Development and Validation of Stability-Indicating RP-HPLC Method for Estimation of Atovaquone

Similar documents
Impact factor: 3.958/ICV: 4.10 ISSN:

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

Stability-indicating HPLC determination of tolterodine tartrate in pharmaceutical dosage form

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

A Simple, Novel Validated Stability Indicating RP-HPLC method for estimation of Duloxetine HCl in Capsule Pharmaceutical Formulation

Volume 6, Issue 2, January February 2011; Article-015

Praveen kumar.m 1 *, Sreeramulu.J 2. *Corres.author: Mobile no: India.

Development and Validation of Stability Indicating RP-HPLC Method for the Determination of Anagrelide HCl in Pharmaceutical Formulation

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form

International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

Validation of Stability-Indicating RP-HPLC Method for the Assay of Ibrutinib in Pharmaceutical Dosage form

Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form

Int. J. Pharm. Sci. Rev. Res., 30(2), January February 2015; Article No. 09, Pages: 63-68

Scholars Research Library

Method Development and Validation Of Prasugrel Tablets By RP- HPLC

Sravani and Haritha Indian Journal of Research in Pharmacy and Biotechnology ISSN: (Print) ISSN: (Online)

Development of Validated Analytical Method of Mefenamic Acid in an Emulgel (Topical Formulation)

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

INDICATING LIQUID CHROMATOGRAPHIC METHOD FOR QUANTIFICATION OF CIPROFLOXACIN HCL, ITS RELEATED SUBSTANCE AND TINIDAZOLE IN TABLET DOSAGE FORM

J Pharm Sci Bioscientific Res (4): ISSN NO

DEVELOPMENT AND VALIDATION OF A STABILITY-INDICATING RP-HPLC METHOD FOR ASSAY OF IRBESARTAN IN PURE AND PHARMACEUTICAL DOSAGE FORM

Development and validation a RP-HPLC method: Application for the quantitative determination of quetiapine fumarate from marketed bulk tablets

Journal of Drug Delivery and Therapeutics

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

International Research Journal of Pharmaceutical and Applied Sciences Available online at Int. Res J Pharm. App Sci.

International Journal of Pharmaceutical Research & Analysis

Development and validation of RP-LC method for lisinopril dihydrate in bulk and its pharmaceutical formulations

Saudi Journal of Medical and Pharmaceutical Sciences

Department of Quality Assurance, Luqman College of Pharmacy, GULBARGA (K.S.) INDIA ABSTRACT

LC Determination of Deferasirox in Pharmaceutical Formulation

Journal of Advanced Scientific Research DEVELOPMENT AND VALIDATION OF STABILITY-INDICATING RP-HPLC METHOD FOR ESTIMATION OF DABIGATRAN ETEXILATE

Dissolution study and method validation of alprazolam by high performance liquid chromatography method in pharmaceutical dosage form

STABILITY INDICATING RP-HPLC METHOD FOR DETERMINATION OF EPROSARTAN IN PURE AND PHARMACEUTICAL FORMULATION

Analytical Method Development and Validation of Lafutidine in Tablet dosage form by RP-HPLC

ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF IVABRADINE HCL IN BULK AND FORMULATION

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

Method Development and Validation for the Estimation of Darunavir in Rat Plasma by RP-HPLC

Stability indicating RP-HPLC method for determination of azilsartan medoxomil in bulk and its dosage form

STABILITY INDICATING RP HPLC METHOD FOR ANALYSIS OF DORZOLAMIDE HCl IN THE BULK DRUG AND IT S PHARMACEUTICAL DOSAGE FORM

Chapter 4: Verification of compendial methods

Development and validation of stability indicating reverse phase high performance liquid chromatography method for Timolol Maleate

Pelagia Research Library

INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND LIFE SCIENCES

Development and Validation of a HPLC Method for Determination of Anastrozole in Tablet Dosage Form

METHOD DEVELOPMENT AND VALIDATION OF RALTEGRAVIR POTASSIUM AND RILPIVIRINE HCL BY HPLC AND HPTLC METHODS

Scholars Research Library. Rapid and sensitive RP-HPLC analytical method development and validation of Pioglitazone hydrochloride

