IES LM MEASUREMENT AND TEST REPORT. For

Similar documents
IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

IES LM MEASUREMENT AND TEST REPORT For

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT For

IES LM MEASUREMENT AND TEST REPORT For. Eiko Limited W. 84th Street,Shawnee, KS, USA. Test Model: LEDP-13WPAR30/NFL/830-DIM

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50

Morris Products 53 Carey Road, Queensbury, NY 12804

TEST REPORT For Company:

IES LM MEASUREMENT AND TEST REPORT For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227

IES LM TEST REPORT For Shenzhen sunper opto co., ltd

IES LM TEST REPORT For EIKO GLOBAL, LLC

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

IESLM-79-08TESTREPORT For KINGLUMI CO., LTD

Test report of IES LM Approved Method: Electrical and Photometric

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd.

ENERGY STAR PROGRAM REQUIREMENTS FOR LUMINAIRES (LIGHT FIXTURES) (VERSION 2.0) MEASUREMENT AND TEST REPORT For

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

Cat# LED Linear High Bay 100W

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Photometric Test Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Photometric Test Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Photometric Test Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

GM LIGHTING 9830 W 190th St, Torrance, CA 90503

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

Transcription:

IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB06W27-50K-D-T3-A-P Report Type: Test Engineer: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution, THD, Power Factor Daniel Duan Report Number: RSZ160311512-10 Test Date: 2016-03-18 to 2016-03-21 Report Date: 2016-03-22 Reviewed By: Prepared By: Test Facility: Jeanne Han/Safety Manager Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is 200707-0. STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

1. Product Description General Information: One sample was received on 2016-03-11 and used for testing. Sample No.: RSZ160311512-S01 Model: WSD- SB06W27-50K-D-T3-A-P Model Tested: WSD-SB06W27-50K-D-T3-A-P Manufacturer: Brand Name: Product Designation: Dimmable: Burning Time Before Test: WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED WISDOM Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Architectural Flood and Spot Luminaires Non-Dimmable 0 hour(for New Products) Rated Values: Rated Voltage/Frequency: AC120-277V 60Hz Rated Power: 60W Nominal Light Output: 7200 lm Nominal CCT: 5000K Nominal CRI: 80 2. Standards Used IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits Related Power Quality Requirements for Lighting 3. Description of Test Equipment Device Manufacture Model No Serial No Test Range Integrating Sphere Spectral photometer Calibration Calibration date due date SENSING SPR-600 S09008 25~50 2016-03-10 2017-03-09 SENSING SPR3000 90902027 350nm~800nm 2016-03-10 2017-03-09 Power Meter YOKOGAWA WT-210 91j926132 15/30/60/150/300/600 V 2016-03-04 2017-03-03 AC Power Supply ALL Power APW-105N 970663 220V±10% 50HZ 2016-03-04 2017-03-03 Standard Light Source EVERFINE D204 01331191 24V/100W 2015-08-27 2016-08-26 Thermal Meter SENSING N/A N/A 25 50 2016-03-10 2017-03-09 DC Power Supply ITECH AC Power Supply EVERFINE DC Power Supply IT6154 VPS1030 PWM 0061 0417 6471 0010 19 0~32V 2016-03-04 2017-03-03 1012017 0-150V, 0-300V 2016-03-04 2017-03-03 EVERFINE WY12010 1009009 30V/5A 2016-03-04 2017-03-03 Power Meter YOKOGAWA WT-210 91KB35700 15/30/60/150/300/600 V 2016-03-04 2017-03-03 Goniophotometer EVERFINE GO-R5000 YG108492N10120001 1600mm,3000W/10A 2016-03-10 2017-03-09 Wireless Remote Sensor N/A 433MHz N/A 0 ~50 ;-20 ~60 2015-03-24 2016-03-23 Report No. RSZ160311512-10 Page 2 of 13 The NVLAP Lab Code is 200707-0.

