Report No.:STRD1509157R2 Page1of 6 Applicant Name:FIMOR S.A..S Applicant Add:210,RUE DU PLOYGONE F72058 LE MANSCEDEX 2,FRANCE Sample Name:Serilor LC 40shA green Item No.: / Material:PU Supplier: FIMOR Reference Item No.:/ Sample Receiving Date:20150929 Testing Period:20150929 to 20151010 Tests Conducted:As requested by the applicant,for details refer to attached page(s). ****************************************************************** ************** Conclusion: Conclusion Pass Cd Pb Hg Cr 6+ PBBs PBDEs DBP BBP DEHP DIBP See test co conducted ****************************************************************** ************** Tested by: Compiled by : Approved by: Tel:075599663308 Fax:075533663309 Web:www.semtest.com.cn
Report No.:STRD1509157R2 Page2of 6 Test Result: Specimen No. SN1 SEM Sample ID Description D1509157 Green plastic Test Method : (1)With reference to IEC 623215:2013, determination of Cadmium by ICPOES. (2)With reference to IEC 623215:2013, determination of Lead by ICPOES. (3)With reference to IEC 623214:2013, determination of Mercury by ICPOES. (4)With reference to IEC 62321:2008, determination of Hexavalent Chromiumm by Colorimetric M ethod using UVVis. (5)With reference to IEC 62321:2008, determination of PBBs and PBDEs by GCMS.) (6)With reference to EN 14372:2004, determination of phthalates by GCMS.) 1. RoHS Directive 2011/65/ /EU ) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium (Cr(VI)) N.D. Sum of PBBs Monobromobiphenyl Dibromobiphenyl Tribromobiphenyl Tetrabromobiphenyl Pentabromobiphenyl Hexabromobiphenyl Heptabromobiphenyl Octabromobiphenyl Nonabromobiphenyl Decabromobiphenyl Sum of PBDEs Monobromodiphenyl ether Dibromodiphenyl ether Tribromodiphenyl ether Test Result MDL N.D. 2 N.D. 2 29 2 Tetrabromodiphenyl ether Pentabromodiphenyl ether Hexabromodiphenyl ether Limit 100 Tel:075599663308 Fax:075533663309 Web:www.semtest.com.cn
Report No.:STRD1509157R2 Page3of 6 Test Result MDL Heptabromodiphenyl ether Octabromodiphenyl ether Nonabromodiphenyl ether Decabromodiphenyl ether Limit Notes : (1) The maximum permissible limit is quoted from the directive 2011/65/EU, Annex II. 2. Phthalate Dibutyl Phthalate (DBP) Benzylbutyl Phthalate (BBP) Bis(2ethylhexyl) Phthalate (DEHP) Diisobutyl Phthalate (DIBP) Test Result MDL Limit N.D. 30 N.D. 30 N.D. 30 N.D. 30 CAS No. 84742 85687 117817 84695 Tel:075599663308 Fax:075533663309 Web:www.semtest.com.cn
Report No.:STRD1509157R2 Page4of 6 Testing Flow Chart 1. RoHS Directive(2011/65/EU) a. Test for Cd/Pb/Hg contents Weighted sample was put into a microwave digestion/beak Add digest reagent Digest the sample in microwave digestion oven/hotplate The digested solution was transferred into a volumetric flask Made up with deionized water Determined by inductively coupled plasma optical emission spectrometer/atomic absorption spectrometer b. Test for Cr 6+ content Weighted sample was put into a conical flask Add digestion solution and heat in constant temperature shaking water baths Adjust the PH of extracted solution to 7.5±0.5and transfer into a volumetric flask,made up with deionized water Add diphenylcarbazide solution Adjust the PH 2.0±0.5and make up with deionized water Determined by UVvisible spectrophotometer c. Test for PBBs/PBDEs contents Weighted sample was put into a glass tube Extracted by solvent in ultrasonic extraction Concentrate the extract Transfer the extract into a volumetric flask Made up with organic solvent Determined by gas chromatographicmass spectrometer Tel:075599663308 Fax:075533663309 Web:www.semtest.com.cn
Report No.:STRD1509157R2 Page5of 6 d. DBP BBP DEHP DIBP Weighted sample was put into a glass tube Extracted by solvent in ultrasonic extraction Concentrate the extract Transfer the extract into a volumetric flask Made up with organic solvent Determined by gas chromatographicmass spectrometer Tel:075599663308 Fax:075533663309 Web:www.semtest.com.cn
Report No.:STRD1509157R2 Page6of 6 Sample Photo: Tel:075599663308 Fax:075533663309 Web:www.semtest.com.cn