Influence of Tube Arrangement on the Thermal Performance of Indirect Water Bath Heaters

Similar documents
Numerical Study of Free Convection Heat Transfer in a Square Cavity with a Fin Attached to Its Cold Wall

A Numerical Study of Forced Convection Heat Transfer for Staggered Tube Banks in Cross-Flow

Natural Convection from a Long Horizontal Cylinder

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

PHYSICAL MECHANISM OF NATURAL CONVECTION

Numerical Analysis of Laminar Natural Convection in a Quadrantal Cavity with a Solid Adiabatic Fin Attached to the Hot Vertical Wall

UNIT II CONVECTION HEAT TRANSFER

Heat Transfer F12-ENG Lab #4 Forced convection School of Engineering, UC Merced.

Analysis of the flow and heat transfer characteristics for MHD free convection in an enclosure with a heated obstacle

FINITE ELEMENT ANALYSIS OF MIXED CONVECTION HEAT TRANSFER ENHANCEMENT OF A HEATED SQUARE HOLLOW CYLINDER IN A LID-DRIVEN RECTANGULAR ENCLOSURE

SELF-SUSTAINED OSCILLATIONS AND BIFURCATIONS OF MIXED CONVECTION IN A MULTIPLE VENTILATED ENCLOSURE

Natural convection heat transfer around a horizontal circular cylinder near an isothermal vertical wall

Analysis of Heat Transfer in Pipe with Twisted Tape Inserts

NATURAL CONVECTION FLOW IN A SQUARE CAVITY WITH INTERNAL HEAT GENERATION AND A FLUSH MOUNTED HEATER ON A SIDE WALL

Effect of Static Magnetic Field Application on the Mass Transfer in Sequence Slab Continuous Casting Process

A NUMERICAL STUDY ON THE FLOW AND HEAT TRANSFER FOR THE INSIDE OF A NEW DIVERSION-TYPE LNG HEATING DEVICE

Natural Convection from Horizontal Rectangular Fin Arrays within Perforated Chassis

Maximum Heat Transfer Density From Finned Tubes Cooled By Natural Convection

Effect of an adiabatic fin on natural convection heat transfer in a triangular enclosure

Available online at ScienceDirect. Procedia Engineering 90 (2014 )

Numerical Investigation on Turbulent Forced Convection in Heating Channel Inserted with Discrete V-Shaped Baffles

Natural Convection in Parabolic Enclosure Heated from Below

Sigma J Eng & Nat Sci 36 (1), 2018, Sigma Journal of Engineering and Natural Sciences Sigma Mühendislik ve Fen Bilimleri Dergisi

NATURAL CONVECTION HEAT TRANSFER IN PARTIALLY OPEN ENCLOSURES CONTAINING AN INTERNAL LOCAL HEAT SOURCE

NATURAL CONVECTION HEAT AND MOMENTUM TRANSFER IN SQUARE CAVITIES DISCRETELY HEATED FROM BELOW AND COOLED FROM ABOVE AND ONE SIDE

ENERGY PERFORMANCE IMPROVEMENT, FLOW BEHAVIOR AND HEAT TRANSFER INVESTIGATION IN A CIRCULAR TUBE WITH V-DOWNSTREAM DISCRETE BAFFLES

CFD ANALYSIS OF TRIANGULAR ABSORBER TUBE OF A SOLAR FLAT PLATE COLLECTOR

In order to optimize the shell and coil heat exchanger design using the model presented in Chapter

NUMERICAL SIMULATION OF THERMAL CONVECTION IN A CLOSED CAVITY IN THE PRESENCE OF A THIN HORIZONTAL HEATED PLATE

Numerical Investigation of Thermal Performance in Cross Flow Around Square Array of Circular Cylinders

THE EFFECTS OF LONGITUDINAL RIBS ON ENTROPY GENERATION FOR LAMINAR FORCED CONVECTION IN A MICROCHANNEL

Heat and Mass Transfer over Cooled Horizontal Tubes 333 x-component of the velocity: y2 u = g sin x y : (4) r 2 The y-component of the velocity eld is

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF A V-RIB WITH GAP ROUGHENED SOLAR AIR HEATER

Entropy 2011, 13, ; doi: /e OPEN ACCESS. Entropy Generation at Natural Convection in an Inclined Rectangular Cavity

LAMINAR FORCED CONVECTION HEAT TRANSFER IN HELICAL COILED TUBE HEAT EXCHANGERS

Cooling by Free Convection at High Rayleigh Number of Cylinders Positioned Above a Plane

