Air Fluorescence Photon Yield In Cosmic Ray Showers

Similar documents
AIRFLY: Measurement of the Air Fluorescence induced by electrons

A measurement of the air fluorescence yield

arxiv: v1 [astro-ph] 30 Jul 2008

The air fluorescence yield. Fernando Arqueros Universidad Complutense de Madrid Spain

John Ellison University of California, Riverside. Quarknet 2008 at UCR

Senior Design Proposal

FLASH. FLuorescence in Air from SHowers (SLAC E-165) Pisin Chen SLAC. Report to DOE HEP Review SLAC, June 2-4, 2004

Direct WIMP Detection in Double-Phase Xenon TPCs

Measurements of the Fluorescence Light Yield in Electromagnetic Showers

Measurements of Liquid Scintillator Light Yield for Future Neutrino Experiments

Radiation (Particle) Detection and Measurement

arxiv: v1 [physics.ins-det] 3 Feb 2011

PoS(ICRC2015)641. Cloud Monitoring using Nitrogen Laser for LHAASO Experiment. Z.D. Sun 1,Y. Zhang 2,F.R. Zhu 1 for the LHAASO Collaboration

On the energy deposition by electrons in air and the accurate determination of the air-fluorescence yield

Ultra-High-Energy Cosmic Rays: A Tale of Two Observatories

LAAPD Performance Measurements in Liquid Xenon

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Measurement of Muon Lifetime

arxiv:physics/ v1 3 Aug 2006

Particle Energy Loss in Matter

Astroparticle Physics

The Cosmic Ray Air Fluorescence Fresnel lens Telescope (CRAFFT) for the next generation UHECR observatory

Detection and measurement of gamma-radiation by gammaspectroscopy

[CRI299] SFLASH: Absolute Measurement of Fluorescence Yield from Shower Particles

Particle Energy Loss in Matter

Absolute measurement of the nitrogen fluorescence yield in air between 300 and 430 nm.

Precise Measurement of the Absolute Yield of Fluorescence Photons in Atmospheric Gases

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

An introduction to AERA. An Introduction to the Auger Engineering Radio Array (AERA)

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

On the energy deposition by electrons in air and the accurate determination of the air-fluorescence yield

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment

Mass Composition Study at the Pierre Auger Observatory

Fluorescence Measurements at ANL and the Auger Experiment

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

Measuring Cosmic Ray Muon Decay Constant and Flux

Quantum Efficiency Measurements of Dark Matter PMT

PoS(PD07)031. General performance of the IceCube detector and the calibration results

A Gaussian Fitter for the CESR-c Fast Luminosity Monitor

David Gascón. Daniel Peralta. Universitat de Barcelona, ECM department. E Diagonal 647 (Barcelona) IFAE, Universitat Aut onoma de Barcelona

UHE Cosmic Rays in the Auger Era

Assembly and test runs of decay detector for ISGMR study. J. Button, R. Polis, C. Canahui, Krishichayan, Y. -W. Lui, and D. H.

PHYS 3650L - Modern Physics Laboratory

Ultrahigh Energy cosmic rays II

Multi-PMT Optical Module Designs for IceCube-Gen2

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

Water Cherenkov Detector installation by the Vertical Muon Equivalent technique

Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data

AugerPrime. Primary cosmic ray identification for the next 10 years. Radomír Šmída.

Analysis of Errors Due to Aerosols at the Pierre Auger Observatory. Jeremy P. Lopez Advisor: Stefan Westerhoff Nevis Labs, Columbia U.

Radioactivity. Lecture 6 Detectors and Instrumentation

GRB detection at ground level using Water Cerenkov Tanks

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007

object objective lens eyepiece lens

Timing calibration of the LHAASO-KM2A electromagnetic particle detectors

Dark Matter Detection and PMT Base Optimization

Parameters Sensitive to the Mass Composition of Cosmic Rays and Their Application at the Pierre Auger Observatory

Some Thoughts on Laboratory Astrophysics for UHE Cosmic Rays. Pierre Sokolsky University of Utah SABRE Workshop SLAC, March, 2006

SCINTILLATORS AND WAVELENGTH SHIFTERS FOR THE DETECTION OF IONIZING RADIATION *

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

Counting Photons to Calibrate a Photometer for Stellar Intensity Interferometry

Synthesis of plastic scintillator. Ildefonso León Monzón Universidad Autónoma de Sinaloa

Position-sensitive SiPM detector for separation of Cherenkov and fluorescent light of EAS

Interaction of charged particles and photons with matter

Neutral particles energy spectra for 900 GeV and 7 TeV p-p collisions, measured by the LHCf experiment

