Effective Detection of Buried Radioactive Waste

Similar documents
Field Tests of a NaI(Tl)-Based Vehicle Portal Monitor at Border Crossings

WM2011 Conference, February 27 - March 3, 2011, Phoenix, AZ

Neutron Detector Gamma Insensitivity Criteria

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

Radioactivity. Lecture 6 Detectors and Instrumentation

Utilization of advanced clutter suppression algorithms for improved spectroscopic portal capability against radionuclide threats

Efficient Algorithms for Pulse Parameter Estimation, Pulse Peak Localization And Pileup Reduction in Gamma Ray Spectroscopy M.W.Raad 1, L.

Characterising NORM hazards within subsea oil and gas facilities. Daniel Emes SA Radiation

Scintillation Spectroscopy for Detection of Depleted Uranium

GAMMA RAY SPECTROSCOPY

Gamma ray coincidence and angular correlation

1 of :32

The Best Gamma-Ray Detector

ORTEC AN34 Experiment 10 Compton Scattering

ANGLE 4. Advanced Gamma Spectroscopy Efficiency Calibration Software

Detection and measurement of gamma-radiation by gammaspectroscopy

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

Comparison of Several Detector Technologies for Measurement of Special Nuclear Materials i

New Approach to Gamma Scans for Processed Natural Uranium at a FUSRAP Site 15470

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

Modifying Voice Activity Detection in Low SNR by correction factors

First tests of the big volume ultra low background gamma spectrometer

Compton suppression spectrometry

Measurement of Specific Activities of Some Biological Samples for Some Iraq Governorates

A Modular NMF Matching Algorithm for Radiation Spectra

Collimated LaBr 3 detector response function in radioactivity analysis of nuclear waste drums

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

SCIENCE CHINA Physics, Mechanics & Astronomy

ABSTRACT. Radiation portal monitor (RPM) systems are currently deployed in many countries

An Improved U-Pu System for Field Pu Measurements

Gamma Spectroscopy. References: Objectives:

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

Enriched Uranium Waste Assay at AWE

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Terrestrial gamma dose rates along one of the coastal highways in Sri Lanka

AIR FORCE INSTITUTE OF TECHNOLOGY

JRPR. The Development of Gamma Energy Identifying Algorithm for Compact Radiation Sensors Using Stepwise Refinement Technique.

Minimum Detectable and Maximum Missable Activities

ADVANCED SYNTHETICALLY ENHANCED DETECTOR RESOLUTION ALGORITHM: A SYSTEM FOR EXTRACTING PHOTOPEAKS FROM A SODIUM IODIDE SCINTILLATION DETECTOR SPECTRUM

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

U.S. EPA Superfund Counts Per Minute (CPM) Electronic Calculator Stuart A. Walker. U.S. Environmental Protection Agency, Washington, DC.

Gamma-Ray Spectroscopy Measurement of Depleted Uranium in Soil

Frazier L. Bronson CHP Canberra Industries, Inc., Meriden, CT USA ABSTRACT

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

THE COMPTON EFFECT Last Revised: January 5, 2007

Radioactivity and Radioactive Decay

in Cross-Section Data

Radiation Detection and Measurement

1 Introduction. 2 Method. Robert Metzger 1,*, Kenneth Van Riper 2, and George Lasche 3

Computational study to enhance threat detection of radiation portal monitors:

XA TERRESTRIAL GAMMA DOSE RATE MAPS, THEIR COMPILATION AND VERIFICATION RADIOMETRIC MAP OF THE CZECH REPUBLIC

Compton Imaging with Coincidence Measurements for Treaty Verification Purposes

Minimum Detectable Activity Estimates for a Germanium-Detector Based Spectroscopic Portal Monitor

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

RADIOECOLOGICAL PROBLEMS IN HOME BUILDING IN THE CITY OF NOVI SAD

Alpha spectrometry systems. A users perspective. George Ham. 26 th May Date Month Year

SCINTILLATION DETECTORS AND PM TUBES

arxiv: v3 [physics.ins-det] 13 Dec 2016

Contrabands detection with a low energy electron linac driven photoneutron source

