LAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.)

Similar documents
SYNOPSIS OF CHANGES TO BC LABORATORY MANUAL, MARCH 2017

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3)

Measurement Uncertainty: A practical guide to understanding what your results really mean.

Appendix A. Glossary of Definitions, Acronyms, Abbreviations and Symbols. March 1997

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

Test Method: CPSC-CH-E

ALLOWAY METHOD OUTLINE

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)

Glossary of Common Laboratory Terms

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Understanding the Uncertainty Associated with Analytical Results: Sources, Control and Interpretation of Results. Marc Paquet, Chemist M.Sc.

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

Laboratory 101: A Guide to Understanding your Testing Laboratory

Seawater Extraction Procedure for Trace Metals

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Shaker Table Extraction

Data Glossary. Acceptance criteria - specific limits placed on characteristics of an item, process, or service defined in requirements documents.

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

APPENDIX II QUALITY CONTROL SUMMARY TABLES

3.1.1 The method can detect, identify, and potentially measure the amount of (quantify) an analyte(s):

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY.

METHOD 5000 SAMPLE PREPARATION FOR VOLATILE ORGANIC COMPOUNDS

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

CCME Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons (PHC) in Soil - Tier 1 Method

ACZ Laboratories, Inc Downhill Drive Steamboat Springs, CO (800)

EPAs New MDL Procedure What it Means, Why it Works, and How to Comply

U.S. EPA SW-846 Method 6010C Using the Prodigy7 High- Dispersion ICP Introduction. Application Note - AN1305. Experimental

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

EPA Office of Water Method Update Rule Final August 28, 2017 William Lipps October 2017

Putting the Pieces of the Puzzle Together. By Kim Kirkland, Methods Team Leader EPA s Office of Resource Conservation and Recovery

METHOD 8000A GAS CHROMATOGRAPHY

Polycyclic Aromatic Hydrocarbons in Water by GC/MS PBM

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Class III Wastewater Laboratory Analyst Examination Study Guide 2008

METHOD 3600C CLEANUP

Method Validation. Role of Validation. Two levels. Flow of method validation. Method selection

Application of Detection and Quantification Concepts to Chlorine Residual Measurements

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

Examples of Method Validation Studies Conducted in Different Economies

STANDARD OPERATING PROCEDURES

Results of the EPA Method 1631 Validation Study

Is the laboratory s pledge or declaration of the quality of the results produced. to produce data compliant with the Safe Drinking Water Act (SDWA)

Traceability, validation and measurement uncertainty 3 pillars for quality of measurement results. David MILDE

This procedure describes the monitoring activities in a laboratory quality control (QC) program to ensure the quality of test results.

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Analysis of BTEX in Natural Water with SPME

Volatile Hydrocarbons (VH) in Waters by GC/FID

Standard Operating Procedure VUSP M

METHOD 3600B CLEANUP

Method Validation and Accreditation

Standard Operating Procedure for the Analysis of Dissolved Inorganic Carbon CCAL 21A.1

Z/zs. tnitiats: wu\ Z-z* I A. sop-c-102. Determination of Chemical Oxygen Demand. Revision 6. Approval: Effective date: 3. Renewat date: 7lt:,:

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

Laboratory Techniques 100: Back To Basics. Carol Injasoulian Lab Manager City of Bay City April 29,2015

APPENDIX G ESTIMATION OF UNCERTAINTY OF MEASUREMENT

TNI Standard; EL-V1M4 Sections and (Detection and Quantitation) page1 of 8. TNI Standard VOLUME 1 MODULE 4

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

Samples compliant with the WATER

Section A LABORATORY QUALITY ASSURANCE/QUALITY CONTROL. Her Majesty the Queen in Right of the Province of British Columbia 2007 All Rights Reserved.

TNI V1M Standard Update Guidance on Detection and Quantitation

VOTING DRAFT STANDARD

Appendix: Laboratory Testing Methods

Proposed Procedures for Determining the Method Detection Limit and Minimum Level

APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY

Update on ASTM and Standard Methods method development activities

ALLOWAY STANDARD OPERATING PROCEDURES FOR METHOD 504.1/8011

Laboratory Quality Control Report: Why is it Important?