GEANT4 Simulation of Pion Detectors for the MOLLER Experiment

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

Study of Isospin simmetry using the PARIS detector. Alice Mentana

GEANT4 simulation about the laboratory astrophysics in Taiwan

Detecting High Energy Cosmic Rays with LOFAR

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

A method to measure transit time spread of photomultiplier tubes with Cherenkov light

The Fluorescence Detector of the Pierre Auger Observatory

Optic Detectors Calibration for Measuring Ultra-High Energy Extensive Air Showers Cherenkov Radiation by 532 nm Laser

Distillation purification and radon assay of liquid xenon

Hands on Project: Large Photocathode PMT Characterization

A NEW GENERATION OF GAMMA-RAY TELESCOPE

Calibration of large water-cherenkov Detector at the Sierra Negra site of LAGO

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

First Results from the Pierre Auger Project

arxiv: v2 [physics.ins-det] 17 Jun 2014

Publications of Francesco Arneodo: journal articles

Extensive Air Showers and Particle Physics Todor Stanev Bartol Research Institute Dept Physics and Astronomy University of Delaware

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Upper Limit of the Spectrum of Cosmic Rays

Calibration of the Modular Neutron Array (MoNA)

Scintillation Detector

Development of a 3D-Imaging Calorimeter in LaBr 3 for Gamma-Ray Space Astronomy

Extreme high-energy variability of Markarian 421

Observation of Atomic Spectra

Comments on the possible observation of d-d fusion in sonoluminescence (Reference-31 in Taleyarkhan et al. [2002] 1 )

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

Photon Instrumentation. First Mexican Particle Accelerator School Guanajuato Oct 6, 2011

Primary CR Energy Spectrum and Mass Composition by the Data of Tunka-133 Array. by the Tunka-133 Collaboration

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

Supplementary Figure 1 Comparison of single quantum emitters on two type of substrates:

Transcription:

Air Fluorescence Photon Yield In Cosmic Ray Showers Ryan D. Reece REU student advised by Prof. Katsushi Arisaka August 24, 2005 Abstract Several cosmic ray observatories rely on fluorescence in air as a means to detect cosmic rays and measure their energy. An accurate measurement of the conversion of energy from a cosmic ray shower into fluorescence photons is key to this method. In this experiment, air fluorescence photon yield caused by the emission of electrons from a 90 Sr source was measured to be 3.0 ± 1.1 photons/(electron m). Our goal of this measurement is for it to be a prototype for more accurate measurements of fluorescence photon yield as a function of temperature, pressure, and mixture in hope to resolve the AGASA- HiRes problem. 1 Motivation 1.1 Fluorescence Detection and Photon Yield When a high energy cosmic ray collides with the earth s atmosphere, it initiates a shower of secondary particles (see Figure 1), including electrons and positrons, the scattering of which cause the atmosphere to fluoresce. The a senior at The University of Texas Austin Research Experience for Undergrads The University of California Los Angeles, Dept. of Physics and Astronomy 1

Figure 1: Cosmic ray shower composition primary source of atmospheric fluorescence is the excitation of nitrogen molecules. One of the techniques in detecting and studying high energy cosmic rays is observing this fluorescence. In order to measure the energy of the primary cosmic ray, the fluorescence detection method relies on the atmosphere as a calorimeter. Fluorescent light is detected by a by an apparatus of photomultiplier tubes (PMT) on clear, dark nights. The accuracy of this method depends heavily on the relationship between the path length of a given energy particle in the atmosphere and the amount of fluorescence it initiates. Fluorescence photon yield or just fluorescence yield is the number of photons fluoresced per unit length that a given energy electron penetrates through air. 1.2 Previous Fluorescence Yield Measurements The first measurement of fluorescence photon yield was done by Alan Bunner[3] for his PhD thesis. He combined existing kinetic theory to predict the effect of pressure and therefore altitude dependence. His work had considerable error but remained the standard for many years for interpreting fluorescence 2

Figure 2: Fluorescence detection of cosmic ray showers cosmic ray data. More recently Kakimoto et al.[4] did a study of the pressure dependence of fluorescence yield. Another study by Nagano et al.[5] in agreement with Kakimoto gives the currently accepted value of fluorescence yield at standard temperature and pressure to be 3.7±0.148 photons/(electron m) with 13.2% systematic error. 1.3 The AGASA-HiRes Problem The Akeno Giant Air Shower Array (AGASA), a ground array cosmic ray detector, and the High Resolution Fly s Eye fluorescence detector (HiRes) give disagreeing energy spectra[1] (see Figure 3). The energies in the HiRes spectrum are approximately 30% less than those of AGASA. While it is possible that AGASA s computer based reconstruction may not be precise enough, inaccuracy in the measurement of fluorescence photon yield could show HiRes s spectrum to be too low. If the accepted value of fluorescence yield is too high, then flourescence detectors like HiRes would predcit that the number of scattered particles in a cosmic ray shower is actually lower than it is in reality, underestimating the energy of the primary cosmic ray. The Pierre Auger Project[2] is a hybrid detector, using both ground array and fluorescence detection methods and is more sensitive than either AGASA or HiRes before it. This makes an accurate measurement of fluorescence photon yield even more necessary. 3