DEVELOPMENT AND VALIDATION OF NEW RP-HPLC METHOD FOR THE DETERMINATION OF AFLOQUALONE IN HUMAN PLASMA AND FORMULATION

Analytical method development and validation of gabapentin in bulk and tablet dosage form by using UV spectroscopic method

Liquid Chromatography and Spectroscopic Method for Estimation of Sulphadoxine in Marketed Formulation

Development And Validation Of Rp-Hplc Method For Determination Of Velpatasvir In Bulk

Isocraticc Reverse Phase HPLC Method-Determination and Validation of Cilostazol

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

Research Article Available online at

Development and Validation of RP-HPLC Method for Acid Resistance and Assay of Esomeprazole Magnesium in Esomeprazole Magnesium Pellets

Chapter-4 EXPERIMENTAL WORK BY RP-HPLC

Impact factor: 3.958/ICV: 4.10 ISSN:

Simultaneous HPLC Determination of Methocarbamol, Paracetamol and Diclofenac Sodium

Stability Indicating RP-HPLC Method for Determination of Valsartan in Pure and Pharmaceutical Formulation

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF GABAPENTIN IN PURE AND PHARMACEUTICAL FORMULATIONS

INTERNATIONAL JOURNAL OF UNIVERSAL PHARMACY AND BIO SCIENCES

International Journal of Pharma and Bio Sciences

Determination of Fexofenadine Hydrochloride in Pharmaceutical Dosage Form By Reverse Phase High Performance Liquid Chromatography Method

PHARMA SCIENCE MONITOR

CHAPTER - IV. Acharya Nagarjuna University, Guntur 105

Impact factor: 3.958/ICV: 4.10 ISSN:

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD TO DETERMINE CINITAPRIDE HYDROGEN TARTARATE IN BULK AND PHARMACEUTICAL FORMULATION

INTERNATIONAL RESEARCH JOURNAL OF PHARMACY

Asian Journal of Research in Chemistry and Pharmaceutical Sciences Journal home page:

Simultaneous estimation and validation of bromhexine and cephalexin in bulk and pharmaceutical dosage form by RP-HPLC method

STABILITY INDICATING METHOD OF RELATED IMPURITIES IN VENLAFAXINE HYDROCHLORIDE SUSTAINED RELEASE TABLETS

Development and Validation of Sensitive RP-HPLC Method for the Estimation of Glibenclamide in Pure and Tablet Dosage Forms

SIMULTANEOUS RP HPLC DETERMINATION OF CAMYLOFIN DIHYDROCHLORIDE AND PARACETAMOL IN PHARMACEUTICAL PREPARATIONS.

Zero And First Order Derivative Spectrophotometric Methods For Determination Of Dronedarone In Pharmaceutical Formulation

WORLD JOURNAL OF PHARMACEUTICAL AND MEDICAL RESEARCH

DEVELOPMENT AND VALIDATION OF A RP-HPLC METHOD FOR DETERMINATION OF LOPINAVIR IN BULK AND PHARMACEUTICAL DOSAGE FORM

Pelagia Research Library

Asian Journal of Chemical and Pharmaceutical Research. Asian Journal of Chemical and Pharmaceutical Research

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 9(1), 35-42

KEYWORDS: Acetaminophen, Doxylamine succinate, Dextromethorphan hydrobromide.

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

In the present analytical project, an attempt has been made to develop a simple, economical and reliable liquid

Pharmacophore 2011, Vol. 2 (4), ISSN Pharmacophore. (An International Research Journal)

Sarojamma. M et al, JGTPS, 2015, Vol. 6(2):

Available online Research Article

International Journal of Pharma Research and Health Sciences. Available online at

AND VALIDATION FOR SIMULTENEOUS ESTIMATION OF AMBROXOL HYDROCHLORIDE AND DOXOFYLLINE IN PHARMACEUTICAL DOSAGES FORMS AND BULK DRUGS BY RP-HPLC METHOD

Pelagia Research Library

RP-HPLC Estimation of Trospium Chloride in Tablet Dosage Forms

Research Article. Figure 1. Chemical structure of doxofylline. Indonesian J. Pharm. Vol. 24 No. 1 : ISSN-p :

Development and Validation of Stability Indicating Assay Method of Etodolac by using UV-Visible Spectrophotometer

