AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances

Similar documents
AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances KEYWORDS

AppNote 2/1999. Automated Sample Fractionation and Analysis Using a Modular LC-GC System

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

AppNote 2/1996. Andreas Hoffmann Gerstel GmbH & Co.KG, Aktienstrasse , D Mülheim an der Ruhr, Germany

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

AppNote 7/1994. Friedhelm Rogies, Andreas Hoffmann Gerstel GmbH & Co.KG, Aktienstrasse , D Mülheim an der Ruhr, Germany

AppNote 1/2004. Use of a Mass Spectral Based Chemical Sensor to Discriminate Food and Beverage Samples: Olive Oils and Wine as Examples KEYWORDS

AppNote 8/2008. A New Purge Tool for Use with Automated Headspace Analysis KEYWORDS ABSTRACT

AppNote 2/2002. Discrimination of Soft Drinks using a Chemical Sensor and Principal Component Analysis KEYWORDS ABSTRACT

AppNote 4/2008. Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps KEYWORDS ABSTRACT

AppNote 14/2012. Thermal Gravimetric Analysis/Mass Spectrometry Simulation using the GERSTEL Automated Pyrolyzer KEYWORDS ABSTRACT

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

AppNote 15/2012. Large Volume Injection with Solvent Venting - Application to Trace Detection of Analytes in Water INTRODUCTION

AppNote 1/2007. Automated Dynamic Headspace Sampling using Replaceable Sorbent Traps KEYWORDS ABSTRACT

The Focus Robotic Sample Processor as a Tool for the Multiple Analysis of Samples using Complementary Techniques

AppNote 4/2005. A Selectable Single or Multidimensional. Fraction Collection and Dual Detection for Trace Analysis of Complex Samples KEYWORDS

AppNote 2/2001. Stir Bar Sorptive Extraction: Enhancing Selectivity of the PDMS Phase KEYWORDS ABSTRACT

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to En vi ron men tal Aqueous Samples INTRODUCTION

AppNote 8/2002 KEYWORDS ABSTRACT. Electronic Nose, Fast GC, Headspace Analysis, Chemometrics,

Determination of Volatile Substances Proof of Food Adulteration

TechNote 5/2002 KEYWORDS ABSTRACT. SBSE, Twister, Thermal Desorption

AromaOffi ce: Application of a Novel Linear Retention Indices Database to a Complex Hop Essential Oil

Analysis of Terpenes in Cannabis Using the Agilent 7697A/7890B/5977B Headspace GC-MSD System

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

AppNote 4/1998. New Developments in Multi-Dimensional Capillary Gas Chromatography KEYWORDS ABSTRACT

Analysis of Food Samples using Thin Film Solid Phase Microextraction (TF-SPME) and Thermal Desorption GC/MS

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

AppNote 3/2014. Analysis of Aroma Compounds in Edible Oils by Direct Thermal Desorption GC/MS using Slitted Microvials KEYWORDS ABSTRACT

Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles

AppNote 6/2010. part a. Alternative Procedure for Extraction and Analysis of PAHs in Seafood by QuEChERS-SBSE-GC-MS KEYWORDS ABSTRACT

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Expectations for GC-MS Lab

AppNote 2/2004. Analysis of Packaging Materials using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

U.S. EPA Method 8270 for multicomponent analyte determination

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Application. Gas Chromatography February Introduction

AppNote 6/2012. Flavor and Fragrance Analysis of Consumer Products - Dynamic Headspace Compared to Some Traditional Analysis Approaches KEYWORDS

AppNote 3/2007 KEYWORDS INTRODUCTION. Beverage, Detector, Headspace, Quality Control

AppNote 2/2012. Determining Phenolic Compounds in Whisky using Direct Large Volume Injection and Stir Bar Sorptive Extraction KEYWORDS ABSTRACT

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

AppNote 1/2011 KEYWORDS ABSTRACT

Off-gassing of Rubber Particles Used for Athletic Fields using Automated Dynamic Headspace Sampling

Multi-residue analysis of pesticides by GC-HRMS

GERSTEL Thermal Desorption System TDS 3 The GERSTEL TDS 3 is a flexible multi-functional thermal desorption system for highly sensitive and accurate d

