Thermo-Hydraulic performance of Internal finned tube Automobile Radiator

Similar documents
Experimental Investigation of Natural Convection Heat Transfer in Heated Vertical Tubes

CFD Analysis on Flow Through Plate Fin Heat Exchangers with Perforations

Numerical analysis of fluid flow and heat transfer in 2D sinusoidal wavy channel

Effect of V-Shape Twisted Jaw Turbulators on Thermal Performance of Tube heat exchanger: An Experimental Study

Investigation of Jet Impingement on Flat Plate Using Triangular and Trapezoid Vortex Generators

The Effect of Solid and Perforated Pin Fin on the Heat Transfer Performance of Finned Tube Heat Exchanger

"Experimental investigation of heat transfer enhancement by u-shaped Turbulator"

EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT

Experimental investigation of heat transfer augmentation in triangular duct with rectangular wing

Ali S. Sharbuddin, International Journal of Advance Research, Ideas and Innovations in Technology.

Experimental Validation of Heat Transfer Enhancement in plate Heat Exchanger with Non Conventional Shapes of Rib

EXPERIMENTAL STUDY OF DEVELOPING TURBULENT FLOW AND HEAT TRANSFER IN RIBBED CONVERGENT/DIVERGENT RECTANGULAR DUCTS

Estimation of Heat Transfer in Internally Micro Finned Tube

Investigation of Heat Transfer Enhancement in Laminar Flow through Circular Tube Combined Wire Coil and Wavy Strip with Central Clearance

Experimental Investigation of Forced Convection Heat Transfer Augmentation from a Dimpled Surface

Experimental Analysis of Rectangular Fin Arrays with Continuous Fin and Interrupted Fins Using Natural and Forced Convection

PERFORMANCE ANALYSIS OF PARABOLIC TROUGH COLLECTOR TUBE WITH INTERNAL INTERMITTENT FINS

Experimental and Numerical Investigation of a Multi Louvered Plate Fin-and-Tube Heat Exchanger using Computational Fluid Dynamics

International Conference on Energy Efficient Technologies For Automobiles (EETA 15) Journal of Chemical and Pharmaceutical Sciences ISSN:

Comparative Analysis of Heat Transfer and Friction Characteristics in a Corrugated Tube

CFD study for cross flow heat exchanger with integral finned tube

Experimental Analysis of Heat Transfer Enhancement over Dimpled Surface on One Side of Plate

CFD Analysis of Forced Convection Flow and Heat Transfer in Semi-Circular Cross-Sectioned Micro-Channel

Keywords: air-cooled condensers, heat transfer enhancement, oval tubes, vortex generators

Experimental Investigation of Heat Transfer Enhancement by Using Clockwise and Counter -clockwise Corrugated Twisted Tape Inserts

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

Numerical Investigation of Multijet Air Impingement on Pin Fin Heat Sink with Effusion Slots

W-Discrete Rib for Enhancing the Thermal Performance of Solar Air Heater

Enhancement of Heat Transfer Effectiveness of Plate-pin fin heat sinks With Central hole and Staggered positioning of Pin fins

Experimental and Numerical Analysis of Turbulent Flow Heat Transfer Enhancement in a Horizontal Circular Tube Using Mesh Inserts

3D NUMERICAL STUDY OF LOCAL HEAT TRANSFER COEFFICIENT OF WAVY PLATE FIN WITH CIRCULAR TUBE HEAT EXCHANGERS USING CFD

Numerical Simulation Of Fluid Flow And Heat Transfer Of Supercritical Pressure

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

Effective Heat Transfer Enhancement in Finned Tube Heat Exchanger with Different Fin Profiles

Heat Augmentation Using Non-metallic Flow Divider Type Inserts in Forced Convection

Investigation of Effects on Heat Transfer and Flow Characteristics of Cr-Ni Alloy and Aluminum Pins Placed in AISI 304 Tube

International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May ISSN

Performance analysis of V-jagged twisted tape insert for heat transfer in a circular tube

Numerical Investigation on Air Side Performance of Fin and Tube Heat Exchnagers with Different Types of Fins

