arxiv: v1 [physics.ins-det] 29 Jun 2011

Similar documents
arxiv: v1 [physics.ins-det] 7 Dec 2018

Compton Camera. Compton Camera

Radionuclide Imaging MII Positron Emission Tomography (PET)

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

III. Energy Deposition in the Detector and Spectrum Formation

Particle Energy Loss in Matter

Detector Physics of Resistive Plate Chambers

CHAPTER 5 EFFECTIVE ATOMIC NUMBER OF SELECTED POLYMERS BY GAMMA BACKSCATTERING TECHNIQUE

Study on Surface Asperities in Bakelite-RPC

Particle Energy Loss in Matter

Response uniformity of a large size RPC

A Complete Simulation of a Triple-GEM Detector

arxiv: v1 [physics.ins-det] 3 Jun 2016

Quantitative Assessment of Scattering Contributions in MeV-Industrial X-ray Computed Tomography

PoS(RPC2012)034. Simulation studies on the Effect of SF 6 in the RPC gas mixture

DETECTORS. I. Charged Particle Detectors

EEE4106Z Radiation Interactions & Detection

08 - Miscellaneous and historical detectors

CHIPP Plenary Meeting University of Geneva, June 12, 2008 W. Lustermann on behalf of the AX PET Collaboration

Researchers at the University of Missouri-Columbia have designed a triple crystal

ON THE OMNIPRESENT BACKGROUND GAMMA RADIATION OF THE CONTINUOUS SPECTRUM

Space Charge Effects in Resistive Plate Chambers

Calorimetry I Electromagnetic Calorimeters

Energy resolution and absolute detection efficiency for LSO crystals: a comparison between Monte Carlo simulation and experimental data

Simulation of GEM-TPC Prototype for the Super-FRS Beam Diagnostics System at FAIR

7. Particle identification

Detectors in Nuclear and High Energy Physics. RHIG summer student meeting June 2014

What detectors measure

Final report on DOE project number DE-FG07-99ID High Pressure Xenon Gamma-Ray Spectrometers for Field Use

Space charge limited avalanche growth in multigap resistive plate chambers

A complete simulation of a triple-gem detector

Last Lecture 1) Silicon tracking detectors 2) Reconstructing track momenta

Advances in PET technology

Simulation study of scintillatorbased

Understanding RPC Efficiencies And The Cross-talks

RPCs and applications to the Particle Physics

Development of a High Precision Axial 3-D PET for Brain Imaging

A Monte Carlo Study of the Relationship between the Time. Structures of Prompt Gammas and in vivo Radiation Dose in.

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

Novel detector systems for the Positron Emission Tomography

arxiv:physics/ v1 3 Aug 2006

Position Sensitive Germanium Detectors for the Advanced Compton Telescope

Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data

Detector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples

Performance of a triple-gem detector for high-rate particle triggering

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Positron Emission Tomography based on Resistive Plate Chambers

Digital Imaging Calorimetry for Precision Electromagnetic and Hadronic Interaction Measurements

arxiv: v1 [physics.ins-det] 3 Feb 2011

arxiv: v2 [physics.ins-det] 15 Apr 2016

Study of the Neutron Sensitivity for the Double Gap RPC of the CMS/LHC by Using GEANT4

Chemical Engineering 412

New Versatile Platform Based on the Low Energy Electron Beam Delivered by the PHIL Photoinjector

Results on long-term performances and laboratory tests of the L3 RPC system at LEP

Nuclear Instruments and Methods in Physics Research A

PHYS 3313 Section 001 Lecture #7

Radiation Detection and Measurement

PoS(EPS-HEP2015)232. Performance of a 1 m 2 Micromegas Detector Using Argon and Neon based Drift Gases

THREE-QUANTA POSITRON ANNIHILATION IN BLOOD SAMPLES OF DIFFERENT OXYGENATION LEVELS

arxiv: v1 [physics.ins-det] 22 Dec 2013

DEVIL PHYSICS THE BADDEST CLASS ON CAMPUS IB PHYSICS

Experimental Particle Physics

Experimental Particle Physics

Positron Emission Tomography

PHY492: Nuclear & Particle Physics. Lecture 25. Particle Detectors

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Measurement of the transverse diffusion coefficient of charge in liquid xenon

