Reversed Phase Solvents

Similar documents
General Principles of HPLC Method Development

Part 2. Overview of HPLC Media

mau 200 ph min

LC and LC/MS Column Selection Flow Chart

UPLC Method Development and Validation

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Packings for HPLC. Packings for HPLC

Your Reversed Phase Method

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

penta-hilic UHPLC COLUMNS

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Shodex TM ODP2 HP series columns

Method Development Kits

Overview Applications of NUCLEODUR HPLC Phases

penta-hilic UHPLC COLUMNS

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Chemistry Instrumental Analysis Lecture 28. Chem 4631

A C18 Silica Column With Exceptional Temperature and ph Stability

Reversed Phase Chromatography: Mobile phase Considerations

LC Technical Information

8. Methods in Developing Mobile Phase Condition for C18 Column

Choosing Columns and Conditions for the Best Peak Shape

HPLC Column Classification

Gemini-NX Performance paired with Axia Technology

for Acclaim Mixed-Mode HILIC-1 Column

Inertsil ODS-EP Technical Information

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

Analysis - HPLC A.136. Primesep 5 µm columns B.136

How proteins separate on reverse-phase HPLC

Hypersil BDS Columns TG 01-05

RP C18 column with feature of a silanol group

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Comparison of different aqueous mobile phase HPLC techniques

William E. Barber, Ph.D. Applications Chemist October

Leave Your Footprint!

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Technical Guide Thermo Scientific Syncronis HPLC Columns

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

The Theory of HPLC. Ion Pair Chromatography

Too Polar for Reversed Phase What Do You Do?

Silanol. Groups Liquid Chromatography

C18 Column. Care & Use Sheet

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Fluophase and Fluofix Columns

Optimisil HPLC & UPLC Column catalogue

Small Molecule Selectivity Sampler

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

M > ACN > > THF

Hillel K. Brandes and David S. Bell Supelco, Liquid Separations, Bellefonte PA T GIH

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

InertSustainSwift C8

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Alltech Alltima HP Introduction

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Application Note. Food. Abstract. Author

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

Acclaim Mixed-Mode WCX-1

Cation Exchange HPLC Columns

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

ANALYSIS OF BASIC COMPOUNDS

for Acclaim Mixed-Mode WCX-1

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Acclaim Mixed-Mode WAX-1 Columns

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

State-of-the-art C18 HPLC Columns

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

LC-MS compatible Separation of the Fungicide Spiroxamine

Open Column Chromatography, GC, TLC, and HPLC

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

HPLC Method Development with Eclipse Plus: Standard Practices and New Columns. Agilent Technologies

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

CLIPEUS - A Small Shield for a Big Job

High Performance Liquid Chromatography

ACE Ultra Inert Base Deactivated HPLC Columns

The Theory of HPLC. Normal Phase (Absorption) Chromatography

Integrated approach to HPLC method development: Using all the tools in the chromatographer s toolbox

Scaling Up to Preparative Chromatography

Synthesis and Use of a New Covalently Bonded C18 Modified Carbon Clad Microporous Zirconia for Fast High Temperature Separations

Leveraging Bonded Phase Selectivity. to Achieve Better Reversed Phase HPLC Separations

InertSustainSwift C8

Hints for Strong Ion Exchange Resins

"Theory and Practice of High Speed Chromatography for Bioanalysis" Stuart Coleman March 20, 2007

Transcription:

Part 1. General Chromatographic Theory Part 2. verview of HPLC Media Part 3. The Role of the Mobile Phase in Selectivity Part 4. Column Care and Use Reversed Phase Solvents 2

Solvents for RP Chromatography Stationary Phase: Bonded phase (C18 vs Phenyl) Particle (Core-shell vs Monolith) Mobile Phase: Choice of solvent (ACN vs MeH) Mobile phase ph Temperature Gradients Mobile phase selection is much more challenging that stationary phase selection because the options are limitless. However, in practical method development, we can dramatically narrow down the options to focus on those conditions which will give us the highest likelihood of success. Typical RP Solvents: Solvents for RP Chromatography Weak Solvent: Water/Buffer Strong Solvent: Acetonitrile (64) Methanol (34) Composite mixtures (1) THF (1) Frequency of use

