An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Similar documents
Activity in the FID Detection Port: A Big Problem if Underestimated

Introduction and Principles of Gas Chromatography

Get Selective. By Jaap de Zeeuw

Chromatography. Gas Chromatography

Chapter 27: Gas Chromatography

Selection of a Capillary

Virtually Particle-Free Rt -Silica BOND Columns

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Selection of a Capillary GC Column

Understanding Gas Chromatography

Ultra-Inert chemistry for Trace Level Analysis

A New Web-Based Application for Modeling Gas Chromatographic Separations

CHAPTER 6 GAS CHROMATOGRAPHY

Trajan SGE GC Columns

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Gas Chromatography (GC)

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Gas Chromatography. Introduction

Volatile organic compounds (VOCs):

Method for Characterization of Gum Rosin by Capillary Gas Chromatography

Introduction to Capillary GC

Introduction to Gas Chromatography

Column Selection. there is more to life than a boiling point column. Jaap de Zeeuw Restek Corporation, The Netherlands. Copyrights: Restek Corporation

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

High Performance Liquid Chromatography

A New Web-Based Application for Modeling Gas Chromatographic Separations. Dr. Hansjoerg Majer Restek Corporation Market Development Manager Europe

Chapter 31 Gas Chromatography. Carrier Gas System

Supelco Ionic Liquid GC Columns Introduction to the Technology

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas


A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Industrial Applications with a New Polyethylene Glycol-Based GC Column

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010

Speakers. Moderator. John V Hinshaw GC Dept. Dean CHROMacademy. Tony Taylor Technical Director CHROMacademy. Dave Walsh Editor In Chief LCGC Magazine

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

GAS CHROMATOGRAPHY (GC)

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Study of Residual Solvents in Various Matrices by Static Headspace

Secrets of GC Column Dimensions

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Highly Sensitive and Rugged GC/MS/MS Tool

Principles of Gas- Chromatography (GC)

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

Gas Chromatography. Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid

Lab 3 Guide: Gas Chromatography (GC) (Sept 8-14)

Continuous Improvement in Petroleum/Petrochemical Analysis HP s Family of Innovative PLOT Columns

How To Select the Correct GC Column. Simon Jones Application Engineer

2401 Gas (liquid) Chromatography

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension

BP1 PONA BPX1. GC Capillary Columns BP1 PONA and BPX1

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Introduction to Capillary GC

Evaluation of Capillary Columns for General Performance Parameters

Paints and varnishes Determination of volatile organic compound (VOC) content. Part 2: Gas-chromatographic method

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Chromatography and Functional Group Analysis

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

The Suite for Environmental GC Analysis

Principles of Instrumental Analysis

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

DIQUAT DIBROMIDE. The Determination of Ethylene Dibromide in Diquat Dibromide and Diquat Dibromide / Paraquat Dichloride SL Formulations

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Chemistry Instrumental Analysis Lecture 27. Chem 4631

GC Instruments. GC Instruments - Sample Introduction

Partitioning. Separation is based on the analyte s relative solubility between two liquid phases or a liquid and solid.

Chapter 11 Conventional Gas Chromatography

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

CEE 772: Instrumental Methods in Environmental Analysis

Biochemistry. Biochemical Techniques. 12 Gas Liquid Chromatography

Experiment 6 Simple and Fractional Distillation

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Choosing the Correct GC Column Dimensions and Stationary Phase

GC-CI-MS analysis of TMS derivatives

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

Rtx-BAC Plus 1 and Rtx-BAC Plus 2 Columns Advanced Technology for Fast, Reliable Measurement of Alcohol in Blood

NEW Rtx -BAC Plus 1 and Rtx -BAC Plus 2 Columns

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

for Acclaim Mixed-Mode HILIC-1 Column

LC and LC/MS Column Selection Flow Chart

Transcription:

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. Jaap de Zeeuw, Ron Stricek and Gary Stidsen Restek Corp Bellefonte, USA To analyze basic compounds at nano gram levels using gas chromatography, a basic surface modification is often required to reduce the impact of the acidic fused silica. Additionally, to separate volatile components, retention and efficiency at lower temperatures is required also. Base-modified polyethylene glycols have been available for some time, but are not very stable and they loose efficiency when used below 60C. Siloxanes are more challenging for base modification as the stability siloxane polymer should not be compromised. There are some solutions available, but there is room for improvement as present phases technologies are considered not optimal which translates in short column life times and non-reproducibility in amine response.. An advanced base deactivation technology has been made available several years ago by Restek corporation, where a new surface deactivation of fused silica was introduced. Such columns were commercialized under the names Rtx-5 amine and Rtx-35 amine. Similar approach was taken for designing a more stable column for volatile amines, not only by increasing the film thickness, but also by creating a direct link with the (base) surface deactivation. Additionally the number of cross-links (bridges) between polymer chains was optimized to make the polymer keeps efficiency as low as temperatures of 40 ºC. The higher degree of cross-linking was incorporated to make the column more resistant for amine/water mixtures. The column, named Rtx Volatile amines, was tested with a series of amine samples and water matrices, to demonstrate performance. In this poster, several applications will be presented and discussed. Introduction The analysis of small chain amines is of great importance for the chemical industry as well as in pharmaceutical analysis. Volatile amines are building blocks or reactants for manufacture of many different classes of compounds. The analysis of small chain amines by capillary gas chromatography is challenged because of the high polarity and the basic nature of the amine compounds. Any activity in the system will immediately impact amine peak symmetry and response. Analysis of amines Amines are generally known to be very difficult to analyze due to their basic character. With decreasing molecular size the influence of the amine group becomes larger which results in stronger adsorption characteristics. Most critical are the primary amines. Besides the basic character the amino group introduces a large dipole in the molecule. This dipole is responsible for strong interaction with silanol groups and siloxane bridges 1

which often results in non-linear adsorption effects. This appears as strong tailing peaks in the chromatogram. There are several gas chromatographic ways to do amine analysis. The packed column has been used widely with modified and mixed phases. Typical packings are the polyethylene glycol (PEG) mixed with potassium hydroxide or sodium hydroxide. These packings provide excellent peak shapes for amines. Also porous polymers with a basic modification can be used for this separation. The best way to prevent the interaction of the strong dipole is to derivatize the amine or to deactivate the column in such a way that the interaction is minimized. Derivatization is not preferred as it is time consuming and all kinds of secondary effects like recoveries and matrix effects are introduced. Practical amine analysis: priming Practically in amine analysis, systems are often primed. Here a few repeated injections of a high boiling amine compound is performed. The high boiling amine will cover the active site, resulting in better chromatography. This deactivation is usually only temporarily as the amine will not remain at the active site. Amine priming must be repeated on regular basis. Advantage of the method is, that by injecting the whole chromatographic system is deactivated, including injection/detection port liners. Capillary columns for volatile amine analysis: challenges Columns for volatile amines must have a high degree of deactivation, combined with retention. Additionally they must be chemically resistant for tough matrix conditions. Amines are often analyzed together with water and alcohols. Also ammonia and water do have to be quantified. Commercial available columns dedicated for volatile amines work fine when amines are in pure condition, but as soon as the matrix becomes tough, the chromatography becomes challenging. Figure 1 shows what typically happens when those columns are used for amine-water mixtures. The amine peaks rapidly show poor peak shapes. They split-up and elute with chair type shape. This makes quantification very unreliable and unpredictable, especially in a routine measurement environment. To confirm these results, a standard deactivated thick-film Rtx column was tested using the same matrix. The same phenomena were observed, see figure 2. In order to get better stability, some Figure 1; Peak shape of short chain amine on commercial column dedicated for volatile amines; Conditions table 1; 2

fundamental change was required. The impact of the fused silica surface as well as the stability of the stationary phase needed to be improved by using more robust surface deactivation and stable polymers. New Rtx Volatile Amine column A series of columns were prepared using a deactivation technology that was explored when Restek developed the Rtx-5 and 35 amine columns. The basedeactivation of the surface greatly reduces the interaction of small chain amines, providing less adsorption and better peak Figure 2: Short chain amines on standard deactivated column; conditions, table 1; shapes. Additionally, the stationary phase layer was bonded with the surface and was also more intensively cross linked to have better mechanical stability. As we have learned from the Rxi-deactivation technology, we made sure that remaining reactive silanols in the stationary phase were eliminated. The resulting column was tested with a series of mixtures which results are shown in figures 3-7 Figure 3: Impurities in trimethylamine; conditions: see table 1; 3

