Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Similar documents
Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Sample Prep Options for GC users

Accuracy Starts Here. Agilent Bond Elut Plexa and Polymeric SPE Selection Guide

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Guide to Peptide Quantitation. Agilent clinical research

[ Care and Use Manual ]

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

Agilent Products for Solid Phase Extraction. Improve the quality of your sample preparation so you can improve the quality of your analysis.

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Sample Preparation. Approaches to Automation for SPE

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

LC and LC/MS Column Selection Flow Chart

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Determination of Alkaloids in Goldenseal Using Agilent Bond Elut Plexa Solid Phase Extraction Sorbent for Cleanup and HPLC-DAD Analysis

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120

LC Technical Information

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9.

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

ProPac WCX-10 Columns

Simplify Sample Preparation [ SAMPLE PREPARATION SOLUTIONS ]

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Bulk Silica Gels. SiliaFlash Irregular Silica Gels SiliaSphere PC Spherical Silica Gels

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Automated Sample Preparation. Andrew Duggan, PhD Aman Sharma Shimadzu Scientific Australia

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Translational Biomarker Core

ABI 3200 Q TRAP LC/MS/MS System

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

Agilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

New Product Update. HPLC Columns

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Analytical Instrumentation

ENHANCING SOLID-PHASE DISK EXTRACTION PERFORMANCE WITH DESIGN OF EXPERIMENTS

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

EVOLUTE EXPRESS SPE Products. Load-Wash-Elute SPE Products

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Solid Phase Extraction Method Development Tips and Tricks

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for Sample Preparation

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Automating Gradient Method Development in Flash Chromatography For Greater Productivity and Minimizing Solvent Use

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

SPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver

IN QUALITATIVE ANALYSIS,

Ideal and powerful solution

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - CHROMABOND. Catalogue 9. Hichrom Limited

Definitive EtG/EtS LC-MS/MS Analysis:

High Performance Liquid Chromatography

GPC/SEC An essential tool for polymer analysis

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Quick and Simple Cleanup for. Medicinal Chemistry. It s BIG.

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

ChromegaChiral TM CSP Media and Columns

WALKUP LC/MS FOR PHARMACEUTICAL R&D

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Elecsys with ECL technology Still light years ahead

The Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

SGE is excited to launch a new HPLC product line under the ProteCol brand.

Thermo Scientific HyperSep Dispersive SPE Products. Efficient sample preparation and clean-up using the QuEChERS Method

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

separation of the cleaned extract in subgroups of compounds (PCDDs, PCDFs, PCBs) depending on their polarity and geometry. The fractions can then be a

Determination of 24 PAHs in Drinking Water

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

110 Lowell Rd Hudson, NH USA Tel:

Perseverance. Experimentation. Knowledge.

Bringing uhplc Performance to the Separation of Peptides

Liquid Chromatography

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

trust Sample Preparation Products

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

ZirChrom Columns and the Metalox 200-C High Temperature Liquid Chromatography Column Heater - The Future of HPLC has Arrived.

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Gemini-NX Performance paired with Axia Technology

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

A High Sensitivity Dual Solid Phase Extraction LC-MS/MS Assay for the Determination of the Therapeutic Peptide Desmopressin in Human Plasma

Transcription:

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications Agilent Bond Elut Plexa vs. Waters Oasis Sample Prep Products Reliability is a key parameter in developing rugged, highthroughput sample preparation methods. That is why Agilent Bond Elut Plexa SPE products combine innovative research, state-of-the art manufacturing, and stringent quality-control monitoring to deliver consistently fast flow rates and reproducible results. With Agilent Bond Elut Plexa SPE products, you can count on: Faster flow rates: Uniform particles with a narrow size distribution ensure optimal flow characteristics for sample addition and elution during solid-phase extraction. Excellent cartridge-to-cartridge reproducibility: Plexa sorbent particles are manufactured using proprietary polymerization techniques to eliminate fines and achieve a very narrow particle size distribution. Less wasted time and sample: The absence of sorbent fines significantly reduces cartridge clogging. This is critical in high-throughput laboratories, where SPE must be performed unattended and overnight. The elimination of fines also reduces the risk of frit blockage and sample loss an important prerequisite when analyzing biofluids. More reliable data: Proprietary automated fritting and realtime QC processes minimize channels (or voids) in the packed sorbent bed, preventing analyte breakthrough and variable recoveries. On the following pages, you ll fi nd a side-by-side comparison of Agilent Bond Elut Plexa and Waters Oasis Sample Prep Products

