Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

Similar documents
Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

Chromotropic Acid Method Method to 30.0 mg/l NO 3 N (HR) Test N Tube Vials

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

Chromium, Total. Alkaline Hypobromite Oxidation Method 1 Method to 0.70 mg/l Cr (spectrophotometers) 0.01 to 0.60 mg/l Cr (colorimeters)

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

Powder Pillows 0.01 to 0.80 mg/l Al 3+ (colorimeters)

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 1900 DR 5000 DR The fill line is to the right.

Nitrogen, Total Inorganic

Mercuric Thiocyanate Method Method to 25.0 mg/l Cl Reagent Solution

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 5000 DR The fill line is to the right.

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Chloramine (Mono) and Nitrogen, Free Ammonia

Phosphorus, Total. USEPA 1 PhosVer 3 with Acid Persulfate Digestion Method Method to 3.50 mg/l PO. Test preparation

Powder Pillows 0.01 to 1.60 mg/l SiO 2 (LR, colorimeters)

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

DR/4000 PROCEDURE NITRATE. 2. The display will show:

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 1900 DR 5000 DR The fill line is to the right.

Persulfate Digestion Method Method to 40 mg/l N (HR) TNTplus 827

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Chlorphosphonazo Colorimetric Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Solution Pillow. Instrument Adapter Sample cell

Cadion Method Method to 0.30 mg/l Cd TNTplus 852

PAR Method Method to 2.0 mg/l Pb TNTplus 850

Chromazurol S Method Method to 0.50 mg/l Al TNTplus 848

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

Dimethylphenol Method Method to mg/l NO 3 N or 1.00 to mg/l NO

Method to 0.50 mg/l NH 3 N Powder Pillows

Method to 0.50 mg/l NH 3 N Powder Pillows

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Cadmium Reduction Method (Using Powder Pillows or AccuVac Ampuls)

Chlorine, Free and Total, High Range

Peracetic Acid (PAA) and Hydrogen Peroxide (H 2 O 2 )

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows

Chlorine, Free and Total, Low Range

Oxygen Demand, Chemical

Oxygen Demand, Chemical

Chlorine, Free and Total, High Range

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Phenolphthalein and Total Alkalinity Method to 4000 mg/l as CaCO 3 Digital Titrator

Scope and application: For wastewater, seawater, drinking water, surface water and process water.

DR/4000 PROCEDURE. IRON, Total

1,5-Diphenylcarbohydrazide Method* Powder Pillows or AccuVac Ampuls (0 to mg/l Cr 6+ )

Method 8326 (0.006 to mg/l Al 3+ ) Powder Pillows

Chlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting.

PAR Method Method to 2.0 mg/l Pb TNTplus 850

Trihalomethane Formation Potential (THMFP)

NITRITE, Low Range (0 to mg/l NO 2- -N)

CHLORINE, TOTAL (0 to 4.00 mg/l)

Quaternary Ammonium Compounds

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832

Sulfide DOC Methylene Blue Method 1 (0 0.70, and mg/l) Method Test procedure

Mercaptoacetic Acid Method*

DR/4000 QUATERNARY AMMONIUM COMPOUNDS PROCEDURE. 2. The display will show: 3. Fill a sample cell (the blank) with 25 ml of deionized water.

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

DR/4000 PROCEDURE LEAD. 2. The display will show: 3. Fill a 250-mL graduated cylinder to the 250-mL mark with sample.

TPH (Total Petroleum Hydrocarbons)

NITROGEN, AMMONIA, High Range, Test N Tube

DR/4000 PROCEDURE. HARDNESS, Total

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ).

Method (0.04 to 4.50 mg/l Cl 2 ) Powder Pillows

NITROGEN, TOTAL, HR, Test N Tube

Polychlorinated Biphenyls (PCB) in Soil

DPD Test N Tube Method *

NITROGEN, TOTAL, Test N Tube * Method 10071

SILICA, Low Range (0 to 1.60 mg/l)

CHLORINE, FREE, Ultra-high Range ( mg/l Cl 2 ) Method 10069

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

DR/4000 PROCEDURE CYANIDE. 1. Press the soft key under HACH PROGRAM. Select the stored program for cyanide by pressing 1750 with the numeric keys.

p-dimethylaminobenzaldehyde Method*

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

DR/4000 PROCEDURE MERCURY. Phase 1: Sample Digestion must be done in a fume hood! Toxic gases may be produced.

