Calibration and Monitoring for Crystal Calorimetry

Similar documents
Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

Precision Crystal Calorimetry in High Energy Physics: Past, Present and Future

Large Size LYSO Crystals for Future High Energy Physics Experiments

Precision Crystal Calorimetry in High Energy Physics

Precision CMS PWO Crystal ECAL

LSO/LYSO Crystal Development Ren-yuan Zhu

IN the last decade, cerium doped silicate based heavy

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

Fast Crystal Scintillators for Future HEP Experiments

THE main physics motivation for building the Compact

The Next Generation of Crystal Detectors

REVIEW OF CRYSTAL CALORIMETERS

A Study on Radiation Damage in PWO-II Crystals

Crystal Technologies for LC

Inorganic Scintillators

The CMS ECAL Laser Monitoring System

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

INORGANIC crystal scintillators are widely used in high

The BaBar CsI(Tl) Electromagnetic Calorimeter

Crystal calorimeters in the next decade

Crystals for the HHCAL Detector Concept Rihua Mao, Member, IEEE, Liyuan Zhang, Member, IEEE, and Ren-Yuan Zhu, Senior Member, IEEE

Il Calorimetro Elettromagnetico di CMS

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 55, NO. 4, AUGUST /$ IEEE

Highlights from the 9 th Pisa Meeting on Advanced Detectors Calorimetry Session

M. Diemoz INFN Sezione di Roma, P.le A. Moro 2, Roma, Italy

BSO Crystals for the HHCAL Detector Concept

Introduction to scintillators

Measurement of Transmittance, Emission and Light Output for PWO Crystals

Performance of the CMS electromagnetic calorimeter during the LHC Run II

Radiation Induced Color Centers and Light Monitoring for Lead Tungstate Crystals

Calibration of the CMS Electromagnetic Calorimeter with first LHC data

Forward Calorimetry Ideas

The BABAR Electromagnetic Calorimeter: Status and Performance Improvements

Scintillating crystals for calorimetry and other applications.

Searches for New Physics in Photonic Final States at the LHC with CMS

NEW TYPES OF LEAD TUNGSTATE CRYSTALS WITH HIGH LIGHT YIELD

arxiv:physics/ v1 22 Dec 2003

CMS ECAL status and performance with the first LHC collisions

Upgrade of the CMS Forward Calorimetry

Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run 2

Case study: The Lead Tungstate Calorimeter for CMS

Fast Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon PIN Diodes and APDs

Scintillation Detectors

LHCb Calorimetry Impact

Calorimetry in particle physics experiments

Summary on crystal damage from hadrons

CLEO c. Anders Ryd Cornell University June 7, e e cc D D. D K,D K e

8 Calibration and Monitoring

Luminosity Calorimeter Technologies

Scintillation detectors

Dual readout with tiles for calorimetry.

Time of Flight measurements with MCP-PMT

Scintillators for photon detection at at medium energies

2.5 Physics of the Universe, Astrophysics, Nuclear Planetology Dark Matter and Double Beta Decay Study Planetary Nuclear

Commissioning and Calibration of the Zero Degree Calorimeters for the ALICE experiment

LHC (ATLAS & CMS)

Studies of Hadron Calorimeter

05 - Scintillation detectors

Tracker material study with the energy flow through the CMS electromagnetic calorimeter. Riccardo Paramatti, Ambra Provenza

Studies on the e + e - spectrum with the first data of the CMS experiment at the Large Hadron Collider

High-efficiency and fast-timing scintillators

The PRIMEX Experiment: A Fundamental Test of the Chiral Anomaly Prediction in QCD. Erik Minges April 23 rd, 2010

The CsI(T1) C a 1 orimeter of the BABAR Detector*

ATLAS Hadronic Calorimeters 101

The fast light of CsI(Na) crystals

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

Calorimetry at LHC. Arno Straessner TU Dresden. Graduiertenkolleg Masse, Spektrum, Symmetrie DESY Zeuthen October 4-8, 2011

Fast inorganic scintillators - status and outlook -

Interconnecton. Lecture 8: Department of Physics and Astronomy

Current Status of Luminosity Measurement with the CMD-3 Detector at the VEPP-2000 e + e collider