Enhancement of Heat Transfer in Heat Exchanger using Punched and V-cut Twisted Tape Inserts

Experimental and Theoretical Investigation of Hydrodynamics Characteristics and Heat Transfer for Newtonian and Non-newtonian Fluids

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online):

INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 5, ISSUE 09, SEPTEMBER 2016 ISSN

CHAPTER 7 NUMERICAL MODELLING OF A SPIRAL HEAT EXCHANGER USING CFD TECHNIQUE

Heat Transfer Enhancement of Solar Air Heater By Using Artificial Roughness double inclined ribs

International Journal of Engineering, Business and Enterprise Applications (IJEBEA)

Free and Forced Convection Heat Transfer Characteristics in an Opened Box with Parallel Heated Plates

Numerical Analysis of Fe 3 O 4 Nanofluid Flow in a Double Pipe U-Bend Heat Exchanger

Numerical Investigation on The Convective Heat Transfer Enhancement in Coiled Tubes

Numerical Investigation of Convective Heat Transfer in Pin Fin Type Heat Sink used for Led Application by using CFD

Research Article. Kaustubh G. Kulkarni * and Mandar M. Lele. Abstract

Comparative study of Different Geometry of Ribs for roughness on absorber plate of Solar Air Heater -A Review

Analysis of the Cooling Design in Electrical Transformer

CFD Analysis & Experimental Investigation to improve Heat Transfer Enhancement in flat plate with W Ribs

EXPERIMENTAL AND CFD ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN TUBULAR EXCHANGER

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

Experimental Study of Convective Heat Transfer and Thermal Performance in the Heat-Sink Channel with Various Geometrical Configurations Fins

EXPERIMENTAL AND CFD ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN TUBULAR HEAT EXCHANGER

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF A V-RIB WITH GAP ROUGHENED SOLAR AIR HEATER

CFD Analysis for Thermal Behavior of Turbulent Channel Flow of Different Geometry of Bottom Plate

COMPUTATIONAL FLUID DYNAMIC ANALYSIS ON THE EFFECT OF PARTICLES DENSITY AND BODY DIAMETER IN A TANGENTIAL INLET CYCLONE HEAT EXCHANGER

Experimental Analysis on Pin Fin Heat Exchanger Using Different Shapes of the Same Material

Heat Transfer Simulation by CFD from Fins of an Air Cooled Motorcycle Engine under Varying Climatic Conditions

ENERGY PERFORMANCE IMPROVEMENT, FLOW BEHAVIOR AND HEAT TRANSFER INVESTIGATION IN A CIRCULAR TUBE WITH V-DOWNSTREAM DISCRETE BAFFLES

JJMIE Jordan Journal of Mechanical and Industrial Engineering

Heat Transfer Enhancement Through Perforated Fin

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

THE INFLUENCE OF INCLINATION ANGLE ON NATURAL CONVECTION IN A RECTANGULAR ENCLOSURE

A study of Heat Transfer Enhancement on a Tilted Rectangular Stainless Steel Plate

Forced Convection Heat Transfer Augmentation from Ribbed Surface

Thermo-Hydraulic Performance of a Roughened Square Duct Having Inclined Ribs with a Gap on Two Opposite Walls

Lecture 30 Review of Fluid Flow and Heat Transfer

Visualization of flow pattern over or around immersed objects in open channel flow.

International Journal of Research in Advent Technology, Vol.6, No.11, November 2018 E-ISSN: Available online at

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: ,

Applied Thermal Engineering

CFD STUDIES IN THE PREDICTION OF THERMAL STRIPING IN AN LMFBR

CFD Analysis of High Temperature and High Velocity System: Plasma Torch

Flow and Heat Transfer Profiles in a Square Channel with 45 V-Downstream Orifices

Experimental Heat transfer study of Turbulent Square duct flow through V type turbulators

HEAT TRANSFER AND FLOW CHARACTERISTICS OF OFFSET FIN AND FLAT TUBE HEAT EXCHANGERS UNDER LOW PRESSURE ENVIRONMENT

SSRG International Journal of Mechanical Engineering ( SSRG IJME ) Volume 2 Issue 5 May 2015