Solvents for RP Chromatography The solvent strength of a solvent will depend upon its hydrophobicity. The solvent strengths will determine the amount of solvent needed to elute a given compound. Reversed Phase Solvent Strengths: Water 0 Methanol 2.6 Solvent Strength Acetonitrile 3.1 THF 4.4 ther considerations when selecting solvents: Methanol high viscosity may limit use of smaller particle size or longer columns at elevated flow rates Acetonitrile relatively high cost THF UV absorbance at low wavelengths; high viscosity Solvent Strength Column: Gemini 5 µm C6-Phenyl, 150 x 4.6mm Mobile phase: 20mM KH 2 P 4, ph 2.5; % organic as noted Flow rate: 1.0 ml/min Detection: UV @ 220nm 35% Methanol 1. Saccharin 2. p-hydroxybenzoic Acid 3. Sorbic Acid 4. Dehydroacetic Acid 5. Methylparaben 20% Acetonitrile Analytes elute earlier when using acetonitrile (even at lower % ACN) Change in elution order when switching to ACN

Solvent Selectivity The elution strength of a given solvent is determined by its hydrophobicity (e.g. heptane would be stronger than hexane because it is more hydrophobic). The selectivity of a solvent, however, is determined by its polar characteristics (e.g. heptane and hexane would have the same solvent selectivity). Methanol is a strong proton donor and a strong proton acceptor in hydrogen bonding. C H 3 H Acetonitrile has a dipole moment but is only a very weak proton acceptor in hydrogen bonding. N CH 3 Tetrahyrofuran is able to accept a proton in hydrogen bonding but cannot donate a proton. Solvent Selectivity ptimum Separation of 4 Steroids in Different Solvents:

Solvent Screening for Isocratic Methods 1. Start at high %acetonitrile and work backwards until k is 2-10 (if possible) 80% ACN 40% ACN 25% ACN 21% ACN k = 0 k ~ 0.8 k ~ 6 k ~ 11 Solvent Screening for Isocratic Methods 2. Repeat with alternative solvent:

Solvents and Phenyl Selectivity For any reversed-phase method, the choice of acetonitrile or methanol will have a significant effect on the final selectivity of the method. However, when using phenyl phases (e.g. Luna Phenyl-Hexyl; Synergi Polar-RP), you will find that methanol is a much more effective solvent for bringing out the unique pi-pi selectivity of the phenyl phase. This is most likely due to the fact that the pi electrons of the nitrile bond in acetonitrile is able to disrupt interactions between the pi electrons of analyte molecules and the stationary phase phenyl ring pi electrons, while methanol is unable to do this as effectively. Methanol is a strong proton donor and a strong proton acceptor in hydrogen bonding. C H 3 H The nitrile bond in Acetonitrile may disrupt pi-pi interactions between phenyl rings in the stationary phase and analyte molecule. N CH 3 Solvents and Phenyl Selectivity Columns: 5 m C18(2) 150x4.6 mm 5 m Phenyl-Hexyl 150x4.6 mm Mobile phase: A: 20 mm Potassium phosphate ph 2.5 B: 27% Acetonitrile or 50% Methanol Flow rate: 1.0 ml/min Components: Extract from Goldenseal: 1. Hydrastine 2. Berberine N N Hydrastine Berberine

Solvents and Phenyl Selectivity 27:73 Acetonitrile : 20 mm Potassium Phosphate ph 2.5 m A U 120 C18(2) 100 80 60 40 20 0 1 2 3 4 5 m in m A U 120 Phenyl-Hexyl 100 80 60 40 20 0 1 2 3 4 5 m in Solvents and Phenyl Selectivity 50:50 Methanol : 20 mm Potassium Phosphate ph 2.5 m A U 100 1 2 C18(2) 80 60 40 20 0 5 10 15 20 25 m in m A U 60 1 50 2 Phenyl-Hexyl 40 30 20 10 0 5 10 15 20 25 m in