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Certificate of Analysis

SeCtiOn 5 [STOCK AND CUSTOM] Assurance. Multi-Element CLP Standards

PCB Congener Analysis of XAD-2 Resins and GFF Filters Using GC/ECD

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

ACCURACY is the nearness of a result or the mean of a set of results to the true or accepted value.

EPA's Revision to the 40 CFR Part 136 Method Detection Limit (MDL) Procedure

Analytical Performance & Method. Validation

Review and Reporting of Chemical of Concern (COC) Concentration Data Under the TRRP Rule (30 TAC 350)

Manual stack emissions monitoring Performance Standard for laboratories carrying out analysis of samples

Analysis of domestic sludge using the Agilent 4200 MP-AES

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

Appendix A - Test Methods Method 301--Field Validation of Pollutant Measurement Methods from Various Waste Media

Sample RM Analytical Report ( B) HPLC/UV Analysis Acetaldehyde, Acrolein, Crotonaldehyde, Formaldehyde

Timberline Ammonia-001. Determination of Inorganic Ammonia by Continuous Flow Gas Diffusion and Conductivity Cell Analysis

Water Quality Reporting Limits, Method Detection Limits, and Censored Values: What Does It All Mean?

NATIONAL ASSOCIATION OF TESTING AUTHORITIES (NATA) REQUIREMENTS FOR ACCREDITATION OF ICP-MS TECHNIQUES

Fast Analysis of Chlorinated Phenoxy Herbicides in Environmental Samples by Negative ESI LC-MS/MS 14337

SAB Soil Vapour Forum July 8, Overview of Soil Vapour Assessment From A Laboratory Industry Perspective

LOUISVILLE CHEMISTRY GUIDELINE (LCG)

CHEM Experiment Five Gas Chromatographic Analysis Of A Phenolic Extract. Objectives:

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

Certificate of Analysis

Transcription:

LAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.) SOP-316 391 S. Vidal St., Sarnia, Ontario, N7T 7L1 Phone: (519) 344-4747 Fax: (519) 344-2350 E-Mail: info@lambtonscientific.com Method No: SOP-316 Effective Date: October 3, 2002 Revision No.: 1.0 Approved By: A. Schmidtmeyer Method Author: M. Scaini ISO/IEC 17025 (E): D. Newman Copy No.: _ of 4 A. Schmidtmeyer Glossary Definitions / Terms / QC Equations SCOPE / PURPOSE: This glossary is to define common terms used, and establish consistent nomenclature or terminology use throughout the laboratory. The following is also a compilation of terms and equations used in quality control calculations. This list is not to be considered exhaustive, but instead should be viewed as a work in progress. Terms and definitions will be added by future revisions etc. Some terms/definitions may be method specific and will be defined within the framework of a specific procedure. GLOSSARY: AAS: Atomic Absorption Spectroscopy ACCURACY: A measure that reflects the closeness of a measured value to its true value. (1) ASTM: American Society for Testing and Materials. ATG: Analytical Test Group, as defined by MISA. (2) ANALYTE: The chemical species (i.e. metal, anion, or organic) to be identified and quantified. BATCH: A group of samples processed together, at the same time, through each step of an analytical procedure. (2) BIAS: Consistent deviation of measured values from the true value, caused by systematic errors in a procedure. (1) B = ( x s x u ) K i.e. B = (50.8 45) 5 5.8 5 = 0.8 x s = measured value of spiked sample x u = measured value of unspiked sample K = known value of the spike in the sample BLANK: See Calibration Blank, Method Blank. BTEX: Benzene, Toluene, Ethylbenzene, (ortho, meta and para)- Xylenes BTEXS: BTEX plus Styrene CAEAL: Canadian Association of Environmental Analytical Laboratories. 1 of 6