Convection Heat Transfer. Introduction

The Effect Of MHD On Laminar Mixed Convection Of Newtonian Fluid Between Vertical Parallel Plates Channel

NATURAL CONVECTION AND RADIATION IN CIRCULAR AND ARC CAVITY

Introduction to Heat and Mass Transfer. Week 14

Numerical investigation of the buoyancy-induced flow field and heat transfer inside solar chimneys

Numerical Study of the Moving Boundary Problem During Melting Process in a Rectangular Cavity Heated from Below

CHME 302 CHEMICAL ENGINEERING LABOATORY-I EXPERIMENT 302-V FREE AND FORCED CONVECTION

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

Convection. forced convection when the flow is caused by external means, such as by a fan, a pump, or atmospheric winds.

Numerical analysis of fluid flow and heat transfer in 2D sinusoidal wavy channel

Entropy ISSN

Laminar natural convection in inclined open shallow cavities

Studies on flow through and around a porous permeable sphere: II. Heat Transfer

3D CFD ANALYSIS OF HEAT TRANSFER IN A SCRAPED SURFACE HEAT EXCHANGER FOR BINGHAM FLUIDS

Second Law Analysis of Forced Convective Cooling in a Channel with a Heated Wall Mounted Obstacle

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

NUMERICAL STUDY OF HEAT TRANSFER IN A FLAT PLAT THERMAL SOLAR COLLECTOR WITH PARTITIONS ATTACHED TO ITS GLAZING. Adel LAARABA.

Joule Heating Effect on the Coupling of Conduction with Magnetohydrodynamic Free Convection Flow from a Vertical Flat Plate

A STUDY ON NATURAL CONVECTION HEAT TRANSFER IN COMPLEX BOUNDARIES

Numerical Study for Free Convection Heat Transfer inside an Inclined Cavity with Cylindrical Obstacles

COMBINED EFFECTS OF RADIATION AND JOULE HEATING WITH VISCOUS DISSIPATION ON MAGNETOHYDRODYNAMIC FREE CONVECTION FLOW AROUND A SPHERE

NUMERICAL ANALYSIS OF MIXED CONVECTION CHARACTERISTICS INSIDE A VENTILATED CAVITY INCLUDING THE EFFECTS OF NANOPARTICLE SUSPENSIONS

EFFECT OF THE INLET OPENING ON MIXED CONVECTION INSIDE A 3-D VENTILATED CAVITY

MIXED CONVECTION HEAT TRANSFER FROM A PARTICLE IN SUPERCRITICAL WATER

Natural Convection in Vertical Channels with Porous Media and Adiabatic Extensions

Analysis of a Fluid Behavior in a Rectangular Enclosure under the Effect of Magnetic Field

FLOW SIMULATION AND HEAT TRANSFER ANALYSIS USING COMPUTATIONAL FLUID DYNAMICS (CFD)

MIXED CONVECTION IN A SQUARE CAVITY WITH A HEAT-CONDUCTING HORIZONTAL SQUARE CYLINDER

Convective Heat Transfer and Thermal Performance in a Circular Tube Heat Exchanger Inserted with U-Shaped Baffle

INFLUENCE OF VARIABLE PERMEABILITY ON FREE CONVECTION OVER VERTICAL FLAT PLATE EMBEDDED IN A POROUS MEDIUM

Effect of tube pitch on heat transfer in shell-and-tube heat exchangers new simulation software

Investigation of Shroud Geometry to Passively Improve Heat Transfer in a Solar Thermal Storage Tank

Numerical Analysis of a Helical Coiled Heat Exchanger using CFD

The Effect of Undulated Wall on Natural Convection Heat Transfer in Vertical Channels

ELEC9712 High Voltage Systems. 1.2 Heat transfer from electrical equipment

Analysis of Natural Convection Flow in a Trapezoidal Cavity Containing a Rectangular Heated Body in Presence of External Oriented Magnetic Field

FREE CONVECTION LIMIT TO HEAT TRANSFER FROM HEAT SINKS WITH SQUARE FINS ON A HORIZONTAL BASE Comparison with Cylindrical Fins

Effect of Buoyancy Force on the Flow Field in a Square Cavity with Heated from Below

Heat Transfer Convection

FREE CONVECTIVE HEAT TRANSFER FROM AN OBJECT AT LOW RAYLEIGH NUMBER

Meysam ATASHAFROOZ, Seyyed Abdolreza GANDJALIKHAN NASSAB, and Amir Babak ANSARI

EFFECTS OF CIRCULAR CORNERS AND ASPECT-RATIO ON ENTROPY GENERATION DUE TO NATURAL CONVECTION OF NANOFLUID FLOWS IN RECTANGULAR CAVITIES