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Mashhour Ghanem 1 and Saleh Abu-Lafi 2 * ABSTRACT ARTICLE INFO

Method Development And Validation Of Ondansetron In Bulk And Pharmaceutical Dosage Form By Stability- Indicating RP-HPLC Method

Analytical method development and validation of carvedilol in bulk and tablet dosage form by using uv spectroscopic method as per ich guidelines

Quantitation of Sodium Bisulfite in Pharmaceutical Formulation by RP-HPLC

Simultaneous Determination of Paracetamol, Chlorzoxazone and Diclofenac Sodium in Tablet Dosage Form by High Performance Liquid Chromatography

Transcription:

Available online at www.ijpcr.com International Journal of Pharmaceutical and Clinical Research 2012; 4(4): 68-72 Research Article ISSN 0975 1556 Development and Validation of Stability-Indicating RP-HPLC Method for Estimation of Atovaquone *Viplava.K, Haritha Pavani.V Nimra College of Pharmacy, Nimra nagar, Ibrahimpatnam, Vijayawada-521456 ABSTRACT A rapid RP-HPLC method developed for determination of Atovaquone in API. Atovaquone was found to be degraded under different set of conditions as followed according to ICH guidelines and the degradants so formed along with Atovaquone are separated by using Thermo Hypersil BDS C 18, 250mm 4.6mm 5µm column using Buffer: Acetonitrile (20:80) as mobile phase, with a flow rate of 1.5ml/min with a detection wavelength of 283nm with a injection volume of 20µl. The method was validated for specificity, linearity, accuracy, robustness, and precision. The obtained results were indicating that the method is selective in analysis of Atovaquone in the presence of degradation products formed under various stress conditions. Key words: Atovaquone, RP-HPLC, stability-indicating, Validation. INTRODUCTION Atovaquone is chemically trans 2-[4-(4- chlorophenyl)cyclohexyl]-3-hydroxy-1,4 naphthalenedione and it is official in Indian pharmacopoeia. It is used to treat the Pneumocystis Pneumonia, toxoplasmosis and malaria. MATERIALS AND METHODS Chemicals and Reagents: Atovaquone was obtained as gift sample from Rainbow pharma training Lab, Hyderabad, Andhra Pradesh. We used HPLC grade acetonitrile, methanol, and water, AR grade ortho phosphoric acid. Instrumentation: A HPLC (Waters, 2996) with PDA detector and Hypersil BDS C 18 250mm 4.6mm 5µm column was used. The HPLC system was equipped with Empower2 software for data processing. All the weighting s were done on single pan balance (Sartorius). Chromatographic Conditions: The mobile phase containing Buffer: Acetonitrile (20:80) was found to resolve Atovaquone. Ortho phosphoric acid was used for ph adjustment of buffer to 3.15. The mobile phase was filtered through 0.45 nylon filter and then ultrasonicated for 30 min. The flow rate was set to1.5ml/min. The drug shows good absorbance at 283nm, which was selected as wavelength for further analysis. Buffer preparation: Accurately transfer 1000ml of distilled water into 1000ml beaker and adjust P H with ortho phosphoric acid to 3.15. Filter the solution through 0.45µm nylon filter. Preparation of Mobile Phase Filtered and degassed mixture of Buffer and Acetonitrile in the ratio of 20:80 v/v Preparation of diluent: HPLC grade methanol was used as diluent. Preparation of Standard solution: Accurately weighed and transferred about 50 mg of Atovaquone standard into a 100ml clean dry volumetric flask add 30 ml of diluent, sonicated for 15 minutes and made up to the mark with diluent (this is standard stock solution). Fig.1. Chemical structure of Atovaquone Author for correspondence: E-mail: viplava89@gmail.com