Buffers and the Role of Mobile Phase ph 15 Buffer Selection for RP HPLC Choosing the correct buffer for HPLC method development can seem very intimidating due to the vast number of buffers available. But it s really not, because the majority of methods use just a few buffers!! Practical considerations when evaluating mobile phase ph: 1. Stability of target analyte(s) 2. Hydrolysis of stationary phase at low ph Acids stronger than TFA will cause loss of stationary phase Decrease in retention, exposure of silanols groups Stability limit will vary depending vendor/brand of media 3. Dissolution of silica at high ph Typical silica-based phases stable up to ph ~8 Protective bonding (e.g. Luna) increases stability to ph ~10 rganosilica hybrid (e.g. Gemini) increases stability to ph ~12

Buffer Selection for RP HPLC = Typical for LC/UV = Typical for LC/MS Buffer Selection for RP HPLC Buffers for Low ph pka Range TFA <2 <2.5 Phosphoric acid 2.1 1.1-3.1 Formic Acid* 3.8 2.8-4.8 Buffers for High ph pka Range Bicarbonate (pk2) 10.3 9.3-11.3 2.5 4.5 7.0 8.5 10 Buffers for Neutral ph pka Range Phosphate (pk2) 7.2 6.2-8.2

Effect of ph on Base Silica Any silica-based RP material will have some residual silanols left after bonding and end-capping. These Si-H groups can be deprotonated at values above ph ~3.5. The deprotonated silanols are more likely to engage in ion-exchange with basic analytes, leading to peak tailing. ph <3.5 ph >3.5 Si Si Si Si Si Si H H H Si Si Si Si Si Si H Silanols protonated Less ion-exchange Less peak tailing Silanols deprotonated Increased ion-exchange Increased peak tailing Effect of ph on Analyte Ionization The primary mechanism of retention in RP chromatography is hydrophobic interaction. Ionizing compounds will cause them to behave as more polar species, and reduce their hydrophobic interaction with the stationary phase, leading to decreased retention. More hydrophobic More strongly retained Less hydrophobic Less strongly retained More hydrophobic More strongly retained Less hydrophobic Less strongly retained The ionization state of a molecule will be determined by the ph of the mobile phase. Therefore, mobile phase ph will dictate retention behavior of analytes with ionizable functional groups.

Effect of ph on Analyte Ionization Acidic Compounds: Basic Compounds: Capacity Factor (k ) Capacity Factor (k ) Effect of ph on Analyte Ionization Alkaline H + Acidic Alkyl Stationary Phase Aqueous Mobile Phase

Effect of ph on Analyte Ionization Alkaline H + Acidic H + Alkyl Stationary Phase Aqueous Mobile Phase Effect of ph on Analyte Retention Amitriptyline (pka 9.4) = (B)ase Toluene = (N)eutral Naproxen (pka 4.5) = (A)cid B A A B A B N N N

ptimizing Mobile Phase Selectivity High Efficiency C18 Identify appropriate buffer Yes Is there a specific ph limitation? No Screen solvents: ACN, MeH Low ph Screening using ACN, MeH Adjust ph to modulate retention and selectivity Adjust ph to modulate retention and selectivity Alternative Stationary Phase Alternative Stationary Phase Method Development Exercise 3: ptimizing Mobile Phase and Stationary Phase 26

ptimizing Mobile and Stationary Phase Analysis of nicotine and metabolites: Nicotine (pka ~8) Anabasine Cotinine H Hydroxycotinine Nornicotine 27 ptimizing Mobile and Stationary Phase Core-Shell C18 Is there a specific ph limitation? No Low ph Screening using ACN