SOP-316 CALIBRATION BLANK: Deionized water that has been acidified to the same level as found in the standards and samples. The calibration blank serves as the rinse solution between samples and standards. Also used for all initial and continuing calibration blank determinations. (3) CALIBRATION CURVE: A plot of concentrations for known analyte standards versus the instrument response to the analyte. Calibration standards are typically prepared which cover the working, linear range of the instrument. The calibration standards should be prepared using the same type of acid or solvent and at the same concentration as will result in the samples following sample preparation. (3) COMPOSITE SAMPLE: A final sample made up from a collection of sub-samples or grab samples that have been combined volumetrically or gravimetrically through automatic or manual means. (2) CONTINUING CALIBRATION VERIFICATION (CCV): A calibration standard used to verify continuing calibration. Used to assure calibration accuracy during each analysis run. It must be run for each analyte as described in the particular analytical method. At a minimum, it should be analyzed at the beginning of the run and after the last analytical sample. Its concentration should be at or near the mid-range levels of the calibration curve. (3) CERTIFIED REFERENCE MATERIAL (CRM): A matrix sample containing analytes at concentration values which have been certified by multiple laboratory analysis. CSA: Canadian Standards Association CVAAS: Cold Vapour Atomic Absorption Spectroscopy. DATA VALIDATION: The process of evaluating the available data against established quality criteria. DE-IONIZED WATER: Water that has been purified, with no detectable concentration of the analyte to be measured, at the detection limit of the analytical method. Water that is free of interfering analytes and / or contaminants. ECD: Electron Capture Detector. EXTERNAL REFERENCE STANDARD (EXT REF): A certified or independently prepared standard / solution used to verify the accuracy of the initial calibration. It is also known as the INITIAL CALIBRATION VERIFICATION (ICV) standard. (3) FID: Flame Ionization Detector FIELD DUPLICATES: Independent samples which are collected as close as possible to the same point in space and time. They are two separate samples taken from the same source, stored in separate containers, and analyzed independently. These duplicates are useful in documenting the precision of the sampling process. (3) GC: Gas Chromatography GC-MS: Gas Chromatography - Mass Spectrometry. GFAAS: Graphite Furnace Atomic Absorption Spectroscopy. GLP: Good Laboratory Practices. GRAB sample: Volume of effluent of at least 100 ml (except for volatiles) collected over a period not exceeding 15 minutes and immediately transferred to an appropriate laboratory sampling container. (2) IC: Ion Chromatography. 2 of 6

SOP-316 ICP-AES: Inductively Coupled Plasma - Atomic Emission Spectroscopy. INTERNAL STANDARD (IS): Quantitation analyte added to each sample or sample extract/digestate prior to sample analysis. Internal standards should mimic the analytes of interest but not interfere with the analysis. (1) ISE: Ion Selective Electrode. HPLC: High Performance (Pressure) Liquid Chromatography. LIMIT OF DETECTION (LOD): The point (typically a concentration) at which a measured value is larger than the uncertainty with which it can be measured. The LOD is set at a concentration that gives a signal that is 3 times the standard deviation (SD) of the measurement process at zero concentration or 3xSD 0 (~ MDL). (4) LIMIT of QUANTITATION (LOQ): The lowest concentration at which a result can have a meaningful uncertainty assigned to it. The LOQ is set at a concentration that gives a signal that is 10 times the standard deviation (SD) of the measurement process at zero concentration or 10xSD 0 (~ 3.33 x MDL). (4) LINEAR DYNAMIC RANGE: The concentration range over which the analytical curve remains linear. (3) MATRIX: The physical environment (e.g., water, soil, gas, hydrocarbon), which contains the analyte of interest. MATRIX SPIKE: An aliquot of sample spiked with a known concentration of target analyte(s). The spiking occurs prior to sample preparation and analysis. A spiked sample is used to document the bias of a method in a given sample matrix. (1) % Recovery = ((Measured spike value - sample value) / known spike concentration added) x 100% METHOD BLANK: An analyte-free matrix to which all reagents are added in the same proportions as specified in the analytical procedure under sample processing. The method blank should be carried through the complete sample preparation and analytical procedure. The method blank is used to document contamination resulting from the analytical process. (3) METHOD DETECTION LIMIT (MDL): Is a statistically defined decision point such that the measured results (from an analytical method) falling at or above this point are interpreted to indicate the presence of analyte in the sample with a specified probability (99 % confidence level). (2) MIDES: MISA Data Entry System. (2) MISA: Municipal and Industrial Strategy for (Pollution) Abatement. MOE document. (2) MOE: Ontario Ministry of Environment. (2) NIST: National Institute for Standards and Technology. NRC: National Research Council of Canada. P&T: Purge and Trap. PAH: Polynuclear Aromatic Hydrocarbon. PCBs: Polychlorinated Biphenyls 3 of 6