Table.1: System Suitability Data Parameter Atovaquone Tailing Factor 1.704 Theoretical Plates 14212 %RSD of Peak area 0.1 Table.2: Linearity Data Level Concentration (mg/ml) Peak Area 50% 0.050 2945051 75% 0.075 4400905 100% 0.100 5873198 125% 0.125 7334958 150% 0.150 8809979 Slope - 58655636 Intercept - 7254.6 Correlation Coefficient - 1.00 Transferred 5.0 ml of the above solution in to 25ml volumetric flask made up to the mark with diluent. Filter the solution through 0.45µm nylon filter. Preparation of Sample solution: 20 Tablets of Atovaquone were weighed and powdered in glass mortar. Transferred the powder equivalent to the 50mg of active ingredient into a 100ml of volumetric flask add 30ml of diluent sonicate for 15 minutes with intermittent shaking and made up to the mark with diluent (this is sample stock solution). Transferred 5.0 ml of the above solution in to 25ml volumetric flask made up to the mark with diluent. Filter the solution through 0.45µm nylon filter. Preparation of Placebo Solution: Accurately weighed and transferred about 75mg of placebo powder into a 100 ml volumetric flask add 60 ml of diluent sonicate for 15 minutes with intermittent shaking and made up to the mark with diluent. Transfer 5.0 ml of the resulting solution into a 50 ml volumetric flask and made up to the mark with diluent. Filter the solution through 0.45 µg nylon filter paper. Method Validation 1) System Suitability/System Precision: System Suitability was performed by injecting six replicate injections of standard solutions of Atovaquone at 100% level (100µg/ml) and expressed as %RSD of peak area. 2) Linearity: 1 Standard solutions of various conc. of about 80%-150% level were injected into the chromatograph and calibration curve was constructed by plotting peak area against concentration in µg/ml. 3) Specificity: To demonstrate that diluents and placebo are not interfering with analytic peak, solutions of blank, Atovaquone standard, sample and placebo were prepared individually and run the chromatogram. The peak purity of analyte peak should be not less than 0.999. 2 4) Precision: Precision was measured in terms of repeatability of application and measurement. Repeatability of standard application was carried out using six replicates of the standard injections. 5) Accuracy: 3 %Recovery studies were carried out at three different levels of 50%, 100% and 150% of standard solution (i.e. Atovaquone API spiked to the placebo) in triplicate in each level. 6) Robustness: The robustness 2,4 of the proposed method was determined by analysis of aliquots from homogenous lots by differing physical parameters like flow rate (±0.2ml/min), Buffer composition (±2%) which may differ but the responses were still within the specified limits. Forced Degradation Studies 5: Photo Stability: Expose about 1000mg of powder in photo stability for 1.2 million Lux hours. Weigh accurately this powder equivalent to 50mg of Atovaquone into a 100ml volumetric flask add 60ml of diluent and sonicate for 15 minutes with intermittent shaking and made up to the mark with diluent. Filter the solution through 0.45µ nylon filter. Acid Degradation: Weigh accurately about 50mg of up with methanol. Then add 10ml of 0.1N HCL and sonicate place it aside for 2-3hrs, then neutralize the solution with 10 ml of base and then transfer 5ml of the above solution into 25ml volumetric flask dilute with methanol and filter the solution through 0.45µ nylon filter. Base Degradation: Weigh accurately about 50mg of up with methanol. Then add 10 ml of 0.1N NaOH and sonicate place it aside for 2-3hrs, then neutralize the solution with 10ml of acid and then transfer 5ml of the above solution into 25ml volumetric flask dilute with methanol and filter the solution through 0.45µ nylon filter. Peroxide Degradation: Weigh accurately about 50mg of up with methanol. Then add 0.1 ml of 10% H 2 O 2 and sonicate place it aside for 2-3hrs, then neutralize and then transfer 5ml of the above solution into 25ml volumetric flask dilute with methanol and filter the solution through 0.45µ nylon filter. Page69

Fig 2: Linearity plot for Atovaquone Viplava.K, Haritha Pavani.V/ Development and validation The chromatograms for specificity were shown in Fig.3, 4 and 5. Fig.3.Standard chromatogram Fig.4. Sample chromatogram Fig.5.Blank chromatogram RESULTS AND DISCUSSION Optimization of the mobile phase was based on asymmetric factor and peak area obtained for Atovaquone. The Mobile phase Acetonitrile: Buffer (80:20) was found to be satisfactory and gave symmetric peak for Atovaquone. Results were summarized in Table.no.1. The correlation coefficient was found to be 1.0 and results were summarized in Table.2. Precision was determined and the results are represented in the form of %RSD for assay and results were given in Table-3. The percentage mean recovery was found as 99.32%. The results were summarized in Table.4. As part of the robustness study deliberate changes in the flow rate and buffer composition was made to the impact on the method. Retention time was significantly changed Page70