PHYSICAL MECHANISM OF CONVECTION

A Finite Element Analysis on MHD Free Convection Flow in Open Square Cavity Containing Heated Circular Cylinder

Natural Convection and Entropy Generation in a Porous Enclosure with Sinusoidal Temperature Variation on the Side Walls

On the influence of tube row number for mixed convection around micro tubes

LAMINAR NATURAL CONVECTION IN VERTICAL 2D GLAZING CAVITIES

CFD MODELLING OF A SUBSEA COOLER FOR CALCULATION OF EXTERNAL HEAT TRANSFER COEFFICIENT

ENGR Heat Transfer II

Analysis of the Cooling Design in Electrical Transformer

A Numerical Study of Laminar Natural Convection Heat Transfer and Radiation from a Rectangular Vertical Fin Array Quasi-3D approach

LAMINAR NATURAL CONVECTION HEAT TRANSFER FROM AN ISOTHERMAL VERTICAL RIBBED PLATE

NATURAL CONVECTIVE HEAT TRANSFER FROM A RECESSED NARROW VERTICAL FLAT PLATE WITH A UNIFORM HEAT FLUX AT THE SURFACE

Characteristics of forced convection heat transfer in vertical internally finned tube B

FALLING FILM FLOW ALONG VERTICAL PLATE WITH TEMPERATURE DEPENDENT PROPERTIES

Heat and Mass Transfer Unit-1 Conduction

FREE CONVECTION OF A NANOFLUID IN A SQUARE CAVITY WITH A HEAT SOURCE ON THE BOTTOM WALL AND PARTIALLY COOLED FROM SIDES

Combined Natural Convection and Thermal Radiation in an Inclined Cubical Cavity with a Rectangular Pins Attached to Its Active Wall

A numerical study of heat transfer and fluid flow over an in-line tube bank

NATURAL CONVECTION OF AIR IN TILTED SQUARE CAVITIES WITH DIFFERENTIALLY HEATED OPPOSITE WALLS

Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct

Flow and Heat Transfer Profiles in a Square Channel with 45 V-Downstream Orifices

Heat Transfer Characteristics of Square Micro Pin Fins under Natural Convection

ENTROPY GENERATION DUE TO EXTERNAL FLUID FLOW AND HEAT TRANSFER FROM A CYLINDER BETWEEN PARALLEL PLANES

Transcription:

Journal of Chemical and Petroleum Engineering, University of Tehran, Vol. 47, No.2, Dec. 2013, PP. 69-81 69 Influence of Tube Arrangement on the Thermal Performance of Indirect Water Bath Heaters Esmaeil Ashouri *1, Farzad Veisy 1, Maryam Asadi 2, Hedayat Azizpour 3 and Afsaneh Sadr 3 1 Mechanical Engineering Department, Razi University, Kermanshah, Iran 2 Department of Physics, Arak University, Arak, Iran 3 School of Chemical Engineering, College of Engineering, University of Tehran, Tehran, Iran (Received 12 June 2013, Accepted 23 July 2013) Abstract Natural convection heat transfer from a tube bundle in the indirect water bath heaters is investigated. A computer-code is used for the solution of the governing equations of mass, momentum and energy transfer based on the SIMPLE-C algorithm. Simulations are carried out for the gas pressure station heater of Kermanshah city with various tube bundle arrangements. In order to validate the numerical code, results of the simulation compared with experimental data which measured from this heater. Effects of the tube bundle arrangement on heat transfer are presented. It is observed that changing the tube bundle arrangement (horizontal and vertical pitch) can affect the rate of heat transfer. In other word it can lead to increase the thermal performance of the indirect water bath heater. Finally, based on this framework it is suggested that the optimum arrangement of tube bundle can lead to the maximum heat transfer. Hence the performance enhances to 5.27%. Keywords: Tube arrangement, Natural convection, Indirect water bath heater, City gas station, Heater performance Introduction Indirect water bath heaters have been used in the oil and gas production, gas processing and gas distribution industry. The high-pressure natural gas and oil stream heating are the most common applications of the indirect water bath heaters. As it can be seen in Figure 1, indirect heaters are comprised of three basic components: shell, fire tube and gas tubes. Natural convection heat is transferred from the fire tube to the bath fluid and from the bath to the gas tube bundle. Natural convection heat transfer from a tube bundle of horizontal cylinders has received much attention for different applications, some of which are heat exchangers in the refrigeration industry, the cooling electronic devices, space heating, etc. Many heat exchangers commonly use multiple rows of tubes while a cross flow of a fluid is passing through outside. It is studied that turbulent cross flow dramatically increase heat transfer efficiency in comparison with parallel flow for a same fluid velocity. One should note that the velocity distribution of the flow around a tube is not uniform. Depending on application and design criteria, there are many possible tube layouts in a tube bundle. Due to the wide engineering applications in heat exchangers and passive solar energy collectors, researching on natural convection from multiple cylinders has become a great concern in recent years comparing to the single horizontal cylinders which have been studied for several decades. Morgan [1], Churchill and Chu [2] and many other researchers have found empirical relations that focus on timeaveraged Nusselt number. Collis and William [3] proposed the following correlations in a single tube, for determining Nusselt numbers for a range of Rayleigh numbers between 10-10 - 10 10 in a single tube: * Corresponding author Tel.: +98-8612172612, Fax: +98-8612172669 Email: e.ashouri63@gmail.com