ptimizing Mobile and Stationary Phase Mobile phase: A = 0.1% Formic acid in water B = 0.1% Formic acid in acetonitrile Gradient 5% to 95% in 10 min Flow rate: 1.5 ml/min Detection: 254 nm Components: Nicotine (0.1%), 1 µl injection + Nicotine (pka ~8.5) CH 3 29 Poor retention at low ph due to ionization ptimizing Mobile and Stationary Phase Core-Shell C18 Is there a specific ph limitation? No Low ph Screening using ACN Adjust ph to modulate retention and selectivity

ptimizing Mobile and Stationary Phase Mobile phase: A = 10mM ammonium bicarbonate ph 10.5 B = acetonitrile Gradient 5% to 95% in 10 min Flow rate: 1.5 ml/min Detection: 254 nm Components: Nicotine (0.1%), 1 µl injection 31 Improved retention at high ph ptimizing Mobile and Stationary Phase Core-Shell C18 Is there a specific ph limitation? No Low ph Screening using ACN, MeH Adjust ph to modulate retention and selectivity rganosilica Hybrid C18 Core-Shell is not stable at ph 10.5

High ph using rganosilica Hybrid Column: Gemini-NX C18, 3 µm 50 x 2.0 mm Mobile Phase: A: 20 mm Ammonium Bicarbonate B: 100% Acetonitrile Gradient: Time (min) B (%) 0.00 10 3.00 75 3.10 10 5.00 10 Flow Rate: 0.5 ml/min Injection Volume: 10 µl Temperature: 25 C 33 Gradient Analysis 34

Gradient Analysis The purpose of gradient elution is to separate in the same chromatography run, compounds which differ widely in hydrophobicity, and which would not elute in a reasonable amount of time using isocratic elution. Gradient elution: Sharpens peaks for better quantitation Improves the detection of small, later eluting peaks Is useful to clean and regenerate the column after each run Is useful for scouting analytical conditions 35 Columns: Mobile phase: Flow rate: Components: 3 µm C18(2) 50x4.6 mm 70:30 0.1% TFA in Water : 0.1% TFA in Acetonitrile 2.0 ml/min 1. Thiourea (t 0 marker) 2. Caffeine 3. Phenol 4. Acetophenone 5. Dimethylphthalate 6. Butyrophenone 7. Valerophenone 3 µm C18(2) 50x4.6mm 70:30 0.1% TFA in Water : 0.1% TFA in Acetonitrile 2.0 ml/min 1. Thiourea (t 0 marker) 2. Caffeine 3. Phenol 4. Acetophenone 5. Dimethylphthalate 6. Butyrophenone 7. Valerophenone 400 300 200 100 Gradient Analysis 4 1+2 18 min 3 5 6 7 0 0 2 4 6 8 10 12 14 16 18 min 3 µm C18(2) 50x4.6mm A = 0.1% TFA in Water B = 0.1% TFA in Acetonitrile 5 to 100% B in 5 min 2.0 ml/min 350 300 250 200 1 4 6 4 min 7 150 100 2 3 5 50 0 0 05 1 15 2 25 3 35 4 45 min 36

Gradient Analysis The gradient slope is analogous to solvent strength in isocratic elution. Isocratic Solvent Strength: Increasing the solvent strength reduces analysis time but also reduces resolution. Decreasing the solvent strength increases resolution at the cost of increased analysis time. Solvent strength sometimes affects selectivity Gradient Slope: Increasing the gradient slope reduces analysis time but also reduces resolution. Decreasing the gradient slope increases the resolution at the cost of increased analysis time. Gradient slope sometimes affects selectivity The goal of gradient elution is to optimize resolution while minimizing analysis time. Example: Five herbicides Column used: C18 150 x 4.6mm Gradient Analysis

Gradient Analysis Five herbicides in isocratic elution mode: Effect of Gradient Rate on Retention Gradient slope: 1% / minute 20-80% ACN over 60 minutes 3 1 2 4 5

Effect of Gradient Rate on Retention Gradient slope: 2% / minute 20-80% ACN over 30 minutes Effect of Gradient Rate on Retention Gradient slope: 3% / minute 20-80% ACN over 20 minutes

