Really, A Revised MDL Procedure

Similar documents
EPAs New MDL Procedure What it Means, Why it Works, and How to Comply

EPA's Revision to the 40 CFR Part 136 Method Detection Limit (MDL) Procedure

VOTING DRAFT STANDARD

TNI Standard; EL-V1M4 Sections and (Detection and Quantitation) page1 of 8. TNI Standard VOLUME 1 MODULE 4

The New MDL Procedure How To s. Presented by: Marcy Bolek - Alloway

TNI V1M Standard Update Guidance on Detection and Quantitation

Proposed Procedures for Determining the Method Detection Limit and Minimum Level

Verification of LOD and LOQ according to the NELAC and TNI Standards

IMPROVE DETECTION AND QUANTITATION. Richard Burrows

DRAFT. The NELAC Institute Presents VERIFICATION OPTIONS FOR

Method Update Rule of 2015: New Method Detection Limit MDL Determination. David Caldwell OK DEQ Laboratory Accreditation Program

How s that *new* LOD Coming? Rick Mealy WWOA Board of Directors DNR LabCert

Anand pointed out that the adjournment time in Section 6 should be EDT.

SUGGESTED PROCEDURES FOR

Utilizing Data Trend Evaluations in Method Audits and Regulations Development

SUMMARY TNI CHEMISTRY EXPERT COMMITTEE MEETING

QA/QC in the Wastewater Laboratory. Steve Roberts Ohio EPA Division of Environmental Services 05/11/2016

Review and Reporting of Chemical of Concern (COC) Concentration Data Under the TRRP Rule (30 TAC 350)

Application of Detection and Quantification Concepts to Chlorine Residual Measurements

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

DATA QUALITY: DETECTION LIMITS ARE AN IMPORTANT DRIVER

And how to do them. Denise L Seman City of Youngstown

Laboratory Analytical Data

Measurement Uncertainty: A practical guide to understanding what your results really mean.

VALIDATION OF ANALYTICAL METHODS. Presented by Dr. A. Suneetha Dept. of Pharm. Analysis Hindu College of Pharmacy

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Environmental Measurement Glossary of Terms January 11, 2010

ALLOWAY METHOD OUTLINE

CHAPTER VI ANALYTICAL METHODS & QUALITY CONTROL

Method Validation and Accreditation

Laboratory 101: A Guide to Understanding your Testing Laboratory

Is the laboratory s pledge or declaration of the quality of the results produced. to produce data compliant with the Safe Drinking Water Act (SDWA)

LOWER DUWAMISH WATERWAY CLAM COLLECTION FINAL AND CHEMICAL ANALYSES QUALITY ASSURANCE PROJECT PLAN ADDENDUM. Lower Duwamish Waterway Group

SWGDRUG GLOSSARY. Independent science-based organization that has the authority to grant

Qualification Code Reference Table Cont.

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Results of the EPA Method 1631 Validation Study

Part IVB Quality Assurance/Validation of Analytical Methods

EPA Office of Water Method Update Rule Final August 28, 2017 William Lipps October 2017

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Understanding the Uncertainty Associated with Analytical Results: Sources, Control and Interpretation of Results. Marc Paquet, Chemist M.Sc.

APPENDIX II QUALITY CONTROL SUMMARY TABLES

QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY.

Low Level Phosphorus: A Method Comparison Study

Enclosed is a copy of your laboratory report for test samples received by our laboratory on Thursday, February 25, 2010.

Certificate of Analysis FINAL REPORT

Best Practices for Obtaining Samples of Known Quality

American Environmental Testing Laboratory Inc.

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

Maine DEP DRO. MY05TP220A(0-0.5) MY05TP222A(0-0.5) FD MY05TP223A(0-0.5) FD MY05TP220A (EB) EB-Equipment Rinsate Blank FD- Field Duplicate Samples

ENVIRONMENTAL LABORATORY SECTOR VOLUME 1 MANAGEMENT AND TECHNICAL REQUIREMENTS FOR LABORATORIES PERFORMING ENVIRONMENTAL ANALYSIS

ANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503

ANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL METHODS & QUALITY CONTROL

ANALYTICAL REPORT. Attn: Richard Boelter

SYNOPSIS OF CHANGES TO BC LABORATORY MANUAL, MARCH 2017

ENVIRONMENTAL LABORATORY SECTOR MODIFIED WORKING DRAFT STANDARD (MWDS) VOLUME 1

Liquid Scintillation Counter

METHOD 8000A GAS CHROMATOGRAPHY

CSO/SWO Data Validation Reports June 20, 2014

Method Validation. Role of Validation. Two levels. Flow of method validation. Method selection

ALPHA ANALYTICAL LABORATORIES. Eight Walkup Drive Westborough, Massachusetts (508)

LCMRL: Improved Estimation of Quantitation Limits

Regulatory and Alternative Analytical Procedures are defined as follows 2 :

Table of Contents I. PURPOSE AND SCOPE:... 3 II. AUTHORITY:... 3 III. REFERENCE:... 3 IV. RESPONSIBILITY:... 3 V. POLICY:... 3 VI. PROCEDURE:...

LAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.)

ANALYTICAL REPORT. Job Number: Job Description: TO4-2012, RACER, GM Wilmington

alscience nvironmental aboratories, Inc.

Performance characteristics of analytical tests

Recovery/bias evaluation

Laboratory ID. Laboratory Name. Analyst(s) Auditor. Date(s) of Audit. Type of Audit Initial Biennial Special ELCP TNI/NELAP.

Sample RM Analytical Report ( B) HPLC/UV Analysis Acetaldehyde, Acrolein, Crotonaldehyde, Formaldehyde

DHL Analytical received 2 sample(s) on 6/18/2009 for the analyses presented in the following report.

Calibration (The Good Curve) Greg Hudson EnviroCompliance Labs, Inc.

TCEQ Regulatory Guidance Remediation Division RG-366/TRRP-13 December 2002

APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY

Examples of Method Validation Studies Conducted in Different Economies

How to develop an ATP.... and verify it has been met. Melissa Hanna-Brown Analytical R & D; Pfizer Global R+D, Sandwich UK.

Hydra-C Application Note: 1076

ANALYTICAL REPORT. Attn: Thomas W Hensel

QAM-Q-101 Laboratory Quality Control

Cyanide Methods for Lachat Automated Ion Analyzers. Flow Injection Analysis

Collaboration on Calibration

Samples compliant with the WATER

COLA Mass Spec Criteria

Method Update Rule (MUR) impact on Detection Limits

Method 8270C PAH. FD- Field Duplicate Samples

APPENDIX G ESTIMATION OF UNCERTAINTY OF MEASUREMENT

DETECTION LIMITS: THE GOOD, THE BAD, AND THE UGLY. Charles Lytle City of Portland Bureau of Environmental Services

EDD FIELD DESCRIPTIONS

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL RESULTS. Project: Mayflower, AR Pipeline Incident

EAA STAFF ATTACHMENT 13 DECEMBER Appendix D Analytical Data Validation Discussion

Test Method Development and Validation as Pertaining to Microtrac Particle Size Measuring Instruments

One Stop DIY Shop. PO Box 104 New Germany, MN Carbonyl Assay. Samples Received 09/09/2014. Analysis Report ( )

ACZ Laboratories, Inc Downhill Drive Steamboat Springs, CO (800)

Validation of analytical methods. Adrian Covaci Toxicological Center, University of Antwerp

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Transcription:

NEMC 2016 Really, A Revised MDL Procedure Richard Burrows, Ph.D. TestAmerica Inc. 1

A Revision to the Method Detection Limit EPA published a revision to the 40 CFR Part 136 MDL procedure in the Federal Register on Thursday February 19 th 2015 EPA expects that the rule will be finalized in late 2016

TNI Chemistry Standard Revisions to the Detection, Quantitation and Calibration language in TNI Volume 1 Module 4 (Quality Systems for Chemical Testing) are complete and will be incorporated into the TNI 2015/2016 Standard. The 2015/2016 TNI Standards should be adopted by the States in 2017/2018

MDL and TNI revisions!!?? What if they have different requirements? What if they are implemented at different times? What if different states adopt the new requirements at different times? Will I have to have different detection limits for different states? 4

5

Good News The revised MDL and TNI Chemistry standards are fully compatible If you are compliant with the revised EPA MDL then you are also compliant with the current MDL One exception, discussed later If you are compliant with the revised TNI Chemistry standard then you are compliant with the current TNI Chemistry standard 6

How to do a LOQ / MDL study 7

Select LOQ Choose your LOQ Must be at or above low calibration standard If blanks are non zero, then calculate mean + 3X standard deviation. This will approximate the MDL and spiking level should be at least 2-3 times higher Spike ideally in the range 0.5-1 x LOQ 8

Run the spiked and blank samples Spikes Minimum 7 spikes Minimum 3 separate batches and three separate days ~ Prep and analytical Minimum 2 on each instrument Blanks Use existing If new method, minimum 7, at least 3 batches, at least 3 days, at least 2 per instrument 9