70 Journal of Chemical and Petroleum Engineering, University of Tehran, Vol. 47, No.2, Dec. 2013 Ra 10 10 10 2 2 10 10 2 4 10 10 4 7 10 10 7 10 10 10 2 Nu 0.058 0.675 Ra D 0.148 1.02 Ra D 0.188 0.85 Ra D 0.25 0.48Ra D 0.333 0.125Ra D (1) Free convection heat transfer from an array of two vertically separated cylinders, was studied by Sparrow and Neithammer [4]. They found a direct relation between average Nusselt and the space distance between two cylinders for a range of Rayleigh number from 2 10 4 to 2 10 5. They also showed that the maximum heat transfer occurs when the distance is between 7 to 9 diameter apart while wall temperature is assumed to be uniform. Tokura [5] worked on vertical arrays of 2, 3 and 5 horizontal cylinders at a uniform temperature and within a range of Rayleigh numbers from 2.8 10 4 to 2.8 10 5. Investigating heat transfer profile around a cylinder showed the space effect on their free convection heat transfer. These studies showed that the spacing between the cylinders has direct relation with the heat transfer at the bottom of upper cylinder. Based on some experimental studies on natural convection of two horizontal cylinders in air Chouikh [6], referred to a fact that at higher Rayleigh numbers (10 4 compared to 10 2 ), the most of the fluid flow through the sides rather than the bottom. Analysis of the effect of spacing and Rayleigh number on heat transfer by Lieberman and Gebhart [7] and Marsters [8] showed a different behavior of upper and lower cylinder while Yousefi and Ashjaee [9] studied natural convection from a vertically aligned array of horizontal elliptic cylinders. Marsters [8], Ashjaee and Yousefi [10] have also shown that spacing just influence on the heat transfer of upper cylinder while the lower ones act as single cylinders. Accordingly, Marsters [8] describes that the amount of heat transfer of the upper cylinder could be significantly less than that of the lower one for small spacing, while for large spacing the heat transfer could approximately increase by 30%. Lieberman and Gebhart [7] related this difference of heat transfer to lower cylinder plume rising by explaining two simultaneous effects with opposite results. The plume temperature is higher than that of the bulk fluid and this leads to the reduction of local temperature difference and consequently the surface heat transfer from the upper cylinder. On the other hand, the plume velocity increases heat transfer of the upper cylinder by imposing a forced convection flow condition. In this study, the influence of tube bundle arrangement on the global Nusselt number, heat transfer and thermal performance were investigated. The numerical solutions were performed for laminar flow that is performed by natural convention from fire tubes, placed in the lower part of heaters. Also the numerical code has been developed to calculate two-dimensional buoyancydriven convection in differential arrangements of tube bundle. As a first step and in order to validate the numerical code, heat transfer and Nusselt number are calculated for different rows of tube bundle arrangement for 150,000 SCMH indirect water bath gas heaters which is located in the gas pressure station of Kermanshah city. The calculated results are compared with those of the experimental that are measured from this heater and at international standard. In the second step, the amount of heat transfer of tube bundle for different arrangements were obtained and finally offered the optimum arrangement of tube bundle that can lead to a maximum heat transfer. 2. Theoretical approach 2.1. Mathematical model The flow of water through the tube bundle is simulated mathematically. For this purpose, a computer-code is used for the solution of the differential equations related