CHIPP Plenary Meeting University of Geneva, June 12, 2008 W. Lustermann on behalf of the AX PET Collaboration

Calorimetry I Electromagnetic Calorimeters

Hadronic Calorimetry

Hadronic Calorimetry

A. Physics of the electromagnetic cascade 6. B. Energy resolution of electromagnetic calorimeters Stochastic term

Interaction of particles in matter

First light from. Gagan Mohanty

PoS(PD07)001. Photodetectors in High Energy Physics. Abstract

New Results from the DREAM project

Physics at Hadron Colliders

PUBLISHED BY IOP PUBLISHING FOR SISSA MEDIALAB

Recent results at the -meson region from the CMD-3 detector at the VEPP-2000 collider

Development of a High Precision Axial 3-D PET for Brain Imaging

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

Optical transmission radiation damage and recovery stimulation of DSB:Ce 3+ inorganic scintillation material

Electromagnetic calorimeters of the CMD-3 detector

Introduction. Tau leptons. SLHC. Summary. Muons. Scott S. Snyder Brookhaven National Laboratory ILC Physics and Detector workshop Snowmass, Aug 2005

Accelerator Based Particle Physics Experiments

LC Muon System R & D

Physics with Jets at the LHC

Study of Transitions and Decays of Bottomonia at Belle

Measurements of e + e hadrons at VEPP-2M

Top Physics at CMS. Intae Yu. Sungkyunkwan University (SKKU), Korea Yonsei University, Sep 12 th, 2013

Applications of Cerium-Doped Gadolinium Silicate Gd 2 SiO 5 :Ce. Scintillator to Calorimeters in High Radiation Environment

e + e - (1) Silicon Vertex Detector

Detection methods in particle physics

Search for high mass resonances in the diphoton and Zγ channels at LHC

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007

ATLAS Tile Calorimeter Calibration and Monitoring Systems

Transcription:

Calibration and Monitoring for Crystal Calorimetry CsI(Tl) Ren-yuan Zhu CALTECH BGO PWO SCINT03 Valencia, Spain

Properties of Crystal Scintillators Crystal NaI(Tl) CsI(Tl) CsI BaF 2 BGO PbWO 4 LSO(Ce) GSO(Ce) Density (g/cm 3 ) 3.67 4.51 4.51 4.89 7.13 8.3 7.40 6.71 Melting Point (ºC) 651 621 621 1280 1050 1123 2050 1950 Radiation Length (cm) 2.59 1.85 1.85 2.06 1.12 0.9 1.14 1.37 Molière Radius (cm) 4.8 3.5 3.5 3.4 2.3 2.0 2.3 2.37 Interaction Length (cm) 41.4 37.0 37.0 29.9 21.8 18 21 22 Refractive Index a 1.85 1.79 1.95 1.50 2.15 2.2 1.82 1.85 Hygroscopicity Yes Slight Slight No No No No No Luminescence b (nm) (at peak) 410 560 420 310 300 220 480 560 420 420 440 Decay Time b (ns) 230 1300 35 6 630 0.9 300 50 10 40 60 Light Yield b,c (%) 100 45 5.6 2.3 21 2.7 9 0.1 0.6 75 30 d(ly)/dt b (%/ ºC) ~0 0.3-0.6-2 ~0-1.6-1.9?? Experiment Crystal Ball CLEO BaBar BELLE KTeV (L*) (GEM) TAPS L3 BELLE CMS ALICE BTeV - - a. at peak of emission; b. up/low row: slow/fast component; c. measured by PMT of bi-alkali cathode. 2

SM Physics with Crystal Calorimetry Charmonium System Observed Through Inclusive Photons Charmed Meson in Z Decay Crystal Ball 3

New Physics with Crystal Calorimetry Higgs Search at LHC SUSY Breaking with Gravitino CMS 4

New Physics with Crystal Calorimetry (cont.) The CDF event: 2 e + 2 + E miss T SM expectation (WW ) ~ 10-6 (PR D59 1999) Possible SUSY explanation qq e ~ + e ~ ~ GG - 0 0 ee~ ~ ~ 1 1 ee L3 should be able to observe e + e ~ GG - 0 0 ~ ~ ~ 1 1 Another possible channel e + e - 0 0 0 0 ~ ~ ~ ~ 2 2 1 1 5