GAS CHROMATOGRAPHY (GC)

Determination of volatiles in Food sample preparation strategies and techniques Dr Kathy Ridgway

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns

Sulfotepp impurities in Chlorpyrifos EC formulations

AppNote 5/2002. Characterization of a Mass Spectrometer based Electronic Nose for Routine Quality Control Measurements of Flavors KEYWORDS ABSTRACT

Gas Chromatography (GC)

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

Analysis of BTEX in Natural Water with SPME

Thermal Desorption Unit TDU

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Author. Abstract. Introduction

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

AppNote 10/2012. Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages KEYWORDS

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Highly Sensitive and Rugged GC/MS/MS Tool

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Determination of Elemental Sulfur in Explosives and. Explosive Residues by Gas Chromatography-Mass Spectrometry. Kimberly S.

AppNote 12/2008 KEYWORDS ABSTRACT

Dynamic headspace (DHS) technique: set-up and parameter control for GC/MS analysis of odorant formulations

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

Automated and accurate component detection using reference mass spectra

Rapid Analysis of Food and Fragrances Using High-Efficiency Capillary GC Columns. Application. Authors. Abstract. Introduction

VGA-100 Instrument Detection Limits and Linearity

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

GCXGC-qMS with Total Flow Modulation for Volatile secondary metabolites analysis from organically-grown apples by HS-SPME

AppNote 3/1998 KEYWORDS ABSTRACT. Beverage, Food & Flavor, PTV, Large Volume Injection, Headspace, Thermal Desorption.

AppNote 8/2011 KEYWORDS ABSTRACT INTRODUCTION

AppNote 2/1996. Andreas Hoffmann Gerstel GmbH & Co.KG, Eberhard-Gerstel-Platz 1, D Mülheim an der Ruhr, Germany

GC/MS Application Note

Method of determination of phtalates in spirituous beverages by gaschromatography/mass

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

Residual solvents analysis using an Agilent Intuvo 9000 GC system

Analysis of pesticide residues using various GC/MS systems. Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic

Detection of Chemical Warfare Agents by Transportable GC/MS

Yokogawa Analytical Systems Inc., Nakacho, Musashino-shi, Tokyo , Japan.

AppNote 3/2012. Rapid Automated Screening of Extractable Compounds in Materials for Food Packaging, Medical or Technical Purposes KEYWORDS ABSTRACT

Transcription:

G L O B A L A N A L Y T I C A L S O L U T I O N S AppNote 7/2003 Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances Vanessa R. Kinton, Edward A. Pfannkoch, Jacqueline A. Whitecavage, John Thorp Gerstel, Inc., Caton Research Center, 1510 Caton Center Drive, Suite H, Baltimore, MD 21227, USA KEYWORDS Flavors, gas chromatography, mass spectrometry, retention time locking, SPME, SBSE ABSTRACT Analysis of foods, flavors and fragrances is commonly done by capillary gas chromatography coupled to a range of detectors depending on the particular needs of the analysis. Using Retention Time Locked (RTL) methods can facilitate the transfer from one instrument to another, particularly if different detectors (eg. MSD and FID) are used. Although liquid or headspace injection methods are often used for these analyses, difficult and time-consuming sample preparation steps, or lack of sensitivity are commonly encountered. Automated Solid Phase Microextraction (SPME) or Stir Bar Sorptive Extraction (SBSE) can often provide substantial improvements to existing methods. In this contribution, we illustrate the use of RTL methods and the Agilent RTL Flavor Library when the GERSTEL MPS 2 autosampler is used to automate either SPME or SBSE as sample extraction and introduction technique. Procedures are given for calibrating the GC method using

