Probabilistic Approach for Material Verification and Identification in Pharmaceutical Applications

Similar documents
Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy

for XPS surface analysis

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Fast, Effective XPS Point Analysis of Metal Components

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

IN QUALITATIVE ANALYSIS,

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Complete Materials Deformulation Using TGA-IR

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

MetWorks Metabolite Identification Software

of mass spectrometry

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Keysight Technologies Instrumented Indentation Testing with the Keysight Nano Indenter G200. Application Note

Global 3D Machine Vision Market Report- Forecast till 2022

High-Field Orbitrap Creating new possibilities

HILIC Method Development in a Few Simple Steps

Augmented Reality Market Research Report- Global Forecast till 2023

Verification of Pharmaceutical Raw Materials Using the Spectrum Two N FT-NIR Spectrometer

Automated and accurate component detection using reference mass spectra

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS

Determination of Carbon d13c isotopic composition from DIC samples

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

The Institute Laue Langevin (ILL) and its pioneering user system

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Pros and cons of using correlation versus multivariate algorithms for material identification via handheld spectroscopy

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Performance and Control of the Agilent Nano Indenter DCM

Inspection of raw materials and chemicals by using Raman Spectroscopy October, 2013

Keysight Technologies Young s Modulus of Dielectric Low-k Materials. Application Note

AN2970 Application note

Application Note 12: Fully Automated Compound Screening and Verification Using Spinsolve and MestReNova

MiSeq System. Denature and Dilute Libraries Guide

The Fundamentals of Moisture Calibration

High-Resolution Accurate-Mass (HRAM) Phthalate Screening using Direct Analysis in Real Time (DART) Ambient Ionization

Export Destinations and Input Prices. Appendix A

Microbial DNA qpcr Multi-Assay Kit Clostridium perfringens Pathogenicity

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

Keysight Technologies Measuring Substrate-Independent Young s Modulus of Low-k Films by Instrumented Indentation. Application Note

IDRaman reader and IDRaman mini: Raster Orbital Scanning (ROS)

Quantitation and Characterization of Copper Plating Bath Additives by Liquid Chromatography with Charged Aerosol Detection

The shortest path to chemistry data and literature

Monitoring Protein PEGylation with Ion Exchange Chromatography

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Keysight Technologies Measurement Uncertainty of VNA Based TDR/TDT Measurement. Application Note

Confirmation of Coal Quality Using the Agilent ExoScan 4100 Handheld FTIR Spectrometer

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm

Thermo Scientific GasBench II

Overcoming Interferences with the Thermo Scientific icap 7000 Plus Series ICP-OES

Enhancement of Linearity and Response in Charged Aerosol Detection

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Whole Tablet Measurements Using the Frontier Tablet Autosampler System

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

Targeted protein quantification

Semi-Targeted Screening of Pharmaceutically- Related Contaminants in the Thames Tideway using LC-HRMS

Thermo Scientific HyperSep Dispersive SPE Products. Efficient sample preparation and clean-up using the QuEChERS Method

Optimization of temperature-sensitive assays using the Spark Te-Cool

Method Transfer across Multiple MicroNIR Spectrometers for Raw Material Identification

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Estapor Microspheres n 11. A technical newsletter published by Merck Chimie SAS - France

Spectrophotometric quantification of nucleic acids using the nanovette microliter cell accessory with a DU 730 spectrophotometer

δ 13 C of DIC and carbonate samples: comparison of traditional mass spectrometry methods with an infrared spectrometry method

2017 Scientific Ocean Drilling Bibliographic Database Report

Transcription:

Probabilistic Approach for Material Verification and Identification in Pharmaceutical Applications Fundamentals and Performance Characterization of Thermo Scientific TruScan Analyzers White Paper Key Words Raman spectroscopy, pharmaceutical inspections, material identification, Thermo Scientific TruScan analyzers, method development, statistical analysis Executive Summary Spectroscopic material verification is a critically important analytical application within the pharmaceutical industry because of the adoption of standards such as the Pharmaceutical Inspection Co-operation Scheme (PIC/S), Annex 8. PIC/S Annex 8 requires that individual samples be taken from all incoming containers and an identity test be performed on each sample. This is a major change from the traditional practice of allowing composite sampling of a statistical subset of the batch and identity testing of the single composited sample, in order to release the batch to manufacturing. Individual container identity testing puts drastically higher demands on expert analysts time. TruScan s revolutionary capabilities enable nonexperts, such as receiving personnel at the loading dock, to positively verify the identity of materials at the point of receipt, increasing an organization s throughput and cycle time. TruScan is the first device of its kind to employ embedded uncertainty tracking and estimation. Tracking the uncertainty enables the onboard analytics to determine if the material is consistent with a particular reference -- without forcing the end-user to perform time-consuming calibrations or call on expert, manual interpretation. Thermo Scientific TM TruScan RM TM and TurScan GP TM spectroscopic analyzers Probabilistic Approach Verification of a material s chemical identity involves instrument hardware to measure the optical properties of the sample and, if expert oversight is to be avoided, embedded statistical analysis to determine if the material is consistent with a particular reference or references. Rapid advancements in optical components used for Raman spectroscopy have dramatically improved instrumentation hardware, with regard to ruggedness and portability. Thermo Scientific s TruScan platforms are expressly designed for setup and use by non-experts. In most direct terms, TruScan not only acquires the Raman spectrum of the material of interest but also in real-time determines the uncertainty of that measurement, given factors such as