Heat Transfer Enhancement with Different Square Jagged Twisted Tapes and CuO Nano fluid

Experimental Investigation of Internal Channel Cooling Via Jet Impingement

THE EFFECT OF VORTEX GENERATORS ON PRESSURE AND SKIN FRICTION IN A DIFFUSER

Heat Transfer Enhancement Using a Rotating Twisted Tape Insert

HEAT TRANSFER ENHANCEMENT WITH ELLIPTICAL TUBE UNDER TURBULENT FLOW TiO 2 -WATER NANOFLUID

Chapter 5 MATHEMATICAL MODELING OF THE EVACATED SOLAR COLLECTOR. 5.1 Thermal Model of Solar Collector System

SIMULATION OF FLOW STRUCTURE AND HEAT TRANSFER ENHANCEMENT IN A TRIANGULAR DUCT WITH RECTANGULAR WING

LAMINAR NATURAL CONVECTION HEAT TRANSFER FROM AN ISOTHERMAL VERTICAL RIBBED PLATE

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

STUDY OF FLOW & HEAT TRANSFER IN PLATE FIN HEAT EXCHANGER AT VARYING REYNOLD S NO

Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters

A Computational Fluid Dynamics Investigation of Solar Air Heater Duct Provided with Inclined Circular Ribs as Artificial Roughness

Experimental Investigations on the Local Distribution of wall static pressure coefficient Due To an Impinging Slot Air Jet on a Confined Rough Surface

NUMERICAL ANALYSIS OF HEAT TRANSFER INCREASE IN A TUBE WITH ALTERNATE SUCCESSIVE GRADUAL WALL DEFORMATIONS

International Journal of Engineering Research and General Science Volume 3, Issue 6, November-December, 2015 ISSN

Performance of Elliptical Pin Fin Heat Exchanger with Three Elliptical Perforations

Experimental Investigation of Trapezoidal Duct using Delta Wing Vortex Generators

CFD Analysis of Multi-jet Air Impingement on Flat Plate

Transcription:

Thermo-Hydraulic performance of Internal finned tube Automobile Radiator Dr.Kailash Mohapatra 1, Deepiarani Swain 2 1 Department of Mechanical Engineering, Raajdhani Engineering College, Bhubaneswar, 751017, India 2 Department of Mechanical Engineering, Raajdhani Engineering College, Bhubaneswar, 751017, India ABSTRACT Thermo-fluid behaviour of finned and finless tube was investigated experimentally and numerically using Fluent 14. One meter length aluminium tube of diameter 0.044 m subjected to constant heat flux on the outer surface was chosen both for numerical and experimental purpose. High velocity of air supplied by the blower and orifice meter was used to measure the flow rate. The thermocouples are used for measuring the inlet, outlet and wall temperatures. Finned tube consisting of longitudinal rectangular sectioned fins attached on the inner periphery of the tube. The numerical simulations were performed by solving 3-D conservation equations of mass, momentum and energy with two equation based -ε turbulent model. It was found from the investigations that for the same heat flux and Reynolds number, the wall temperature was lowest, Nusselt number was 2.5 times for 8 numbers of internal fins finned tube compared to plain tube and convective resistance was minimum for 8 numbers of internal finned tubes. Key words: CFD, Nusselt number, friction factor, heat transfer coefficiente, wall temperature, thermocouples Nomenclature Subscripts D diameter of tube (m) avg average f friction factor B bul H height of the fin (m) O outlet h heat transfer coefficient (W/m 2 C) x local L length of the tube (m) sx axial distance along the wall n number of tube q heat flux Re Reynolds number T temperature (K) W width of the fin (m) x axial distance (m) 1. INTRODUCTION The radiators are generally used in automobiles for the purpose to transfer the heat of the coolant which is circulated around the internal combustion engines to the atmosphere so that the temperature of the engine is always ept below safe operating temperature. The radiators are specially placed in front of the vehicles and in turn increase the frontal area and during the movement of the vehicle it produces maximum drag force. To overcome this drag force more engine power will be required and that will increase the fuel consumption and decrease the engine efficiency. So we can tell that the engine efficiency depends on the size of the radiators. By reducing the size of the radiator the engine efficiency increases and vice versa. The size of the radiator can be reduced by using different type s methods and heat transfer augmentation technique is one of them without sacrificing the efficiency. Attaching the fins on either side of the flow passage is one of the heat transfer augmentation technique and different researchers wored on this are described below. Recently experimental study performed by different researchers shows that friction factor and Nusselt number is higher for rectangular and triangular fins compared to round crest fins [1]. Moore and Joshi [2] concluded from experimental investigation by introducing a small amount of tip clearance in pin fin increases the heat transfer and reduces the pressure drop. Moon and Lau [3] conducted experimental study on rectangular channel to study the steady heat transfer between the two blocages having holes in the turbulent for nine different staggered arrays of holes in the blocages. They found that the blocages enhanced the heat transfer, but the pressure drop was increased significantly. For an Volume 6, Issue 8, August 2017 Page 129