Influence of Tube Arrangement on.. to the conservationn of mass, momentum and energy. The viscous dissipation term in the energy equation is neglected. The Boussinesq approximation is applied for the properties of fluid to relate density to temperature, and hence to couple the fields of temperaturee to that of the flow..v=0 (2) 2 Ra g. V V p V T 0 Pr g (3) 1 2. V T T Pr (4) Where Ra is Rayleigh number thatt is defined as gβ(t W -T )D3/υα and is based on the cylinder-diameter; V is the velocity vector with dimensionless velocity components U and V and is normalized with υ/d; T is the dimensionless temperature that is normalized with temperature difference (T W -T ); P is the dimensionless pressure whichh is normalized with ρ υ 2 /d 2 ; g is the gravity vector and Pr=υ/α is the Prandtl number. Also ρ, β, υ, α and g are the fluid density, the volumetric expansion coefficient, the kinematic viscosity, the thermal diffusivity and the gravitational acceleration, respectively. The boundary conditions for the present study are later discussed. The temperature of tube bundle surface T w is assumed to be constant, at 24 C (that is the average value between outlet (38 C) and inlet gas temperature (10 C) according to indirect water bath gas heater 150,000 SCMH in the gas pressure station of Kermanshah city). The dimensions of the heater are shown in Figure 1. The shell is insulated and the temperature of the heater is maintained below the boiling point of water. The averagee temperature of water bath T is 60 C that is obtained from the gas pressure station of Kermanshah city. The temperature of the fire tubes is kept constant and the temperature of their surfacess is calculated by trial and errorr method. For this purpose, the temperature of these tubes 71 is first guessed, and then the temperature of water around them is calculated (see Table 1). According to the experimental values, the average of water temperature should be around of 60 C (this value elicited from present heater), so as much as the temperature of water bath is closer to this value, then the assumed temperaturee will be closer to the right value of the fire tubes. Finally based on the performed calculation (table 1), the surface temperature of the fire pipes was obtained to be 127 C (4000 K). Table 1: Fire tube temperature computed by trial and error method Assumed fire tube Average temperature temperaturee ( C) of water bath ( C) 75 40 100 55 127 61 227 92 327 100 427 147 Figure 1: Schematic diagram of indirect water bath heater

72 Journal of Chemical and Petroleum Engineering, University of Tehran, Vol. 47, No.2, Dec. 2013 2.2. Solution procedure The governing equations (2) (4) is solved with the boundary conditions, throughh a control-volumdifference method. Van Doormaal and formulation of the finite- Raithby[11] handled the pressure-velocity coupling by using the SIMPLE-C algorithm, which is essentially a further implicit variant of the SIMPLE algorithm by Patankar and Spalding[12]. Leonard [ 13] evaluated the convective fluxes across the surfacess by using the QUICK discretization scheme. Details on the SIMPLE procedure may be found in Patankar[14]. Both Polar and Cartesian grid regions discretized by using fine uniform mesh spacing. Starting from specified first approximation distributions of the dependent variables across the integration domain; iterative solution through a line-byalgorithfor line application of Thomas governing equations is done, while under- of the iterative procedure. The solution is relaxation is used to ensure the convergence assumed to be fully converged when the maximum absolute values of both mass source and percent variations of the dependent variables at any grid-node; are smaller than prescribed values, 10-3 and 10-5, respectively. By achieving convergence, the average Nusselt numbers Nu ij of any ij th cylinder in the tube bundle are calculated (i and j represent row and column number): Q ij Nu ij (5) k T T ( W ) Where Q ij is the heat flux. Tests on the dependence of the results acquired on the mesh-spacing of the Cartesian grids, as well as on the thickness and mesh-spacing of the polar grid regions around the gas tube and fire tube, and on the extension of the entire computational field, have been carried out for a wide range of geometrical configurations and Nusselt numbers. In particular, the optimal values of grid-size and the positions of the interface between polar and Cartesian grids; represent a good compromise between time required and computational accuracy for solution process. They are assumed as those over which more refinements or displacements do not create considerable modifications in both flow field and heat transfer rates. In order to validate the numerical code and the composite-grid discretization scheme specifically developed for the present study; the average Nusselt numbers obtained for a single cylinder at Rayleigh numbers 6.19 10 9 have been compared with the Eq (1). The computed values of Ra, using thermal conditions of the present heater were mentioned in the boundary conditions. The numerical result of the average Nusselt number is 232 and the corresponding calculated value is 229.5. (Nu-Nu eq q.1) 100/Nu eq.1 =1.08% In particular, it may be seen that the local results are well within 1% of the benchmark data. 3. Results and discussion 3.1. Heater with current arrangement tube bundle The general dimensionn of 1500000 SCMH heaters is shown in Figure 1. Gas tube arrangement of this heater is in such a way that S p /d=1.5, S n /d=1.75 (S p and S n are shown in Figure 2) and the length of each tube is 9 meter. The results obtained for this step is mentioned in table 2. Figure 2: Schematic diagram of Sp and Sn