2 the sample characteristics, instrument telemetry, environment and testing environment. By uncertainty we mean how repeatable and reliable we expect that measured spectrum to be over similar or even different sampling conditions. In statistical terms, uncertainty refers to standard deviation. TruScan poses and answers the following question: Is the measurement of the test material statistically consistent with the measurement of the reference material? - For the TruScan RM analyzer - The answer is yes (Pass) if no significant difference between test and reference measurements was observed (p-value >= 0.05), and no (Fail) otherwise. See Figure 1. - For the TruScan GP analyzer - The answer is yes (Positive Match) if no significant difference between test and any reference measurements was observed (p-value >= 0.05), and no (No Match Found) otherwise. See Figure 2. Figure 1. TruScan RM Authenification Result Output Figure 2: TruScan GP Identification Result Output For illustration purposes, the two figures below graphically depict the pass/fail (Figure 3) and positive match/no match criteria (Figure 4) on a univariate t-distribution. The difference between the measured and reference spectra is the basis of the x-axis in the illustration. Figure 3: TruScan RM pass/fail univariate t-distribution Figure 4: TruScan GP Positive Match/No Match univariate t-distribution

3 If the difference falls within the limits corresponding to a p-value of 0.05 (the green shaded area) the sample measurement is considered consistent with the reference spectrum, within the uncertainty of the measurement, and the device will report Pass or Positive Match. If the difference falls outside the limits (red shaded area), the device will report Fail or No Match. This device employs a 785 nm +/- 0.5 nm laser (excitation wavelength) with a 2 cm -1 line width and stability of < 0.1 cm -1, resulting in a Raman shift range from 250 to 2875 cm -1 and spectral resolution of 8 to 10.5 cm -1 (FWHM). These specifications result in approximately 2000-dimensional spectral data, with the p-value test conducted in all dimensions simultaneously. Therefore, Figures 3 and 4 above are extreme but representative simplifications. The probability curve is developed by the software during method development and its shape is a function of easily modeled sources of uncertainty. Since the software models the uncertainty directly, there is no calibration or user-modeling involved with method development. A single reference spectrum typically suffices for method development with bulk materials because the physical properties of the sample (e.g., particle size, packing density, humidity/ water) have minimal influence on the Raman spectra TruScan acquires, and the remaining sources of variability are modeled directly by the embedded analysis. If more than one reference spectrum is used for a TruScan RM method, the question above is repeated for each reference spectrum, and if the outcome of any comparison is a Pass, then the method as a whole will pass. That is, the measurement of the material was consistent with at least one of the measurements of the reference materials. The analysis does not average the reference spectra together and perform a test of equivalence using the average spectrum. In the TruScan GP, if the sample measurement is consistent (p-value >= 0.05) with more than a single reference spectrum in the library, all matches are reported in rank order of p-value. Decisions and Outcomes End users of field-material identification systems are not usually spectroscopy experts and, therefore, rely on an algorithm to convert instrument data to a qualitative result. Like all data-driven judgments, this qualitative result is invariably right or wrong. For spectroscopic material identification, the outcome tree (Figure 5) is slightly more complex than simply right and wrong. Therefore, the critical question for the end user is If my instrument fails to report a Pass or Positive Match, how often am I correct in identifying the unknown, and how often am I mistaken? Figure 5: Outcome tree for decision making based on a qualitative result.

