X: The Hall Effect in Metals

Similar documents
Lab 4: The Classical Hall Effect

EXPERIMENT 12 OHM S LAW

1. Electrostatic Lab [1]

EE301 RESISTANCE AND OHM S LAW

Evaluation copy. Ground Temperature Measurements. computer OBJECTIVES MATERIALS PRE-LAB QUESTIONS

Fig. 1. Two common types of van der Pauw samples: clover leaf and square. Each sample has four symmetrical electrical contacts.

PHY3901 PHY3905. Hall effect and semiconductors Laboratory protocol

Equipotential Lines and Electric Fields

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

Lab 6 - Electron Charge-To-Mass Ratio

PHY222 - Lab 7 RC Circuits: Charge Changing in Time Observing the way capacitors in RC circuits charge and discharge.

Last Revision: August,

Acid-Base Titration. Evaluation copy

Experiment The Hall Effect Physics 2150 Experiment No. 12 University of Colorado

Experiment 14 It s Snow Big Deal

THE HALL EFFECT AND CURRENT SENSORS. Experiment 3

Electric Field PHYS 296

Simple circuits - 3 hr

PHY222 Lab 8 - Magnetic Fields and Right Hand Rules Magnetic forces on wires, electron beams, coils; direction of magnetic field in a coil

Acid-Base Titration. Sample

Lab 5 - ELECTRON CHARGE-TO-MASS RATIO

Relativistic Electrons

Lab E3: The Wheatstone Bridge

In this experiment, the concept of electric field will be developed by

Introduction to Simple Harmonic Motion

University of TN Chattanooga Physics 1040L 8/18/2012 PHYSICS 1040L LAB LAB 4: R.C. TIME CONSTANT LAB

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS

Unit 8 Hall Effect. Keywords: The Hall Effect, The Magnetic Field, Lorentz Force

first name (print) last name (print) brock id (ab17cd) (lab date)

Answer Key. Chapter 23. c. What is the current through each resistor?

Materials Needed 1 D-Cell battery 6 6-inch pieces of wire 3 flashlight light bulbs 3 light bulb holders (optional)

EQUIPMENT Beta spectrometer, vacuum pump, Cs-137 source, Geiger-Muller (G-M) tube, scalar

SIMPLE D.C. CIRCUITS AND MEASUREMENTS Background

General Physics II Lab EM2 Capacitance and Electrostatic Energy

Lab 6 - ELECTRON CHARGE-TO-MASS RATIO

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1

Physics 476LW. Advanced Physics Laboratory - Faraday Rotation

Lab 7 - ELECTRON CHARGE-TO-MASS RATIO

Thevenin equivalent circuits

Fundamentals of Circuits I: Current Models, Batteries & Bulbs

Magnetic Fields INTRODUCTION. The Hall Effect

Kirchhoff s Rules and RC Circuits

Superconductivity. Never store liquid nitrogen in a container with a tight fitting lid.

Old Dominion University Physics 112N/227N/232N Lab Manual, 13 th Edition

SOTM LAB: P16 OHM S LAW I. TEACHER NOTES & GUIDELINES TITLE OF LAB: Ohm s Law DEVELOPERS OF LAB:

Introduction. Pre-Lab Questions: Physics 1CL PERIODIC MOTION - PART II Fall 2009

Experiment 1: The Same or Not The Same?

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

Lab 5 RC Circuits. What You Need To Know: Physics 212 Lab

Determining the K sp of Calcium Hydroxide

Electric Fields and Potentials

Figure 1: Capacitor circuit

Lab 8: Magnetic Fields

Physics 22: Homework 4

Electron charge-to-mass ratio

EXPERIMENT 9 Superconductivity & Ohm s Law

Lab 5 RC Circuits. What You Need To Know: Physics 212 Lab

UMEÅ UNIVERSITY Department of Physics Agnieszka Iwasiewicz Leif Hassmyr Ludvig Edman SOLID STATE PHYSICS HALL EFFECT

Establishing a Table of Reduction Potentials: Micro-Voltaic Cells. Evaluation copy

1 Written and composed by: Prof. Muhammad Ali Malik (M. Phil. Physics), Govt. Degree College, Naushera

Microscale Acid-Base Titration

The next two questions pertain to the situation described below. Consider a parallel plate capacitor with separation d:

The Magnetic Field of a Permanent Magnet. Evaluation copy

Electrochemistry and Concentration Effects on Electrode Potentials Prelab

Chapter 27. Current and Resistance

Electric Field and Electric Potential

You should be able to demonstrate and show your understanding of:

Experiment 6: Magnetic Force on a Current Carrying Wire

The Hall Effect. Figure 1: Geometry of the Hall probe [1]

Lab 4: Gauss Gun Conservation of Energy

Electricity. Measuring the force on current-carrying conductors in a homogeneous magnetic field. LEYBOLD Physics Leaflets P

Background Information for Use of Pitot Tube, Manometer, Hot Wires, and Hot Films

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Notebook Circuits With Metering. 22 February July 2009

Concepts in Physics Lab 9: Equipotential Lines

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department. Experiment 03: Work and Energy

Charge to Mass Ratio of The Electron

Empirical Gas Laws (Parts 1 and 2) Pressure-volume and pressure-temperature relationships in gases

Newton's Laws and Atwood's Machine

One Dimensional Collisions 1 Fall 2018

Conservation of Momentum Using PASCO TM Carts and Track to Study Collisions in One Dimension

2: SIMPLE HARMONIC MOTION

PhysicsAndMathsTutor.com

Physics 15b PSI Week 4: Magnetic Fields

Physics 476LW Advanced Physics Laboratory The Faraday Effect

The Determination of an Equilibrium Constant

Slide 1. Temperatures Light (Optoelectronics) Magnetic Fields Strain Pressure Displacement and Rotation Acceleration Electronic Sensors

Background The power radiated by a black body of temperature T, is given by the Stefan-Boltzmann Law

Physics (2) Laboratory manual

ACID-BASE TITRATION (MICROSCALE)

5. ELECTRIC CURRENTS

ECE 220 Laboratory 4 Volt Meter, Comparators, and Timer

Lab 3: Electric Field Mapping Lab

Conservation of Energy and Momentum

LAB 3: Capacitors & RC Circuits

Physics 326 Lab 6 10/18/04 DAMPED SIMPLE HARMONIC MOTION

7/06 Electric Fields and Energy

ENERGY AND TIME CONSTANTS IN RC CIRCUITS By: Iwana Loveu Student No Lab Section: 0003 Date: February 8, 2004

Ideal Gas Law and Absolute Zero

Part 2. Sensor and Transducer Instrument Selection Criteria (3 Hour)

Transcription:

X: The all Effect in Metals I. References C. Kittel: Introduction to Solid State Physics, pp. 148-151. Ashcroft and Mermin: Solid state Physics, pp. 6-15. Dekker: Solid State Physics, pp. 301-302. Yarwood: igh Vacuum Technique, pp. 1-38, 77-78; 81-83; 96-100; 150-158. II. Preparatory Questions (must be answered in lab book before eperiment is started and signed by instructor or TA) A. Answer Question A in section VII. (In the first part of the question, epress the answer as an algebraic relation between the quantity to be determined and the measured quantities.) Be sure that all numerical answers are labelled with the appropriate units. B. Assuming in the figure below that I = I and B = B z, show how a measurement of the sign of the all voltage, φ, gives the sign of the charge carriers. z y Ι C. Show how you could etract a value of R (or n) from plots of φ Η vs. B z and φ Η vs. I ; compare the accuracy of this method of obtaining R with that resulting from simply substituting values into the equation obtained in answer to Question A. Figure X-1 76

III. Purpose To use the all effect to show that an electric current passing through metallic silver is carried by electrons, and to determine the number density and mean drift velocity of these electrons. IV. Introduction The conductivity of a metal such as copper can be eplained on the basis of a free electron gas within the metal if these electrons are allowed to have collision with the atoms of the metal lattice. In this eperiment we determine that electrons are the charge carriers in metals. By measuring the sign of the charge carriers, their mean drift velocity and their number density can be determined based on the assumption that each carries a single electron charge. From the negative sign of the charge carrier and their number density, it is difficult to conceive of anything other than electrons as the charge carriers. This is consistent with other known eperimental results. V. Principles A. The all Effect When an electric charge q moves with velocity v in a magnetic field B the charge eperiences a force perpendicular to its direction of motion such that F = qv B X-1 Thus, in a slab of metal carrying an electric current I (Fig. X-1) the current density is j and if the current carriers have charge q j = nq v X-2 where n is the number density of charge carriers and <v > is their mean drift velocity in the -direction. If a magnetic field B z is applied in the z-direction some of the charge carriers will be deviated towards the shaded side of the slab (Fig. X-2) B z d t j z y Figure X-2 77

