AN EXPERIMENTAL STUDY OF MIXED CONVECTION HEAT TRANSFER IN AN INCLINED RECTANGULAR DUCT EXPOSED TO UNIFORM HEAT FLUX FROM UPPER SURFACE

Similar documents
5th WSEAS Int. Conf. on Heat and Mass transfer (HMT'08), Acapulco, Mexico, January 25-27, 2008

Introduction to Heat and Mass Transfer. Week 14

Combined Convection Heat Transfer at the Entrance Region of Horizontal Semicircular Duct

Fluid Flow and Heat Transfer of Combined Forced-Natural Convection around Vertical Plate Placed in Vertical Downward Flow of Water

Introduction to Heat and Mass Transfer. Week 14

Convection. forced convection when the flow is caused by external means, such as by a fan, a pump, or atmospheric winds.

Experimental Analysis of Rectangular Fin Arrays with Continuous Fin and Interrupted Fins Using Natural and Forced Convection

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

PHYSICAL MECHANISM OF NATURAL CONVECTION

Convection Heat Transfer. Introduction

UNIT II CONVECTION HEAT TRANSFER

Chapter 7: Natural Convection

EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT

INSTRUCTOR: PM DR MAZLAN ABDUL WAHID

MYcsvtu Notes HEAT TRANSFER BY CONVECTION

Lecture 30 Review of Fluid Flow and Heat Transfer

Natural Convection Heat Transfer inside a Narrow Triangular Enclosure with Rectangular Staggered Finned Base Plate: An Empirical Correlation

Chapter 9 NATURAL CONVECTION

FREE CONVECTIVE HEAT TRANSFER FROM AN OBJECT AT LOW RAYLEIGH NUMBER

PARAMETRIC STUDIES ON HEAT TRANSFER BY NATURAL CONVECTION IN VERTICAL CHANNEL USING INCLINED V-SLOT PLATE AN OVERVIEW

CHME 302 CHEMICAL ENGINEERING LABOATORY-I EXPERIMENT 302-V FREE AND FORCED CONVECTION

Laminar Mixed Convection in the Entrance Region of Horizontal Quarter Circle Ducts

THE INFLUENCE OF INCLINATION ANGLE ON NATURAL CONVECTION IN A RECTANGULAR ENCLOSURE

HEAT TRANSFER BY CONVECTION. Dr. Şaziye Balku 1

Chapter 3 NATURAL CONVECTION

Lecture 28. Key words: Heat transfer, conduction, convection, radiation, furnace, heat transfer coefficient

Natural and Mixed Convection Heat Transfer Cooling of Discrete Heat Sources Placed Near the Bottom on a PCB

Experimental Analysis of Natural Convective Heat Transfer Performance From Rectangular Fin Array with Perforations

Convection Workshop. Academic Resource Center

Tutorial 1. Where Nu=(hl/k); Reynolds number Re=(Vlρ/µ) and Prandtl number Pr=(µCp/k)

Outlines. simple relations of fluid dynamics Boundary layer analysis. Important for basic understanding of convection heat transfer

C ONTENTS CHAPTER TWO HEAT CONDUCTION EQUATION 61 CHAPTER ONE BASICS OF HEAT TRANSFER 1 CHAPTER THREE STEADY HEAT CONDUCTION 127

THERMALLY DEVELOPING MIXED CONVECTION IN A HORIZONTAL EQUILATERAL TRIANGULAR CHANNEL

Thermo-Hydraulic Performance of a Roughened Square Duct Having Inclined Ribs with a Gap on Two Opposite Walls

CONVECTIVE HEAT TRANSFER

Thermo-Fluid Performance of a Vapor- Chamber Finned Heat Sink

Conjugate heat transfer from an electronic module package cooled by air in a rectangular duct

"Experimental investigation of heat transfer enhancement by u-shaped Turbulator"

Principles of Convection

Summary of Dimensionless Numbers of Fluid Mechanics and Heat Transfer

Experimental Analysis for Natural Convection Heat Transfer through Vertical Cylinder

Analysis, Design and Fabrication of Forced Convection Apparatus

Assessment of the Baffle Effects on the Mixed Convection in Open Cavity Nabil Jamil Yasin 1, Kadhum Audaa Jehhef 2, Asraa Mahdi Shaker 3 1,3

Problem 4.3. Problem 4.4

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

Forced Convection Heat Transfer in the Entrance Region of Horizontal Tube under Constant Heat Flux

NUMERICAL STUDY OF HEAT AND MASS TRANSFER DURING EVAPORATION OF A THIN LIQUID FILM

Heat Transfer Convection

COMPUTATIONAL ANALYSIS OF LAMINAR FORCED CONVECTION IN RECTANGULAR ENCLOSURES OF DIFFERENT ASPECT RATIOS

ELEC9712 High Voltage Systems. 1.2 Heat transfer from electrical equipment

Heat Transfer F12-ENG Lab #4 Forced convection School of Engineering, UC Merced.