Influence of Tube Arrangement on.. 73 Figure 3: Layout of velocity vector for current heater. Table 2: Results of modeling the indirect heater with present tube bundle arrangement. Nu for first row 328 Nu for 2th row 346 Nu for 3th row 315 Nu for 4th row 320 Heat flux (W/m 2 ) 30,076 Average water bath temperature (K) 333.5 Figure 3 shows the layout of velocity vectors for this heater and indicates how natural convection causes water to flow through the heater. The generated water plume flowing at the bottom of fire tube, try to flow through the upper part of the shell. The water flow impinges to the tube bundle and a major portion flows toward the surrounding of the shell and goes down with colder water to the center of shell. Also some portions of water go ahead inside the tube bundle. Section A, B, C and D (Figure 4 to 7) give more useful information about flow vectors around gas tubes in the different rows. These figures indicate that the directions of flow around each tube are much different than the other tubes. For example, section A (Figure 4) shows that the flow direction at the right side of the section is opposite of the other side. According to Table 1, maximum heat transfer occurs in the second row of the tube bundle, this can be interpreted by considering the section B (Figure 5). Natural convection plume from the fire tube, contact directly to these tubes and also the plume temperature is higher than the average of fluid temperature in the other rows. The flow going down the upper cylinder, contact the plume that is rising form the fire tubes and make vortex flow near this row, and hence increases the heat transfer. The overall heat flux from all tube bundle equals to 30,076 (W/m 2 ) which is a normal value for this type of heaters with given API SPECIFICATION 12K [15] (for Indirect Type Oilfield Heaters). Furthermore, basing on current dimensions of the heater, (9m length, 30 gas tubes, 114.3mm diameter) the total surface area becomes 96.9 m 2. Therefore, the amount of energy received by gas is equal to 2.914 MW. This energy leads to 30 degree increase in the gas temperature for 150,000 SCMH heaters. Thus, when the entrance temperature of gas equals to 10 degree centigrade, the outflow temperature will be 40 degree centigrade which is approximately equal to the outflow temperature mentioned at boundary conditions. These calculations demonstrate validity of numerical solution too.

74 Journal of Chemical and Petroleum Engineering, University of Tehran, Vol. 47, No.2, Dec. 2013 Figure 4: Velocity vector diagram for section A Figure 5: Velocity vector diagram for section B Figure 6: Velocity vector diagram for section C

Influence of Tube Arrangement on.. 75 Figure 7: Velocity vector diagram for section D 350 345 340 335 Nu 330 325 320 315 310 305 Sn/D =1.5 Sn/D =1.75 Sn/D =2 Sn/D =2.25 Sp/D =1.5 Sp/D =1.75 Sp/D =2 Sp/D =2.25 Figure 8: Nusselt number of first row

76 Journal of Chemical and Petroleum Engineering, University of Tehran, Vol. 47, No.2, Dec. 2013 365 355 345 Nu 335 325 315 305 Sn/D =1.5 Sn/D =1.75 Sn/D =2 Sn/D =2.25 Sp/D =1.5 Sp/D =1.75 Sp/D =2 Sp/D =2.25 Figure 9: Nusselt number of second row 365 355 345 Sn/D =1.5 Sn/D =1.75 Sn/D =2 Nu 335 325 Sn/D =2.25 315 305 Sp/D =1.5 Sp/D =1.75 Sp/D =2 Sp/D =2.25 Figure 10: Nusselt number of third row 3.2. Heater 150,000 SCMH with different tube bundle arrangements The numerical results obtained for the effects of tube bundle arrangement on the Nusselt number for different rows of this heater with average magnitude of heat transfer are expressed in table 3-8 and figure 8-13. These show the perpendicular pitch (S n /D) and longitudinal pitch (S p /D) to have great effects on the heat transfer. Results are summarized by as follows: It is clear from figures 12 and 13 that, an increase in S n /D leads to a decline in the Nusselt number and heat transfer. That is due to the nozzle effect between gas tubes. Increasing S n leads to a minimum flow area