X ray Imaging Android [XIA]

Report on the GC-MBS Method or Correcting NaI Spectra for Transmission Loss in Hand-Held Instruments

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

WM2018 Conference, March 18-22, 2018, Phoenix, Arizona, USA. PVT and LaBr3(Ce)-based Radon Express Analyzers 18164

Monte-Carlo Simulation of Response Functions for Natural Gamma-Rays in LaBr 3 Detector System with Complex Borehole Configurations

GERDA Meeting, September 2009, LNGS. News from Low-Level-Lab: Attempt to Reduce Neutron Background at Shallow Depths

Identification of Naturally Occurring Radioactive Material in Sand

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Acronyms, Abbreviations, and Symbols Foreword to the First Edition Foreword to the Second Edition Preface to the First Edition Preface to the Second

In-Situ Evaluation and Calibration of Radioisotope Cones in Singapore Marine Clays

Sample Spectroscopy System Hardware

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Applied Nuclear Science Educational, Training & Simulation Systems

5) Measurement of Nuclear Radiation (1)

Recent improvements in on-site detection and identification of radioactive and nuclear material

QuantumMCA QuantumNaI QuantumGe QuantumGold

DEVELOPMENT OF A REAL-TIME DETECTION STRATEGY FOR MATERIAL ACCOUNTANCY AND PROCESS MONITORING DURING

Quality Assurance. Purity control. Polycrystalline Ingots

General Overview of Radiation Detection and Equipment

Analyzing Radiation. Pre-Lab Exercise Type of Radiation Alpha Particle Beta Particle Gamma Ray. Mass (amu) 4 1/2000 0

GM Pancake Probe Victoreen Model D

Screens for low current beams

List of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide

ENERGY PEAK STABILITY WITH COUNT RATE FOR DIGITAL AND ANALOG SPECTROMETERS

Key words: Gamma ray, Radioactivity, NOR, Abeokuta

Actinides in Human Urine by Alpha Pulse Height Analysis (PHA)

Investigation of depleted uranium contamination in south west of Iraq

Special Nuclear Material Detection Studies With The SMANDRA Mobile System

PROFILE S and C Series

1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer

Pete Burgess, Nuvia Limited. Clearance and exemption

Monitoring of Ionizing Radiations facilities Experience and challenge

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies AUTOMATED QA/QC CHECK

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

Efficiency. Calculations for Selected Scintillators. > Detector Counting. Efficiency. > Photopeak Efficiency of Various Scintillation Materials

Neutron Based Techniques for the Detection of Illicit Materials and Explosives

ARTICLE IN PRESS. Applied Radiation and Isotopes

Spectral Analysis for the High Efficiency Multimode Imager

Development of a Characterized Radiation Field for Evaluating Sensor Performance

Transcription:

WM9 Conference, March -5, 9, Phoenix, AZ Effective Detection of Buried Radioactive Waste - 995 Qian Du, Nicolas H. Younan, Charles Waggoner, Donna Rogers Department of Electrical and Computer Engineering Institute for Clean Energy Technology Mississippi State University, MS 3976, USA ABSTRACT A method based on matched filtering is developed to detect buried depleted uranium. It does not require background information and its performance is robust under very low-count conditions. Based on lab data experiments using a 4cm NaI detector and FIDLER detector, this approach can easily detect a 5mm penetrator with g mass buried 3cm deep with a detector dwell time as short as.s. This method can be easily implemented in near real-time to provide immediate response in critical situations. INTRODUCTION Depleted uranium (DU) is considered both a toxic and radioactive hazard. Effectively detecting DU is of great importance. DU can be detected using gamma spectroscopy collected from sodium iodide (NaI) scintillation detectors, e.g, a 4cm NaI detector and a FIDLER (Field Instrument for the Detection of Low Energy Radiation) detector, due to unique spectral features presented []. A NaI detector can be used as a radiation portal monitor (RPM) for border screening []. Traditionally, detection can be achieved by calculating the ratio between the counts at the energy levels of interest [3-7]. More advanced approaches include gross-count material basis set (GC-MBS) model [8-], energy windowing method [-], spectral comparison ratio with spectrum correction [3], and principal component analysis-based method [4]. When DU is buried, energy counts can be very low. The performance of the aforementioned methods may be limited. In our research, we employ a more advanced signal processing algorithm based on matched filtering to detect buried DU. First, important features are extracted from the gamma spectroscopy collected when the penetrator is located on the surface; then, a matched filter-based detector is applied to the spectrum when the penetrator is buried using the extracted features. This approach has three major advantages: ) there is no background information that is required (as long as the Gamma spectrum when the penetrator is on the surface is known); ) there is a correlation between the output of the matched filter and the mass of depleted uranium (in other words, the mass of depleted uranium may be retrieved from a multiple regression analysis); and 3) fast and near real-time implementation can be achieved to provide immediate response in critical situations. In practical surveys, the dwell time of a detector in each specific location may be very short. In other words, the energy counts captured by the detector may be much smaller than in the case