The cosmic ray muon tomography facility based on large scale MRPC detectors

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

A MONTE CARLO SIMULATION OF COMPTON SUPPRESSION FOR NEUTRON ACTIVATION ANALYSIS. Joshua Frye Adviser Chris Grant 8/24/2012 ABSTRACT

Hands on LUNA: Detector Simulations with Geant4

RATE CAPABILITY OF A HIGH EFFICIENCY TRANSITION RADIATION DETECTOR

General Overview of Gas Filled Detectors

Muon reconstruction performance in ATLAS at Run-2

Experimental Particle Physics

Inorganic Scintillators

Transition Radiation Detector for GlueX

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

Geant4 simulations of the lead fluoride calorimeter

PoS(HCP2009)042. Status of the ALICE Experiment. Werner Riegler. For the ALICE Collaboration. CERN

& SUN ZhiJia 1;2. Abstract

Compact Muon Solenoid Surapat Ek-In École Polytechnique Fédérale de Lausanne

Detecting high energy photons. Interactions of photons with matter Properties of detectors (with examples)

Basic physics Questions

A novel design of the MeV gamma-ray imaging detector with Micro-TPC

An underground cosmic-ray detector made of RPC

A liquid xenon PET camera - Simulation and position sensitive PMT tests

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Mayneord-Phillips Summer School St Edmund Hall, University of Oxford July Proton decays to n, e +, ν

Offline Data Processing of MRPC End cap

Scintillation Detectors

Physics sources of noise in ring imaging Cherenkov detectors

THE MULTIGAP RESISTIVE PLATE CHAMBER. Abstract

β and γ decays, Radiation Therapies and Diagnostic, Fusion and Fission Final Exam Surveys New material Example of β-decay Beta decay Y + e # Y'+e +

Examples for experiments that can be done at the T9 beam line

Timing and Energy Response of Six Prototype Scintillators

Information about the T9 beam line and experimental facilities

The GILDA mission: a new technique for a gamma-ray telescope in the energy range 20 MeV GeV

PANDA Muon System Prototype

Transcription:

Performance simulation of a MRPC-based PET Imaging System arxiv:1106.5877v1 [physics.ins-det] 29 Jun 2011 A. Banerjee, S. Chattopadhyay April 16, 2018 Abstract The low cost and high resolution gas-based Multi-gap Resistive Plate Chamber (MRPC) opens a new possibility to find an efficient alternative detector for Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the system depends largely on the time resolution of the detector. Suitable converters can be used to increase the efficiency of detection of photons from annihilation. In this work, we perform a detailed GEANT4 simulation to optimize the converter thickness thereby improving the efficiency of photon conversion. Also we have developed a Monte Carlo based simulation of MRPC response thereby obtaining the intrinsic time resolution of the detector, making it possible to simulate the final response of MRPC-based systems for PET imaging. The result of the cosmic ray test of a four-gap Bakelite-based MRPC operating in streamer mode is discussed. 1 Introduction Under Nuclear Medicine, Positron Emission Tomography(PET) is an important imaging technique in which a radio-pharmaceutical having positron emitter is injected into the object of study. This radioactive element can be used to collect the morphological information from the object. Inside the object, these positrons annihilate with the available electrons to produce two nearly back-toback photons each having energy of 511 kev. The simultaneous detection of these photons with efficient detectors can lead to the identification of annihilation point. As these positron emitters are injected via some physiological substances, mapping of the density of the positron sources can give the information about the activity inside the object of interest. Although PET gives various important information which the other imaging techniques are not able to provide, limitations due to a short field of view (FOV)( 16 cm in standard PET scanners), long dead time of the electronics among others affect the sensitivity and the spatial resolution of the currently available PET scanners. Moreover, to obtain an image, in a reasonable examination time a high radiation dose is required to deliver within the object to collect sufficient amount of data. In a Time-of-Flight (TOF) PET scanner, the arrival times of each coincident pair of photons are more precisely known, and the (extremely small) difference between them is used to localize the annihilation event along the line between 1

