to dispersive IR b. For near-ir spectra the bands are usually broad and not uniquely assigned. Plus they are very weak. Explain why near-ir has none-the-less become a useful analytical tool and how it can gain discrimination (selectivity). c. Why is IR used more for qualitative analyses than for quantitative analyses? d. My lab uses a dispersive IR for measuring VCD of single broad bands in proteins. Propose another experiment where dispersive IR is (or could be) used. Answer only one (1) of e or f: e. Water and CO 2 in the atmosphere pose interference issues in the IR spectrum. How is this interference normally corrected in FTIR? Where are these bands spectrally? f. To correct for the solvent absorbance I can subtract the spectrum measure in a similar cell. Why might this be in error? Why might I still have an error if I use the same cell? Answer only one (1) of g or i: g. Explain why most FTIRs are used (default scan) from 400-4000 cm -1, what limits scan? h. What modifications are needed to extend to the Far IR region (e.g. 400-100 cm -1 )? i. If I want to modify my FTIR to a new region, which might be more difficult, far IR or near IR and explain why (many possible answers) Answer only one (1) of j or k: j. Old dispersive spectrometers used thermopile detectors but FTIRs use DTGS detectors, why is this? How do they differ in fundamental detection mechanism? k. Photon detectors for the IR, like MCT and InSb are normally cooled with liquid N 2. What is gained and what is lost in this cooling? Why do routine FTIRs (e.g. Mattson in 4315 SES) not have a cooled detector? Answer only one (1) of l or m: l. Explain why ATR is surface sensitive and transmission IR is bulk sensitive m. Describe some materials that are useful for sampling (making cells) water-based solutions of proteins, and explain why they are chosen. - 3 -

6. [16] Raman spectroscopy also is focused primarily on vibrational spectra. a. IR and Raman are viewed as complementary but both allow v = ±1 transitions, what makes them different (i.e. complementary)? b. Explain the difference between Stokes and anti-stokes Raman spectra, where you find these transitions and why Stokes is usually more intense. c. Raman and fluorescence spectrometers are conceptually alike, however Raman spectrometers almost always use a laser source for excitation and fluorimeters often use a broadband source with monochromator. Explain d. Raman spectrometers originally used double monochromators, why? Now they often use single spectrographs. Why did they change and how did they solve the problem? Answer only one (1) of e or f: e. How can you use an internal standard to get Raman cross-section (intensity) measurements from a single measurement? f. Why can Raman sample smaller volumes than IR, but often need more sample? 7. [13] Circular dichroism is measured as an absorption modulation spectroscopy. a. CD is actually measured as A in absorbance. Biochemists in particular are interested in CD expressed as [ ]. How is the conversion made? b. Most CDs use a photoelastic modulator (PEM, often from Hinds Inc.). Explain how it works for CD measurements c. Why is CD so useful in biochemical analysis studies? Answer only one (1) of d or e: d. JASCO CDs are popular, but use old fashioned prism monochromators and do not seem to have an obvious linear polarizer. Please explain these observations. e. OLIS has a different CD detection design. Explain some aspects of its differences Answer only one (1) of f or g: f. What criteria are needed for a CD to be used for kinetics with stop-flow mixing? g. CD in the IR is vibrational CD (VCD). Describe how a typical VCD instrument differs from a UV CD instrument? 8. [6] Answer only two (2) of the following, a. My MCT detector for my FTIR spectrometer has 1/f noise. How do I know this is the source and how can I adjust the experimental conditions so that this is unimportant? b. Once 1/f noise is reduced, the detector is limited by Johnson noise. What is the source of this noise and what can I do about it? c. If it were perfect, the detector would be shot noise limited. What is the source of this noise and how can it be reduced or how can the S/N be improved? - 4 -

9. [6] I have a fluorescence lifetime experiment which has a pulsed laser excitation, with pulses at 10 Hz. However the fluorescence decay data after each pulse are noisy. Describe/ design a detection scheme that I could use to improve the S/N and determine the lifetime if the pulse were 10 ns and the lifetime were 300 ns. Be specific about detectors and electronics and explain your choices. 10. [5] We described several filters and amplifiers based on op amps. Describe the characteristics of the input and outputs of a typical op amp and how it can be used to control gain or band pass. 11. [10] For the two reflection IR sampling accessories below, identify the main components, explain what kind of measurement they are used for and contrast the elements and flexibility (adjustments) needed in the design. Specify what kind of information they yield 12. [43] For the attached instrument diagrams (starting next page) choose either A or B and then do C and D and E (next two pages). Identify the possible function and type of each of the major parts that are hand-labeled with a number in a circle. You may make a table with numbers coding the objects in the diagram and for each identified item propose specifically which type of component (e.g. "source: quartz-halogen or W-I lamp" or "detector: PMT") is being used (note: for optical components, just put what it is and purpose, e.g. lens, focus beam on slit). For the source and detector, briefly justify the choice. Finally state the purpose of the instrument shown and why you think you are right. - 5 -

A B - 6 -

C D - 7 -

E - 8 -