Device Manufacture Model No Serial No Test Range Calibration Calibration date due date Standard Light Source EVERFINE D908 1012003 N/A 2015-09-08 2016-09-07 Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI). 4. Test Method Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25 C±1 C during measurement. And relative humidity is less than 65%. Integrating Sphere System The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement. The system and standard light source has been calibrated regularly and traceable to the National Primary Standards. 4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report. The uncertainty of the light output (luminous flux) measurements is U=2.1% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=32K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=2.1 (K=2), at the 95% confidence level. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level. Goniophotometer System The goniophotometer system is calibrated by standard light source before measurement. The standard light source has been calibrated regularly and traceable to the National Primary Standards. Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report. The uncertainty of the luminous intensity is U=2.82% (K=2), at the 95% confidence level. Additional Test The Additional Test item may not be covered by IESNA LM-79-2008. Additional test including power factor, off-state power and THD, was measured by Digital Power Meter after stabilized at 25 C±1 C.Test voltage for THD and power factor test would be equal to rated voltage or, in case of a voltage range, maximum value of that range. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level. Report No. RSZ160311512-10 Page 3 of 13 The NVLAP Lab Code is 200707-0.

5. Test Result [Integrating Sphere System] Total operating time for integrating sphere test: 1.0 hours Test orientation: Downward Electrical Measurement Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor 120.04 60 0.5148 61.6 0.997 Photometric Measurement Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/w) CCT (K) Duv 7165.79 22.303 116.328 4908 0.0023 Chromaticity Coordinate x y u v u' v' 0.3483 0.3588 0.2108 0.3257 0.2108 0.4886 Color Rendering Index Ra 83.1 R1 R2 R3 R4 81 88 92 83 R5 R6 R7 R8 81 82 88 69 R9 R10 R11 R12 12 70 82 57 R13 R14 R15 83 95 76 Report No. RSZ160311512-10 Page 4 of 13 The NVLAP Lab Code is 200707-0.

Relative Spectral Power Distribution 1.2 1.0 0.8 0.6 0.4 0.2 0.0 380 440 500 560 620 680 740 800 nm mw nm mw nm mw nm mw nm mw 380 8.693E-03 465 2.887E-01 550 4.057E-01 635 2.850E-01 720 2.981E-02 385 6.461E-03 470 2.145E-01 555 4.106E-01 640 2.601E-01 725 2.556E-02 390 5.020E-03 475 1.680E-01 560 4.186E-01 645 2.354E-01 730 2.199E-02 395 3.680E-03 480 1.602E-01 565 4.202E-01 650 2.127E-01 735 1.882E-02 400 2.808E-03 485 1.715E-01 570 4.270E-01 655 1.901E-01 740 1.642E-02 405 3.372E-03 490 1.946E-01 575 4.288E-01 660 1.679E-01 745 1.428E-02 410 5.522E-03 495 2.268E-01 580 4.332E-01 665 1.469E-01 750 1.210E-02 415 1.109E-02 500 2.639E-01 585 4.330E-01 670 1.296E-01 755 1.094E-02 420 2.385E-02 505 2.960E-01 590 4.311E-01 675 1.123E-01 760 9.548E-03 425 4.702E-02 510 3.213E-01 595 4.284E-01 680 9.776E-02 765 8.240E-03 430 9.465E-02 515 3.418E-01 600 4.179E-01 685 8.485E-02 770 7.396E-03 435 1.847E-01 520 3.574E-01 605 4.078E-01 690 7.411E-02 775 6.494E-03 440 3.465E-01 525 3.703E-01 610 3.967E-01 695 6.340E-02 780 5.965E-03 445 5.929E-01 530 3.801E-01 615 3.756E-01 700 5.490E-02 450 7.037E-01 535 3.864E-01 620 3.571E-01 705 4.624E-02 455 5.314E-01 540 3.920E-01 625 3.336E-01 710 3.988E-02 460 3.754E-01 545 3.981E-01 630 3.107E-01 715 3.427E-02 Report No. RSZ160311512-10 Page 5 of 13 The NVLAP Lab Code is 200707-0.

CIE 1931 x y Chromaticity Diagram 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 7-Step & 4-Step Chromaticity Quadrangles 0.45 0.40 0.35 0.30 0.30 0.35 0.40 0.45 0.50 0.55 sample 7-STEP 2200K 7-STEP 2500K 7-STEP 2700K 7-STEP 3000K 7-STEP 3500K 7-STEP 4000K 7-STEP 4500K 7-STEP 5000K 7-STEP 5700K 7-STEP 6500K Report No. RSZ160311512-10 Page 6 of 13 The NVLAP Lab Code is 200707-0.

