An Optimized Gamma-ray Densitometry Tool for Oil Products Determination

Similar documents
Research Article Prediction of Materials Density according to Number of Scattered Gamma Photons Using Optimum Artificial Neural Network

Evaluation of the Nonlinear Response Function and Efficiency of a Scintillation Detector Using Monte Carlo and Analytical Methods

CHAPTER 5 EFFECTIVE ATOMIC NUMBER OF SELECTED POLYMERS BY GAMMA BACKSCATTERING TECHNIQUE

Design, construction and characterization of a portable irradiator to calibrate installed ambient dose equivalent monitors

Neutronics Experiments for ITER at JAERI/FNS

Researchers at the University of Missouri-Columbia have designed a triple crystal

Compton suppression spectrometry

Digital Spectrometric System for Characterization of Mixed Neutron Gamma Field in the Experimental Reactor LR-0

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

CHAPTER 4 NUCLEONIC GAUGES. B.D. Sowerby

Activities of the neutron standardization. at the Korea Research Institute of Standards and Science (KRISS)

Monte Carlo modelling of a NaI(Tl) scintillator detectors using MCNP simulation code

Characteristics of Filtered Neutron Beam Energy Spectra at Dalat Reactor

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Calculating standard captured spectra of formation elements

MC simulation of a PGNAA system for on-line cement analysis

Gamma-ray shielding of concretes including magnetite in different rate

Shielded Scintillator for Neutron Characterization

K 40 activity and Detector Efficiency

Neutron Shielding Properties Of Concrete With Boron And Boron Containing Mineral

Sample Spectroscopy System Hardware

An industrial radiography exposure device based on measurement of transmitted gamma-ray intensity

VERIFICATION OF MONTE CARLO CALCULATIONS OF THE NEUTRON FLUX IN THE CAROUSEL CHANNELS OF THE TRIGA MARK II REACTOR, LJUBLJANA

Validation of the MCNP computational model for neutron flux distribution with the neutron activation analysis measurement

OXEA - Online Elemental Analyzer

A Monte Carlo Simulation for Estimating of the Flux in a Novel Neutron Activation System using 252 Cf Source

ITU-Nuclear Safeguards and Security Unit

Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools

5. Gamma and neutron shielding characteristics of concretes containing different colemanite proportions

Measurement of Shielding Effectiveness of Building Blocks against 662 KeV Photons

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

in Cross-Section Data

Design of a Compact Neutron Detector with Flat Response in Energy Range from 5-20 MeV

Monte Carlo simulation for the estimation of iron in human whole blood and comparison with experimental data

An introduction to Neutron Resonance Densitometry (Short Summary)

Detection efficiency of a BEGe detector using the Monte Carlo method and a comparison to other calibration methods. Abstract

A MONTE CARLO SIMULATION OF COMPTON SUPPRESSION FOR NEUTRON ACTIVATION ANALYSIS. Joshua Frye Adviser Chris Grant 8/24/2012 ABSTRACT

Fundamentals of Radionuclide Metrology

CALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo

Characterization of the 3 MeV Neutron Field for the Monoenergetic Fast Neutron Fluence Standard at the National Metrology Institute of Japan

Nuclear techniques in mineral exploration, extraction, and processing

Radionuclide Imaging MII Positron Emission Tomography (PET)

The Neutron Diagnostic Experiment for Alcator C-Mod

Chemical Engineering 412

Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays

Evaluate Shielding Design of the Brachytherapy Unit by Using Monte Carlo Simulation Code

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

Compton Camera. Compton Camera

Journal of Radiation Protection and Research

International Atomic Energy Agency International Society of Tracers and Radiation Applications. Patrick BRISSET

Collimated LaBr 3 detector response function in radioactivity analysis of nuclear waste drums

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

Progress in Nuclear Science and Technology, Volume 6,

Neutron and Gamma Ray Imaging for Nuclear Materials Identification

Neutron Generation from 10MeV Electron Beam to Produce Mo99

Induced photonuclear interaction by Rhodotron-TT MeV electron beam

at Oak Ridge National Laboratory.

anti-compton BGO detector

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Applications of MCBEND

MCNP analysis and optimization of a double crystal phoswich detector

K 40 activity and Detector Efficiency

Evaluation of Geometric Progression (GP) Buildup Factors using MCNP Codes (MCNP6.1 and MCNP5-1.60)