the two detected photons. This additional TOF information helps to improve the image quality by reducing the length over which the coincident events are back-projected. Instead of being back-projected over the entire distance through the body, the events are back-projected over a smaller distance, determined by the timing resolution of the scanner. For example, for a coincidence timing resolution of 600 ps the positional uncertainty is 9 cm Full Width at Half Maximum along the line pair. The average diameter of a typical patient (torso) is 25-30 cm, or approximately three times the TOF positional uncertainty. The ratio of patient diameter (D) to the positional uncertainty ( x) has been reported to be representative of the noise reduction, or the sensitivity gain, with TOF. This benefit in TOF increases as the PET system timing resolution improves. The detectors that are generally used worldwide for PET imaging are the scintillator-based detectors, e.g., Bismuth germanate (BGO) or Lutetium orthosilicate (LSO), as they have excellent light output and very good energy resolution. But because of its high cost and the above-said limitations, several attempts are being made to find an alternative. Multi-gap Resistive Plate Chambers (MRPCs) are considered to be a good alternative to the scintillatorbased PET imaging systems because of their excellent time resolution ( 50 ps) and position ( 1 mm) resolution in addition to the relatively lower cost of fabrication. In MRPC-based system, the location of the origin of photons can be obtained in 3-dimensions. The detector cell provides the position in transverse plane (x-y plane) and the time of arrival on the detector gives the distance in z-direction. If the time resolution of the MRPC is known then an estimation of the spread for the position of origin of photon source can be obtained by the formula [1]: L[mm] σ t [ps]/2 (1) where L is the FWHM in the position accuracy and σ t is the rms time accuracy per photon. Reconstruction of events however improves the resolution therby producing the desired image granularity (few mm). Several attempts have been made in building MRPC-based prototype PET imaging systems using varying number of gaps. However, like many other gasbased detector systems, the efficiency of conversion of 511 kev photons is very low. MRPC, due to its layered structure, has a natural configuration where proper conversion materials can be placed to obtain better efficiency. However, very thick converter will likely to absorb the produced electrons before they can reachthe gasvolume, whereasfor very thin one it is very difficult to have a good conversion efficiency. Efforts have been made to optimize the converter-mrpc combination for obtaining best possible efficiency of single 511 kev photon detection. A maximum value up to 20-25% has been reported, as mentioned in Ref [1, 4]. In this work, we have performed a detailed simulation to optimize the detection efficiency of a pair of 511 kev photons likely to be generated from positron annihilation. The work includes the response of the passage of the photons inside the material by GEANT4 and a Monte-Carlo (MC) based simulation package for obtaining the MRPC signals giving their timing properties due to produced electrons. The simulation is done in two stages. First, GEANT4 has been used to simulate the conversion of the incident photons. The electrons obtained by photon conversion are considered to be the particles ionizing the 2

gas. The processes for ionization to signal generation have been implemented in another MC code. We organize the article as follows. In Sec. 2, we discuss the simulation procedure, in Sec. 3 we give the results obtained from the simulation and in Sec. 4 we present the results of the performance of a four gap Bakelite-base MRPC, operated in streamer mode. 2 Simulation Procedure 2.1 Conversion of 511 kev photons GEANT4 (version 4.9.4) has been used to simulate the response of photons through the detector thereby generating electrons which reach the gas volume. GEANT4 [6, 7] is the efficient toolkit where different aspects of simulation process, such as the geometry of the system, the materials involved, the generation of secondary particles, the tracking of particles through materials, the physics processes governing particle interactions, the response of sensitive detector components,etc. can be implemented. For gamma ray conversion, the data file G4EMLOW version 6.19, containing cross-sections for low energy electromagnetic processes, was used. The photon-pairs are considered to be back to back lying on the same plane. For attaining good conversion efficiency, we have used a set of Lead-MRPC combinations as shown schematically in Fig. 1. Two such combinations are placed facing each other considering the source of photon-pair to be in between as shown in Fig. 1. In this work, as an input of GEANT4, we have used different materials including lead as the converter, glass as detector material and the mixture C 2 F 4 H 2 /i-c 4 H 10 /SF 6 (85/5/10) as the gas volume in the gas gap. We have studied the variation of the conversion efficiency by varying the converter thickness. Figure 1: Schematic representation of the detector configuration Two photons with momenta of same magnitude(511 kev) but opposite directions are used as the input for every event. Any particle (photon or electrons) backscattered from one detector to the other are not considered for further 3