Figure 3: AGASA vs HiRes. Note that HiRes spectra are lower than AGASA s. Inaccurate knowledge of the value fluorescence yield in air could explain this discrepancy. 2 The Experiment 2.1 Theory As defined in section 1.1, fluorescence photon yield (Y ) can be expressed as: Y N γ N e L (1) where N γ is the number of photons emitted by N e number of electrons passing through a line of air of length L. If one uses a photomultiplier tube (PMT) to observe this fluorescence, then the number of fluorescence photons that actually produce a signal (N sig ) is attenuated by several factors: the fractional solid angle 1 in view of the PMT (Ω, see Figure 4), the transmission of the any filter used (f), the PMT s quantum efficiency (QE) and collection efficiency (CE), and L is now the length of electron beam in view of the PMT. N sig = N γ Ω f QE CE (2) 1 Ω = Ω solid angle 4π 4

Figure 4: Fractional solid angle (Ω) Assuming reasonable values 2 for Ω, f, QE, CE, L, and relying the [5] measurement by Nagano et al.[5] of Y as an order of magnitude estimate, the number of fluorescence events that we could expect to detect (N sig /N e ) was of the order of 10 4. 2.2 Setup and Procedure We used a 1 mci 90 Sr sample as a source of energetic 3 electrons. The 90 Sr source was placed down in a small hole drilled part way into a solid plastic cube. This collimated the emission of electrons into a vertical beam. The electron beam passed through a pair of plastic scintillators connected to PMTs, used for triggering events. The first PMT was a Hamamatsu E2624- C1 with a plastic scintillator of thickness 3 mm. The second was a Hamamatsu H1161 and had a scintillator of thickness 2 cm. A third Hamamatsu H3178 PMT (referred to as the FD PMT ) observed the region between the two trigger PMTs for fluorescence. Because single photon counting sensitivity was necessary for this measurement, several methods were used to protect the fidelity of the FD PMT s signal. The apparatus shown in Figure 5 was entirely enclosed in a dark box. Both scintillators were covered to prevent light from being seen by the FD PMT. A wide pass UV filter (see appendix B for the spectrum) was chosen for its high transmission in the range of the nitrogen fluorescence spectrum 2 Round the numbers in table 1 for some reasonable values. 3 Nagano et al.[5] measured the mean energy of electrons emitted by 90 Sr to be 0.85 MeV. 5

Figure 5: Experiment setup (see appendix A). This filter helped to eliminate contamination of the signal by visible light from imperfections in the dark box. Lead bricks surrounding the the FD PMT suppressed contamination by bremsstrahlung radiation that may have been created by the electron beam scattering in the collimator or elsewhere. We took data from the FD PMT through an LeCroy 2249W Analog to Digital Converter (ADC) using the coincidence of the two trigger PMTs as a gate with a width of 40 ns and histogramed the events. The correct timing was found by inserting an uncovered scintillator into the electron beam in view of the FD PMT, artificially making a signal 4. Limiting our data to the coincidence of the trigger PMTs in a narrow gate further aided in suppressing non-fluorescence signal events. Because the vast majority of events were events with no signal, our histogram contained a large peak of counts referred to as the pedestal. An amplifier for the FD PMT signal was necessary to pull the single photon fluorescence events significantly away from the pedestal so that they could be counted. A foam block was cut to fit tightly between the lead bricks and the side facing the FD PMT was covered with thick black paper. Nothing else about the experimental setup was modified and data was taken. This data was used to give a background signal that may be caused by the thermal emission of electrons in the PMT, radioactive contaminates, or the instability of the electronic equipment. 4 We found it reasonable to assume that the time scale for scintillation in a plastic scintillator is comparable to that of fluorescence in air. 6

Figure 6: Data acquisition setup 3 Analysis 3.1 Data Approximately 6 million events were recorded for both the signal and the background. This was necessary in order to collect a significant number of fluorescence events because of the many attinuation factors shown in equation 2. The two sets of data are normalized and plotted in Figure 7. Knowing the gain of the PMT, we expected a single photon signal to peak around channel 135 as it does. The low occurrence of background events in the region of the fluorescence events verifies our signal s fidelity. Subtracting the background from the signal gives a fairly clean single photon distribution as our fluorescence events (see Figure 8). Making a cut on this distribution, the counts between channels 80 and 180 were summed to give N sig. The number of triggered events (N trig ) selected the number of beamed electrons that were observed (see Figure 8). Therefore: N trig = N e (3) Combining equations 1, 2, and 3 gives our equation for calculating the fluorescence photon yield: Y = N sig N trig Ω f QE CE L (4) 7