KTeV CsI Position Resolution 3256 CsI Sub mm position resolution is achievable. L3 BGO & CMS PWO: 0.3 mm at high energies. 6

CLEO & BaBar : CsI(Tl) Degradation CLEO: ~15 % over 12 years BaBar : 1 3 % per year Brian Heltsley (http://www.lns.cornell.edu/~bkh) Endcap crystals re-glued for CLEOIII Jan 1990 CLEO III Lab Test 7

CLEO CsI(Tl) Calibration With Bhabha Electrons & Photons from π 0 s Brian Heltsley (http://www.lns.cornell.edu/~bkh) CLEOIII CLEOII Energy resolution M JJ (GeV) 8

BaBar CsI(Tl) Calibration By using a γ ray source at 6.13 MeV, Bhabha electrons and photons from π 0 s M. Kocian, SLAC, CALOR2002 0.03-3 3 GeV 3-99 GeV, 12h 0.00613 GeV, 1/2h 6580 CsI(Tl) Crystal Calorimetry at Low Energies 9

L3: BGO Degradation L3: BGO transmittance degrades 6 7% in 7 years, measured by a Xenon light monitoring system -pulsed light from Hamamatsu L2453 Xenon lamps; - two fibers per crystal crystal; - response normalized to reference photo detectors. 10

BGO Quality Improvement Z.Y. Wei et al., Nucl. Instr. and Meth. A302 (1991) 69. No change in decay time by Eu doping: 0, 5, 30, 100 ppm Recovery after 2.5 krad Significant Improvement in radiation hardness by Eu doping 11

L3 RFQ Calibration System An accelerator & a Li target provide 17.6 MeV γ rays e- H- Ion Source RFQ, HEBT Neutralizer Beam Pipe Li Target 12

L3 BGO Calibration With 17.6 MeV γ ray from RFQ and Bhabha Electrons Contribution Radiative +Intrinsic Temperature Calibration Overall Barrel 0.8% 0.5% 0.5% 1.07% Endcaps 0.6% 0.5% 0.4% 0.88% 12k BGO 13

PWO Light Output Variation Damage and Recovery Causes Complication 14

PWO Radiation Damage Radiation induced absorption caused by color center formation, but no damage in scintillation mechanism 15

CMS ECAL Monitoring System Initial calibration on test beam (as much crystals as possible) In situ calibration with physics ( W e + n, Z e + e - ): using E/p allows an inter-calibration of 0.5% in 35 days at low luminosity. Monitoring evolution of crystal response by light injection system DATA LINK DATA LINK PWO ADC & OPTO FPPA or MGPA APD CTRL OPTO SERIALIZER ADC ( x 12) Four wavelengths from laser to be distributed to 80 super-modules, then to 77k PWO. F1 PN FE F2 S Laser 440 nm 495 nm 709 nm 796 nm 16

Monitoring Wavelength Determination '(T) versus '(LY) Sensitivity and Linearity o 440 nm is chosen for the best linearity 17

Lasers at CERN for PWO Monitor 2003 2001 2001 The 1 st laser system was Installed in 2001, and used in 2002 beam test. The 2 nd and 3 rd laser systems installed at CERN in August, 2003. 18

Ti:Sapphire Laser with Two Wavelengths Nd:YLF Pump Tunable Ti:S 19

History: Laser Pulse Energy & r.m.s. Short term r.m.s 1.7%, or 15 uj. Peak to peak variation 15%, corresponding to overall r.m.s. 3.7%. Specification: r.m.s. <10%. Drifting caused by power supply, temperature: air condition needed. 20

Experiences in 2002 Beam Test The same slope during damage & recovery 21

PWO Resolution With Light Monitoring Before/after beam irradiation: 10% variation in light output 22

Expected CMS PWO Resolution Beam Test 77k PWO Crystal Calorimetry at High Energies Designed Resolution 23

Summary Because of the total absorption, crystal calorimetry provides good resolution for electron and photon measurement, and thus excellent physics potential. To reach its physics potential, good radiation resistance of crystal scintillators is crucial for crystal calorimetry. Mass produced crystals, however, may suffer from radiation damage, which may have to be taken care of by a light monitoring system and precision calibration in situ with physics. 24