study. Photons get converted mainly in the lead volume mostly by the Compton and the photoelectric processes [1, 2]. A number of low energy electrons get absorbed inside the lead volume. Only the electrons reaching any one of the gas volume are considered for signal generation. Increasing the number of Pb- MRPC combinations improves the conversion probability, which subsequently decreases due to the absorption of electrons. The conversion efficiency of each detector is defined as the ratio of the number of the photons that generate electrons after conversion in any of the gas gaps to the number of the incident photons. 2.2 Monte Carlo study for response of MRPC The conversion electrons resulting from GEANT4 are used as the input to the Monte-Carlo based programme, developed to study the response in the gas volume for signal generation. When the electron passes through the gas volume it ionizes the gas, which leads to the avalanche formation. During primary ionization the average number of clusters formed into the gas mixture is considered to be around nine/0.2 mm [2], which is the higher for slow electrons from converted photons than the value commonly used for minimum ionizing particles for the gas of given composition. The avalanche development from the primary cluster within the gas volume is governed by the Townsend coefficient (α) and the attachment coefficient (η), which in this work are simulated by HEED [8]. The probability to obtain n avalanche electrons at position x within the gas volume, considering the electrode to be at x=0, is given by the relation [9] P(n,x) = k n(x) 1 n(x) k, n = 0 2 1 k = n(x)( n(x) k ) ( n(x) 1 n 1 n(x) k ), n > 0 (2) where n(x) = e (α η)x and k = η α. To reduce the computational time in avalanche formation by a large number of secondary electrons, in our case for n(x) > 200, we have used the Central Limit Theorem (CLT), as mentioned in Ref [9], to obtain the average number of electrons and their spread after avalanche at a particular position. The space charge effect is also implemented by the application of a cut off on the number of avalanche electrons, after which multiplication stops. In the present case, the threshold applied is 1.6 10 7. Finally the avalanche electrons induce current signals onto the MRPC pick-up strips. The particle is said to be detected if the induced charge crosses a threshold value, which is 20 fc in our case. The detection efficiency of the MRPC, in this work, is defined as the ratio of the number of particles crossing the threshold charge value to the number of converted particles entering the gas gap. The concept of multi-gap has been implemented within the MC code by introducing a number of sub-gaps, keeping the total width of the gas volume same. During this study, we have simulated the detection efficiency and the time response of MRPC for varying number of gaps. No effort has been made to implement the response of the readout electronics. We have defined the avalanche growth time as the time taken by the avalanche, starting from time t=0, to 4

produce sufficient number of electrons within the gas volume so that it can induce a charge greater than 20 fc to the MRPC electrodes. The standard deviation of the distribution of the avalanche growth time taken over a large number of particles is called the time resolution(tr) of the detector for single photon. For a pair of detectors, facing each other, as shown in Fig. 1., the difference of the time (t 1 ) taken by one photon to produce a detectable avalanche in one detector and the time (t 2 ) taken by the other photon to produce the same in another detector is defined as the pair time difference [δt = t 1 t 2 ]. The standard deviation of pair time difference taken over a large number of photon pairs is defined as pair time resolution (PTR) for pair of photons. For the case, when both the detectors are equally spaced from the point of origin of the photon pair, PTR is governed mainly by the folding of TR of two detectors. 3 Simulation Results 3.1 Efficiency of photon conversion The conversion efficiency is already defined in the previous section. Fig. 2. shows the conversion efficiency over the number of gas gap, where we have varied the converter thickness. By increasing the number of gaps, the effective 35 30 0.0008 cm 0.002 cm 0.004 cm 0.008 cm 0.01 cm conversion efficiency(%) 25 20 15 10 5 0 0 20 40 60 80 100 120 140 160 180 number of combinations Figure 2: Conversion efficiency as a function of number of gaps thickness increases. It is seen clearly that with increasing number of gaps, the conversion efficiency increases. However for larger thickness, e.g. 0.1 mm, etc., the efficiency does not go higher than 18% thereby suggesting the converted electrons to stop inside the lead volume. Use of thinner converter in large numbers however increases the efficiency even further. The plot indicates that an efficiency 25% can be achieved with a configuration having 120 gaps, the converter thickness being 0.002 cm. From the plot it can be seen that the converter having thickness 0.0008 cm is also giving an impressive conversion efficiency beyond 140 layers. A saturation of the conversion efficiency for more 5