offset fin array it was seen that the friction factor decreases when the Reynold s number changes from 10000 to 20000 and at higher Reynolds number the friction factor is increased [4]. Experimental investigation conducted by Islam and Mozumder [5] for smooth tube and T-shaped internally fined tube revealed that the average heat transfer coefficient of finned tube was two times of smooth tube and the friction factor was five times than that of smooth tube. Li et al. [6] numerically analyzed a specially treated polymer circular tube which is attached with longitudinal fins for Reynolds number ranges from 2000 to 20000 and it was concluded that the convective heat transfer was enhanced for the oval shaped tube. Extensive numerical study for turbulent flow inside finned tube shows that after a certain height of fin, the Nusselt number increases significantly with fin height [7]. Three dimensional numerical investigations by Liting et al. [8] revealed for a wavy finned tube heat exchanger with delta winglet vortex generators that Nusselt number and friction factor both increased with angle of attac and friction factor always increased with wavy angle. Agra et al. [9] investigated numerically the hydrodynamic and thermal behaviour of two helically finned tube and two corrugated tubes with Reynolds number varies from 12,000 to 57,000 for the water flowing in the inner tube. They have found that the corrugated tubes had the higher heat transfer coefficient than the smooth tube but a lower coefficient than the helical finned tubes. Based on the above mentioned studies a comparison of fluid flow and heat transfer characteristics between smooth tube and internally finned tube for a turbulent flow conditions has been chosen for the present investigation. The experiment is performed for developing flow condition and is subsequently validated numerically using Fluent 14. 2. EXPERIMENTAL SET-UP The schematic diagram of experimental set-up has been shown in the Fig. 1. The test section consists of an aluminium tube of 1 m length with two types of geometry. One is smooth tube having 0.05 m outside diameter and 0.044 m inside diameter and the other is finned tube of same dimension that of smooth tube having four internal longitudinal rectangular-section fins spaced at equal distances attached at the internal circumference of the tube by means of casting methods. All the four fins are of equal size of 0.9 m length, 0.01 m depth and 0.003 m width. Radial holes were drilled on the outer surface of the tube along axial flow direction for the fitment of thermocouples. Air is supplied into the test pipe by a blower as shown in Fig. 1 and the air flow rate is regulated by means of regulator valve fitted at the end of the test pipe. A manometer was used to measure pressure drop across the orifice from where the air flow rate inside the tube was measured. Heating coils were wound around the aluminium pipe to supply constant heat fluxes when it was connected to a power supply with help of a magnetic contactor and temperature controller. Heat fluxes are controlled by means of electric supply, current flow is regulated by voltage regulator (Variac). Ammeter and voltmeter are used to measure the current and voltage respectively for calculation of heat flux. To avoid the heat losses to the atmosphere three layers of insulations are provided which consists of 7 mm thicness of asbestos rope, 25 mm thicness of glass wool and a PVC pipe of 3 mm thicness. Fig.1: Schematic diagram of the test rig 1. Blower 2. Test section 3. Manometer, 4. Flow regulator, 5. Thermocouple 6. Selector switch 7. Temperature indicator 8. Voltmeter, 9. Ammeter, 10. Voltage regulator, 11. On/Off switch Volume 6, Issue 8, August 2017 Page 130