Table.3: Repeatability Data Injection No. %Assay 1 98% 2 98% 3 98% 4 100% 5 99% 6 99% Mean 98 %RSD 0.87 Table.4: Accuracy Data Drug %Level Amount added Amount found (mg) (mg) Mean %Recovery %RSD 50% 0.059 0.059 100% 1.1 Atovaquone 100% 0.113 0.111 99% 0.1 150% 0.164 0.160 98% 0.9 Fig.6: Acid Stress condition Fig.7: Base stress condition Fig.8: Peroxide stress condition Fig.9: Thermal stress condition Table.5: Robustness Data Parameter RT of Atovaquone Actual 4.919 High Flow Rate : 1.7ml/min 3.893 Low Flow Rate : 1.3ml/min 5.080 High Temperature : 50 0 c 4.346 Low Temperature : 40 0 c 4.436 Page71

Table.6. Forced Degradation Data Treated Parameter RT Peak Purity Index As Such 4.919 1.0000 Photo Stability 4.992 1.0000 Acid Heat Treatment 4.119 1.0000 Base After Heat 4.411 1.0000 Oxidative Treatment After Heat 4.411 1.0000 but within the acceptance limit and results given intables.5. Result for Force Degradation Studies: The study showed that slight degradation observed when treated with acid, base, peroxide after heating and photo stability conditions. The peak purity index for known impurity and drug was found to be within acceptance criteria.i.e. Less than 0.990 and results were given intables.6 and the chromatograms for forced degradation were shown in Fig.6, 7, 8 and 9. CONCLUSION It can be concluded that the proposed RP-HPLC method is accurate, precise, sensitive, specific, robust and reproducible for the analysis of Atovaquone with less tailing and is also economical. REFERENCES 1. ICH QIA (R2). Stability Testing of New Drug Substances and Products. 2003 2. Snyder LR, Kirkland JJ, Glajch JI. Practical HPLC Method Development. 2nd ed.; 1997. 3. ICH, Q2B.Validation of Analytical Procedure: Methodology. International Conference on Harmonization, IFPMA, Geneva, 2005. 4. Validation of Analytical Procedure: Methodology, ICH Harmonized Tripartite Guidelines. 1996. p. 1-8. 5. ICH, 1994. Text on validation of analytical procedures, Q2A, International Conference on Harmonization, IFPMA, Geneva. Harmonization, IFPMA, Geneva. 6. Kalpesh N patel*, Jayvadhan K patel, Manish P patel, Ganesh C Rajput, A validated method for development of Atovaquone as API and tablet dosage forms by UV spectroscopy, Pharmaceutical methods vol-1,issue-1,2010,pg: 61-64 7. Lindegardh.N *, Bergqvist.Y, Automated solid phase extraction method for determination of Atovaquone in plasma and whole blood by rapid High- performance liquid chromatography, Journal of chromatography B Biomedical sciences and application vol 744 No.1,Pg: 9-17. 8. Chou.C.C *, Brown M.P, Merritt.K.A, Capillary zone electrophoresis for the determination of Atovaquone in serum, Journal of chromatography B Biomedical sciences and application vol 742,Issue-2,june 2000, pg: 441-445. 9. Suraj sahoo *, prasanna kumar panda, sagar kumar mishra, sabuj sahoo, HPLC method development for simultaneous estimation of Atovaquone and Proguanil in tablet dosage form, International Journal of pharmacy and Pharmaceutical Sciences vol-4/suppl-3, 2012. 10. Satish gangaram pingale *, ketan K nerukar, Ajit M padgankar, Uttam D pawar, Kiran V Mangaonkar, Determination of Atovaquone in Human plasma by LC-MS-MS and its application to a Bioequivalence study, Chromatographia vol-70/ 2009; pg: 947-951 11. N.Lindegardh *, D.Blessborn, Y.Berqvist, Simulataneous Quantitation of the Highly Lipophillic Atovaquone and Hydrophillic strong Basic proguanil and its metabolites using a new mixed-mode SPE approach and steep-gradient LC, Journal of chromatographic sciences vol-43,may/ june 2005. Page72