Initial evaluation Do the spike results meet qualitative identification criteria in the method? Calculate precision and accuracy, and the MDL Adjust the LOQ if necessary 10

Slide on calculation of MDL b and MDLs MDL spike = ts spike MDL blank = X + ts blank MDL = the greater of MDL spike and MDL blank 11

Slide on evaluation of LOQ recovery Lab sets recovery criteria for the LOQ Based on what? Options Method criteria QAPP criteria LCS historical with some extra leeway (Method 8000) 12

Good precision, moderate recovery Spike 1 2 3 4 5 6 7 10 7 7.3 6.9 8.1 7.7 7.3 7.9 MEAN STD. DEV MDL S 7.5 0.5 1.4 Blanks ND ND ND ND ND ND ND MEAN STD. DEV MDL B 0.0 0.0 0.0 MDL 3X MDL LOQ 1.4 4.3 10.0 Success! Spikes work for calculation of the MDL And Verification of the LOQ

Poor/Moderate precision and recovery Spike 1 2 3 4 5 6 7 10 6 7.3 7.6 5.7 7.2 7.9 5.3 MEAN STD. DEV MDL S 6.7 1.0 3.2 Blanks ND ND ND ND ND ND ND MEAN STD. DEV MDL B 0.0 0.0 0.0 MDL 3X MDL LOQ 3.2 9.7 10.0 Success! Spikes work for calculation of the MDL And Verification of the LOQ

Poor precision, poor recovery Spike 1 2 3 4 5 6 7 10 5 7.1 3.2 6.5 7.4 3 3.3 MEAN STD. DEV MDL S 5.1 1.9 6.1 Blanks ND ND ND ND ND ND ND MEAN STD. DEV MDL B 0.0 0.0 0.0 MDL 3X MDL LOQ 6.1 18.2 18.0 Marginal! Spikes work for calculation of the MDL And Verification of the LOQ But LOQ must be elevated above the spiking level

Poor precision, poor recovery Spike at ½ desired LOQ Spike 1 2 3 4 5 6 7 5 2.5 3.55 1.6 3.25 3.7 1.5 1.65 MEAN STD. DEV MDL S 2.54 0.97 3.04 Blanks ND ND ND ND ND ND ND MEAN STD. DEV MDL B 0.0 0.0 0.0 MDL 3X MDL LOQ 3.04 9.12 10 Success! Spikes work for calculation of the MDL And Verification of the LOQ

Good precision, elevated blanks Spike 1 2 3 4 5 6 7 10 13.5 12.8 14.2 14.6 13.4 13.7 13.9 MEAN STD. DEV MDL S 13.7 0.6 1.8 Blanks 3.1 4.2 3.9 4.4 3.8 3.2 4 MEAN STD. DEV MDL B 3.8 0.5 5.3 MDL 3X MDL LOQ 5.3 16.0 16.0 Marginal! Spikes work for calculation of the MDL And Verification of the LOQ But LOQ must be elevated above the spiking level

Ongoing MDL LOQ 18

Quarterly spikes Run at least one spike on each instrument once per quarter, at the same concentration as the initial spikes MDL Must be detected, above zero, using qualitative identification criteria in the method LOQ Must meet the recovery criteria in the lab SOP 19

Annual assessment MDL Recalculate the MDLs and MDLb MDLb uses the routine method blanks Compare with the existing MDL If within a factor of 2 Lab option to update or not If outside factor of 2 Must update LOQ Update the precision and bias statement 20

What do we expect if the true value is at the LOQ? Known precision? Known accuracy? Ability to detect and report? Freedom from false negatives?

What do we expect from a true value at the MDL? Known accuracy? Ability to detect and report? Freedom from false negatives? We do expect freedom from false positives (99%) when the analyte is not present

What does this mean to labs? Clear requirements Sensible MDLs Level playing field Low transition costs since existing data can be used Note labs should start complying with 3 batch rule right now Some additional organizational requirements 23

What does this mean to data users? MDLs that make sense Much lower rate of false positives, especially for ICP, ICPMS and some general chemistry tests Easier to compare labs In general, more reliable data = better decision making 24

How much will MDLs change? Analytes with minimal or no detects in blanks, eg most GC/MS analytes at normal levels: Not Much Analytes with frequent detects in blanks, eg, metals, very low level PAH, some general chemistry tests: Depends If the lab is currently adjusting MDLs to avoid excessive false positives, not much If the lab has been pushing MDLs below levels justified by the blanks, potentially quite a bit 25