LAMINAR NATURAL CONVECTION HEAT TRANSFER FROM AN ISOTHERMAL VERTICAL RIBBED PLATE

W-Discrete Rib for Enhancing the Thermal Performance of Solar Air Heater

Natural convection heat transfer around a horizontal circular cylinder near an isothermal vertical wall

Experimental Investigation of Heat Transfer from a Flat and Surface Indented Plate Impinged with Cold Air Jet- Using Circular Nozzle

PHYSICAL MECHANISM OF CONVECTION

HEAT TRANSFER THERMAL MANAGEMENT OF ELECTRONICS YOUNES SHABANY. C\ CRC Press W / Taylor Si Francis Group Boca Raton London New York

If there is convective heat transfer from outer surface to fluid maintained at T W.

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

CFD STUDIES IN THE PREDICTION OF THERMAL STRIPING IN AN LMFBR

CONVECTIVE HEAT TRANSFER

NATURAL CONVECTIVE HEAT TRANSFER FROM A RECESSED NARROW VERTICAL FLAT PLATE WITH A UNIFORM HEAT FLUX AT THE SURFACE

Table of Contents. Foreword... xiii. Preface... xv

Experimental Validation of Heat Transfer Enhancement in plate Heat Exchanger with Non Conventional Shapes of Rib

NATURAL CONVECTION HEAT TRANSFER CHARACTERISTICS OF KUR FUEL ASSEMBLY DURING LOSS OF COOLANT ACCIDENT

CFD Analysis of Forced Convection Flow and Heat Transfer in Semi-Circular Cross-Sectioned Micro-Channel

Experimental Study of Heat Transfer Enhancement in a Tilted Semi-Cylindrical Cavity with Triangular Type of Vortex Generator in Various Arrangements.

MERGING OF SHEET PLUMES IN TURBULENT CONVECTION

Flow and heat transfer characteristics of tornado-like vortex flow

Comparative study of Different Geometry of Ribs for roughness on absorber plate of Solar Air Heater -A Review

An Investigation into Forced Convection Heat Transfer through Porous Media

Transactions on Engineering Sciences vol 18, 1998 WIT Press, ISSN

TankExampleNov2016. Table of contents. Layout

Augmented Heat Transfer in Square ducts with Transverse and Inclined Ribs with and without a gap


Introduction to Heat Transfer

Experimental Heat transfer study of Turbulent Square duct flow through V type turbulators

Experimental Investigation of Natural Convection Heat Transfer in Heated Vertical Tubes

Investigation of Heat Transfer Enhancement in Laminar Flow through Circular Tube Combined Wire Coil and Wavy Strip with Central Clearance

Experimental investigation of heat transfer augmentation in triangular duct with rectangular wing

THE CHARACTERISTIC LENGTH ON NATURAL CONVECTION FROM A HORIZONTAL HEATED PLATE FACING DOWNWARDS

Laplace Technique on Magnetohydrodynamic Radiating and Chemically Reacting Fluid over an Infinite Vertical Surface

Natural Convection in Parabolic Enclosure Heated from Below

Abstract. Introduction

FINITE ELEMENT ANALYSIS OF MIXED CONVECTION HEAT TRANSFER ENHANCEMENT OF A HEATED SQUARE HOLLOW CYLINDER IN A LID-DRIVEN RECTANGULAR ENCLOSURE

International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May ISSN

HEAT TRANSFER IN THE LAMINAR AND TRANSITIONAL FLOW REGIMES OF SMOOTH VERTICAL TUBE FOR UPFLOW DIRECTION

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

Experimental Evaluation of Natural Heat Transfer in Façade Integrated Triangular Enclosures

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

Department of Mechanical Engineering ME 96. Free and Forced Convection Experiment. Revised: 25 April Introduction

Analysis of Heat Transfer Enhancement in Spiral Plate Heat Exchanger

The influence of a magnetic field on turbulent heat transfer of a high Prandtl number fluid

MECHANISM BEHIND FREE /NATURAL CONVECTION

Theoretical and Experimental Studies on Transient Heat Transfer for Forced Convection Flow of Helium Gas over a Horizontal Cylinder