A Germanium Detector with Optimized Compton Veto for High Sensitivity at Low Energy

Measurement of Average Thermal Neutron Flux for PGNAA Setup

EEE4106Z Radiation Interactions & Detection

Efficiency. Calculations for Selected Scintillators. > Detector Counting. Efficiency. > Photopeak Efficiency of Various Scintillation Materials

Journal of Radiation Protection and Research

Development of a Dosimetric System using Spectrometric Technique suitable for Operational Radiation Dose Measurements and Evaluation

Investigation Of The Effects Of Variation Of Neutron Source-Detector Distance On The Emitted Neutron Dose Equivalent

Calibration of EJ-301, a Liquid Scintillator

Characterization and Monte Carlo simulations for a CLYC detector

SOME POSSIBLE APPLICATIONS OF MEASUREMENTS ON MU MESONS TO NUCLEAR SAFEGUARDS, NONPROLIFERATION, AND ARMS CONTROL ACTTVinES

SCINTILLATION DETECTORS AND PM TUBES

Journal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article

Atoms, Radiation, and Radiation Protection

IAEA-TECDOC Technical data on nucleonic gauges

Nuclear cross-section measurements at the Manuel Lujan Jr. Neutron Scattering Center. Michal Mocko

MONTE-CARLO SIMULATIONS OF TIME- RESOLVED, OPTICAL READOUT DETECTOR for PULSED, FAST-NEUTRON TRANSMISSION SPECTROSCOPY (PFNTS)

DETERMINATION OF CORRECTION FACTORS RELATED TO THE MANGANESE SULPHATE BATH TECHNIQUE

WM2018 Conference, March 18-22, 2018, Phoenix, Arizona, USA. PVT and LaBr3(Ce)-based Radon Express Analyzers 18164

Gamma-Spectrum Generator

High Energy Neutron Scattering Benchmark of Monte Carlo Computations

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory

Project Memorandum. N N o. = e (ρx)(µ/ρ) (1)

Monte Carlo Calculations Using MCNP4B for an Optimal Shielding Design. of a 14-MeV Neutron Source * James C. Liu and Tony T. Ng

Basic hands-on gamma calibration for low activity environmental levels

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

Detection of explosives and fissile material based on neutron generators, survey of techniques and methods. M. Bruggeman

arxiv: v1 [physics.ins-det] 9 Apr 2018

Comparison of the Photo-peak Efficiencies between the Experimental Data of 137 Cs Radioactive Source with Monte Carlo (MC) Simulation Data

Week 7: Ch. 10 Spec. w/ Scintillation Ctrs. Photomultiplier Devices

P7 Radioactivity. Student Book answers. P7.1 Atoms and radiation. Question Answer Marks Guidance

International Journal of Scientific Research and Reviews

Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data

Dr. Tuncay Bayram. Sinop University Department of Nuclear Energy Engineering Sinop, Turkey.

MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT

Fast-Neutron Production via Break-Up of Deuterons and Fast-Neutron Dosimetry

Tandem Collimators System

Transcription:

International Journal of Innovation and Applied Studies ISSN 2028-9324 Vol. 4 No. 2 Oct. 2013, pp. 408-412 2013 Innovative Space of Scientific Research Journals http://www.issr-journals.org/ijias/ An Optimized Gamma-ray Densitometry Tool for Oil Products Determination Amirmohammad Beigzadeh 1, Hossein Afarideh 1, Eskandar Asadi Amirabadi 2, Zahra Soltani 1, and Gholam Reza Etaati 1 1 Energy Engineering and Physics Department, Amir Kabir University of Technology, Tehran, Iran 2 Department of Physics, Payam-e-Noor University, Tehran, Iran Copyright 2013 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. ABSTRACT: Gamma-ray densitometry or nucleonic gauges have been widely used in industries to improve the quality of products, optimize processes and save energy and materials. Compared with common time-consuming and expensive chemical analyses, the proposed method is relatively fast and more reliable. Density measurement is normally based on the absorption of gamma radiation as it passes through the process material. The absorption which is proportional to the changes in material density indicates product density as the measuring path is held constant. In this study, a number of Monte Carlo simulations have been performed using the MCNP-4C code to optimize the arrangement of gamma densitometer. The dimensions of the proposed system have been chosen to coincide with the industrial specimen of gamma densitometer. The geometry of source to detector in different angles was investigated and optimized angles were chosen. The simulation as well as experimentally measurements has been performed for 4 different fluids including water, gasoline and diesel engine oil used with iron and PVC pipes of 4 inches diameter. The gamma source and detector have been a 137 Cs and NaI(Tl) scintillation detector. Our experiments and simulations results show that the transmission mode present, better results than the scattering one in densitometer. The single detector response of the detector located at 180 can distinguish the gasoil, gasoline and water densities. By optimized counting time and source-detector geometry, the densities of above mentioned fluids within the precision of 0.1 g/cm 3 were achieved. KEYWORDS: Gamma-ray Densitometry, MCNP-4C, Oil Products, Measurements, scintillation detector. 1 INTRODUCTION Simple nucleonic gauges (NCS) first began to be used in industry over forty years ago. Since then, there has been a continuous expansion in their usages. The competition from alternative methods shows that the nucleonic gauges have survived and prospered in the past because of their superiority in certain areas to conventional methods. The success of NCS is due primarily to the ability conferred by their unique properties, to collect data, which cannot be obtained by other investigative techniques [1]. Density measurement has found important applications in various industries, such as oil and gas productions, mining and mineral ore processing, environmental monitoring, paper and plastics industries, cement and civil engineering industries, where the benefit is enormous and the technology competes effectively with conventional techniques. The observed trends and new developments include the use of Monte Carlo simulations for design optimization, calibration and data processing [1], [2], [3]. There are basically three main categories of nucleonic gauges used in industry: Corresponding Author: Amirmohammad Beigzadeh (beigzadeh_am@yahoo.com) 408

Amirmohammad Beigzadeh, Hossein Afarideh, Eskandar Asadi Amirabadi, Zahra Soltani, and Gholamreza Etaati (1) Transmission gauges used to measure the density, thickness, etc. In these gauges the source housing and the detector are on opposite sides of the material and the radiation is attenuated as it travels through the material. (2) Backscatter gauges used to measure the thickness of coatings, well logging, etc. Here, the detector and source housing are on the same side of the material and therefore the detector has to be shielded from the primary radiation. The radiation enters the material, interacts with it and scatters back out. (3) Reactive gauges (e.g., used for elemental analysis). In these gauges, certain low-energy gamma and X-ray sources cause fluorescent X-ray emissions in the material being investigated [1]. In this paper, the optimum position of detector toward source has been determined using the Mont Carlo simulations, and then the corresponding experimental set-ups have been prepared to verify the simulation results. 2 METHODS Density measurement is normally based on the absorption of gamma radiation as it passes through the process material. The absorption which is proportional to the changes in material density indicates product density as the measuring path is held constant. With several detectors installed over the same pipe cross-section both transmitted and scattered radiation, the measurements can be performed in several positions. Basically, the energy of scattered photons depends on the scattering angle. Therefore, there is a relationship between the detected radiation energy/ intensity, and the distribution of oil and gas inside the pipe. A Monte Carlo simulation model has been developed and implemented in order to compare the accuracy of both transmitted and scattered photons over the pipe line. 3 RESULT AND DISSCUSION 3.1 SIMULATIONS VS. EXPERIMENTS MCNP is a general purpose Monte Carlo code for calculating the time-dependent, continuous energy, neutrons, photons and electron transports in three dimensional geometries [4]. A number of benchmark studies have been published using the Monte Carlo transport code, MCNP [5], [6]. Here, two simulation models according to the nucleonic gauges including the transmitted and back scattered ones, have been developed to measure the density of fluids as shown in Figure 1. It seems necessary to develop a model for the simulated one to locate the detectors, on the basis of the sensitivity of densitometer. In the case of water, gasoil and gasoline, 11 simulations have been performed, in which the detector angle ranges from 40 to 180 around the pipe with a 0.5 mci 137 Cs gamma source. The choice of the gamma-ray source depends on the characteristics of the experiment such as the pipe material, pipes body thickness, diameter, detection sensitivity, and shielding considerations. The 662 kev gamma-rays from the 137 Cs source easily pass through the pipe wall materials, and therefore the uncertainties due to the counting statistics can be reduced. The densities of typical water, gasoil and gasoline at 30 C under laboratory conditions are 0.920, 0.720 and 0.820 g/cm 3, respectively. The tally F8 of the MCNP code has been considered as the detector pulse-height equivalent and hundreds of millions of computer runs have been performed for source particles. The final experiments setups were found to be consistent with the obtained results at simulation. Fig. 1. Different configuration setups of density measurement system. ISSN : 2028-9324 Vol. 4 No. 2, Oct. 2013 409