where the surface charge density will build up until the electric field repelling further charges from that surface is sufficient to counteract the force of the magnetic field, then qe = q v B X-3 The electric field developed by the surface charge density is known as the all field E, and the potential φ across the slab is the all voltage Z φ E d X-4 = Since for negative charge carriers, i.e., q negative, <v > is negative and therefore the shaded surface of the slab becomes negative while for positive charge carriers <v > is positive and the shaded surface becomes positive, the sign of the charge carriers can readily be determined. Further the magnitude of <v > can be determined from E v = X-5 BZ Then if the charge q is taken as one electron charge e, the density of charge carriers can be determined from Eq. X-2. For a given material, i.e., fied n and q, the all voltage φ depends only on the magnetic field B z and the current density j. Therefore to make φ a measurable voltage the current density must be made large. To achieve this high current density without the need for large sample currents (I = j d t), the thickness t of the slab of metal is made very small (~1000 Å) by using a thin film of the metal. B. The Production of Thin Films Thin films of thickness approimately 1000 Å are etremely fragile and although they can be made free of a substrate, usually in the form of a skin stretched on a supporting frame, they are very difficult to handle in that form. For this eperiment it is advantageous to have the metal film closely attached to a substantial nonconducting substrate, partly because this allows several independent electrical connections to be made to the film and partly as a means of removing any heat developed in the metal film by ohmic heating. At the same time a very pure, clean and uniform metal film can be made by evaporating the metal under vacuum onto a clean glass substrate (microscope slide). See the Laboratory Staff for eplicit instructions on how to evaporate the metal film, and how to measure the thickness of the sample. VI. Eperimental Procedure The preparation and production of the thin silver film used in this eperiment, the setting-up of the measuring system, the recording of data, and the measurement of the film thickness can all be completed in a four-hour laboratory period providing one is adequately prepared. There is no convenient point to divide the eperiment to 78

spread it out over two laboratory periods due to the rapid oidation of the silver films. Instrumentation Amplifier Voltmeter ρ ;;; Silver Sample l d Microvoltmeter Instrumentation Amplifier Voltmeter s R s =1 I + Battery Variable Resistance Bo to Control I Figure X-3 In the first lab period, be sure that you have completed the prelab questions so that you have an estimate of the quantities you ll be determining in this eperiment. You should also take some time to familiarize yourself with the vacuum system and the procedure for making a thin film. The meters used in this eperiment (particularly the micro voltmeter) are very sensitive and subject both to small drifts and to noise pickup and you should consider ways to minimize these effects as you collect data. In the second lab period make a second evaporation of the silver and proceed with the full set of measurements. A. Making the Measurements A small electromagnet (E.S.I. Model #4 F) provides the B z field. It has 4-inch pole pieces with a 0.69 inch gap and produces 4000 gauss with the maimum permissible current of 15 amps. A all-probe gauss meter is used to measure its output. Be careful not to wear a wristwatch or to place steel objects near the magnet: 4000 gauss is a surprisingly strong magnetic field. 79

B. Connections to record the all Effect voltage output: The following connections will permit you to simultaneously record the output of the Gauss meter, the micro voltmeter and the voltages φ ρ and φs. Connect the circuit shown in Fig. X-3 and insert the all-effect sample holder between the magnet pole pieces. Note that a Lab Pro, data acquisition system, has been added to this eperiment to ease the data taking in this eperiment. The gaussmeter and micro-voltmeter used in this eperiment have analog outputs. Connect channels one and two of the Lab Pro to these outputs. Two Instrumentation Amplifiers connected to channels three and four of the Lab Pro will be used to measure φ ρ and φs. Note: the analog output from any device may be different from the actual value displayed on the instrument. The relationship between these should be noted and recorded for later data analysis. Also be sure to carefully adjust the zeros of the meters and the LabPro inputs prior to collecting data. C. Computer acquisition of the data using the program Logger Pro: You are now ready to run the computer program Logger Pro which will permit you to record the data collected by the Lab Pro. 1. Select the folder on the computer desktop labeled Lab_Pro_Templates. This folder contains Logger Pro templates designed for the Phys 405 lab eperiments. Selecting one of these templates starts the program Logger Pro and loads the setup information for the eperiment selected. The following information is stored in the Logger Pro template. The Lab Pro will collect data from 4 analog channels. Channel 1 Voltage Probe. Channel 1 is set to collect data from the analog output of the Gauss Meter and display this data in a table and as a graph. Channel 2 Voltage Probe. Channel 2 is set to collect data from the analog output of the Micro voltmeter and display this data in a table and as a graph. Channel 3 (Instrumentation Amplifier with Gain setting +/- 20millivolt) is set to collect data and display this data in the table and on the graph. Channel 4 (Instrumentation Amplifier with Gain setting +/- 20millivolt) is set to collect data and display this data in the table and on the graph. The Data Collection sampling rate is set to 10 samples (measurements) per second. The Data Collection Length has been set to 15 seconds. 2. Zero the instruments. Make sure battery is disconnected so no current is flowing in the circuit. Place the gauss meter probe is in the Zero Gauss Chamber and press the zero button on the gauss meter. Adjust the zero controls on the micro voltmeter until its display is at zero. From the tool bar in Logger Pro, press the Zero button and select 80