[Goniophotometer System] Total operating time for luminous intensity distribution: 1.0 hours Test orientation: Downward Electrical Measurement Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor 120.02 60 0.5185 61.3 0.9851 Photometric Measurement Luminous Flux (lm) Efficacy (lm/w) I max (cd) S/MH (C0/180) S/MH (C90/270) 7213.29 117.67 3669 1.95 1.09 Luminous Intensity Distribution C0/180 C45/225 C90/270 C135/315 AVG. Beam Angle (50% Imax): 130.6 46.1 55.8 45.8 69.6 Field Angle (10% Imax): 161.9 141.0 134.7 140.9 144.6 Report No. RSZ160311512-10 Page 7 of 13 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data γ C Bay Area Compliance Laboratories Corp. (Shenzhen) 0 22.5 45 67.5 90 112.5 135 157.5 0.0 1347 1347 1347 1347 1347 1347 1347 1347 5.0 1359 1392 1415 1415 1432 1431 1425 1410 10.0 1413 1478 1501 1505 1509 1531 1552 1533 15.0 1544 1665 1665 1608 1615 1685 1788 1795 20.0 1812 1996 1949 1775 1744 1901 2163 2210 25.0 2181 2481 2388 2034 1966 2257 2668 2711 30.0 2576 2922 2924 2564 2518 2828 3184 3122 35.0 3018 3242 3421 3140 2947 3392 3567 3387 40.0 3206 3582 3539 3115 2866 3295 3637 3616 45.0 2881 3542 3353 3032 2668 3113 3405 3264 50.0 2115 2925 3235 2751 2246 2795 3167 2558 55.0 1714 2067 2988 2115 1642 2146 2748 1976 60.0 1454 1778 2424 1820 1879 1795 2059 1788 65.0 747 1502 1549 1658 1211 1563 1401 1220 70.0 340 702 1050 687 458 687 1009 580 75.0 236 305 491 267 187 259 485 286 80.0 150 160 193 126 95 123 188 148 85.0 55 64 78 57 43 56 68 51 90.0 0 4 2 2 4 1 5 0 95.0 0 0 0 0 0 0 0 0 100.0 1 0 0 0 0 0 0 0 105.0 1 0 0 0 0 0 0 1 110.0 1 0 0 0 0 0 0 1 115.0 1 1 0 0 0 0 0 1 120.0 1 1 0 0 0 0 0 1 125.0 1 1 1 0 0 0 1 1 130.0 1 1 1 1 0 1 1 1 135.0 1 1 1 1 1 1 1 1 140.0 1 1 1 1 1 1 1 1 145.0 2 1 1 1 1 1 1 2 150.0 2 2 2 1 1 1 2 2 155.0 2 2 2 2 1 2 2 2 160.0 2 2 2 2 2 2 2 2 165.0 2 2 2 2 2 2 2 2 170.0 2 2 2 2 2 2 2 2 175.0 2 2 2 2 2 2 2 2 180.0 2 2 2 2 2 2 2 2 Report No. RSZ160311512-10 Page 8 of 13 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data (cont.) γ C Bay Area Compliance Laboratories Corp. (Shenzhen) 180 202.5 225 247.5 270 292.5 315 337.5 0.0 1347 1347 1347 1347 1347 1347 1347 1347 5.0 1368 1331 1300 1268 1268 1272 1293 1328 10.0 1452 1344 1242 1188 1177 1196 1241 1321 15.0 1634 1418 1205 1098 1091 1105 1182 1345 20.0 1950 1579 1208 1032 1032 1042 1166 1479 25.0 2309 1736 1236 987 1004 992 1190 1650 30.0 2740 1866 1229 941 996 956 1202 1807 35.0 3064 1926 1191 899 983 908 1178 1920 40.0 3084 1932 1132 838 950 852 1138 1992 45.0 2610 1781 1039 767 860 767 1056 1885 50.0 1919 1491 910 666 733 673 939 1611 55.0 1629 1116 720 550 585 560 760 1219 60.0 1296 755 514 420 419 432 539 816 65.0 676 466 337 283 220 296 348 521 70.0 312 276 223 174 163 180 225 303 75.0 245 214 161 122 112 125 161 221 80.0 150 135 100 83 83 85 105 145 85.0 51 45 43 46 46 48 50 55 90.0 0 0 0 0 0 0 0 0 95.0 0 0 0 0 0 0 0 0 100.0 0 0 1 0 0 1 0 0 105.0 0 1 1 1 1 1 1 1 110.0 1 1 1 1 1 1 1 1 115.0 1 1 1 1 1 1 1 1 120.0 1 1 1 1 1 1 1 1 125.0 1 1 1 1 1 1 1 1 130.0 1 1 1 1 1 1 1 1 135.0 1 1 2 2 2 2 2 2 140.0 1 1 2 2 2 2 2 2 145.0 1 1 2 2 2 2 2 2 150.0 1 1 1 2 2 2 2 2 155.0 1 1 1 1 2 2 2 2 160.0 1 1 1 1 2 2 1 2 165.0 1 1 1 1 2 2 1 2 170.0 1 1 1 1 2 2 2 2 175.0 2 2 1 2 2 2 2 2 180.0 2 2 2 2 2 2 2 2 Report No. RSZ160311512-10 Page 9 of 13 The NVLAP Lab Code is 200707-0.

