Microfluidic biosensor for single cell high speed flow impedance spectroscopy

Similar documents
Single cell impedance spectroscopy label free analysis of cells

Model of an Interdigitated Microsensor to Detect and Quantify Cells Flowing in a Test Chamber.

Micro/nano and precision manufacturing technologies and applications

Microdevices for Continuous Sized Based Sorting by AC Dielectrophoresis

Supplementary Figure 1 a) Scheme of microfluidic device fabrication by photo and soft lithography,

SUPPLEMENTARY FIGURES

Simulation of CMOS compatible sensor structures for dielectrophoretic biomolecule immobilization

Electronic Supplementary Information. Continuous Flow Microfluidic-MS System for Efficient OBOC Screening

Lecture 18: Microfluidic MEMS, Applications

CURRENT STATUS OF NANOIMPRINT LITHOGRAPHY DEVELOPMENT IN CNMM

High-resolution on-chip supercapacitors with ultra-high scan rate ability

Development and Characterization of High Frequency Bulk Mode Resonators

Fast Biofluid Transport of High Conductive Liquids Using AC Electrothermal Phenomenon, A Study on Substrate Characteristics

Design and Analysis of Cell Counter using Spice Simulation

Structuring and bonding of glass-wafers. Dr. Anke Sanz-Velasco

UNIT 3. By: Ajay Kumar Gautam Asst. Prof. Dev Bhoomi Institute of Technology & Engineering, Dehradun

Supplementary Materials for

Chapter 3 Engineering Science for Microsystems Design and Fabrication

Supporting information for. Microfluidic Impedance Cytometer with Inertial Focusing and. Liquid Electrodes for High-Throughput Cell Counting and

GHZ ELECTRICAL PROPERTIES OF CARBON NANOTUBES ON SILICON DIOXIDE MICRO BRIDGES

MSN551 LITHOGRAPHY II

Cruz, J., Hooshmand Zadeh, S., Wu, Z., Hjort, K. (2016) Inertial focusing of microparticles and its limitations. In: (pp. 1-6).

Experimental mixing characterization of Newtonian fluids mixing in asymmetric T-micromixers

Supplementary information for

SCME KIT OVERVIEW. Rainbow Wafer Kit

percolating nanotube networks

Programmable Magnetic Actuation of Biomolecule Carriers using NiFe Stepping Stones

Micro-sensors based on thermal transduction for steady and unsteady flow measurements

Supplementary Information Our InGaN/GaN multiple quantum wells (MQWs) based one-dimensional (1D) grating structures

Nanotechnology Fabrication Methods.

Laboratory-on-chip based sensors Part 2: Capacitive measurements

ARFTG 84th WORKSHOP The New Frontiers for Microwave Measurements

INTERDIGITATED CAPACITIVE SENSOR TO VERIFY THE QUALITY OF ETHANOL AUTOMOTIVE FUEL

On the Design and Optimization of Micro-Fluidic Dielectrophoretic Devices: A Dynamic Simulation Study

Particle concentration influences inertial focusing in Multiorifice Flow Fractionation microfluidic devices

Technology Brief 9: Capacitive Sensors

UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences. Fall Exam 1

Self-study problems and questions Processing and Device Technology, FFF110/FYSD13

Northwestern University Mechanical Engineering Department ME Introduction to MEMS Professor Horacio Espinosa

Geometry Induced Microparticle Separation in Passive Contraction Expansion Straight Channels

Pingshan Wang. Jim Rui

Supplementary Information

3/24/11. Introduction! Electrogenic cell

Institute for Electron Microscopy and Nanoanalysis Graz Centre for Electron Microscopy

Time-of-Flight Flow Microsensor using Free-Standing Microfilaments

Ultrasonic particle and cell separation and size sorting

Introduction. Photoresist : Type: Structure:

MEMS Tuning-Fork Gyroscope Mid-Term Report Amanda Bristow Travis Barton Stephen Nary

Alternative deposition solution for cost reduction of TSV integration

Figure 1: Graphene release, transfer and stacking processes. The graphene stacking began with CVD

Wafer bonding. Supplementary Figure 1. Conventional nanofluidic sealing process. (a) Selective sealing. (b) Wafer bonding. (c) Sacrificial etching.

