Manual Dew point scanner PCE-DPT 1

Similar documents
Instruction Manual SEFRAM Thermal Camera

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

InfraRed Thermometer with Laser Pointer

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

INFRARED THERMOMETER TM0819

Manual Rotational viscometer PCE-RVI 2

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

566/568. Infrared Thermometers. Getting Started

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

Sitting height... 6 Back tilt and back height... 6 Armrest... 7 Brakes... 7 Charging VELA Tango 300E... 7

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

INFRARED THERMOMETER Model : TM-959

Infrared Thermometer Model CA879

Operating Manual 1.1-4x24 Zenith x24 Zenith

TG646 WEATHER STATION

INSTRUCTION MANUAL Fax: (503)

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Introduction Cautions

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Power Resistor for Mounting onto a Heatsink Thick Film Technology

VELA Tango 100. VELA Tango 100A. VELA Tango 200 GAS

Power Resistor for Mounting onto a Heatsink Thick Film Technology

Eppendorf SmartBlock. Instructions for use

TM360 TEMP-SEEKER PRECISION THERMO-PSYCHROMETER OPERATION MANUAL

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

The Fluke 66 and 68 Infrared Thermometers

Dual laser + type K thermometer INFRARED THERMOMETER

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

Operator's Manual. optris BR 400. Calibration source

ea980r Digital Anemometer User Manual

DIGITAL THERMOMETER OPERATOR S MANUAL

u s e r m a n u a l w w w. v e l a. E U

Power Resistor for Mounting onto a Heatsink Thick Film Technology

Today s Weather 24 Hour Forecaster

Mini Environmental Quality Meter

Requirements to perform accurate dielectric material analysis

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

6.Ebz!boe!8.Ebz!!! Gpsfdbtufst!!! G U I D E n catio Lo

INSTRUCTION MANUAL RS 51 & RS 52 DIGITAL THERMOMETER

symphony Reference Electrodes

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

Infrared Thermometer Model: and

Subminiature Transmissive Optical Sensor with Phototransistor Output, RoHS Compliant, Released for Lead (Pb)-free Solder Process

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

N) manual. Biomaster Operating manual

MODEL HMP45C TEMPERATURE AND RELATIVE HUMIDITY PROBE INSTRUCTION MANUAL

Power Resistor for Mounting onto a Heatsink Thick Film Technology

INSTRUCTION MANUAL DTH Fax: (503)

Anemometer Thermometer Hygrometer

(PT-A6) Visible Light Detector for Security Lighting

Minimum (-31) every 10 s -35 (-31)

(PT-A6) Visible Light Detector for Security Lighting

473-SHX Dew Point Mirror

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Platinum SMD Flat Chip Temperature Sensor

Type B xxx/60. Snowplough // USER MANUAL Version 1.0 EN. Art.Nr.:

WS-7211U Wireless 433 MHz Weather Station. Instruction Manual

The Fundamentals of Moisture Calibration

WT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual

3B SCIENTIFIC PHYSICS

Device Specifications

Low Differential Pressure Gage

Lufft MARWIS-UMB Mobil Advanced Road Weather Information Sensor

473 Dew Point Hygrometer

IMPORTANT. Questions? Contact Customer Support at (877) or visit Display for 5-in-1 Weather Sensor model 06016RM

KTC LED.PowerSpot 6W LED

Silicon NPN Phototransistor with V λ Characteristics Version 1.3 SFH 3410R

Humidity Calibration Solutions

IR/Thermistor Pen. Instruction Manual

5-25x56 PMII PSR Illuminated with Double Turn

SPECIFICATION SHEET : FHS2-UNV-36L

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL

IS2805 DESCRIPTION FEATURES

TOL-CFcPGKC. Lamp LED. Features. Dimensions. Chip Lens Color. Part Number. TOL-CFcPGKC AlGaInP Pure Green Water clear

473 Dew Point Hygrometer

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

Power Resistors for Mounting Onto a Heatsink Thick Film Technology

Gebrauchsanleitung. Operating instructions. Gebruiksaanwijzing. Mode d'emploi. Istruzione d'uso. Instrucciones de manejo

Operating Manual. Turb 355 IR/T. Portable turbidimeter. ba75454e03 09/

50 W Power Resistor, Thick Film Technology, TO-220

Surface Mount Multilayer Ceramic Chip Capacitors for Safety Certified Applications

HI Propylene Glycol Refractometer INSTRUCTION MANUAL

Small Signal Zener Diodes, Dual

Dewpoint Meter Data Sheet / Instructions

Field Pro Operation and Installation Manual

5-25x56 PMII PSR With Double Turn

Surface Mount Multilayer Ceramic Chip Capacitors DSCC Qualified Type 05007

PRODUCT SAFETY SUMMARY (GPS) SODIUM-HYDROXIDE

QUANTUM CONCEPT. Swimming User s Manual

symphony Multisensor Probes

Lufft MARWIS-UMB Mobile Advanced Road Weather Information Sensor

Data Sheet / Instructions. Dewpoint MeterO

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

Instruction Manual HI Refractometer for Sodium Chloride Measurements

Transcription:

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA Tel: 410-387-7703 Fax: 410-387-7714 info@pce-americas.com www.pce-instruments.com/us www.industrial-needs.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign way Southampton Hampshire United Kingdom, SO31 4RF Tel: 02380 98703 0 Fax: 02380 98703 9 info@industrial-needs.com www.pce-instruments.com/english Manual Dew point scanner PCE-DPT 1

Version 1.0 Date of creation: 11/12/2014 Date of last change: 30.12.2014 Table of contents 1 Introduction... 3 2 Safety information... 3 3 Specifications... 4 4 Device description... 4 5 Instructions... 5 6 Maintenance... 6 7 Disposal... 6 8 Contact... 7 8.1 PCE Instruments UK... 7 8.2 PCE Americas... 7 2

1 Introduction Thank you for purchasing a PCE-DPT 1 dew point scanner from PCE Instruments. This device can be used anywhere where there is a certain risk of mould formation. This device is basically an infrared thermometer with an integrated humidity meter. The two sensors measure the parameters relevant for the determination of dew points. If the dew point is reached or fallen below, mould formation can occur. When the dew point sensor starts, the room temperature and atmospheric humidity can be measured. The dew point then serves as a reference for infrared measurements at places with a high risk of mould. The energy saving detector then indicates the places with poor insulation possibly causing damp stains and possible mould formation. Delivery content: 1 x dew point scanner PCE-DPT 1, 1 x case, 1 x 9 V block battery 1 x manual 2 Safety information Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no warranty of damages or injuries caused by non-observance of the manual. - The device may only be used in approved temperature and humidity ranges as stated in the specifications. Extreme temperatures, direct exposure to sunlight, extreme atmospheric humidity or moisture (e. g. wet hands) must be avoided. - The case must only be opened by qualified personnel of PCE Instruments. - The instrument should never be placed with the user interface facing an object (e.g. keyboard side on a table). - You should not make any technical changes to the device. - The appliance should only be cleaned with a damp cloth / use only ph-neutral cleaner, no abrasives or solvents. - Only use the device along with PCE accessories or equivalent. - The appliance must not be used in potentially explosive atmospheres. - Before any measurement, check the device by measuring a known factor. - The measurand set points laid down in the specifications may under no circumstances be exceeded. - Never target at people / people s eyes. - The laser pointer must not be targeted in the direction of explosive gases. - Always check whether the correct measurement range has been set before you start the measurement. - The device is for indoor use. This manual is published by PCE Instruments without any guarantee. We expressly refer to our general guarantee terms, they can be found in our general terms of business. If you have any questions please contact PCE Instruments. 3

3 Specifications Temperature range -50... 350 C / -58... 662 F Resolution 0.1 Emissivity fixed at 0.95 Temperature accuracy ±3.5 C @ -50... 20 C / -58... 32 F 1% ±1.5 C @ 20... 350 C / 32... 662 F 8 14 μm 0 100 % RH Wavelength range Humidity range Humidity accuracy ±3.5 % (20 %... 80 %) Dew point temperature (-30... 100) C / (-22... 212) F D:S 12:1 4 Device description (1) Function trigger (2) Key for backlight / laser (3) MODE key (4) C / F key 4

5 Instructions DP = dew point The dew point or dew point temperature is defined as the temperature at which condensing and evaporating water on an object (when there is humidity) are at equilibrium or, in other words, at which condensation starts. AT = ambient temperature The device measures the ambient temperature in your environment and indicates it on the display. After you switch on the device, ambient temperature, humidity and dew point temperature are measured and indicated on the display. Press the MODE key to switch between temperature, humidity and dew point temperature. Target at the spot you wish to measure. Remove the detector slowly to determine the temperature of the object to be measured. If the measured temperature is between the ambient temperature and the dew point temperature, the meter will show the simulated D value with the ambient temperature. The meter can detect mould if the measured temperature value is in the first third of the range between ambient temperature and dew point temperature. The green LED indicates that temperature and humidity are within the normal range. If the measured temperature value is in the second third of the range between ambient temperature and dew point temperature, the yellow LED indicates that mould may form at this spot. If the measured temperature value is above the second third of the range between ambient temperature and dew point temperature, the red LED indicates that mould has already formed at this spot. 5

For example: When the device has just been switched on, the measured ambient temperature is 25 C, relative humidity is 50 % and the dew point temperature is 13.8 C green LED measured temperature is between 25 C -21.2 C yellow LED measured temperature is between 21.3 C -17.4 C red LED measured temperature is between 25 C -13.8 C 6 Maintenance Battery replacement: When the battery symbol flashes on the display, you should replace the battery. To do so, open the battery compartment cover and replace the battery by a new 9 V battery. 7 Disposal For the disposal of batteries, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law. If you have any questions, please contact PCE Instruments. All products are CE and RoHs approved. 6

8 Contact If you have any questions about our range of products or measuring instruments please contact PCE Instruments. 8.1 PCE Instruments UK By post: PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign Way, Southampton Hampshire United Kingdom, SO31 4RF By phone: Support: 02380 987 035 Sales: 02380 987 030 8.2 PCE Americas By post: PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter 33458 FL USA By phone: Phone: 410-387-7703 Fax: 410-387-7714 You can find an overview of our measuring instruments here: http://www.industrial-needs.com/measuring-instruments.htm You can find an overview of our scales here http://www.industrial-needs.com/balances.htm 7