Entropy 2011, 13, ; doi: /e OPEN ACCESS. Entropy Generation at Natural Convection in an Inclined Rectangular Cavity

INTERNATIONAL JOURNAL OF ADVANCED RESEARCH IN ENGINEERING AND TECHNOLOGY (IJARET)

STABILITY ANALYSIS FOR BUOYANCY-OPPOSED FLOWS IN POLOIDAL DUCTS OF THE DCLL BLANKET. N. Vetcha, S. Smolentsev and M. Abdou

Free and Forced Convection Heat Transfer Characteristics in an Opened Box with Parallel Heated Plates

In Chapters 7 and 8, we considered heat transfer by forced convection,

Transcription:

AN EXPERIMENTAL STUDY OF MIXED CONVECTION HEAT TRANSFER IN AN INCLINED RECTANGULAR DUCT EXPOSED TO UNIFORM HEAT FLUX FROM UPPER SURFACE Dr. Ahmed F. Khudheyer Ali Jawad Obaid Mazin Y. Abdul-Kareem ahyaja@yahoo.com Waal_ali2002@yahoo.com mazinyahia@yahoo.com Abstract Combined free and forced convection heat transfer to a thermally developing air flow in a rectangular duct has been studied experimentally. Experimental part deals with the laminar flow. The study was presented to steady and two dimensions flow. The heated surface was subjected to a constant heat flux while the duct short sides were kept unheated, for upper side heated only with constant heat flux and for three-duct angles of inclination -30, -45 and -60. In the experimental study, the heat flux applied to the heated surfaces varied from 40 to 500 W/m 2. This provides a modified Grashof number varied from 2.38*10 6 to 2.8*10 8 respectively, while the Reynolds number varied from 455 to 2000. Nomenclature Gr Dq = Grashof number based on De and heat flux, (βgd 4 q) / (k.ν 2 ) Gr L = Average Grashof number, βgl3 ΔT L /ν 2 Gr D = Grashof number based on De, βgd3 ( ΔT )x /ν 2 Nu L = Average Nusselt number, (h L.L / k) D e = Equivalent duct diameter, m T B = Bulk temperature, C T SL = Lower surface temperature, C T Su = Upper surface temperature, C U i = Inlet velocity, m/s Nu D = Nusselt number based on D, (h L.D / k) Pr = Prandtl number, (ν/α) Ra L = Average Rayleigh number, (Gr L.Pr) Re D = Local Reynolds number based on D, (u i. D / ν) ΔT = Temperature difference, C α = Duct angle of inclination (-30,-45 and - 60 ) Introduction

International Journal of Scientific & Engineering Research Volume 4, Issue 2, February-2013 2 An investagation of fully developed mixed convection in an inclined rectangular duct is presented. Mixed convection flows arise in many transport processes in natural and engineering devices. Atmospheric boundary layer flow, heat exchangers, solar collectors, nuclear reactors, and electronic equipments are some examples. Such a process occurs when the effect of the buoyancy force in forced convection or the effect of forced flow in free convection becomes significant. In the study of internal flows of mixed convection heat transfer, the interactions of thermal and hydrodynamic development become fairly complicated For inclined ducts, the gravity force acts in the vertical direction, and As will as the buoyancy force is in the main flow direction and induces secondary flows in the cross plane. Many works have been investigated on mixed heat transfer in laminar or turbulent flows in inclind rectangular ducts Yan [1] has studied numerically on the transport phenomena of mixed convection heat and mass transfer in an inclined rectangular duct. He found that the buoyancy forces distort the velocity, temperature and concentration distributions. Huang and Lin [2] investigated the transient mixed convection air flow in a bottom heated inclined rectangular duct. Attention wasparticularly paid to delineate the effects of the duct inclination on the flow transition with heat transfer only. W. L. Pu, P.Cheng and T. S. Zhao (1999) [3] carried out in the range of 2<Pe<2200 and 700<Ra<1500. The measured temperature distribution indicates the existence of a secondary convective cell inside the vertical packed channel in the mixed convection regime. A correlation equation for Nusselt number in terms of Peclet number Pe and Rayleigh number Ra was obtained from experimental data. A plot of Nu/Pe1/2 vs Ra/Pe exhibits the transition of heat transfer results from the natural convection limit to the forced convection limit. It is found that the following three convection regimes exist: natural convection regime: 105< Ra/Pe, mixedconvectionregime:1<ra/pe<105,and forced convection regime: Ra/Pe< 1.