than 140 gaps is observed for almost all the converter thickness studied. It is of utmost importance to optimize the converter thickness for having a good conversion efficiency. During all through our study we have considered the optimized converter thickness as 0.004 cm. Fig. 3. indicates the photon conversion efficiency with the configuration prescribed earlier for different materials each having the same thickness of 0.004 cm. The plot clearly indicates that lead is the most suitable converter for 511 kev photons for 0.004 cm thickness of the converter layer. conversion efficiency(%) 30 25 20 15 10 5 Lead Tungsten Aluminium Copper Graphite 0 0 20 40 60 80 100 120 140 160 180 200 220 number of gaps Figure 3: Conversion efficiency as a function of number of gaps We therefore conclude that a suitable tuning of converter material and thickness can help to achieve reasonable conversion efficiency in a multi-gap configuration. 3.2 Time response for MRPC In Fig. 4. we have plotted the distribution of the signal collection time for single photon incident on the detector having 20 gas gaps as obtained from MC simulation for MRPC response. The total number of entries in this plot indicate the total number of the particles after conversion. The time resolution (σ) is found to be 17 ps, which is in good agreement with earlier results [10]. The pair time resolution was calculated considering the start time to be zero. Fig. 5. shows the distribution of the pair time difference collected from both the detectors. The standard deviation of the plot, 24 ps in this case, has a good agreement with the fact that both the detector have the same intrinsic time resolution. We have observed the effect of the number of gaps in time resolution by varying the number of the gas gaps, keeping the total width of the gas gap to be the same. It is seen that the time resolution decreases with the number of gas gaps. 6

Figure 4: Time resolution of the detector 600 500 400 count 300 200 100 0-400 -200 0 200 400 Time(ps) Figure 5: Pair time resolution for both the detectors 3.3 Estimation of the position resolution for an extended source of photon pairs Inthis work,wehavealsoestimatedthe positionresolutionofthe detectorinthe prescribed configuration for an extended annihilation source. For this purpose, we have introduced a Gaussian spread of the source position in one direction, e.g., in z-direction keeping mean at zero and sigma of 0.5 mm. The photon pairs are back to back on same plane. We have then obtained the corresponding time difference measured by the pair of detectors. In Fig. 6. we have plotted the ratio of the distance of the source from the origin to the corresponding measured time difference. The spread gives an estimation of the resolution of the position measurement. In this case the time of detection of a photon by the detectors is the sum of the time taken by the photon to reach the detector from the point of its origin and the signal generation time for each detector. It should be mentioned that the contribution from the second plays the leading role in the spread of the 7