OK to zero all sensors. This zeros, or aligns, Logger Pro and the Lab Pro with the sensors. 3. Click on the Collect button and the data collection should start. A live display will appear on the computer screen. Measuring small currents always calls for care. The micro voltmeter is delicate and should always be kept on scale. Keep it on its least sensitive scale when not using it. You must minimize movement near the circuit when measuring as you can induce currents and voltages even in shielded cable. Note that the Instrumentation Amplifier has several range settings. It is important to note that if a different range setting is selected (default +/- 20 mvolt), the calibration for the amplifier must be changed to reflect this change. From the Logger Pro toolbar menu, select Eperiment. From the list displayed move the curser to calibrate and the three sensors used in this eperiment will be displayed. Select the Instrumentation Amplifier, and in the Current Calibration bo, select the range setting that you have chosen. Once the range of the amplifier has been changed and the calibration set, it is important to zero the Instrumentation Amplifier. Using current of no more than 100 ma, take enough data to plot at least two curves for φ against I for two different magnetic field settings, and at least two curves for φ against B z using different I. Sufficient data (typically around 10 points) should be taken to define each of the curves. Also, determine the resistivity ρ of your silver sample, and compare this with the accepted bulk value given for Ag in some of the references. Attempt to eplain any discrepancies between your value and the accepted value. This may be done by measuring the potential drop φ ρ along a measured length of the silver sample using the potentiometer. From your data, and the measured size of the sample, determine the sign of the charge carriers and their number density assuming each is slightly charged. Use Figures X-2 and X-3 to compute the all coefficient for silver, R, where R is defined from the relation ( j B ) E = R, X-6 and compare with the theoretically accepted value. Many spurious effects can cause signals which are large compared to the true all voltage. The contacts used to measure the all voltage may not be eactly opposite each other, so what is measured is actually the true all voltage plus part of the voltage drop along the film due to I. Also, the current I may not be uniform over the film, or eactly parallel to the length of the film. Be absolutely sure you are measuring the real effect, which is dependent on both I and B z. When you have successfully finished all the required measurements on your all Effect sample, proceed with the measurement of the film thickness t. You will need to make an appointment with the Laboratory staff to use the DEKTAK film thickness measurement apparatus. This measurement is necessary before R and ρ can be calculated, but it is best left until this time in case the all effect sample is damaged during the setting-up procedure, in which case a second all effect sample and a new monitor will have to be made. z 81

VII. Discussion Questions (to be answered in lab report) A. Measurements made in this eperiment are 1. all voltage φ 2. Magnetic field B z 3. Voltage drop across the standard resistor R s, φ S 4. Voltage drop along the silver sample φ ρ 5. The dimensions of the sample, d, t, and. ow can these measurements be used to determine the number density of charge carriers, n, the mean drift velocity <v >, and the resistivity of silver ρ? If B z = 2000 gauss R s = 1Ω and φ S = 100 mv φ = 20 10-6 volts φ ρ = 0.1 volts d = 1 cm; = 2 cm; t = 1000 Å what are ρ, n, <v > and R? B. Briefly describe the methods of operation of an oil-sealed rotary vacuum pump and an oil diffusion pump. C. Describe very briefly: 1) the ionization gauge, 2) the thermocouple gauge. Which is an absolute pressure gauge? VIII. Possible Procedure Check List 1. Complete Prelab and get instructors permission to start eperiment. 2. Learn about Vacuum systems; read Appendi A of lab manual. 3. Receive verbal instructions on proper operation of the vacuum system from Laboratory Staff. 4. Turn on vacuum system. 5. Remove Bell Jar and load Ag wire into filament. Install cleaned glass slide into holder. 6. Evaporate silver film on to glass slide. 7. Carefully load test sample (glass slide) in to holder. 8. Connect circuit, measuring instruments, and data collection system. 9. Take all measurements. 10. If (9) is successful, make film thickness measurement on the sample (glass slide). 11. Turn off vacuum system. 82