International Journal of Scientific & Engineering Research Volume 4, Issue 2, February-2013 3 Paulo and Genesio (2004) [2], studied the mixed convection heat transfer in an inclined rectangular channel. Three heat sources with finite lengths are flush mounted on the bottom surface of a channel. The Reynolds number, Grashof number and inclination angle are ranged as follows: 1 Re 1000, 103 Gr 105 and 00 γ 900. Three comparisons between experimental and numerical results were performed. It is observed that the inclination angle has a stronger influence on the flow and heat transfer for Reynolds number equals to 1000, especially when it is between 00 and 450. The cases which present the lowest temperature distributions on the modules are those where the inclination angles are 450 and 900 with little difference between them. The case where Gr = 105 and Re = 1000, is an exception where γ equals 00 is the best channel inclination. It is noted that the study of developing mixed convection flow in inclinedrectangular ducts is useful in practical sense, but it has not received enough attention and the studies of developing mixed convection flow in inclined ducts. The aim of this study is to investigate the effects of inclination duct on the developing mixed convection flow in inclined rectangular ducts. The design of industrial heat exchangers in chemical. Food processing industries where problems may be encountered involving combined convection in horizontal channels. Cooling of electrical equipment. The design of certain types of solar energy collectors (flat plate heater).the estimating of energy time scale required in the case of piping failure in the nuclear power plant. II. ANALYSIS 1. Problem Statement The geometry of this problem as schematically shown infig. 1 is a rectangular duct with inclination angle α, width w,and height h. The velocity components in x, y, and z directionsare denoted as u, v, and w, respectively. A uniform axialvelocity w o and a uniform temperature T o are imposed at theinlet z = 0. Although practical flows are often

International Journal of Scientific & Engineering Research Volume 4, Issue 2, February-2013 4 turbulent, theentering upward flow is The most important of the open air circuit assumed to be steady and laminar.the is the test section where most of the temperature of the injected or suctioned measurements fluid is the sameas that of the duct wall. vertical walls (shorter sides of rectangular The walls are imposed uniform heat flux. duct) the left and right wall consist of the were made. The two duct inside to the duct outside, a 20mm A.C Source Supports following, three layers arranged from the thick of asbestos sheet, a 20mm thick of upper and lower walls of test section were Digital Manometer Temp. Reader solid compressed wood, respectively. The designed to be the duct side heated with a constant heat flux so the situation of upper side heated or lower side heated or both side heated can be achieved by powering the side requires. The details of these Frame walls are shown in fig. (2). The heated A.C Motor Flaxiable Hose Thermocouples Test Section Multimeter Calmng Section Variac glass wool sheet and a 50mm thick of a surface was constructed from three layers glued together to form a composite heater. The composite heater consists of a heating element as nickrom 1mm diameter Air Dumper wounded uniformly flat on a 1mm mica Fig. 1 Schematically sketch for the rig. 2.Test Section. sheet. The heating element then covered from both sides by 1mm mica sheet. The heat element with covers fixed on 0.5mm stainless steel plate to force a composite layer heating element.

0.1 0.5 0.05 8 2 24 2 1,5 2 20 5 18 80 4.5 24 8 10 7 4 International Journal of Scientific & Engineering Research Volume 4, Issue 2, February-2013 5 Wood Glass wool Asbest Composite Heater Y X Stainless steel plate Mica sheet Heater 80 "All Dimensions in cm" Fig. (2) Test section duct composition All thermocouples penetrate the mica layer to be fixed on the stainless steel plate. Thermocouples locations are mentioned in fig. (3) starting from test section entrance. Fig (3) Distributed locations of thermocouples on the heaters plates III. RESULTS AND DISCUSSION 1. Velocity distribution study: Three velocity profile tests have been carried out for inclined duct opposing flow situations comprising combinations of

International Journal of Scientific & Engineering Research Volume 4, Issue 2, February-2013 6 three angles of inclination -30º, -45º and - 60º, The results for the upper side heated only situation at -30º, -45º and -60º are shown in Figs. (4), (5) and (6).The velocity profile for α = -30º, is shown in Fig. (4), reveals a conspicuous skewing of these profiles toward the upper plate especially at the duct center and 4-cm off-center positions. The shift of the velocity profile is increased toward the upper plate as (α) increases to -45º and -60º as shown in Figs. (5) and (6). The deformation in the upper plate boundary layer with (α) shows a clear merging of transverse profiles. m, Gr De =2.648*10 7, U i =0.388 m/s, T B =20ºC, T Su =71.7ºC, T SL =32.2ºC. Inclined duct, α = -30º, upper side heated, opposing flows. Fig. (5)Velocity profile. Re De =2064, x meas. =0.6 m, Gr De =2.58*10 7, U i =0.389 m/s, T B =17ºC, T Su =74ºC, T SL =34.6ºC.Inclined duct, α = -45º, upper side heated, opposing flows Fig. (4) Velocity profile. Re De =2060, x meas. =0.6