Average Area Illumination Figure Angle: 69.6. Flux out: 2100.0 lm. Height (m) Diameter (cm) E avg (lx) E max (lx) 0.5 69.50 5453.0 8254.0 1.0 139.00 1363.0 2063.0 1.5 208.51 605.9 917.1 2.0 278.01 340.8 515.9 2.5 347.51 218.1 330.1 3.0 417.01 151.5 229.3 3.5 486.51 111.3 168.4 4.0 556.01 85.2 129.0 4.5 625.52 67.3 101.9 5.0 695.02 54.5 82.5 Report No. RSZ160311512-10 Page 10 of 13 The NVLAP Lab Code is 200707-0.

Zonal Lumen Density Measurement Deg Flux (lm) % Deg Flux (lm) % 0-5 32.3 0.45 0-5 32.3 0.45 5-10 98.1 1.36 0-10 130.4 1.81 10-15 168.8 2.34 0-15 299.2 4.15 15-20 254.2 3.52 0-20 553.4 7.67 20-25 366.1 5.08 0-25 919.5 12.75 25-30 507.1 7.03 0-30 1426.7 19.78 30-35 673.2 9.33 0-35 2099.9 29.11 35-40 807.3 11.19 0-40 2907.2 40.30 40-45 871.3 12.08 0-45 3778.5 52.38 45-50 846.5 11.74 0-50 4624.9 64.12 50-55 747.7 10.36 0-55 5372.7 74.48 55-60 641.8 8.90 0-60 6014.5 83.38 60-65 528.1 7.32 0-65 6542.6 90.70 65-70 331.4 4.60 0-70 6873.9 95.30 70-75 176.2 2.44 0-75 7050.2 97.74 75-80 96.0 1.33 0-80 7146.2 99.07 80-85 49.5 0.69 0-85 7195.7 99.76 85-90 12.0 0.16 0-90 7207.7 99.92 90-95 0.2 0.01 0-95 7207.9 99.93 95-100 0.2 0.00 0-100 7208.1 99.93 100-105 0.2 0.00 0-105 7208.3 99.93 105-110 0.3 0.01 0-110 7208.6 99.94 110-115 0.3 0.00 0-115 7208.9 99.94 115-120 0.4 0.00 0-120 7209.3 99.94 120-125 0.4 0.01 0-125 7209.7 99.95 125-130 0.4 0.01 0-130 7210.1 99.96 130-135 0.5 0.00 0-135 7210.5 99.96 135-140 0.5 0.01 0-140 7211.0 99.97 140-145 0.5 0.00 0-145 7211.5 99.97 145-150 0.4 0.01 0-150 7211.9 99.98 150-155 0.4 0.01 0-155 7212.3 99.99 155-160 0.4 0.00 0-160 7212.7 99.99 160-165 0.3 0.01 0-165 7212.9 100.00 165-170 0.2 0.00 0-170 7213.1 100.00 170-175 0.1 0.00 0-175 7213.3 100.00 175-180 0.0 0.00 0-180 7213.3 100.00 Report No. RSZ160311512-10 Page 11 of 13 The NVLAP Lab Code is 200707-0.

[Additional Test] Test Item Test Voltage (V) Frequency (Hz) Test Result Power Factor: 277.0 60 0.9621 Total Harmonic Distortion: 277.0 60 13.92% Total Harmonic Distortion: 120.0 60 9.51% 6. Product Photo Report No. RSZ160311512-10 Page 12 of 13 The NVLAP Lab Code is 200707-0.

7. Product Test orientation in the Goniophotometer Bay Area Compliance Laboratories Corp. (Shenzhen) ***********END OF REPORT*********** Report No. RSZ160311512-10 Page 13 of 13 The NVLAP Lab Code is 200707-0.