Manganese III Digestion Method * (with chloride removal)

METHOD 9200 NITRATE. 1.2 The applicable range of concentration is 0.1 to 2 mg NO -N per liter. 3 of sample.

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

ALLOWAY METHOD OUTLINE

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

Sample Preparation LCW 909. Total Kjeldahl Nitrogen, TKN NB: NEW! LCW 909 GB

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

SIDE BY SIDE COMPARISON TABLE FOR HACH METHOD NUMBER COLORIMETRIC DETERMINATION OF CYANIDE

Steam-Assisted Gravity Drainage Water Analysis Handbook

Steam-Assisted Gravity Drainage Water Analysis Handook

Experiment 5: Analysis of Nutrients in Natural Waters CH3600 / ESP 5090: Environmental Chemistry, Plymouth State University

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

Nitrate plus Nitrite and Nitrite in Seawater by Segmented Flow Analysis (SFA)

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

METHOD 7B - DETERMINATION OF NITROGEN OXIDE EMISSIONS FROM STATIONARY SOURCES (ULTRAVIOLET SPECTROPHOTOMETRIC METHOD)

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

ASCORBIC ACID METHOD FOR PHOSPHORUS DETERMINATION

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

Standard Operating Procedure for: Conductivity Using Cole-Parmer Traceable Portable Conductivity Meter. Missouri State University.

METHOD 9012 TOTAL AND AMENABLE CYANIDE (COLORIMETRIC, AUTOMATED UV)

Sodium Chloride - Analytical Standard

ASTM Designation: D Standard Test Method for Determination of Iodine Number of Activated Carbon

METHOD #: Approved for NPDES and SDWA (Ed. Rev. 1974, 1978) Fluoride, Total (Colorimetric, SPADNS with Bellack Distillation)

National standard of People s Republic of China

L Mott SALT WATER AQUACULTURE. Model AQ-4/AQ-5 Code / test kit instruction manual

Transcription:

Nitrate, MR DOC316.53.01069 Cadmium Reduction Method Method 8171 0.1 to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters) Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific information Powder Pillows or AccuVac Ampuls The tables in this section show all of the instruments that have the program for this test. Table 1 shows sample cell and orientation requirements for reagent addition tests, such as powder pillow or bulk reagent tests. Table 2 shows sample cell and adapter requirements for AccuVac Ampul tests. To use either table, select an instrument, then read across to find the corresponding information for this test. Table 1 Instrument-specific information for powder pillows Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 5000 DR 3900 The fill line is to the right. 2495402 The fill line is toward the user. DR 900 The orientation mark is toward the user. 2401906 Table 2 Instrument-specific information for AccuVac Ampuls Instrument Adapter Sample cell DR 6000 DR 5000 DR 900 DR 3900 DR 3800 DR 2800 DR 2700 2427606 LZV846 (A) LZV584 (C) 2122800 Before starting Install the instrument cap on the DR 900 cell holder before ZERO or READ is pushed. For best results, measure the reagent blank value for each new lot of reagent. Replace the sample with deionized water in the test procedure to get the reagent blank value. Subtract the reagent blank value from the sample results automatically with the reagent blank adjust option. 1