Influence of Tube Arrangement on.. 77 increase. Therefore, the velocity of impingement flow on the upstream row of tubes drops and finally contributes a decrease in heat transfer. Similar researches done by Wilson and Khalil [16] also confirm these results. Table 3: Nusselt number of first row S n /D S p /D 1.5 1.75 2 2.25 1.5 339 342 346 343 1.75 328 333 336 334 2 322 325 333 329 2.25 318 322 325 324 Table 4: Nusselt number of second row S n /D S p /D 1.5 1.75 2 2.25 1.5 357 360 363 361 1.75 346 352 355 353 2 340 343 351 346 2.25 336 341 343 341 It could clearly be seen that when S P /D 2, any increase in S p leads to enhance the Nusselt numbers and heat transfer. This is because, an increase of S P /D gives the chance to the flow behind the last row, to approach the reattachment point and enhance heat transfer coefficient. On the other hand, any climb in S p /D leads to increase in the rate of entering flow through the rows (shown in section D Figure 7). Also, these flows are hotter than those inside the spacing of the tube bundle. This phenomenon causes an increase in the average of heat transfer. Further increase in S p /D (exceeding 2), leads to decline in Nu. This is because of the upstream row of the tubes, results from fom the flow separation of the last row. The comparison between the contour plots in Figures 14 and 15, shows the average fluid temperature surrounding the tube bundle in Figure 14 (with S n /D=1.5 and S P /D=2) is higher than the fluid temperature in Figure 15 (with S n /D=1.75 and S P /D=1.5). In addition, Figure 14 shows offering arrangement (S n /D=1.5 and S P /D=2) for tube bundle. The offering arrangement leads to improve the circuit of fluid and consequently contributes an increase in the heat transfer. The performance of these heaters calculated by the following equation: η=q out /Q in (6) Where Q out is the amount of energy that is absorbed by tube bundle and Q in is the energy that is partially entering into the heater and the remaining is absorbed by tube bundle. According to figure 13, the maximum heat transfer occurs at S n /D=1.5 and S P /D=2, using the equation (6) with consistent Q in. the increase of the heater performance equals to: (Q out2 -Q out1 ) 100/Q out1 =5.27 % Where Q out2 equals to the amount of heat transfer by the optimum arrangement of the tube bundle (S n /D=1.5 and S P /D=2) and Q out1 is the heat transfer by the present arrangement of the tube bundle. As it can be seen, we can improve the performance of theses heaters to 5.27% by using the optimum arrangement which is offered in this study. Table 5: Nusselt number of third row S n /D S p /D 1.5 1.75 2 2.25 1.5 326 328 333 330 1.75 315 320 323 321 2 309 312 319 315 2.25 306 309 312 310 Table 6: Nusselt number of fourth row S n /D S p /D 1.5 1.75 2 2.25 1.5 331 334 340 336 1.75 320 325 328 326 2 314 318 323 320 2.25 311 314 317 315

78 Journal of Chemical and Petroleum Engineering, University of Tehran, Vol. 47, No.2, Dec. 2013 Nu 365 355 345 335 325 Sn/D =1.5 Sn/D =1.75 Sn/D =2 Sn/D =2.25 315 305 Sp/D =1.5 Sp/D =1.75 Sp/D =2 Sp/D =2.25 Figure 11: Nusselt number of fourth row 365 355 345 Sn/D =1.5 Sn/D =1.75 Sn/D =2 Sn/D =2.25 Nu 335 325 315 305 Sp/D =1.5 Sp/D =1.75 Sp/D =2 Sp/D =2.25 Figure 12: Average Nusselt number for all tubes in the bundle for different arrangement Table 7: Average Nusselt number for all tubes in the bundle for different arrangements S n /D S p /D 1.5 1.75 2 2.25 1.5 338 341 345 342 1.75 327 332 335 333 2 322 324 331 329 2.25 319 321 324 322 Table 8: The amount of heat flux (W/m 2 ) obtained for different arrangements S n /D S p /D 1.5 1.75 2 2.25 1.5 31,025 31,344 31,663 31,463 1.75 30,076 30,515 30,746 30,620 2 29,576 29,760 30,400 30,200 2.25 29,280 29,520 29,740 29,600

Influence of Tube Arrangement on.. 79 32000 31000 Heat Flux (W/m 2 ) 30000 29000 28000 27000 26000 Sn/D =1.5 Sn/D =1.75 Sn/D =2 Sn/D =2.25 Sp/D =1.5 Sp/D =1.75 Sp/D =2 Sp/D =2.25 Figure 13: Calculated heat flux (W/m 2 ) for different arrangements Figure 14: Contour plots of the fluid temperature for optimum arrangement (S n /D=1.5 and S P /D=2) Figure 15: Contour plots of the fluid temperature for present arrangement (S n /D=1.75 and S P /D=1. 5)