International Journal of Scientific & Engineering Research Volume 4, Issue 2, February-2013 7 Fig. (6) Velocity profile. Re De =2020, x meas. =0.6 m, Gr De =2.58*10 7, U i =0.377 m/s, T B =15ºC, T Su =69ºC, T SL =34.6ºC. Inclined duct, α = -60º, upper side heated, opposing flows. 2. Surface temperature : For the upper plate heated only case. The surface temperature distribution along the plate shown in fig. (7) for α=-30 indicates a reduction in surface temperature. This reduction is the result of the upper plate inclined (with the flow free to be carried away downstream) which is dominated by the natural convection. Surface temperatures reduce further as the duct orientation moves to α = -45º as shown in Fig. (8) but the reduction in the range between -30º to -45º is lower than that obtained -30º. Fig. (7) Axial variation of heated surface temperature, Inclined duct, α = -30, upper side heated only. Fig. (8) Axial variation of heated surface temperature, Inclined duct, α = -45, upper side heated only. The surface temperature distribution for α =-60º in Fig. (9) show the same trends as

International Journal of Scientific & Engineering Research Volume 4, Issue 2, February-2013 8 for α =-30º and -45º with a small reduction in surface temperature in comparison with α =-45º. Therefore, duct angle of inclination changes at -30º, manifests a large improvement in the local and average heat transfer coefficients. -45º and -60º. At the same time, the rate of improvement of NuLat low ReDrange is higher than that for high ReD. This behavior can be attributed to natural convection behavior and its contribution to the upper plate heat transfer process. Fig. (9) Axial variation of heated surface Fig. (01) Variation of Nu L with Re D, inclined duct, α temperature, Inclined duct, α = -60, upper side heated only. = -30, Upper side heated. 3. Nusselt number Average Nusselt number variation with Reynolds number for α=-30º, -45º and -60º are given in Figs. (01) to (01). The improvement in NuLis continued, for the same Grashof number GrDqand Reynolds number, as the duct orientation changes to

International Journal of Scientific & Engineering Research Volume 4, Issue 2, February-2013 9 Fig. (00) Variation of Nu L with Re D, inclined duct, α =-60, Upper side heated. Fig. (01) Variation of Nu L with Re D, inclined duct, α =-45 upper side heated IV. CONCLUSION Experimental studies have been performed to determine the effects of the secondary flow created by natural convection on a fully opposed developed air flow in a rectangular duct. The duct boundary conditions have been combined for inclined duct. The inclined duct results reveal the following conclusions:- 1. The biasing of the velocity profile towards the heated surface as α moves to upward. 2. As inclination angle increases, the buoyancy effect increases as well which causes an unstable secondary flow resulting the fluctuation in the distribution of Nu. 3. The upper plate Nu L is considerably improved as α = -30º and this improvement is lower for α = -45º and -60º. 4. In the uniform heat flux case, Nu is increased with increasing modified Raleigh number throughout duct.

International Journal of Scientific & Engineering Research Volume 4, Issue 2, February-2013 10 5. Nu is increased with increasing mixed convection parameter throughout the duct in the uniform heat fluxcase. REFERENCES 1. Yan, W. M., Transport phenomena of developing laminar mixed convectionheat and mass transfer in inclined rectangular ducts, InternationalJournal of Heat and Mass Transfer, Vol. 38, pp. 2905-2914(1995). 2. Huang, C. C. and Lin, T. F., Numerical simulation of transitional aiding mixed convection air flow in a bottom heated inclined rectangular duct, International Journal of Heat and Mass Transfer, Vol. 39, pp. 1697-1710(1996). 3. W. L. Pu, P.Cheng and T. S. Zhao An experiment study of mixed convection heat transfer vertical packed channels AIAA journal of thermophysics and heat transfer,vol.13 (4),pp.517-521, 1999. 4. Paulo M. Guimaraes and Genesio J. Menon, "Combined free and forced convection in an inclined channel with discrete heat sources", Mechanical Computational vol. XX III, pp. 2123-2140, 2004.