Figure 6: Ratio of the diatance of the point of generation for the origin to the photon detection time by the system detection time. 4 Performance of the prototype MRPC The RPC technology mentioned in[11, 12] was used to build a four-gap Bakelitebased MRPC. Bakelite plates of 30 cm 30 cm in dimension and thickness of 1.2 mm had been used as electrodes and a uniform spacing of 0.6 mm each had been maintained by a high resistive material G-10 (resistivity 10 13 Ω-cm). A mixture of Ar/i-butane/Freon(R134a) in the ratio of 55/7.5/37.5 was used as the working gas. A very thin coating of Silicone has been applied on the inner surfaces of the Bakelite plates to improve the surface roughness. The detector has been operated in streamer mode as it gives larger signal size and does not need any preamplifier. The detector has been tested with cosmic muons using the signals from three scintillators for trigger. Even though for these application, glass-based detectors operating in avalanche mode are usually used, the performance of 4-gap Bakelite-based detector will provide the lower limit of resolution for a least expensive option of background filtering PET imaging. Fig. 7. shows the efficiency as a function of the high voltage. An efficiency plateau 95% had been obtained for an applied high voltage greater than 13.5 kv. The distribution of the time difference between the master trigger and the signal from one MRPC strip is shown in Fig. 8. From the time difference spectrum, the full width at half maximum (FWHM) and the corresponding standard deviation (σ ij ), where i and j refer to scintillators and the MRPC, were obtained by fitting a gaussian function. σ ij s were similarly obtained for 3 different pairs of the scintillators, taking START signal from one and STOP signal from the other. The intrinsic time resolutions of the MRPC and the scintillators were obtained from the individual standard deviations σ i, σ j, which were extracted by solving the equation: σ ij 2 = σ i 2 +σ j 2. The variation of FWHM and the time delay for the MRPC is shown in Fig. 8

Figure 7: Efficiency as a function of applied voltage Figure 8: Distribution of the time difference between the MRPC and the master trigger 9. The extracted time resolution (σ) of the MRPC at 14 kv operating voltage for a typical run was found to be 870 ± 0.03 ns. 5 Conclusions and outlook MRPC-based PET sysytem is potentially an attractive alternative to the scintillatorbased sysytem. In this work we have performed detailed simulation for the detection of photon pairs for MRPC-based system. A layered structure of MRPC with thickness 0.004 cm lead converter can give conversion efficiency greater than 25%, which is higher compare to normally available values for gas detector 9

Figure 9: Time resolution and time delay as a function of applied voltage systems. For a 20 gap system, time resolution of photon pair can reach upto 17 ps. We have also performed simulation for the position measurement for an extended source of 500 µm width and found that the spread of the photon source can be measured with the addition of 3.17% extra fluctuation. This suggests the appreciability of thse systems for measurements of photon-pair position to micron level. As an effort to obtain a least expensive PET imaging system capable of filtering the background, we have built a 4-gap Bakelite-based MRPC giving time resolution of 900 ps. For applications requiring relatively lower resolution, such a system can be useful. This also provides a platform to build a full glass-based high resolution MRPC system for PET imaging. 6 Acknowledgement The authors gratefully acknowledge the technical contributions from Mr. G. Das and Mr. J. Kumar and also acknowledge Dr. S. Biswas, Dr. T. Ghosh and Dr. Sanjay Pal for their help in detector test as well as in the simulation. References [1] A. Blanco et al., Nucl. Instr. and Meth. A 508 (2003) 88. [2] C. Lippmann et al., Nucl. Instr. and Meth. A 602 (2009)735. [3] M. Abbrescia et al., Nucl. Instr. and Meth. A 593 (2008) 263. [4] A. Blanco et al., Nucl. Instr. and Meth. A 478 (2002) 170. [5] A. Blanco et al., Nucl. Instr. and Meth. A 580 (2007) 915. 10

[6] S. Giani, et al., GImage 4: An object-oriented toolkit for simulation in HEP, CERN/LHCC 98-44, 1998, GImage 4 Web page: http://cern.ch/geant4. [7] See Physics Reference Manual at the GImage 4 Web page [1] under Documentation. [8] W. Blum, L. Ronaldi, Particle Detection with Drift Chambers, Springer, Berlin, 1993 ISBN3-540-56425-X. [9] W.Riegler, et al.,nucl. Instr. and Meth. A 500 (2003) 144. [10] S. An, et al., Nucl. Instr. and Meth. A 594 (2008) 39. [11] S. Biswas, et al., Nucl. Instr. and Meth. A 604 (2009) 310. [12] S. Biswas, et al., Nucl. Instr. and Meth. A 602 (2009) 784. 11