either technique. RTL methods created for both sample introduction techniques could be moved from a GC- FID to a GC-MSD system with different column head pressure requirements. Calibrated RTL SPME or SBSE methods were then used to analyze several sample types that otherwise would pose significant matrix interference or detection limit issues. Example chromatograms with identifications based on the RTL flavor library are given. INTRODUCTION Analysis of flavor and fragrance composition can be challenging. Flavors and fragrances are usually complex mixtures that may contain many constituents that could include terpenes, diterpenes, sesquiterpenoids, etc. Common techniques used to analyze these types of samples are gas chromatography (GC) coupled to either flame ionization detector (FID) or mass spectrometer (MS). GC/MS is widely used to separate and tentatively identify flavor constituents. There are several techniques that introduce flavor components into GC instruments. These include static headspace or enrichment techniques such as solid phase microextraction (SPME) or, more recently, stir bar sorptive extraction (SBSE). Regardless of the method used for sample introduction the identity obtained with the mass spectrometer for the flavor components is considered tentative. In order to have full confidence of the identity of a compound, standards are necessary to validate the MS findings. Identification of flavor components with an MS detector is also difficult because usually they are mixtures of compounds with similar mass fragmentation. Since isomers give similar spectra, retention indices are commonly used to complement the information obtained with the MS. There are published libraries with retention indices for flavor and fragrances, but these libraries depend on the column type, linear velocity of the carrier gas, oven profile, etc. Due to the dependence of these experimental conditions, the retention indices can be difficult to reproduce. A technique known as retention-time-locking (RTL) can compensate for the disadvantages mentioned before of using GC/MS. The ability to lock a GC/MS method and subsequently running samples under locked conditions has the advantage of providing complementary information to the identification obtained using a mass spectral library. When a GC/MS method is locked, the identification of the individual components is carried out with the mass spectral profile and also by its retention time. The extra information is particularly useful when isomers with similar mass spectra are encountered. In this study, an RTL flavor database created by David et al [1]. was used to analyze different beverage samples. The combination of the RTL capabilities along with a diversity of sample introduction into a GC creates a versatile way of analyzing flavor and fragrances samples. EXPERIMENTAL Instrumentation. All analyses were performed on a GC (6890, Agilent Technologies) with mass selective detection (MSD). The instrument was equipped with a Thermal Desorption unit with autosampler (TDS 2 & TDS A, Gerstel), a Multipurpose sampler with SPME capability (MPS 2, Gerstel) and a PTV inlet (CIS 4, Gerstel). Analysis Conditions. Column: 30m HP-5 (Agilent), d i = 0.25mm, d f = 0.25mm Pneumatics: He, P i = 10.6 psi (flavors), P i = 20.3 psi (pesticides) constant pressure Oven: 60 C, 3 C/min, 240 C for flavors 70 C (2 min), 25 C/min, 150 C, 3 C/min, 200 C, 8 C/min, 300 C (5 min) for pesticides Twister desorption (SBSE). TDS 2 splitless, 20 C, 60 C/min, 250 C (5 min) PTV solvent vent (50 ml/min), split ratio 20:1-120 C (0.2 min), 12 C/s, 280 C (3 min) MPS 2 / SPME Fibers 100µm PDMS Equilibration 60 C (10 min) Extraction 60 C (10 min) PTV 0.8 min splitless isothermal at 250 C Sample Preparation. Grapefruit juice. 0.1 ml of undiluted sample was transferred to a 20 ml headspace vial (SPME). Orange juice. 10 ml of undiluted orange juice was transferred to a 10ml headspace vial. The sample was AN/2003/07-2