This method is technique-sensitive. Shaking time and technique influence the color development. For most accurate results, use a standard solution that is within the test range and run the test several times. Increase or decrease the shaking time to get the expected result. Use the adjusted shaking time for sample measurements. The reagents that are used in this test contain cadmium. Rinse the sample cell immediately after use to remove all cadmium particles. Collect the reacted samples for proper disposal. A deposit of unoxidized metal will remain at the bottom of the sample cell after the reagent dissolves. The deposit will not affect results. Review the Safety Data Sheets (MSDS/SDS) for the chemicals that are used and use any recommended personal protective equipment. Dispose of reacted solutions according to local, state and federal regulations. Use the Safety Data Sheets for disposal information for unused reagents. Consult the environmental, health and safety staff for your facility and/or local regulatory agencies for further disposal information. Items to collect Powder pillows Description Quantity NitraVer Nitrate 5 Reagent powder pillow, 10-mL 1 Sample cells (For information about sample cells, adapters or light shields, refer to Instrumentspecific information on page 1.) 2 Stopper, Neoprene #1 2 Refer to Consumables and replacement items on page 7 for reorder information. AccuVac Ampuls Description Quantity NitraVer Nitrate 5 Reagent AccuVac Ampul 1 Beaker, 50 ml 1 Stoppers for 18-mm tubes and AccuVac Ampuls 1 Sample cells (For information about sample cells, adapters or light shields, refer to Instrumentspecific information on page 1.) 1 Refer to Consumables and replacement items on page 7 for reorder information. Sample collection and storage Collect samples in clean glass or plastic bottles. Analyze the samples as soon as possible for best results. If prompt analysis is not possible, immediately filter and keep the samples at or below 6 C (43 F) for a maximum of 48 hours. To preserve samples for up to 28 days, adjust the sample ph to 2 or less with concentrated sulfuric acid (about 2 ml per liter) and keep at or below 6 C (43 F). The test results then include nitrate and nitrite. Let the sample temperature increase to room temperature before analysis. Before analysis, adjust the ph to 7 with 5.0 N sodium hydroxide standard solution. Correct the test result for the dilution from the volume additions. 2 Nitrate, Cadmium Reduction Method (10.0 mg/l)

Powder pillow procedure Start 1. Start program 353 N, Nitrate MR PP. For information about sample cells, adapters or light shields, refer to Instrumentspecific information on page 1. 2. Prepare the sample: Fill a sample cell with 10 ml of sample. 3. Add the contents of one powder pillow to the sample cell. 4. Start the instrument timer. A 1-minute reaction time starts. Note: Although the program name may vary between instruments, the program number does not change. 5. Close the sample cell. Shake the sample cell vigorously until the timer expires. Some solid material will not dissolve. Undissolved powder will not affect results. 6. Start the instrument timer. A 5-minute reaction time starts. An amber color shows if nitrate is present. 7. Prepare the blank: Fill a second sample cell with 10 ml of sample. 8. When the timer expires, clean the blank. Zero 9. Insert the blank into the cell holder. 10. Push ZERO. The display shows 0.0 mg/l NO 3 N. 11. Clean the prepared sample. 12. Within 2 minutes after the timer expires, insert the prepared sample into the cell holder. Nitrate, Cadmium Reduction Method (10.0 mg/l) 3

Read 13. Push READ. Results show in mg/l NO 3 N. AccuVac Ampul procedure Start 1. Start program 359 N, Nitrate MR AV. For information about sample cells, adapters or light shields, refer to Instrumentspecific information on page 1. 2. Prepare the blank: Fill the sample cell with 10 ml of sample. 3. Prepare the sample: Collect at least 40 ml of sample in a 50-mL beaker. Fill the AccuVac Ampul with sample. Keep the tip immersed while the Ampul fills completely. 4. Start the instrument timer. A 1-minute reaction time starts. Note: Although the program name may vary between instruments, the program number does not change. 5. Use a stopper to close the Ampul tip. Invert the Ampul 48 52 times as the timer counts down. 6. Start the instrument timer. A 5-minute reaction time starts. An amber color shows if nitrate is present. 7. When the timer expires, clean the blank. 8. Insert the blank into the cell holder. 4 Nitrate, Cadmium Reduction Method (10.0 mg/l)