The test rig is supplied modulated current by regulating it through the voltage regulator. The voltage and current are set at a particular position by watching the voltmeter and ammeter respectively. There are 9 numbers of thermocouples spaced at equal distances on the outer surface of the test pipe to measure the temperatures axially at different nodes. One thermocouple was attached at inlet and three thermocouples were attached at the outlet to measure the inlet and outlet temperatures respectively. At the outlet three thermocouples are placed radially at different distance and the average temperature of three thermocouples readings is the measure of outlet temperature. A snap view of the experimental set-up has been shown in Fig. 2. Fig.2: Snap view of experimental set up 3. MATHEMATICAL FORMULATION Fig.3: Internal fins on inner periphery of the tube The numerical simulations are performed for an internally finned tube of diameter, D and length, L as shown in the Figure 3. Air at room temperature is allowed to enter into the tube from one end and the other end is exposed to atmosphere. Rectangular fins are attached at the inner periphery of the tube and runs in axial direction. The investigation started with four rectangular fins and subsequently fin numbers changed by eeping the mass flow rate of air was ept constant. The flow field in the domain would be computed by using incompressible, 2D axi-symmetric, Navier-Stoes equations with two-equation based -ε turbulence model along with the energy equations. The fluid used is air, at temperatures taen between 300 to 500 K. Volume 6, Issue 8, August 2017 Page 131

Fig. 4: Schematic diagram of computational domain and the boundary condition applied to it (a) finned tube; (b) unfinned tube Fig.5: Cross sectional view of the internal finned tube showing the meshes inside the tube and around the fins Two cylindrical aluminium pipes exactly of the same size and shape are used both for numerical and experiment investigation as shown in the Fig.4. For smooth tube two dimensional axi-symmetric models has been chosen. Fluent 14 is used to determine the flow field and temperature field in the finned tube domain would be computed by using 3-D (two dimensional axi-symmetric model for smooth tube), incompressible Navier-Stoes equations with a two equation based - turbulence model along with the energy equation. Air is treated to be incompressible at room temperature is used in the simulation at injection velocity (which is below 10 m/s). Fig. 4a and 4b shows the boundary conditions respectively for finned tube and smooth tube. As the density is taen as a function of temperature according to ideal gas equation therefore SIMPLE algorithm with PRESTO (Pressure Staggered Option) scheme has been used for better convergence. Under relaxation factors (0.3 for pressure, 0.7 for momentum and 0.8 for and ) were used for the convergence of all the variables. Convergence of the discretized equations were said to have been achieved when the whole field residual for all the variables fell below 10-3 except energy equation and for energy equation residual was set 10-6. Governing Equations Conservation of mass.( v ) 0 Conservation of momentum vv p v Conservation of energy eff.. D ( T ) t T D t x i P r P rt x i Turbulence inetic energy t. v. G Turbulent rate of dissipation t. v. C 1 G C 2 Where G =Generation of turbulent inetic energy due to mean velocity gradient and turbulent or eddy viscosity 2 t C C 1 1.44; C 2 1.92; C 0.09; 1.0; 1.3, P rt 1 (1) (2) (3) (4) (5) Volume 6, Issue 8, August 2017 Page 132