spiked with 10 ug/l (Restek #32032 Pesticide Evaluation Mix). A Twister was added and the sample stirred at room temperature for 90 minutes. After extraction the Twister was removed, rinsed, dried and placed into a thermal desorption tube for analysis (SBSE). Retention Time Locking. Identification of the flavors and pesticides was performed automatically using the Agilent Screener software in combination with the Agilent Retention Time Locking (RTL) library for flavors. For comparison purposes, mass spectral identifications were carried out using the Wiley 138 mass spectral library. The locking compound used for the flavors was hexadecane, the inlet pressure was adjusted to give a retention time of 31.535 minutes. The locking compound used for the pesticides was Aldrin, the inlet pressure was adjusted to give a retention time of 18.530 minutes. Hexadecane is part of the 400 compounds included in the flavor RTL database with an elution time of 31.535 minutes. Our system (Figure 1) included a programmable temperature vaporizer (PTV) inlet that includes a septumless head injector (CIS 4, Gerstel). The GERS- TEL septumless head (SLH) on the CIS 4 eliminates the problem of inlet septum coring common to most inlets used with the blunt-tipped SPME needles. After some preliminary runs, the method was locked and 5 runs were automatically created using Agilent s ChemStation data acquisition software (version DA.00.01, Agilent Technologies). Figure 2 shows the 5 runs used for locking the flavor method. The RTL algorithm creates an RTL curve using the inlet pressure and the locking compound retention time. In this study, the measured retention time was 31.587 minutes and the locked retention time with a constant pressure of 10.42 psi was 31.535 minutes (obtained from the RTL database). RESULTS AND DISCUSSION The experimental conditions used in this study are similar to the ones used by David et al [1]. In their study, they replicated the parameters used by Adams [2] in which he publishes retention indices databases useful in the flavor industry. Since all the experimental conditions are the same, the spectra and retention data are valid for all studies. In order to use the RTL flavor database, we decided to use hexadecane to lock our GC/MS method. 32.302 Time--> 10.00 20.00 30.00 31.937 Time--> 10.00 20.00 30.00 31.587 Time--> 10.00 20.00 30.00 31.251 Time--> 10.00 20.00 30.00 30.929 Figure 1. GC/MS system used in the study. SPME autosampler coupled with a septumless head in the front injector and Thermal Desorption Autosampler coupled with a PTV injector in the back injector. Time--> 10.00 20.00 30.00 Figure 2. Retention time locking setup using hexadecane as the locking compound. The 5 individual runs were created automatically by using the Agilent s RTL method acquisition software. AN/2003/07-3

We decided to examine a grapefruit juice sample (purchased at a local store) using solid phase microextraction. Figure 3 shows the TIC obtained after sampling the grapefruit juice headspace with a PDMS SMPE fiber. Table 1 shows the identities obtained for some compounds using Wiley 138 mass spectral database and the flavor RTL database. 3000000 6 000 Time--> 1 2 3 4 5 7 8 9 10 10.00 20.00 30.00 Figure 3. Total ion chromatogram obtained after sampling the headspace above 100 ul of grapefruit juice with a SPME fiber using an automated sampler. Data was acquired under locked conditions using hexadecane as the locking compound. Table 1. Identification of some compounds by sampling grapefruit juice with SPME fiber. If more than one match was found with the Wiley library with a quality match of over 90% an * was placed beside the match. Peak # Compound Wiley RTL Screener 1 α-pinene X * X 2 Myrcene X X 3 δ-3-carene X * X 4 Cymene X * X 5 Linalool X * X 6 α-terpineol X X 7 cis-geraniol X * X 8 Carvone X * X 9 Geraniol X * X 10 Valencene X * X Inspection of Table 1 indicates that the additional information obtained while running the juice sample under locked conditions is complementing the mass spectral information. For example, α-pinene was easily identified using the RTL database while the Wiley database gave three matches all with match qualities of over 90%. Figure 4 shows the library matches for the peak eluting at 5.14 minutes in the grapefruit juice. It can be seen in this figure that the mass spectra profiles are very similar for all the possible matches. In this particular case, the information provided by using the RTL screener clearly identifies the peak eluting at 5.14 minutes as α-pinene. AN/2003/07-4

7000 93 A 8000 #8160:.alpha.-Pinene, (-)- CAS# 80-56-8 MQ 94 93 B 5000 3000 77 1000 105 121 136 77 105 121 136 m/z--> 40 60 80 100 120 140 8000 93 #8161: Bicyclo[3.1.1]hept-2-ene, 3,6,6-trimethyl- CAS# 4889-83-2 MQ 94 C m/z--> 40 60 80 100 120 8000 #8096:.gamma.-Terpinene CAS# 99-85-4 MQ 90 93 D 77 105 121 136 77 105 121 136 m/z--> 80 100 120 m/z--> 40 60 80 100 120 Figure 4. Possible library matches using Wiley 138 for peak eluting at 5.14 minutes from TIC of Figure 3. A) Scan of peak eluting at 5.14 min in grapefruit juice; B) Wiley 138 library match #1; C) Wiley 138 library match #2; D) Wiley library match #3. [Note: By using the RTL database, it was concluded that the peak eluting at 5.14 min was α-pinene (spectrum displayed in B)] We also decided to inspect the pesticide RTL database [3] using a GC/MS method. For this example, we inspected an orange juice sample spiked with pesticides. As seen in Figure 5, the combination of stir bar sorptive extraction (SBSE) coupled with a PTV and thermal desorption system can provide a complex totalion-chromatogram profile. It can also be seen in this figure that even at 10 ppb levels the pesticides were detected and screened with the RTL pesticide database (Figure 6). AN/2003/07-5

