Applications. Remote Weather Station with Telephone Communications. Tripod Tower Weather Station with 4-20 ma Outputs

Similar documents
WEATHER STATION FOR SOLAR FARM MONITORING

TB-2012M BAROMETRIC PRESSURE SENSOR USER S MANUAL

PAM-Station Land-Owner Information Guide Project: CuPIDO, Tucson AZ, Jul/Aug 2006

Quality Assurance and Quality Control

Urban Dispersion Program New York City Mesonet ROOFTOP WEATHER STATION NETWORK

WeatherHawk Weather Station Protocol

Product Description. 1 of 6

Weather Stations. Evaluation copy. 9. Post live weather data on the school s web site for students, faculty and community.

MKIII -MB USER S GUIDE 09/18/18. Rev. 3

Weather Monitoring Instruments & Systems

Model 3024 Albedometer. User s Manual 1165 NATIONAL DRIVE SACRAMENTO, CALIFORNIA WWW. ALLWEATHERINC. COM

Consumer Guide. Southwest Windpower 1801 W. Route 66 Flagstaff, AZ USA

Chapter 2 Agro-meteorological Observatory

Centralized Forecasting Registration and Communication Requirements for Distribution Connected Variable Generators. IESO Training

Meteorological Instruments for Solar Energy

APPENDIX 3.6-A Support Information for Newcastle, Wyoming Meteorological Monitoring Site

LP PYRA Installation and Mounting of the Pyranometer for the Measurement of Global Radiation:

What is the maximum distance I can have the remote sensors from the display?

WYANDOTTE MUNICIPAL SERVICES COMMUNITY WIND ENERGY PROJECT WIND RESOUCE SUMMARY

Your Farm Weather Station: Installation and Maintenance Guidelines 1

Clutter characterization and propagation measurements during adverse weather conditions

RWSC ARWIS Specifications - Sensors & Accuracy

Vermont Soil Climate Analysis Network (SCAN) sites at Lye Brook and Mount Mansfield

The Status of Meteorological Observation in the Asian Countries

AWOS. Automated Weather Observing Systems COASTAL

Meteorological Service

Deploying Weather Stations: A Best Practice Guide

Meteorological QA/QC

Overview of the Thunderbird Micronet

INSTALLATION OF PORTABLE O3 MONITORING STATION NATIONAL PARK SERVICE AMBIENT AIR QUALITY AND METEOROLOGY MONITORING NETWORK

Website Phone Mobile OVERVIEW Davis Vantage Pro2 Weather Station

HD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION

General Information: Real-time onsite solar forecasting

Wind Resource Assessment Practical Guidance for Developing A Successful Wind Project

Station Maintenance and Calibration Report ABRAHAM LINCOLN BIRTHPLACE NATIONAL HISTORIC SITE March 13, 2007

iweathar EDGE V Installation Guide Copyright 2012 iweathar. All rights reserved.

Use of Infrared Thermography for Building Inspection

LP NET. 1 About LP NET. 2 Working Principle. TEL r.a. FAX

Comparative analysis of data collected by installed automated meteorological stations and manual data in Central Asia.

for JMA/WMO Training Workshop on CALIBRATION AND MAINTENANCE OF METEOROLOGICAL INSTRUMENTS

Visibility and present weather sensors. you can trust... visibly better

WMO number: Internal Station number: same as WMO number, historic AWOS documents refer to the station as A19. Current Station Location

Quality assurance for sensors at the Deutscher Wetterdienst (DWD)

2016 EXPLANATION OF OBSERVATIONS BY REFERENCE NUMBER

SENSOR PLACEMENT FOR SNOW & ICE MELT APPLICATIONS

Innovative Sustainable Technology

MeteoSwiss acceptance procedure for automatic weather stations

SIMILAR TRIANGLES PROJECT

Digital Stored Grain Quality Management. BinMaster Level Controls Lincoln, Nebraska, USA

Series tore word. Acknowledgements

The Colorado Climate Center at CSU. residents of the state through its threefold

Interview with Dr. Jaya Singh. 1. How critical is weather monitoring in a solar power plant and what are all the parameters to be monitored?