Agilent Bond Elut Plexa SPE products deliver unrivaled ease-of-use and reproducible flow. And here s the proof. Excellent particle integrity saves time and eases your workload As you can see in Figure 1, Agilent Bond Elut Plexa shows excellent particle integrity with no oversized, damaged, or fine particles. In contrast, the Waters polymer shows numerous broken particles and fines that may cause frit blockage and sample loss. A narrow particle size distribution improves flow rate and reduces the risk of blockage The comparison of particle size distributions in Figure 2 reflects a similar mean particle diameter for both the Agilent Bond Elut Plexa polymer and the Waters Oasis polymer. However, the Bond Elut Plexa has a Gaussian-type distribution, whereas the Waters polymer shows a broad distribution with broken particles and sub-10 µm fines. The consequences of a broader size distribution are slower flow rate, greater risk of blocked wells, and decreased precision (less reproducibility from cartridge-to-cartridge and well-to-well). Agilent Bond Elut Plexa Waters Oasis HLB Figure 1. Magnified image analysis was used to compare SPE polymer particle sizes 600 550 500 450 400 350 300 250 200 150 100 50 Agilent Bond Elut Plexa Polymers Plexa PCX Plexa 400 350 300 250 200 150 100 50 Waters Oasis Polymers Oasis MCX Oasis HLB 0 0 8 10 20 40 60 80 100 8 10 20 40 60 80 100 Particle Diameter (μm) Particle Diameter (μm) Figure 2. Particle size distribution comparison of polymeric SPE sorbents 2

Easy-to-use methods and general-purpose extraction protocols simplify your SPE Two polymer choices cover a broad range of analyte classes and properties Agilent Bond Elut Plexa (the non-polar polymer) is universally applicable, and is the best choice for extracting a wide range of acidic, neutral, and basic analytes from different matrices. Agilent Bond Elut Plexa PCX is a strong cation exchanger with mixed-mode sorbent characteristics, making it suitable for the extraction and clean-up of polar and non-polar bases from biofluids. Bond Elut Plexa PCX demonstrates the same excellent distribution and outstanding particle integrity as Bond Elut Plexa. Acids Neutrals Bases Analyte Log P > 1.5 pka 3-6 pka 6-10 Log P > 0.8 pka 6-10 Plexa Acid Load Method Plexa Base Load Method Plexa PCX Sample Treatment 1% HCO 2 H 2% NH 4 OH 2% H 3 PO 4 Sorbent Condition 100% MeOH 100% MeOH Equilibrate 100% H 2 0 100% H 2 0 Wash 5% MeOH in H 2 O 2% HCO 2 H in H 2 0 Elution 1 100% MeOH Acids 100% MeOH Neutrals 1:1 MeOH/ACN Elution 2 5% NH 3 in 1:1 MeOH/ACN Bases Figure 3. The general protocol for trouble-free SPE applications with Bond Elut Plexa and Bond Elut Plexa PCX To download the Agilent Bond Elut brochure, please visit www.agilent.com/chem/bondelutspe 3