000 3000000 000 Time--> 10.00 1 3 2 20.00 30.00 Figure 5. Total ion chromatogram obtained after sampling spiked-orange juice with SBSE. The pesticides were spiked at 10 ppb levels. Peak identities are 1) Aldrin; 2) Endrin; 3) p,p DDT. 8000 Ion 263.00 (262.70 to 263.70) Ion 66.00 (65.70 to 66.70) Ion 265.00 (264.70 to 265.70) Ion 261.00 (260.70 to 261.70) 18.50 Time--> 17.50 18.00 18.50 19.00 19.50 66 263 (265) Aldrin 18.495min (-0.033) 91 response 22047 Ion Exp% Act% 220 293 329 263.00 100 100 66.00 86.70 97.02 265.00 66.70 67.44 261.00 64.40 69.12 m/z--> 100 200 300 Figure 6. Identification of Aldrin by the RTL screener in spiked orange juice. AN/2003/07-6

CONCLUSIONS By using enrichment techniques such as SPME and/or SBSE flavor constituents were easily detected using a GC/MS. Also, the use of an RTL method added meaningful retention time information supporting analytes identification. The use of automated SPME or SBSE is compatible with RTL databases and does not adversely affect the ability to lock methods. The overall result of the combination of hardware and software created a powerful tool in screening flavor compounds quickly and accurately. REFERENCES [1] David, F. et al. Analysis of Essential Oil Compounds Using Retention Time Locked Methods and Retention Time Databases. Agilent Application Note 5988-6530 EN, May 2002. [2] Adams, R. P. Identification of Essential Oil Components by Gas Chromatography-Mass Spectrometry; Allured Publishing Corporation: Illinois, 1995. [3] Sandra, P et al. J. Chromatogr. A. 1000 (2003) 299-309. AN/2003/07-7

G L O B A L A N A L Y T I C A L S O L U T I O N S Aktienstra e 232-234 D-45473 M lheim an der Ruhr +49 (0) 208-7 65 03-0 +49 (0) 208-7 65 03-33 gerstel@gerstel.de www.gerstel.de www.gerstel.com GERSTEL, Inc. Caton Research Center 1510 Caton Center Drive, Suite H Baltimore, MD 21227, USA +1 (410) 247 5885 +1 (410) 247 5887 info@gerstelus.com www.gerstelus.com Technisches B ro Berlin Marburger Stra e 2 D-10789 Berlin (0 30) 21 90 98 28 (0 30) 21 90 98 27 tb_berlin@gerstel.de Technisches B ro Bremen Parkallee 117 D-28209 Bremen GERSTEL AG Enterprise Surentalstrasse 10 CH-6210 Sursee +41 (41) 9 21 97 23 +41 (41) 9 21 97 25 gerstel@ch.gerstel.com www.gerstel.de (04 21) 3 47 56 24 (04 21) 3 47 56 42 tb_bremen@gerstel.de Technisches B ro Karlsruhe Greschbachstra e 6a D-76229 Karlsruhe (07 21) 9 63 92 10 (07 21) 9 6392 22 tb_karlsruhe@gerstel.de Technisches B ro M nchen Stefan-George-Ring 29 D-81929 M nchen (0 89) 93 08 65 14 (0 89) 93 08 61 09 tb_muenchen@gerstel.de GERSTEL, GRAPHPACK und TWISTER sind eingetragene Warenzeichen der. GERSTEL, GRAPHPACK and TWISTER are registered tradenames of Printed in the Fed. Rep. of Germany ' Copyright by