SOP-316 PRECISION: The agreement among a set of replicate measurements without assumption of knowledge of the true value. Precision is estimated by means of replicate analyses. The most commonly used estimates of precision are Relative Standard Deviation (RSD). (1) QUALITY ASSURANCE (QA): A definitive plan for laboratory operation that specifies the measures used to produce data of known precision and bias. (2) QUALITY CONTROL (QC): A set of measures within a sample analysis methodology to assure the process is in control. (2) QMS Quality Management System. RCRA: The Resource Conservation and Recovery Act (USEPA). REAGENT GRADE: Analytical reagent (AR) grade, ACS reagent grade, and reagent grade are synonymous terms for reagents that conform to the current specifications from the Committee on Analytical Reagents of the American Chemical Society. (3) RELATIVE STANDARD DEVIATION (RSD): RSD = 100% x ( x S ), where x = the arithmetic mean of xi measurements, and S = standard deviation. REPLICATE: Separate aliquots of sample taken from the same container and analyzed independently. RESPONSE FACTORS (RF): Is the ratio of the measured analyte (x) response (area (A) or height) for a given analyte and its corresponding concentration. RF(x)= A x / C x RMDL: Reporting Method Detection Limit. The RMDL is the maximum allowable value for a Laboratory MDL (LMDL) under the Effluent Monitoring and Effluent Limits Regulations. (2) SAMPLE STORAGE TIME: Period of time between sample collection and initiation of sample analysis. (2) SCC: Standards Council of Canada. SIGNIFICANT FIGURES: Is the number of digits that are known accurately, plus one that is uncertain or doubtful. For example, a balance indicating 13.0234g, the first 5 digits are known accurately, but the last number is doubtful. (5) SOP: Standard Operating Procedure. SPIKED BLANK: Reagent water spiked with compound(s) representative of the target analytes and carried through the preparation and analysis procedure as a sample. This is used to document method performance.(1) SRI (SMALLEST REPORTING INCREMENT): MDL/3 and then rounded down to the nearest 1, 2 or 5. (2) SRM (STANDARD REFERENCE MATERIAL): Material that has been certified by a regulatory body (i.e. NIST, USEPA, NRC or other agency of equal reliability). (2) STANDARD ADDITION: The practice of adding known amounts of an analyte to a sample immediately prior to analysis. It is typically used to evaluate interferences. 4 of 6

STANDARD DEVIATION (SD): where: ( X i X ) S = ( n 1) X i = the final analytical results, in the typical reporting units for the 8 or more replicate aliquots _ ( i = 1 to n). X = the average of the replicate results. 2 SOP-316 SURROGATE STANDARD (SS): An organic compound which is similar to the target analyte(s) in chemical composition and behavior in the analytical process, but which is not normally found in environmental samples (such as deuterated compounds). Surrogates are added prior to extraction to monitor extraction efficiency and percent recovery in each sample. (3) TAT: Turn Around Time. TCLP: Toxicity Characteristic Leaching Procedure, US EPA Method 1311. THMs: Trihalomethanes. TRAVELLING BLANK: A sample of analyte-free media taken from the laboratory to the sampling site and returned to the laboratory unopened. Used to document contamination attributable to shipping and field handling procedures. This type of blank is useful in documenting contamination of volatile organics samples. TRAVELLING SPIKED BLANK: A sample of uncontaminated reagent water free of any interfering substances to which a known amount of standard solution and appropriate preservative have been added by the laboratory performing the analysis. The travelling spiked blank must be prepared within 24 hours of accompanying the sample containers to the sampling location. The travelling spiked blank is brought to the field and returned, unopened to the lab for analysis. (2) USEPA: US Environmental Protection Agency. VOCs: Volatile Organic Compounds. VOC FREE WATER: Water in which an organic interferent is not observed at the method detection limit of the compounds of interest (for volatiles and semi volatiles analytics). REFERENCES: (1) Standard Methods for the Examination of Water and Wastewater, 20th edition, Introduction section 1000 (2) MISA Protocol for the Sampling and Analysis of Industrial / Municipal Waste Water, revised January 1999 (3) EPA SW-846 (4) CAEAL Policy on the Estimation of Uncertainty of Measurement in Environmental Testing, R 1.0, August 2002. (5) Chemical Technicians Ready Reference Handbook, 3 rd Edition 5 of 6

FUTURE TERMS / DEFINITIONS (to be included / considered in the next revision of this SOP): PALCAN ILAC EURACHEM / CITAC SOP-316 6 of 6