Bond Elut Plexa designed for simplicity, improved analytical performance, and ease-of-use The Bond Elut Plexa Family is a new generation of polymeric SPE products. Its uniqueness lies in the novel hydroxylated exterior, hydrophobic interior and advanced polymeric architecture. Advanced Polymer Architecture Improves Extraction Performance Maximize flow rates and minimize clogging Figure 4 shows the practical effect of particle integrity on flow rates. To compare flow rates between Plexa PCX and Waters Oasis MCX polymeric sorbent, 12 wells were conditioned with 500 μl methanol followed by 500 μl of water. Plasma, diluted to 1:3 with phosphoric acid, was then added to every well, and a constant vacuum of -5 Hg was applied. The time was recorded, enabling flow rates to be calculated. 0.8 0.7 LOAD: Water-rich, hydrophilic surface allows excellent phase transfer of analytes into the polymer core. Large endogenous proteins do not bind to the surface of the polymer and cannot access pore structure. Analyte Pores Flow rate (ml/min) 0.6 0.5 0.4 0.3 0.2 0.1 0 1 2 3 4 5 6 7 8 9 10 11 12 Well Number WASH: Analytes that have crossed the hydrophilic layers will remain tightly bound in the hydrophobic core. Interferences wash away without leaching the analytes of interest. Agilent Bond Elut Plexa PCX Waters Oasis MCX Figure 4. Agilent Bond Elut Plexa PCX (left) demonstrates faster and more reproducible flow rates across a row of twelve rows in a 96 well plate mean flow rate for Plexa PCX = 0.47 ml/min (%RSD of flow = 24%), Waters Oasis MCX (right) mean flow rate = 0.27 ml/min (%RSD of flow = 38%) Typical properties Parameters Bond Elut Plexa Bond Elut Plexa PCX Pore size (nominal) 100 Å 100 Å ELUTE: Specially engineered pore structure allows excellent mass transfer out of the polymer. The results are superior extract cleanliness and high recoveries. Particle size 45 µm 45 µm Specific surface area m 2 /g 450 m 2 /g 450 m 2 /g ph range stability 1-14 1-14 Chemical resistance (solvents) Retention capacity / Ion exchange capacity Broad range of protic and non-protic polar and non-polar solvents 10% of sorbent mass* Broad range of protic and non-protic polar and non-polar solvents Cation exchange loading of 1.0 mmol/g (determined by elemental analysis of sulfur content) These properties are characteristic but do not constitute specifications *highly dependent on matrix type and specific analyte characteristics 4

Bond Elut Plexa Description Unit Part No. Straight Barrel Cartridges 30 mg, 1 ml 100/pk 12109301 30 mg, 3 ml 50/pk 12109303 60 mg, 1 ml 100/pk 12109601 60 mg, 3 ml 50/pk 12109603 200 mg, 3 ml 50/pk 12109610 200 mg, 6 ml 30/pk 12109206 500 mg, 3 ml 30/pk 12109703 500 mg, 6 ml 30/pk 12259506 Bond Elut Jr 300 mg, 6 ml 50/pk 12169610B Bond Elut 96 Round-well Plates 10 mg, 1 ml 1/pk A4969010 30 mg, 1 ml 1/pk A4969030 Bond Elut 96 Square-well Plates 10 mg, 2 ml 1/pk A3969010 30 mg, 2 ml 1/pk A3969030 Mega Bond Elut Plexa 500 mg, 12 ml 20/pk 327832 Bond Elut Plexa PCX Description Unit Part No. Straight Barrel Cartridges 30 mg, 1 ml 100/pk 12108301 60 mg, 1 ml 100/pk 12108601 30 mg, 3 ml 50/pk 12108303 60 mg, 3 ml 50/pk 12108603 200 mg, 6 ml 30/pk 12108206 500 mg, 6 ml 30/pk 12258506 Bond Elut 96 Round-well Plates 10 mg, 1 ml 1/pk A4968010 30 mg, 1 ml 1/pk A4968030 Bond Elut 96 Square-well Plates 10 mg, 1 ml 1/pk A3968010 30 mg, 1 ml 1/pk A3968030 To download the Agilent Bond Elut brochure, please visit www.agilent.com/chem/bondelutspe 5

Agilent LC/MS instruments, columns, and supplies: Unsurpassed for tough qualitative and quantitative analysis From best-in-class LC technologies... to MS spectral accuracy and precision... to TOF-MS systems that let you identify empirical formulas without a spectral library, Agilent LC/MS instruments help you perform discovery, quantitation, and target compound analysis with confidence. Our powerful data analysis tools and workflow productivity enhancements include: Jet Stream technology increases LC/MS and LC/MS/MS sensitivity five-fold by improving the spatial focusing of electrospray droplets. Maximum ion generation and transmission across a broad mass range ensure low detection limits and quantitation for the widest range of sample types. Automated method development and optimization: MassHunter Optimizer software automatically finds the best transitions for each compound and determines the optimal fragmentor voltage and collision energies. Agilent s LC/MS systems equip your lab to meet the quantitation and confirmation demands of today s emerging applications. 6