80 Journal of Chemical and Petroleum Engineering, University of Tehran, Vol. 47, No.2, Dec. 2013 4. Conclusion Steady laminar natural convection from fire tube to tube bundle in an indirect water bath heater has been studied numerically through a developed computer-code based on the SIMPLE-C algorithm. Simulations have been performed for 14 different arrangements of tube bundle. The results were compared with current heater in the gas pressure station at Kermanshah city. It was observed that by using the optimum tube bundle arrangement (S n /D=1.5 and S P /D=2), the average heat transfer of is increased and consequently improve the performance by 5.27%. Nomenclature D Diameter of gas tube [m] g Acceleration due to gravity, [m/s 2 ] g Gravity vector Convective heat transfer h coefficient, [W/m 2 K] k Thermal conductivity, [W/mK] Nu Nusselt number, [-] Nu ij Tube Nusselt number for the i row and j column, [-] p Dimensionless pressure Pr Prandtl number, [-] Q Heat transfer rate [W/s.m 2 ] r Dimensionless radial coordinate Ra Rayleigh number, [-] S P Longitudinal pitch [m] S n Perpendicular pitch [m] Standard Cubic Meters per Hour SCMH [m 3 /h] T Temperature [K] Greek symbols Thermal diffusivity of the fluid α [m 2 /s] Temperature coefficient of volume β expansion, [K -1 ] Kinematic viscosity of the fluid υ [m 2 /s] θ Dimensionless polar coordinate [-] ρ Density, [kg/m 3 ] η Performance Subscripts in Inlet out Outlet w Referred to the tube surface Referred to the undisturbed fluid References: 1- Morgan, V.T. (1975). The overall convective heat transfer from a smooth cylinder. Adv. in Heat Transfer, 11, pp. 199-264. 2- Churchill, S.W. and Chu, H.H.S. (1975). Correlating equations for laminar and turbulent free convection from a horizontal cylinder. Int. J. Heat Mass Trans., 18(9), pp.1049-1053. 3- Collis, D.C. and Williams, M.J. (1954). Free convection of heat from fine wires. Aeronautical Research Laboratories, Melbourne, Australia, Note 140. 4- Sparrow, E.M. and Niethammer, J.E. (1981). Effect of vertical separation distance and cylinder-to-cylinder temperature imbalance on natural convection for a pair of horizontal cylinders. Int. J. Heat Transfer, 103(4), pp. 638-644. 5- Tokura, I., Saito, H., Kishinami, K. and Muramoto, K. (1983). An experimental study of free convection heat transfer from a horizontal cylinder in a vertical array set in free space between parallel walls. Int. J. Heat Transfer, 104, pp.102-107. 6- Chouikh, R., Guizani, A., Maalej, M. and Belghith, A. (2000). Experimental study of the natural convection flow around an array of heated horizontal cylinders. Renewable Energy, 21(1), pp. 65-78.

Influence of Tube Arrangement on.. 81 7- Lieberman, J. and Gebhart, B. (1969). Interactions in natural convection from an array of heated elements, experimental. Int. J. Heat Mass Trans, 12(11), pp. 1385-1396. 8- Marsters, G.F. (1972). Arrays of heated horizontal cylinders in natural convection. Int. J. Heat Mass Trans, 15(5), pp. 921-933. 9- Yousefi, T. and Ashjaee, M. (2007). Experimental study of natural convection heat transfer from vertical array of isothermal horizontal elliptic cylinders. Exp. Therm. Fluid Sci., 32, pp. 240-248. 10- Ashjaee, M. and Yousefi, T. (2007). Experimental study of free convection heat transfer from horizontal isothermal cylinders arranged in vertical and inclined arrays. Int. J. Heat Transfer Eng., 28(5), pp. 460-471. 11- Van Doormaal, J.P. and Raithby, G.D. (1984). Enhancements of the simple method for predicting incompressible fluid flows. Int. J. Heat Transfer, 11, pp. 147 163. 12- Patankar, S.V. and Spalding, D.B. (1972). A calculation procedure for heat, mass and momentum transfer in three-dimensional parabolic flows. Int. J. Heat Mass Transfer, 15, pp. 1787 1797. 13- Leonard, B.P. (1979). A stable and accurate convective modeling procedure based on quadratic upstream interpolation. Comput. Meth. Appl. Mech. Eng., 19, pp. 59 78. 14- Patanka, S.V. (1980). Numerical heat transfer and fluid flow. Hemisphere Publ. Co., Washington, DC. 15-American petroleum institute, (2008). API Specification 12K, Specification for Indirect Type Oilfield Heaters, eighth edition. 16- Wilson, A.S. and Bassiouny, M.K. (2000). Modeling of heat transfer for flow across tube banks. Int. J. Chem. Eng. Process., 39, 1-14.