4 Forecasting Weather

MANAGEMENT OF THE NIEMEN RIVER BASIN WITH ACCOUNT OF ADAPTATION TO CLIMATE CHANGE. Hydro-meteorological Monitoring System

473 Dew Point Hygrometer

LOG_aLevel. Tsunami Warning System

WARRANTY AND ASSISTANCE

A TEST OF THE PRECIPITATION AMOUNT AND INTENSITY MEASUREMENTS WITH THE OTT PLUVIO

Cabled Vantage Pro2 & Vantage Pro2 Plus Stations

BERMAD Irrigation. BIC2000 Weather Station SYSTEM GUIDE VERSIONS : BIC ; PC 4.90

SENSOR. Weather TRANSMITTERS

A comparison between two types of widely used weather stations

WEATHER STATION MANUAL. Dacom Farm Intelligence COC: version: April 2018 VAT: NL B01

Chapter 1 SEDNA Meteorological Data

OASIS WIRELESS WEATHER STATION

473 Dew Point Hygrometer

СИСТЕМЫ ИЗМЕРЕНИЯ ВЕТРА WTS 140, 150, 250, 520, 700

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

Development of Innovative Technology to Provide Low-Cost Surface Atmospheric Observations in Data-sparse Regions

Gridding of precipitation and air temperature observations in Belgium. Michel Journée Royal Meteorological Institute of Belgium (RMI)

Data Acquisition System for Photovoltaic Water Pumping System in the Desert of Tunisia

Making Accurate Field Spectral Reflectance Measurements By Dr. Alexander F. H. Goetz, Co-founder ASD Inc., Boulder, Colorado, 80301, USA October 2012

3.2 Wind direction / wind velocity

Climatic Change Implications for Hydrologic Systems in the Sierra Nevada

AUTOMATION OF OBSERVING NETWORK IN BMKG

Device Specifications

QUICK SET UP MANUAL WEATHER CENTER

EAS 535 Laboratory Exercise Weather Station Setup and Verification

Community Collaborative RAin, Hail and Snow network. CoCoRaHS.

The Montague Doppler Radar, An Overview

AERMOD Sensitivity to AERSURFACE Moisture Conditions and Temporal Resolution. Paper No Prepared By:

WeatherWatcher ACP. Astronomers Control Panel (V4 or >) Ambient Virtual Weather Station (Pro or Internet editions) ASCOM platform v4.

Automated data logging instrumentation system for wind speed and direction measurements

STANDARD OPERATING PROCEDURES

Low Cost Weather Stations for Developing Countries (Kenya)

UWM Field Station meteorological data

6.5 QUALITY ASSURANCE AUDIT PROGRAM FOR SURFACE AND UPPER-AIR METEOROLOGICAL MEASUREMENTS IN THE SOUTH COAST AIR BASIN OF CALIFORNIA

1 What Is Climate? TAKE A LOOK 2. Explain Why do areas near the equator tend to have high temperatures?

MS-100 Weather Station Quick-start Guide Rev E

Comparison between air temperature measured inside a conventional large wood shelter and by means of present day screens

WEATHER MULTI-SENSOR. Vaisala Weather Transmitter WXT510. Change the Way You Measure Weather

Twice-Annual Station Maintenance and Calibration Report BIG BEND NATIONAL PARK February 1, 2012

Structure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor

Signature Series User s Manual

A Rain Sensitive House Window Closes Automatically When Raining

Objective. Background

Site: M001/W026 Network: W Update Date: 03/01/2014 Observer: ELW & DTY Version: 3.0

Instruction Manual. Solar Weather Centre With Wireless Weather Vane. Product Code: WS5056C. Solar Powered Outdoor Weather Data Collector

ISSPRO 3 3/8 Programmable Tachometer High Performance EV Line Part Numbers R5535M, R6535M

WM9280. Pro Family weather station with T/H sensor, pluviometer, anemometer, PC connection and Meteotime weather forecasts until 3 days

Transcription:

Tripod Tower Weather Station with 4-20 ma Outputs Remote Weather Station with Telephone Communications NEMA-4X Enclosure with Two Translator Boards and Analog Barometer Typical Analog Output Evaporation Station

System Design NovaLynx is an industry leader in the design, fabrication, and integration of meteorological systems. Using the best possible combination of sensors, signal conditioning, and data acquisition technologies, NovaLynx can customize and fit any combination of meteorological sensors and signal processing equipment to customer applications. Sensors with signal translators provide a variety of systems supporting analog signal displays, digital panel meter displays, and strip chart recordings. NovaLynx also provides several data logger based systems for digital signal acquisition, display, and storage, with additional data processing using personal computers. Telemetry systems for either analog or digital data allow transmission of data to locations at some distance from the sensors. In addition to the standard array of meteorological sensors, signal conditioners, data loggers, and recorders, NovaLynx provides towers, sensor masts and mast adapters, cables, solar radiation shields with or without fans, and installation assistance. Special system hardware not shown in this catalog can be provided. NovaLynx can design and manufacture custom mounting hardware such as sensor mounting fixtures, enclosures, and panels, as well as configure standard products to meet unique requirements. Additional information is provided in the catalog sections covering specific system components. Custom system quotations with descriptive literature are available upon request. Regulation Conforming Systems: NovaLynx can configure custom systems to meet strict governmental regulations. Government agencies such as the U.S. Environmental Protection Agency (EPA) and Department of Energy (DOE) require certain manufacturers and industries to monitor pollution generating processes by using meteorological monitoring equipment to track pollution dispersion. These special systems require specific meteorological instrumentation, installed with specific hardware at exact elevations and in some cases at more than one location. The sensors and signal conditioning equipment provided by NovaLynx allows easy configuration in order to meet the rigid requirements involved in these strict applications. Tower-Mounted Meteorological Monitoring System 4