Agilent HPLC columns outlast the competition, and ensure a lifetime of peak performance From research to leading-edge method development to routine quality assurance, Agilent ZORBAX HPLC columns are optimized for high throughput analysis, and feature the sensitivity, accuracy, and reliability that demanding food applications require. For example, our new Poroshell 120 columns give you speed and resolution that are comparable to sub-2 micron columns. Because they use standard 2 micron frits, however, they resist plugging with complex food samples. Keep your methods safe, keep your productivity high, and keep contamination to a minimum MS Analyzed Vials Kits Agilent MS Analyzed Vials Kits end the need to pre-test or rerun samples due to unexpected peaks. The kits come with true lot-specific and traceable LC/MS & GC/MS testing results in a single package. LC Detector Lamps Don t risk your results to decreased accuracy, reproducibility, and reliability due to an ill-fitting or poorly made lamps in your high quality Agilent detector. Only Agilent lamps are designed and built to match Agilent instruments. PEEK or stainless steel LC tubing Agilent LC tubing eliminates dead volumes while making sure your connections are inert, tight, and leak-free Poroshell 120 columns give you speed and resolution similar to sub-2 micron columns; however, they use 2 micron frits, so they are more forgiving for food safety samples. As the world s leader in chromatography, Agilent is uniquely positioned to offer not only industry-leading instruments, but also the most innovative sample preparation tools, columns and supplies. All are engineered or selected by our experienced design teams, manufactured to our demanding specifications and tested under a variety of strict conditions. To learn more, visit www.agilent.com/chem/supplies To download the Agilent Bond Elut brochure, please visit www.agilent.com/chem/bondelutspe 7

The Bond Elut difference Heritage of reliability: With years of use in some of the most demanding analytical laboratories in the world, Bond Elut products have a proven track record resulting in a strong publication pedigree Options for your needs: Offering extraction solutions for the widest range of analytes and matrices, (over 40 bonded silica phases for high specificity methods and polymeric phases for rapid method development), Bond Elut has the largest choice of formats and sorbents in the market Innovative products designed for lab efficiency: Whether it be fast flow polymeric particles or our patented 96-well plate design, all Bond Elut products are created for ease of use and flexibility to meet both manual and automated requirements Technical support at every step: For your specific applications or to help solve occasional technical issues, a global team of analytical scientists are on hand to assist World class manufacturing and quality: Unrivalled manufacturing control, plus exacting ISO 9001: 2000 compliant inspections guarantee the consistent quality of Bond Elut Improve extraction performance and streamline method development with Agilent s new generation of polymeric SPE sorbent Traditional SPE sorbents contain a large number of fines, which can cause sample blockage and lead to a slow, variable flow of solvent and analyte through the sorbent bed. As a result, assay variability with respect to recovery rates will increase. In contrast, Agilent Bond Elut Plexa sorbent particles are nearly mono-dispersed in size, resulting in a very homogeneous packing, higher bed packing efficiency, and more consistent performance A highly controlled sulfonation process minimizes fines for Plexa PCX. Specifically designed for pharmaceutical bioanalysis, Agilent Bond Elut Plexa s advanced polymer technology delivers reproducible results with excellent recoveries and sharp elution profiles. These leading-edge SPE products are especially amenable to high-throughput or automated platforms, due to their excellent well-to-well and cartridge-to-cartridge flow reproducibility. For more information To learn more about Agilent Sample Preparation Products please visit www.agilent.com/chem/samplepreration Or call toll free 1-800-227-9770, option 3, then option 3 again (in the U.S. and Canada). In other countries, please call your local Agilent Representative or Agilent Authorized Distributor, visit www.agilent.com/chem/contactus This information is subject to change without notice. Agilent Technologies, Inc. 2011 Printed in the USA March 10, 2011 5990-7567EN