An Optimized Gamma-ray Densitometry Tool for Oil Products Determination Figs. 2 and 3 show the detector count rates for several positions around the pipe for both scattering and transmission measurements for PVC and iron pipes, respectively. As it can be seen, when the detector is located at the 3 specific angles (150,170,180 degrees), the highest count rates are obtained a procedure which determines the optimum detector position. The average counts for the detector located at 40, 60, 80, 90, 110 and 130 represent very small values only concerning the scattered photons detected in these angles. Therefore, the transmitted method has more sensitivity than the scattered one that means the transmitted-based gauges can determine and control the material density in the pipe more accurately. The single detector response of the detector located at 180 can distinguish the gasoil, gasoline and water densities with the accuracy of 0.1 g/cm 3. Fig. 2. Count rate vs. detector angle for iron pipe (MCNP simulation) Fig. 3. Count rate vs. detector angle for PVC pipe (MCNP simulation) Furthermore, as it can be seen in Figs. 4 and 5, the agreement between the experimental and simulation results is excellent. A small difference between the two curves may be partly corresponded to (1) the fact that the detector has not been fully simulated, (2) the background count rate variations and also (3) the environmental conditions. However, one may conclude that the MCNP code is an efficient tool for the simulation of nuclear gauging instruments. ISSN : 2028-9324 Vol. 4 No. 2, Oct. 2013 410

Amirmohammad Beigzadeh, Hossein Afarideh, Eskandar Asadi Amirabadi, Zahra Soltani, and Gholamreza Etaati Fig. 4. Count rate versus detector angle for iron pipe (Experiment) Fig. 5. Count rate versus detector angle for PVC pipe (Experiment) Straight angle as the optimum detector position was selected for designing and setting up experiment. the experiment and simulations were performed for gasoil pipe using mentioned densitometer. 4 CONCLUSION Our experiments and simulations results show that the transmission mode present, better results than the scattering one in densitometer. Based on the both MCNP4C code simulation and our experimental results, fluid densitometer device can be developed for industrial applications to distinguish the material with similar densities from one another with the accuracy of 0.1 g/cm 3 REFERENCES [1] International Atomic Energy Agency (IAEA), Technical data on nucleonic gauges, IAEA Publications, IAEA-TECDOC-1459, July 2005. ISSN : 2028-9324 Vol. 4 No. 2, Oct. 2013 411

An Optimized Gamma-ray Densitometry Tool for Oil Products Determination [2] G.A. Johansen, P. Jackson, Radioisotope Gauges For Industrial Process Measurements, John Wiley & Sons, West Sussex, England, 2004. [3] M. Maucec and I. Denijs, Development and calibration of a gamma-ray density meter for sediment-like materials, Applied Radiation and Isotopes, vol. 67, pp. 1829 1836, 2009. [4] J. F. Briesmeister, MCNP Monte Carlo N-Particle Transport Code System, Los Alamos, National Laboratory, 2002. [5] M. Sohrabpour, M. Hassanzadeh, M. Shahriari and M. Sharifzadeh, Gamma irradiator dose mapping simulation using the MCNP code and benchmarking with dosimetry, Applied Radiation and Isotopes, vol. 57, pp. 537 542, 2002. [6] M. Sohrabpour, M. Shahriari, V. Zarifan, K.K. Moghadam, Borehole prompt gamma neutron activation and comparison with Monte Carlo simulation using MCNP code: Borehole PGNAA experiment comparison with MCNP, Applied Radiation and Isotopes, vol. 50, pp. 805 810, 1999. ISSN : 2028-9324 Vol. 4 No. 2, Oct. 2013 412