Zero Read 9. Push ZERO. The display shows 0.0 mg/l NO 3 N. 10. Clean the AccuVac Ampul. 11. Within 2 minutes after the timer expires, insert the prepared sample AccuVac Ampul into the cell holder. 12. Push READ. Results show in mg/l NO 3 N. Interferences Interfering substance Chloride Ferric iron Nitrite Interference level Chloride concentrations above 100 mg/l cause low results. The test can be used at high chloride concentrations (seawater) if a calibration is made with standards that have the same chloride concentration as the samples (refer to Seawater calibration on page 5). Interferes at all levels Interferes at all levels Compensate for nitrite interference as follows: 1. Add 30-g/L Bromine Water by drops to the sample until a yellow color remains. 2. Add one drop of 30-g/L Phenol Solution to remove the color. 3. Use the test procedure to measure the concentration of the treated sample. Report the results as total nitrate and nitrite. Highly buffered samples or extreme sample ph Strong oxidizing and reducing substances Can prevent the correct ph adjustment of the sample by the reagents. Sample pretreatment may be necessary. Interfere at all levels Seawater calibration Chloride concentrations above 100 mg/l cause low results. To use this method for samples with high chloride concentrations, calibrate the instrument with nitrate standard solutions that contain the same amount of chloride as the samples. Prepare calibration standards that contain chloride and 1.0, 3.0, 5.0 and 10.0 mg/l nitrate (as NO 3 N) as follows: 1. Prepare 1 liter of chloride water that has the same chloride concentration as the samples. a. Weigh the applicable amount of ACS-grade sodium chloride: (chloride concentration of samples in g/l) x (1.6485) = g of NaCl per liter. Note: 18.8 g/l is the typical chloride concentration of seawater. b. Add the sodium chloride to a 1-liter volumetric flask. c. Dilute to the mark with deionized water. Mix thoroughly. Use this water as the dilution water to prepare the nitrate standard solutions. 2. Use a pipet to add 1.0, 3.0, 5.0 and 10.0 ml of a 100 mg/l nitrate-nitrogen (NO 3 N) standard solution into four different 100-mL Class A volumetric flasks. 3. Dilute to the mark with the prepared chloride water. Mix thoroughly. 4. Complete the test procedure for each of the standard solutions and for the prepared chloride water (for a 0-mg/L standard solution). Nitrate, Cadmium Reduction Method (10.0 mg/l) 5

5. Measure the absorbance of the standard solutions and enter a user calibration into the instrument. 6. Use the user program to measure samples that contain high concentrations of chloride. Accuracy check Standard additions method (sample spike) Use the standard additions method (for applicable instruments) to validate the test procedure, reagents and instrument and to find if there is an interference in the sample. Items to collect: Nitrate Nitrogen Standard Solution, 100 mg/l NO 3 N Ampule breaker Pipet, TenSette, 0.1 1.0 ml and tips 1. Use the test procedure to measure the concentration of the sample, then keep the (unspiked) sample in the instrument. 2. Go to the Standard Additions option in the instrument menu. 3. Select the values for standard concentration, sample volume and spike volumes. 4. Open the standard solution. 5. Prepare three spiked samples: use the TenSette pipet to add 0.1 ml, 0.2 ml and 0.3 ml of the standard solution, respectively, to three 10-mL portions of fresh sample. Mix well. Note: For AccuVac Ampuls, add 0.1 ml, 0.2 ml and 0.3 ml of a 500 mg/l NO 3 N standard solution to three 50-mL portions of fresh sample. 6. Use the test procedure to measure the concentration of each of the spiked samples. Start with the smallest sample spike. Measure each of the spiked samples in the instrument. 7. Select Graph to compare the expected results to the actual results. Note: If the actual results are significantly different from the expected results, make sure that the sample volumes and sample spikes are measured accurately. The sample volumes and sample spikes that are used should agree with the selections in the standard additions menu. If the results are not within acceptable limits, the sample may contain an interference. Standard solution method Use the standard solution method to validate the test procedure, reagents and instrument. Items to collect: Nitrate Nitrogen Standard Solution, 100 mg/l NO 3 N 100-mL volumetric flask, Class A 5-mL volumetric pipet, Class A and pipet filler Deionized water 1. Prepare a 5.0 mg/l nitrate-nitrogen standard solution as follows: a. Use a pipet to add 5.0 ml of 100 mg/l nitrate-nitrogen standard solution into the volumetric flask. b. Dilute to the mark with deionized water. Mix well. Prepare this solution daily. 2. Use the test procedure to measure the concentration of the prepared standard solution. 3. Compare the expected result to the actual result. Note: The factory calibration can be adjusted slightly with the standard adjust option so that the instrument shows the expected value of the standard solution. The adjusted calibration is then used for all test results. This adjustment can increase the test accuracy when there are slight variations in the reagents or instruments. 6 Nitrate, Cadmium Reduction Method (10.0 mg/l)