Transparent and ultra-bendable all-solid-state supercapacitors without percolation problems

ORION NanoFab: An Overview of Applications. White Paper

NONCONTACT PARALLEL MANIPULATION WITH MESO- AND MICROSCALE PARTICLES USING DIELECTROPHORESIS

MODELING, DESIGN AND EXPERIMENTAL CARACHTERIZATION OF MICRO-ELECTRO ELECTRO-MECHANICAL- SYSTEMS FOR GAS- CHROMATOGRAPHIC APPLICATIONS

Lecture 0: Introduction

Sensors & Transducers 2015 by IFSA Publishing, S. L.

Too many answers to list.

Design of an air-flow microchamber for microparticles detection

Dielectric Analysis of Solid Insulations

The Coulter Principle for Outlier Detection in Highly Concentrated Solutions

ESS 5855 Surface Engineering for. MicroElectroMechanicalechanical Systems. Fall 2010

Supporting Information. Railing Cells along 3D Microelectrode Tracks for a. Continuous-Flow Dielectrophoretic Sorting

Stretchable Graphene Transistors with Printed Dielectrics and Gate Electrodes

Supporting Online Material for

Contents. 2. Fluids. 1. Introduction

Sheathless Hydrophoretic Particle Focusing in a Microchannel with Exponentially Increasing Obstacle Arrays

Cells in double emulsions for FACS sorting

Supplementary Figure 1 shows overall fabrication process and detailed illustrations are given

Microfabricação em materiais poliméricos usando laser de femtossegundos

Interdigitated Electrodes (IDEs)

Etching: Basic Terminology

A. Optimizing the growth conditions of large-scale graphene films

HOW CLEAN IS CLEAN? The names employed for this test are: ROSE or SEC: ROSE = Resistivity of Solvent Extract SEC = Solvent Extract Conductivity

Application of the GD-Profiler 2 to the PV domain

Supporting Information

Supplementary Methods A. Sample fabrication

AC Electrokinetic Manipulation of Microfluids and Particles using Orthogonal Electrodes

Fast Bonding of Substrates for the Formation of Microfluidic Channels at Room Temperature

Nanoscale Issues in Materials & Manufacturing

Fabrication and Characterization of High Performance Micro Impedance Inclinometer

Structure and Characterization of Polystyrene Thin Films

Nano-mechatronics. Presented by: György BudaváriSzabó (X0LY4M)

Plasmonic Hot Hole Generation by Interband Transition in Gold-Polyaniline

Particle sizing using dielectrophoresis-active hydrophoresis

Supporting Information to Thermoplasmonic Semitransparent Nanohole Electrodes

Microfluidics and Lab-on-a-chip systems. Pelle Ohlsson

Introduction to Photolithography

COMPUTER SIMULATION OF MICROELECTRODE BASED BIO-IMPEDANCE MEASUREMENTS WITH COMSOL

Instrumental Technique: Cuvette. Md Rabiul Islam

Large-area travelling-wave dielectrophoresis particle separator

Transducers. ME 3251 Thermal Fluid Systems

Demystifying Transmission Lines: What are They? Why are They Useful?

e - Galvanic Cell 1. Voltage Sources 1.1 Polymer Electrolyte Membrane (PEM) Fuel Cell

UV-vis Analysis of the Effect of Sodium Citrate on the Size and the Surface Plasmon Resonance of Au NPs. Eman Mousa Alhajji

Dielectric properties of biological tissues at frequencies below 1 MHz. Azadeh Peyman

Optimization of Skin Impedance Sensor Design with Finite Element Simulations

Modeling of impedance of cell-covered electrodes

A Simulation Model of Fluid Flow and Streamlines Induced by Non-Uniform Electric Field

ENMA490 Capstone: Design of Microfluidics Mixer

Transcription:

Microfluidic biosensor for single cell high speed flow impedance spectroscopy J. Claudel, M. Nadi, O. Elmazria, D. Kourtiche Institut Jean Lamour (UMR 7198), CNRS (UMR7189) Université de Lorraine Vandoeuvre les Nancy, F-54506, France Julien.claudel@univ-lorraine.fr Abstract This paper presents a micro-biosensor based on Electrical Bio-Impedance Spectroscopy (EBIS), applied to blood cells characterization and diagnosis. This sensor uses microfluidic flow, coupled to EBIS system to perform cell by cell measurements at high flow rate, up to several hundred cells per second. Two devices were realized with different materials, SU_8 resin and polydimethylsyloxane PDMS to structure the microchannel. PDMS device stand higher pressure than SU_8, permitting to improve sensor reliability and the possibility to clean it. Measurements confirm it ability to detect and characterize each cell and particle in less than 1ms during their passage in a microchannel, allowing high speed diagnosis of a large amount of cells. Calibrated particles were used to check the proper functioning of the sensor and the possibility to detect and measure few variation induce by the passage of cells. biosensor; microfluidic; impedance spectroscopy; single cell I. INTRODUCTION Increasing of MicroElectroMechanical System (MEMS) and lab on chip devices directs current researcher to find new micro-nano applications and to transpose others existing technologies at micro and nanometer scale. This is the case of impedance spectroscopy [1], which allows many prospects for bioical applications as diagnosis of tissues. This method permits to determine the physiological status of bio-samples by the measurement of electrical response of living tissues and cells. Some pathologies induce changes in physical structure and chemical composition of bio-samples, thus changing electrical impedance, and can be measure and interpret. These types of measurements are perfor quite a long time on a large scale of tissues and bio-samples at macroscopic scale [2], and many models have been developed [3]. Macroscopic measurements provide general information about a large amount of different tissues which compose the global sample. One of the best examples concerns blood, composed of many really different particles as White Blood Cells (WBC), Red Blood Cells (RBC) and platelets. WBC just represent less than 1% of particles, and their impact is neglected in whole blood. Naturally, current applications are focused on characterization of microscopic samples to improve sensitivity detection. Interdigitated electrodes are one example of electrodes evolutions for small samples measurements [4][5] and single cell analysis. The most current used approaches for single cells and particles characterization are based on coulter counter method [6]. It permits to detected particles crossing a microhole drills in a thin membrane, which separate two tanks with measurement electrodes. Even if this method is easier to realized, it presents a higher critical volume in the sensing area and inducing more unusable measures and very high sample dilution. Another technic consist in capture cells by aspiration on micro-holes [7]. It able to characterized them with high sensitivity but for a few amount of total cells present in the sample. For this, flow cytometry with direct measurement in a microchannel is more and more developed for single particles measurements. This paper is based on previous works [8], center around on a microfluidic biosensor design for cell by cell measurement in dynamic. It combines microfluidic displacement and impedance spectroscopy to detect and characterize single cells at high flow rate. Microfluidic properties, used in this device, able to direct and focused some kinds of particles, one by one in restricted measurement area composed of microchannel The second section describes the sensor structure with the different parts of sensing area, composed of microelectrodes. We expose the possibility to characterize different cell properties at high flow rate, during their passage in the sensing area. Theories for electric and dielectric properties of cells suspensions are exposed, as mathematic and electric equivalent models; essential for measurement s interpretations. Third part is focused on sensor manufacturing using microfabrication technologies. The choice of different materials is detail in order to be as compatible as possible, and interact the least with samples. Two devices, made with different materials were conceived and compare during flow tests. In the Fourth part, a description of measurement setup is exposed. It is based on lock-in amplifier to perfor high speed impedance measurements at different frequencies. Measurements realized with cells and particles prove the ability to measure each cell in less than 1ms. Finally, section 5 concludes about the validity of single cell measurement and the respect of stated assumptions. 343