WM9 Conference, March -5, 9, Phoenix, AZ when the dwell time is long enough. This requires the algorithm be robust under very low-count conditions. Lab data collected by a 4cm NaI detector and a FIDLER detector with short dwell time are used in the experiments. The preliminary results demonstrate the effectiveness of the proposed approach for buried DU detection. APPROACH In communication and signal processing, a matched filter is obtained by correlating (i.e., convolving) a known signal template with an unknown signal to detect the presence of the desired template. The matched filter is the optimal linear filter for maximizing the signal to noise ratio (SNR) in the presence of additive random noise [5]. Let an observed signal x be expressed as the desirable signal s and additive noise n, i.e., x = s + n. () Let a finite impulse response (FIR) filter be represented by h. The filter output is y = h T x = h T s + h T n. () The objective is to design a filter h such that the SNR of the filter output, defined as T T h s h s SNR = = (3) T T E h n h Rnh is maximized such that the detection of s can be achieved, where E ( ) denotes the operation of statistical expectation and R n is the noise correlation matrix. The solution of this optimization problem is h = R s. (4) n When the signal s has low energy, the data correlation matrix R can be used to replace without noise estimation, i.e., h = R s. (5) The key of the success of the matched filter is to choose an appropriate signal template as s. In this research, the s will be part of the energy spectrum that distinguishes the DU from other radioactive materials and background. R n EXPERIMENTS We present two experiments using lab data, one collected by a 4cm NaI detector and the other by a FIDLER detector. The major purpose is to demonstrate the effectiveness of the proposed matched filter approach in the detection of buried DU and the discrimination from the background (soil and sand) and natural ore. Another purpose is to investigate its robustness when dealing with the data collected with short detector dwell time (i.e., s,.5s,.s). Two penetrators were used in the experiments: a 5 mm penetrator with 4.3kg mass and a 5mm penetrator with g mass.

WM9 Conference, March -5, 9, Phoenix, AZ 4cm NaI Detector For each dwell time, six energy spectra were studied: DU on the surface, DU buried 5cm deep, 3cm deep, 3cm deep, natural ore, and background. The energy spectrum from 6 kev to kev when the DU is on the surface are considered as the feature used in the matched filter. This spectral region is referred to as region of interest (ROI). Figures and show the detailed energy spectra and matched filter outputs for the six cases when the dwell time was s for the 5mm penetrator, where the ROIs were highlighted. It is obvious that when the DU was present, the output in ROI was strong and the outputs outside ROI were suppressed; when the DU was buried deep or absent, outputs inside and outside ROI became noisy. The SNR values of the outputs were calculated and listed in Table I, where we can see that even when the DU was buried 3cm deep, the output was still greater than the natural ore and background. The outputs were decreased when the dwell time was reduced to.5s and.s. It is worth mentioning that the SNR was estimated as the ratio between the square of the maximum output in ROI and the output variance in the rest of the spectrum. 9 8 7 6 5 4 3.5 -.5 - (a) original spectrum when DU on the surface - (b) matched filter output for (a) 9 8 7 6.5 5 4 3 -.5 - (c) original spectrum when DU buried 5cm deep - (d) matched filter output for (c)