Method performance The method performance data that follows was derived from laboratory tests that were measured on a spectrophotometer during ideal test conditions. Users may get different results under different test conditions. Program Standard Precision (95% Confidence Interval) Sensitivity Concentration change per 0.010 Abs change 353 5.0 mg/l NO 3 N 4.8 5.2 mg/l NO 3 N 0.04 mg/l NO 3 N 359 5.0 mg/l NO 3 N 4.6 5.4 mg/l NO 3 N 0.05 mg/l NO 3 N Summary of method Cadmium metal reduces nitrate in the sample to nitrite. The nitrite ion reacts in an acidic medium with sulfanilic acid to form an intermediate diazonium salt. The salt couples with gentisic acid to form an amber colored solution. The measurement wavelength is 400 nm for spectrophotometers or 420 nm for colorimeters. Pollution prevention and waste management Reacted samples contain cadmium and must be disposed of as a hazardous waste. Dispose of reacted solutions according to local, state and federal regulations. Consumables and replacement items Required reagents Description Quantity/test Unit Item no. NitraVer 5 Nitrate Reagent Powder Pillows, 10-mL 1 100/pkg 2106169 OR NitraVer 5 Nitrate Reagent AccuVac Ampul 1 25/pkg 2511025 Required apparatus for powder pillows Description Quantity/test Unit Item no. Stopper, Neoprene, solid, size #2 2 12/pkg 1480802 Required apparatus for AccuVac Ampuls Description Quantity/test Unit Item no. Beaker, 50-mL 1 each 50041H Stoppers for 18-mm tubes and AccuVac Ampuls 2 6/pkg 173106 Recommended standards Description Unit Item no. Drinking Water Standard, Mixed Parameter, Inorganic for F -, NO 3, PO 4, SO 4 500 ml 2833049 Nitrate Nitrogen Standard Solution, 100-mg/L NH 3 -N 500 ml 194749 Nitrate Nitrogen Standard Solution, Voluette Ampule, 500-mg/L NO 3 N 16/pkg 1426010 Optional reagents and apparatus Description Unit Item no. Bromine Water, 30 g/l 29 ml 221120 Cylinder, mixing, 50-mL each 2088641 Nitrate, Cadmium Reduction Method (10.0 mg/l) 7

Consumables and replacement items (continued) Description Unit Item no. Flask, volumetric, Class A, 100-mL each 1457442 Pipet, TenSette, 0.1 1.0 ml each 1970001 Pipet tips for TenSette Pipet 1970001 50/pkg 2185696 Pipet tips for TenSette Pipet 1970001 1000/pkg 2185628 Pipet, volumetric 5.00-mL each 1451537 Pipet filler, safety bulb each 1465100 Phenol Solution, 30-g/L 29 ml 211220 Sodium Hydroxide Standard Solution, 5.0 N 1 L 245053 Sulfuric Acid, concentrated, ACS 500 ml 97949 Water, deionized 4 L 27256 FOR TECHNICAL ASSISTANCE, PRICE INFORMATION AND ORDERING: In the U.S.A. Call toll-free 800-227-4224 Outside the U.S.A. Contact the HACH office or distributor serving you. On the Worldwide Web www.hach.com; E-mail techhelp@hach.com HACH COMPANY WORLD HEADQUARTERS Telephone: (970) 669-3050 FAX: (970) 669-2932 Hach Company/Hach Lange GmbH, 1989 2013. All rights reserved. 04/2013, Edition 8