Figure 3 and 4 show the analysis of gas samples of amine compounds. These samples are the most simple and chromatography looks good. Figure 5 shows the same components, but now in water matrix. Usually when water is involved there are different matrix interactions which affect peak shape. The figure show an overlay of amines, 200-1000 ppm in water, of the first and 40 th injection. Peak shapes are almost identical. This was a very promising result. Figure 6 shows a detail where there is a slight increase in tailing observed (blue trace). Figure 7 shows the analysis of 40% solution of monomethylamine in water. This mixture is known to be very difficult and is a perfect indicator for column stability. The figure shows the first and 50 th analysis. There is a small impact in peak shape, but this is minimal compared with the former chromatography solutions available. Figure 4: Short chain amines on Rtx-Volatile amines Figure 5: short chain amines in water matrix. Overlays of 1 st and 40 th injection; conditions: table 1 Figure 6: Detail of figure 5. 4

Table 1 Conditions for small chain amine amine testing Column ` : 60 m x 0.32mm Rtx-Volatile amines GC : Agilent 6890 Injection : Split; Spit 1:15 ; 30 ml/min Injection volume : 1.0µl, Fast plunger mode Injection temp : 220 C Carrier Gas : H2, flow = 2 ml/min; constant flow; 64.2 kpa velocity 35 cm/sec Oven : Initial 40 C 10 min., 20 C/min to 250 C -10min isothermal Detection : FID, temp. 250C Figure 7: 40% mono-methylamine in water; conditions see table 1; Table 2 Abbreviations and retention times Retention time [min] MMA monomethyl-amine 4.95 meoh methanol 5.79 DMA dimethyl amine 6.92 EA ethyl-amine 7.11 TMA trimethyl-amine 7.87 IPA isopropyl amine (IS) 10.12 MEA methyl-ethyl-amine 11.1 DMEA dimethyl-ethyl-amine 12.5 DEA diethyl-amine 14.0 MDEA methyl-diethyl-amine 15.2 5

The Rtx volatile amines performs very good for polar amines, not only because of inertness and water tolerance, also for loadability. Figure 8-12 show several applications for impurity analysis in main amine compounds. Figure 13-15 show the separation of gases and water using TCD detection. Ammonia and water elute as sharp peaks. The column can also be used for measuring trace amounts of water in solvents, replacing Karl Fisher titration. Figure 8: impurities in pyridine; conditions see table 3 Table 3 Conditions for impurity analysis Column : 60m x 0.32mm Rtx-Volatile amines GC : Agilent 6890 Oven : 120 ºC Carrier gas : Hydrogen, 2 ml/min; 23 psi Injection : split, 1:15, 250 ºC, 1 μl Detection : FID, 250ºC 6

Figure 9: Impurities in diethylamine, conditions: table 3 Figure 10 impurities in triethylamine, conditions see table 3 7

Figure 11: Impurities in picoline, conditions table 3; Figure 12 Impurities in isopropylamine, conditions table 3 8

Figure 13:Ammonia and water; Column: 60m x 0.32mm Rtx-Volatile amines; Oven: 45 ºC; Injection: split, 1: 10; Carrier: Helium, 150kPa; GC: HP5890; Detection: μ-tcd; Figure 14: carbon dioxide and ammonia; conditions see fig. 13 9

Figure 15: water content in ethanol; conditions fig 13, but oven at: 60 ºC Summary A new stable bonded stationary phase for amine application has been developed which is based on a non-polar stabilized polysiloxane. Because of the surface bonding and base deactivation of the fused silica surface, the Rtx-Volatile amines can handle direct liquid injections of water, with high level of short-chain amine like monomethylamine, dimethylamine and trimethylamine. The new phase shows a very good peak shape for amines, alcohols, ammonia, CO2 and water and can be used at least up to 275 C. Acknowledgement Special thanks to Gilbert Baele,Taminco, Belgium, for testing the application and limitation of the base deactivation technology Availability #565064 Rtx-Volatile amine, 15m x 0.32mm #565143 Rtx-Volatile amines 30m x 0.32mm #564168 Rtx-Volatile amines 60m x 0.32mm 10