II. THEORETICAL A. General structure This microfluidic sensor is composed of 2 inlet and outlet tanks for liquid sample deposition, connected to a 1000µm long, 20µm wide, and 10µm high microfluidic channel, as presented in Fig. 1. These dimensions are in the same order than a large amount of cells and bacteria as blood cells or yeast cells, commonly used as references. Their choice was already discussed in our previous works, and offer a good compromise between manufacturing difficulties and sensitivity. It contains measurement area for with two pair of microelectrodes, allowing the ability to perform simple and differential measurements and monitoring particles speed. 1 2 impedance is also due to the double layer impedance. It relates to complex electrochemical reactions appearing in a very small thin layer in the interface between electrodes and sample during electric polarization [9]. It measurement can provide interesting information about the chemical species present in an electrolyte as plasma, but not about isolated cells. In flow spectroscopy, it not represents a useful measure because just depends of ium and is totally independent of cell s properties. Unlike, this effect restrict the evaluation of intrinsic characteristics of cells in low frequencies and can be modeling by a capacitance in series with the sample impedance. α β γ a) Conductivity Permittivity Figure 2. Characteristic Electric and dielectric spectrum of a living tissue. b) 1 2 Figure 1. Design of the measurement area for parallel micro-electrodes a) and coplanar microelectrodes). B. Modeling Fluidic displacement between tanks and central channel is realized with successive narrowing to create a funnel effect and centering particles. Majority of microfluidic channels provide a laminar flow, wealthy lot of interesting properties. One of them is the attribute to produce a large speed gradient difference between the center (high speed) and the edges. This particularity is effectively used to center cells and decrease the risk of aggregates formation.modeling Typical impedance of biological samples is characterized by a high impedance in low frequencies, which decreases stage by stage while keeping a zero or negative phase, proving their electric and dielectric comportments. According to this, sample impedance measurements are often represented by their conductivity and permittivity spectra, where each change of level corresponds to a relaxation: conductivity increase each time while permittivity decrease. Typically, a tissue presents 3 relaxations α, β and γ as shows in Fig. 2. The first is due to polarization of cells membranes, the second to capacitive effect of membranes and the last to dipolar orientation of water molecules. A characteristic frequency can be define for each one, and respectively operate in the range of Hz to several Hz, several khz to MHz and higher than 1GHz. Impedance measurement in flow spectroscopy is mainly focused on β relaxation. At these frequencies, impedance measurements can be realized in just several µs, and allow prospect to characterized samples at high flow rates. The γ relaxation operates at RF frequencies and depends of the properties of water molecules. At low frequencies, the high Biological samples, and especially single cells can be modeled using Maxwell Mixture Theory (MMT), a mathematical model, or Fricke s electrical model [10], as presented in Figure 3. Each cell component is symbolized in this schematic by it equivalent conductance and capacitance, image of their electrical and dielectric properties. C and R respectively represent dielectric and electric properties of ium, R i electric properties of cytoplasm, C mem the dielectric properties of cell membrane and Z dl the double layer impedance. To equate them for a single cell suspension, Hywell Morgan [11] propose optimizations and simplifications of MMT. It was define at the beginning for a mixture with a large amount of different particles, and not for just one. Calculation of each parameters is possible using (1) to (4). σ and σ i are the conductivities of ium and cytoplasm, ε the electric permittivity of ium, C mem,s the membrane capacitance per surface units, Φ the volume ratio between cell and measurement area, and k a cell factor just depending of electrodes geometry. Zdl Cmem C R Ri Zdl Figure 3. Electric Schematic of Fricke cells suspension model. 344

R C mem 1 (1 3 / 2) k 1 1 4 2 i R i 9 rcmem, s k 4 9 k C (1 3 / 2) k III. SENSOR MANUFACTURING This section describe the fabrication of devices with coplanar electrodes of 20x20µm² and spaced by 20 µm, in a 10 µm high and 20µm wide microchannel. These dimensions and structures were choice following simulations results obtained in previous works. Decreasing the gap between coplanar electrodes reduces the uniformity of electric field in the measurement area, and concentrate it at the bottom of channel. On the other hand, increasing this gap reduce the ratio Φ, and thus, the sensibility of sensor. A. Materials In bioical applications, materials choice is very important in order to improve measurement sensitivity and avoid samples contaminations. As we shown in the previous part, electrodes polarization is the root of complex electrochemical reactions. These act as barrier for low frequencies measurement, and can modify sample properties by salting out some chemical species. It is possible to strongly reduce this using materials as biocompatible as possible. To monitor the evolution of particles in the microchannel during experimentation, materials used to make it should be transparent to visible light, to be able to use optic microscope. The last exigency concern the resistance of each material against chemical agents as acetone or ethanol. Biological samples are very hard to completely remove after passage in microfluidic device, particularly because of capillarity effects. In this cases, only hard cleaning can be efficient to set a sensor reusable. Our choice was carried on the following materials: Glass (substrate): Biocompatible, relatively inert for many materials and completely transparent to visible light. Platinum (electrodes): Noble metal, one the most biocompatible. SU_8 resin: One of the most biocompatible and used in microfluidic applications, ability to create high ratio patterns and transparent. Polydimethylsiloxane (PDMS): One of the most biocompatible and used polymer in microfluidic applications, can be mold with sub-micrometric patterns and transparent. B. Manufacturing According to the dimensions of useful components of this system, UV lithography is particularly well suited. Two different methods were used to make this device. The first consists to structure the channel in SU_8 resin and enclosed it with a PDMS cover. The second consists to directly structure the channel in a PDMS block by molding. Both methods using the same technics to realize platinum electrodes, by deposition of a 150nm layer on all glass subtract by sputtering. Patterning was perfor by structuration of S1813 photoresist and dry etching by plasma, as demonstrated on Fig. 4. For the first sensor, a 10µm SU_8 layer were deposit and structure by UV lithography to form the channel. This one were irreversibly enclosed using 3mm flat PDMS block. Inlet and outlet tanks were previously pushed through PDMS. For the second, a mold were previously made by structuration of AZ9260 resin with a negative lithography mask. Microchannel was directly mold on PDMS block and irreversibly glued to glass substrate after 0 2 plasma exposure. Figure 5 expose the sensor structure finally obtained. UV UV 1. Deposit of Platinum. 2. Spin Photoresist. 3. Expose photoresist 4. Develop photoresist 5. Ion etching. 6. Strip photoresist. 7. Spin photoresist. 8. Expose Photoresist. 9. Develop photoresist 10. PDMS cover PLATINUM SU-8 SHIPLEY 1813 SUBSTRATE PDMS Figure 4. Schematic of the main steps of lithography C. Microfluidic tests Before to perform any measurements, our design were preliminary tested in flow conditions to check correct fluidic displacement and the ability to clean it after used. For that, blue ink was injected using syringe, as display in Fig.5. In both cases, we obtained laminar flow without any leak in normal conditions (low pressure). A higher pressure around 1 bar, uses to clean or unblock channel, cause SU_8 unsticking from substrate. For the second device, directly made in PDMS, it do not suffer of any damages, and can be unlock and clean at high pressure, as demonstrate on Fig. 6. 345