WM9 Conference, March -5, 9, Phoenix, AZ 9 8 7 6 5 4 3.5 -.5 - (e) original spectrum when DU buried 3cm deep - (f) matched filter output for (e) 9 8 7 6.5 5 4 3 -.5 - (g) original spectrum when DU buried 3cm deep - (h) matched filter output for (g) Fig.. DU detection using a 4cm NaI detector (ROI is highlighted). Table I. Matched filter outputs for the NaI detector quantified with SNR in db Penetrator/Dwell time 5mm/s 5mm/.5s 5mm/.s Surface 79. 86.95 65.54 5cm depth 9.77 5.76 8.84 3cm depth 4.7 3.99 7.7 3cm depth 8.88.67 4.8 Natural ore.37.4.98 Background.9.9.7 FIDLER Detector Since the energy spectrum is different from the FIDLER detector, the feature used for the matched filter has to be changed. Here, the energy spectrum from kev to 5 kev when the DU is on the surface is considered as the feature, which is ROI in this case.

WM9 Conference, March -5, 9, Phoenix, AZ 9 8 7 6.5 5 4 3 -.5 - (a) original spectrum for natural ore - (b) matched filter output for (a) 9 8 7 6.5 5 4 3 -.5 - (c) original spectrum for background - (d) matched filter output for (c) Fig.. Detection when DU is absent using a 4cm NaI detector (ROI is highlighted). Figures 3 and 4 show the detailed energy spectra and matched filter outputs for the six cases when the dwell time was s for the 5mm penetrator, where the ROIs were highlighted. Once again, when the DU was present, the output in ROI was strong and the outputs outside ROI were suppressed; when the DU was buried deep or absent, outputs inside and outside ROI became very noisy. The SNR values were calculated and listed in Table II, where we can see that even when the DU was buried 3cm deep, the output was still greater than those of the natural ore and background. The outputs were decreased when the dwell time was reduced to.5s and.s, but they were still significantly larger for accurate detection. From Tables I and II, we can see that an appropriate threshold can be derived for a decision of detection based on the prior information of the responses from undesired materials and background.

WM9 Conference, March -5, 9, Phoenix, AZ 8 6 4 8 6 4 3(a) original spectrum when DU on the surface.5 -.5-3(b) matched filter output for 3(a) 8 6 4 8 6 4.5 -.5 3(c) original spectrum when DU buried 5cm deep - 3(d) matched filter output for 3(c) 8 6 4 8.5 6 4 -.5 3(e) original spectrum when DU buried 3cm deep - 3(f) matched filter output for 3(e)

WM9 Conference, March -5, 9, Phoenix, AZ 8 6 4 8 6 4.5 -.5 3(f) original spectrum when DU buried 3cm deep - 3(g) matched filter output for 3(f) Fig. 3. DU detection using a FIDLER detector (ROI is highlighted). 8 6 4 8 6 4 4(a) original spectrum for natural ore.5 -.5-4(b) matched filter output for 4(a) 8 6 4 8 6 4 4(c) original spectrum for background.5 -.5-4(d) matched filter output for 4(c) Fig. 4. Detection when DU is absent using a FIDLER detector (ROI is highlighted).