Effect of Gradient Rate on Retention Gradient slope: 4% / minute 20-80% ACN over 15 minutes Lost Resolution! *Increasing the gradient slope will decrease overall retention and also decrease resolution Gradient slope: 3% / minute; Initial Strong Solvent = 30% 30-90% ACN over 20 minutes Effect of Starting %rganic Lost Resolution! *Increasing the amount of starting strong solvent will decrease overall retention and resolution

Gradient Method Summary 1. Begin with scouting gradient to see analyte elution times: 5-95% organic over X min (1 min per cm of column length) 150x4.6 mm = 5-95% B over 15 min 2. Make adjustments to starting % organic to accommodate early-eluting components isocratic hold at 3% organic for x min 3. Adjust gradient slope to optimize resolution or critical pairs Shallower to improver R s (5-95% B over 20 min) Steeper if you have excess R s (5-95% B over 12 min) 4. ptimize ending % organic for clean-up Stop gradient at 65% B 5. Adjust starting % organic to reduce run time (if not limited by polar components) 5-65% B over 18 min 10-70% B over 18 min 15-75% B over 18 min Effect of Temperature 46

Temperature in HPLC Methods The use of temperature in HPLC method development presents a challenge because it can have unpredictable effects on selectivity. The use of elevated temperatures will: 1. Reduce mobile phase viscosity and back-pressure. This can allow you to operate at higher flow rates, or to use longer columns/smaller particle sizes. 2. Reduce elution time. 3. Improve method reproducibility (as opposed to operating at room temperature). However, it is impossible to determine if the use of elevated temperatures will help or hinder a specific separation. For complex separations, improvements in one portion of the chromatogram are almost always accompanied by decreases in another part of the same chromatogram. Temperature in HPLC Methods

Temperature in HPLC Methods In our method development work: 1. Initial method development is performed at 30 ºC. Column screening Mobile phase selection and optimization 2. Higher temperatures are investigated only when: We need to reduce back-pressure (usually with increasing flow rate or using a longer column length) Unable to achieve required resolution at 30 ºC Method Development Exercise 3: Gradient ptimization and Phase Screening 50

Gradient Method ptimization Barbiturates are CNS depressants, and have been used to induce anaesthesia, and treat anxiety and insomnia, but are also subject to abuse. The challenge with LC/MS analysis of these compounds is that amobarbital and pentobarbital are isomers with the same mass and must be separated chromatographically. Amobarbital pka = 7.8 Pentobarbital ptimize Mobile Phase and Stationary Phase Basic Sample Info: No ph restriction Clean Sample 10 cm Goal of separation: Resolution of Amo/Pentobarbital Solvent? ACN for low viscosity Buffer? Neutral (ammonium acetate) for negative ionization

1. Rapid, steep gradient slope to determine general behavior of analytes: 10-90% B over 5min; 16% / min Scouting Gradient Good retention Good peak shape No separation Reduce gradient slope Gradient ptimization 10-90% B over 5 min; 16% / min 10-90% B over 10 min; 8% / min 10-90% B over 40 min; 2% / min

Final Barbiturate Method Intensity, cps Final Method: XIC of -MRM (12 pairs): 223.1/42.1 Da ID: Butalbital-2 from Sample 9 (1.0-2-1) of 021... 2.7e6 2.6e6 2.4e6 2.2e6 2.0e6 1.8e6 1.6e6 1.4e6 1.2e6 1.0e6 1. Phenobarbital 2. Butalbital 3. Pentobarbital 4. Amobarbital 5. Secobarbital Max. 2.7e6 cps. Running conditions 2.6 µm Core-Shell C18 100x2.1 mm A = 5mM ammonium acetate B = Acetonitrile 500 µl/min 10-45% B over 10 min 8.0e5 6.0e5 4.0e5 2.0e5 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 49 96 144 191 239 287 334 382 429 477 Time, min Reasonable resolution in ~10 minute run time Need to balance adequate resolution with sample throughput End of Part III 56