Figure 7: Fluorescence data, signal: red, background: blue Figure 8: Signal minus background, fluorescence events. N sig was recorded as the counts between channels 80 and 180. 8

Table 1: Data and error Quantity Magnitude Error (%) N sig 2.6 10 3 photons 10 N trig 5.9 10 6 electrons 0 Ω 9.7 10 3 10 f 0.89 5 QE 0.25 30 CE 0.85 10 L 10 cm 5 Y 3.0 photons/(electron m) 35 3.2 Error The measured value and estimated error 5 for each quantity is displayed in table 1. Addition of errors in quadrature gives the error on the fluorescence photon yield to be approximately 35%. 4 Conclusion 4.1 Results We measured the fluorescence photon yield of air excited by electrons from a 90 Sr source to be 3.0 ± 1.1 photons/(electron m). As a prototype for future measurements, this experiment has been a success. The fact that this number can be produced, within range of previous measurements, by such a rough study demonstrates that a precise measurement of this number is achievable. Compare our measurement of fluorescence yield with the 3.7 photons/(electron m) by Negano et al. If fluorescence yield actually is smaller than his value, this could explain the AGASA-HiRes discrepancy by shifting the HiRes spectrum up into agreement with AGASA. Further investigation into accurately measuring fluorescence photon yield is necessary in order to properly interpret data from cosmic rays detected by fluorescence. Not only could a reliable measurement of this value resolve the AGASA- 5 A possible error not included in this analysis is that Raleigh scattered Cherenkov light created by the electron beam might contaminate the signal, but this effect was not considered. 9

HiRes problem, it would improve the proper calibration of the Pierre Auger Project[2]. 4.2 Recommendations for Future Experiments An experiment measuring the temperature, pressure, and mixture dependencies of fluorescence photon yield is warranted. Putting an apparatus similar to the one Figure 5 in a vacuum chamber would not only make it light-tight, but allow the ability to test variable mixtures of N 2, O 2, and CO 2 at different temperatures and pressures. This procedure could be used to simulate cosmic ray fluorescence at different altitudes. New electronics, especially a clean amplifier and a quality PMT of highgain, would give confidence that no irregularities could affect the data acquisition. A way of automatically alternating taking signal and background data by means of an automatic shutter would help reduce any miscomparison of the data because of instability in the pedestal. A more sophisticated method of subtracting the background from the signal either by weighting the significance or doing some kind of curve fitting may give a more reliable result. Quantum and collection efficiency of the FD PMT should be precisely measured. This alone, could greatly reduce the error in our measurement. Finally, a future measurement should be capable of collecting many events. Taking events of the order of 10 7 or more would mean that several thousand fluorescence events could be observed. 5 Acknowledgments I would like to thank Professor Arisaka for assigning me such a challenging and important measurement, for his guidance, and for his perspective. Thank you Arun Tripathi, David Barnhill, Joong Lee, Matt Healy, and Antoine Calvez for your assistance in this measurement. I am especially grateful to Tohru Ohnuki for his initiative, long hours, and invaluable advice. Thank you Francoise Queval for coordinating the UCLA physics REU program, and thank you NSF for funding my time and research. 10

References [1] Knurenko, S. P. et al. Spectrum of Cosmic Rays with Energy above 10 17 ev. arxiv:astro-ph/0411484v1. 17 Nov 2004. [2] Clay, Roger, and Bruce Dawson. Cosmic Bullets. Reading: Addison- Wesley, 1998. [3] Bunner, Allan N. Cosmic Ray Detection by Atmospheric Fluorescence. PhD Thesis. Cornell University. (1967). [4] Kakimoto, F. et al. A Measurement of Air Fluorescence Yield. Nucl. Instrum. Methods Phys. Res. A372 (1996) 527-533. [5] Nagano, M. et al. Photon Yields from Nitrogen Gas and Dry Air Excited by Electrons. arxiv:astro-ph/0303193v1. 10 Mar 2003. 11

A Nitrogen Spectrum Figure 9: Nitrogen spectrum. Principal wavelengths of emission are between 300 and 400 nm. 12

B UV Pass Filter Figure 10: Hoya U-330 filter from Edmund Industrial Optics. Transmits the principal wavelengths of the nitrogen spectrum. 13

C Gain Plot Figure 11: Trig PMT 1 in this experiments setup is PMT C on this plot. Trig PMT 2 is A and the FD PMT is D. 14

D ENF Plot Figure 12: Trig PMT 1 in this experiments setup is PMT C on this plot. Trig PMT 2 is A and the FD PMT is D. 15