The effect of fin number on wall temperature can be seen from the Figure 6. The present computations have been performed on rectangular sectioned longitudinal finned tube of length 1 m and diameter 70 mm. As the fin number was increased from 0 to 8 the wall temperature is dropped to the lowest value and after that when we increase the fin number further (i.e. n=12, 16 and 20) the wall temperature is raised again. 1.6 1.5 1.4 n = 0 q = 3000 W/m 2, L = 1 m n = 4 D = 70 mm, H = 10 mm. n = 8 t = 5 mm, m = 0.0196 g/s n = 12 n = 16 n = 20 T sx /T 1.3 1.2 1.1 0.0 0.2 0.4 0.6 0.8 1.0 x/l Wall temperature of the tube as a function of fin number Fig.6: Effect of fin numbers on wall temperature 400 350 300 250 n = 0 n = 4 n = 8 n = 16 q = 3000 W/m 2, L = 1 m D = 70 mm, H = 10 mm. t = 5 mm, m = 0.0196 g/s Nu x 200 150 100 50 0.0 0.2 0.4 0.6 0.8 1.0 x/l Fig.7: Effect of fin numbers on Nusselt number As the number of fin is increased in an internal finned tube, the transfer of heat to the air is increased up to a certain number of fins but after that obstruction is created by the fins within the tube and the heat transfer rate is adversely affected and the wall temperature is increased. 0.16 0.14 0.12 q = 3000 W/m 2, L = 1 m D = 70 mm, H = 10 mm. t = 5 mm, m = 0.0196 g/s n = 0 n = 4 n = 8 n = 12 n = 16 f x 0.10 0.08 0.06 0.04 0.0 0.2 0.4 x/l 0.6 0.8 1.0 Fig.8: Effect of fin number on friction factor Volume 6, Issue 8, August 2017 Page 133

This is also visualised from Figure 7 that the Nusselt number is highest for 8 numbers of fins and the Nusselt number is increased approximately 2.5 times for 8 numbers fins compared to plain tube. So it can be concluded that the convective resistance is minimum when the fin number is 8 and after that it increases significantly with the fin numbers. However the pressure drop is increased along with the fin numbers and due to that there was a sharp rise in the friction factor that can be seen from Figure 8. 4. CONCLUSIONS Numerical and experimental investigations have been performed to study the thermo-fluid behaviour of finned tube and plain tube. Experiment was performed for a constant Reynolds and wall heat flux. From the analysis the following conclusions can be drawn: The wall temperature of internally finned tube was found to have a lowest value for 8 numbers of fins which could have been reduced by 16% compared to a plain tube. The Nusselt number is highest for 8 numbers of fins and the Nusselt number is increased approximately 2.5 times for 8 numbers fins compared to plain tube. The pressure drop is increased along with the fin numbers and due to that there was a sharp rise in the friction factor. References [1] Liu, X., Jensen, M. K., 2001, Geometry Effects on Turbulent Flow and Heat Transfer in Internally Finned Tube, Journal of Heat Transfer 123, p. 1035. [2] Moores, K. A., Joshi, K. Y., 2003, Effect of Tip Clearance on the Thermal and Hydrodynamic Performance of a Shrouded Pin Fin Array, Journal of Heat Transfer 125, p. 999. [3] Moon, S.W., Lau, S.C., 2003, Heat Transfer Between Blocages with Holes in a Rectangular Channel, Journals of heat transfer 125, p.587-594. [4] Michna, G. J., Jacobi, A. M., Burton, R. L., 2007, An Experimental Study of the Friction Factor and Mass Transfer Performance of an Offset Strip Fin Array at Very High Reynold s Numbers, Journal of heat transfer 129, p.1134. [5] Islam, M. A., Mozumder, A. K., 2009, Forced Convection Heat Transfer Performance of an Internally Finned Tube, Journal of Mechanical Engineering 40(1), p.54. [6] Li, Z., Davidson, J., Mantell, S., 2004, Heat Transfer Enhancement Using Shaped Polymer Tubes: Fin Analysis, Journals of Heat transfer 126, p.211. [7] Al-Sarhi, A., Abu-Nada, E., 2005, Characteristics of Forced Convection Heat Transfer in Vertical Internally Finned Tube, International Communications in Heat and Mass Transfer 32, p.557. [8] Tian, L., He, Y., Chu, P., Tao, W., 2009, Numerical Study of Flow and Heat Transfer Enhancement by using Delta Winglets in a Triangular Wavy Fin and Tube Heat Exchanger, Journal of heat transfer 131, p. 091901-1. [9] Agra, O., Demir, H., Atayilmaz, S., Kantas, F., Dalilic, A., 2011, Numerical Investigation of Heat transfer and Pressure Drop in Enhanced Tube, International Communications in Heat and Mass Transfer 38, p.1384. Volume 6, Issue 8, August 2017 Page 134