Figure 5. Photograph of the microfluidic device and regulate. Moreover, it is necessary to use different frequencies signals in order to completely characterize it. Classical impedancemeters and network analyzers, based on frequencies sweeping, cannot be used there. The only method available is to send a multiplexed signal including all needed frequencies. For that purpose, the impedance spectrometer HF2IS of Zurich Instrument, based on lock-in amplifier principle, were choice to perform our measurements. It permits to measure up to 8 discrete frequencies in a large band, 1µHz to 50MHz, around the β relaxation. Optic microscope with CMOS camera is used to monitor cells displacement during measurement, to check if impedance variations really correspond to cell detections and avoid the risks of channel blocking. A global schematic is show on Fig. 7. CMOS CAMERA PC: Control and signal acquisition PC: Cell and channel monitoring Optic microscope Syringue Biosensor Figure 6. Unblocking a microfluidic channel blocked by a large quantity of cells: step a to b. Tests were perfor using a very high yeast cells concentration in water, to improve the probability to block microchannel. We obtain it in the first step with an aggregate of thousands cells (Fig.6.a). After 1 minute of acetone injection at pressure around 1 bar, the majority of cells were dissociated and evacuated through channel (Fig.6.b). One other minute after, the inlet were unblocking, allowing again fluidic displacement (Fig.6.c). Even after acetone cleaning, some cells stay blocked due to high contact interactions in micrometric scale, but can be completely removed using both fluidic pressure and ultrasounds cleaner. IV. A. Measurement setup EXPERIMENTATION AND RESULTS Flow impedance measurement require dedicated measure chain, able to perform high speed measurements. Cells and particles should be detected and measured during their passage, without immobilization, in sensing area. This one is very short, just few µm, and cell flow is difficult to control 1 2 Pre-Amplifier USB Measurement signals Input 1 Input 2 Figure 7. Measurement setup used for monitor and characterized Lock-in Amplifier B. Results First experiments were realized with simple bacteria, yeast cells, diluted in physiological salt solution. Measurement were perfor with a single frequency at 500 khz, in the band between α and β relaxation. At this frequency, interface impedance can be neglected and the cell considerate as an insulating material. Measured impedance is just a function of ium resistance, and cell dimension. Impedance variation during the passage of a particle in area measurement is image of particle s size. Figure 8 show this resistance variation during the passage of two bacteria of different sizes. 346