Site Considerations Selecting the proper site for weather station sensors is just as important as selecting the proper sensor for a particular application. Siting standards should be given first consideration in sensor placement, however, unusual requirements may call for special siting techniques. The discussion below refers to installations in the northern hemisphere. Wind Speed and Direction The quality of wind sensors can be diminished by poor exposure to local topography. Placement of the wind sensors should follow standards established by agencies such as the World Meteorological Organization (WMO) and the United States National Weather Service (NWS). The standard exposure of wind instruments over level, open terrain is 33' (10 meters) above the ground (WMO 1971). Open terrain means the distance between the wind sensors and the nearest obstruction is at least ten times the height of that obstruction. For roof-mounted sensors, the exposure should be at a height that is at least 1.5 times the height of the building. For extremely tall buildings this rule can be difficult to follow. For tall buildings, the sensors should be at least 33' (10 meters) above the roof or above the tallest obstruction on the roof. Whenever possible the sensors should be placed on the upwind side of the building. Ventilation and exhaust vents must be avoided. For ground-mounted sensors near a building, the upwind side of the building is preferred, with the sensors located at a distance that is at least one times the height of the building. The downwind side of the building requires that the sensors be located at a distance of five to ten times the height of the building. When wind sensors are located too close to a building wind-milling of the direction vane will occur and the speed sensor will measure artificial gustiness. The sensors are actually monitoring the wind turbulence created by the building. While the WMO standard for siting wind sensors at ten meters above ground level provides ambient wind monitoring, in micrometeorology wind sensors are often placed closer to the ground. This allows for wind monitoring in the environment of interest. Multiple levels of sensors may be used to provide more detailed wind information. Applications Preliminary studies of the sensor location should be performed using flags, smoke, or by temporary installation of the sensors. If wind sensors must be located amid vegetation, pick a spot that is about equidistant from the tallest trees or shrubs. A clearing with a diameter at least ten times the height of the tallest tree or shrub would be ideal. Even with the best possible location amid vegetation, it is sometimes necessary to add some height to the sensor mast in order to get better exposure. Relative Humidity, Air Temperature, and Dew Point Temperature These sensors should be installed in a properly ventilated solar radiation shield for accurate ambient measurements. Cotton region type instrument shelters provide the standard aspiration and solar protection for these sensors. Mast-mounted self aspirated and motor aspirated shields may provide adequate exposure as well, depending on the application. Mast-mounted sensors are usually positioned at shelter height, or about four feet above ground level, on the north side of the mast. Solar Radiation Solar radiation sensors may be mast or pole mounted. They should always be located in an open area, in full view of the sun at all times. When mast mounting or placing in an area where nearby obstructions are present, locate the sensor to the south of all obstacles. This will prevent shadows created by the nearby obstacles from passing over the sensor. These sensors are usually mounted approximately two meters above ground level. Precipitation Whether heated or unheated, rain and snow sensors should always be located in a relatively flat, open area. Some obstructions can be helpful to block the wind for more accurate catch. However, leaves from trees can cause increased gauge maintenance. If natural wind breaks are not available, a wind screen accessory is recommended. 5

Typical System Drawings Indicating Wind Station Recording and Indicating Wind Station Indicating Wind Station with 4-20 ma Outputs Wind Station with Wind Tracker Displays Recording, Indicating, and Logging Wind Station 6

Typical System Drawings Applications Roof Mounted Weather Station Indicating Wind Station with Wireless Data Transmission System Ten Meter Tower Weather Station PC-Based Weather Station Data Logger Weather Station 7

Typical System Drawings Wind Sensor 200-05103 Wind Sensor Cable 330-0524 Solar Radiation Shield - 380-281 Temp/RH Sensor - 225-HMP50Y Temp/RH Sensor Cable - 330-0524 30-FT TOWER FREE STANDING MODEL 190-611 NEMA-4X Junction Box WS-16N Data Logger +12 Vdc Battery & Charging Circuit Analog Output Barometer 230-600 Direct Data Download or Optional Telephone Modem Rain Gauge Cables Signal - 330-0220 Power - 330-0316 Tipping Bucket Rain Gauge 260-2500E Wind Screen 260-952 8