WM9 Conference, March -5, 9, Phoenix, AZ Table II. Matched filter outputs for the FIDLER detector quantified with SNR in db Penetrator/Dwell time 5mm/s 5mm/.5s 5mm/.s Surface 69.83 484.45 44.3 5cm depth 63.44 63.5 5. 3cm depth 48. 55.84 4.7 3cm depth 46.7 37.55 9.39 Natural ore 4.5 5.77 7.33 Background 9.6.9 4.87 CONCLUSION A matched filter-based method is investigated for the detection of buried DU. This approach requires only the spectrum feature in ROI when DU is placed on the surface, and it does not require the background information. The estimated SNR value can be employed as the threshold for decision-making. The preliminary result using lab data shows the effectiveness of this approach. Its performance on real field data needs to be studied in the future. ACKNOWLEDGMENT This research is supported by U.S. Army Engineer Research and Development Center at Vicksburg, Mississippi. The authors would like to thank Mr. Wei Wei and Ms. Sheng You for their help with computer coding and Mr. Steve Mann for his help with data collection. REFERENCES. G. F. KNOLL, Radiation detection and measurement, 3rd ed., Wiley, New York ().. E. R. SICILIANO, J. H. ELY, R. T. KOUZES, B. D. MILBRATH, J. E. SCHWEPPE, and D. C. STROMSWOLD, Comparison of PVT and NaI(Tl) scintillators for vehicle portal monitor applications, Nuclear Instruments and Methods in Physics Research A, 55: 647-674 (5). 3. S. ZUEHLKE, Comparison of scintillation detection efficiencies of depleted uranium wounds, Master Thesis, Colorado State University (997). 4. M. SHOJI, Y. HAMAJIMA, K. TAKATSUKA, H. HONOKI, T. NAKAJIMA, T. KONDO, and T. NAKANISHI, A convenient method for discriminating between natural and depleted uranium by γ-ray spectrometry, Applied Radiation and Isotopes, 55: -7 (). 5. D. J. KARANGELOS, M. J. ANAGNOSTAKIS, E. P. HINIS, S. E. SIMOPOULOS, and Z. S. ZUNIC, Determination of depleted uranium in environmental samples by gammaspectroscopic techniques, Journal of Environmental Radioactivity, 76: 95-3 (4). 6. H. YUCEL, The applicability of MGA method for depleted and natural uranium isotopic analysis in the presence of actinides, Applied Radiation and Isotopes, 65: 69-8 (7).

WM9 Conference, March -5, 9, Phoenix, AZ 7. I. BIKIT, J. SLIVKA, D. MRDJA, N. ZIKIC-TODOROVIC, S. CURCIC, E. VARGA, M. VESKOVIC, and L. CONKIC, Simple method for depleted uranium determination, Journal of Applied Physics, 4: 569-573 (3). 8. R. J. ESTEP, M. RAWOOL-SULLIVAN, and D. MIKO, A method for correcting NaI spectra for attenuation losses in hand-held instrument applications, IEEE Transactions on Nuclear Science, 45 (3): -8 (998). 9. D. MIKO, R. J. ESTEP, M. W. RAWOOL-SULLIVAN, An innovative method for extracting isotopic information from low-resolution gamma spectra, Nuclear Instruments and Methods in Physics Research A, 4: 433-437 (999).. M. W. RAWOOL-SULLIVAN, R. J. ESTEP, M. W. JOHNSON, W. MURRAY, Application of the gross-count material basis set (GC-MBS) method to the analysis of CdZnTe spectra, IEEE Transactions on Nuclear Science, 47 (4): 395-398 ().. J. H. ELY, R. T. KOUZES, B. D. GEELHOOD, J. E. SCHWEPPE, Discrimination of naturally occurring radioactive material in plastic scintillator material, IEEE Transactions on Nuclear Science, 5 (4): 67-676 (4).. J. H. ELY, R. KOUZES, J. SCHWEPPE, E. SICILIANO, D. STRACHAN, and D. WEIER, The use of energy windowing to discriminate SNM from NORM in radiation portal monitors, Nuclear Instruments and Methods in Physics Research A, 56: 373-387 (6). 3. D. M. PFUND, R. C. RUNKLE, K. K. ANDERSON, and K. D. JARMAN, Examination of count-starved Gamma spectra using the method of spectral comparison ratios, IEEE Transactions on Nuclear Science, 54 (4): 3-38 (7). 4. R. C. RUNKLE, M. F. TARDIFF, K. K. ANDERSON, D. K. CARLSON, and L. E. SMITH, Analysis of spectroscopic radiation portal monitor data using principal component analysis, IEEE Transactions on Nuclear Science, 53 (3): 48-43 (6). 5. G. L. TURIN, An introduction to matched filters, IRE Transactions on Information Theory, 6 (3): 3-39 (96).