Normalized repartition Proceedings of the 8th International Conference on Sensing Technology, Sep. 2-4, 2014, Liverpool, UK measurements was described and characterized. Two devices were manufactured using SU_8 resin and PDMS silicon polymer. Even if both were able to perform flow impedance spectroscopy, the device just using PDMS allows better performances and the possibility to efficiently clean it after multiple tests. Results obtained prove the ability of our device to detect and characterized particles and cells in less than 1ms, allowing the possibility to analyses up to several hundred cells per second. Repartition measured with beads show our system permits to detect very few impedance variations with a good precision and repetability. Figure 8. Resistance variation measured during the passage of two different cells As variations induced by the passage of cells are proportional to cell s sizes, we can prove the first particle is smaller than the second. The two pairs of electrodes measure the same variations, in order of 2 to 3 %, proving the ability of our system to measure small variations with good precision. Time detection is less than 1ms per microparticles, permitting to measure up to several hundred particles per second, in agreement with our assumptions. Second experimentations were accomplished using 6 µm polystyrene calibrated microbeads. Even if previous resistance variations can be used to compare particles sizes, we need calibrated particles to check if our measured variations agree with theory. For that, beads were diluted in the same buffer and measured in the same conditions than bacteria. For each detected bead, resistance variation was recorded. All results was compiled in a normalized repartition graphic giving in Fig. 9. The theoretical repartition was calculated using bead s datasheet and theoretical formulas, and represent the repartition guaranty by the manufacturer. For this reason, this repartition is always superior or equal to the reality. Our measurement are perfectly in concordance with the predictive variation, with a well centered repartition. 0.5 0.4 0.3 0.2 0.1 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 Impedance variation(en %) Measured Simulated ACKNOWLEDGMENT The authors gratefully thank the MINALOR skill center of Institut Jean Lamour (IJL) in University of Lorraine, for their technical support. REFERENCES [1] H. Song, Y. Wang, J.M. Rosano, B. Prabhakarpandian, C. Garson, K. Pant, E. Lai, A microfluidic impedance flow cytometer for identification of differentiation state of stem cells Lab on a Chip, 13(12), 2013, p.2300-2310 [2] C. Gabriel, S. Gabriel, and E. Corthout, The dielectric properties of biological tissues: I. Literature survey, Physics in Medicine and Biology, vol. 41, 1996, p. 2231. [3] S. Gabriel, R. Lau, et C. Gabriel, The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues, Physics in Medicine and Biology, vol. 41, 1996, p. 2271. [4] M.Ibrahim, J.Claudel, D.Kourtiche, M.Nadi, Geometric parameters optimization of planar interdigitated electrodes for bioimpedance spectroscopy." Journal of Electrical Bioimpedance 4.1 (2013): 13-22. [5] T. T. Ngo, H. Shirzadfar, D. Kourtiche, M. Nadi, A Planar Interdigital Sensor for Bio-impedance Measurement: Theoretical analysis, Optimization and Simulation, journal of Nano- and Electronic Physics, volume 6, 2014. [6] A. K. Bryan, A. Engler, A. Gulati, S. R. Manalis "Continuous and longterm volume measurements with a commercial coulter counter." PloS one 7.1, 2012: e29866. [7] S. Cho et H. Thielecke, Micro hole-based cell chip with impedance spectroscopy, Biosens. Bioelectron., vol. 22, n o 8, p. 1764 1768, 2007. [8] J. Claudel, M. Ibrahim, H. Shirzadfar, M. Nadi, O. Elmazria, D. Kourtiche Hybrid Microfluidic Biosensor for Single Cell Flow Impedance Spectroscopy: Theoretical Approach and First Validations. In XIII Mediterranean Conference on Medical and Biological Engineering and Computing 2013 (pp. 841-844). Springer International Publishing. [9] E.T. McAdams, A. Lackermeier, J.A. McLaughlin, D. Macken, et J. Jossinet, The linear and non-linear electrical properties of the electrodeelectrolyte interface, Biosensors and Bioelectronics, vol. 10, 1995, p. 67-74. [10] H. Fricke et S. Morse, The electric resistance and capacity of blood for frequencies between 800 and 4½ million cycles, The Journal of General Physiology, vol. 9, Nov. 1925, p. 153-167. [11] H. Morgan, T. Sun, D. Holmes, S. Gawad, et N.G. Green, Single cell dielectric spectroscopy, Journal of Physics D: Applied Physics, vol. 40, 2007, p. 61-70. Figure 9. Repartition of calibrated microbeads. Results from experimentation and simulation V. CONCLUSION A sensor based on impedance spectroscopy and microfluidic device, able to perform dynamic cells 347