4 Performance Characterization Receiver Operator Characteristic (ROC) curves 1-3 have long been used to depict the tradeoff between sensitivity of detection and false-positive rates for qualitative tests. While they are easily understood graphics of test capability, ROC curves are insufficient for the material identification task in at least one sense: spectroscopic material identification systems could return multiple material records in response to a single measurement query. Qualitative precision is, therefore, an additional performance characteristic that is important from an end-use perspective. The effectiveness of information retrieval systems are more typically characterized by precisionrecall (PR) curves. 4 McLafferty et al. employed PR curves 5 in their evaluation of mass spectral library search software. However, their objective was substructure identification rather than full molecular identification. The PR curve also does not reflect false-positive rates because in document retrieval it is assumed that there are always relevant records in the database. This is an inappropriate assumption for spectroscopic material identification because the systems will invariably encounter materials that are not in the device s library of materials. Therefore, it is necessary to construct new parameters for a spectroscopic material identification system, which can be characterized by the following: true-positive rate @ t : if materials in the system library are tested under field conditions, how likely is the system to declare a match of an unknown to the correct library materials? false-positive rate @ t: if materials that are not in the system library are tested under field conditions, how likely is the system to declare false matches of an unknown to other irrelevant materials in the system library? To examine the system s operating characteristics, we also have to assume that the spectroscopic material identification device has a tunable parameter (denoted t in the definitions above and is the p-value threshold value in the ROC study), which would allow it to be more liberal or conservative in suggesting a material identification. Experiment We examined the performance of Thermo Scientific s handheld Raman verification system, as performance verification of the system is critical. A multi-device, multi-user experiment was designed and executed over 8 weeks, with materials chosen at random by serial number. This involved: 6 devices 335 measurements in vial-holder 6 operators 455 measurements in free space 261 unique chemical materials 376 liquid measurements 790 total measurements 414 solid measurements Five of the users were characterized as having light experience with the device (equivalent to two days of training) and one user was a novice, having approximately five to ten minutes of operational training at the start of the study. Of the 790 measurements, 664 were made on materials represented in the system library. For a more rigorous assessment of false-positive rates, the results of these tests were also re-analyzed by removing the relevant library record and re-examining test results for any false-positives that would have occurred. The devices executed the embedded version of Thermo Scientific s probabilistic material verification software in real time, and were operating in auto-measure mode, in which the device governs all tunable software parameters on a measurement-by-measurement basis.

5 Results of the Experiment The aggregate ROC curve 6 for all six devices is shown in Figure 6. The experimental uncertainty (95th percentile) in the point estimates is indicated by the blue shaded area while the measured curve itself is in red. The area under this ROC curve, a bulk measure of qualitative accuracy, is 96.9% with an uncertainty of 1.0% (95th percentile). The results were very consistent across the 6 devices/users participating in the study. Figure 6: Aggregate ROC curve for all devices in the experiment Recall that the ROC curve does not convey precision information. Tabulation of the precision characteristics in the experiment is shown below. # of Possible Materials Identified % of cases interval estimate 0 92.7% [89.7% 94.9%] 1 5.2% [3.4% 7.8%] 2 1.1% [0.5% 2.7] 3 0.6% [0.2% 2.0%] 4 0.4% [0% 1.6%] In 93 percent of all test cases, the system reported only the correct material as a plausible match. In 99.4 percent of all test cases, the system reported the correct material as the first (e.g. most likely) or only choice. Summary Analytical devices employed in the pharmaceutical environment require performance characterization. In applications for material verification and identification, strict rules must be defined for robust, repeatable operation of these devices by non-expert users. Traditional analytical methods of measuring qualitative performance (SNR, SEL, SEN, LOD) are unsuitable for characterizing identification of unknowns. ROC curves and precision characteristics represent a promising means to measure spectroscopic discovery library performance. When rigorously tested in an end-use situation, the Thermo Scientific handheld Raman devices accurately and precisely identify the correct or most likely material being analyzed. These spectroscopic material identification tools have been employed by non-expert field users and are found acceptable for pharmaceutical validation requirements. In all, TruScan uses very advanced processing during both data collection and analysis to ensure that sound statistical judgment supports every material-verification decision. It is the first device of its kind to employ embedded uncertainty tracking and estimation, rather than forcing the end-user to calibrate. This translates to very rapid method development, and extremely high objective selectivity in a device in the hands of the non-expert.

References 1. JA Swets et al., Assessment of diagnostic technologies Science 205:753-759 (1979) 2. TD Wickens, Elementary Signal Detection Theory, Oxford University Press 2001 3. CD Brown, and HT Davis, Receiver operating characteristic curves and related decision theory measures: a tutorial, Chemometrics and Intelligent Laboratory Systems 80:24-38 (2006) 4. D Lewis, Representation quality in text classification: an introduction and experiment, Proceedings of the Workshop on Speech and Natural Language, Morgan Kaufmann 1990; pp. 312-318 5. GM Pesyna et al. Probability based matching system using a large collection of reference mass spectra Analytical Chemistry 48:1362-1368 (1976) 6. Proc. of SPIE, spie.org, Vol. 6378 637809,1-11 White Paper i CD Brown and RL Green, Considerations for embedded authentication using intelligent portable Raman systems, FACSS 2006, Orlando, FL ii CD Brown, Revisiting the Assumptions of Spectral Library Search in Light of New Frontiers, FACSS 2005, Quebec, PQ iii J Li, DB Hibbert, S Fuller, G Vaughn, A comparative study of point-to-point algorithms for matching spectra, Chemom.Intell. Lab. Syst. 82:50 (2006) iv BT Bowie, DB Chase, PR Griffiths, Factors affecting the performance of bench-top Raman spectrometers. Part I:Instrumental Effects, Appl. Spectrosc., 54:164A (2000) v BT Bowie, DB Chase, PR Griffiths, Factors affecting the performance of bench-top Raman spectrometers. Part II: SampleEffects Appl. Spectrosc., 54:200A (2000) vi RL McCreery, Raman Spectroscopy for Chemical Analysis, Wiley (2000) vii DL Massart et al., Handbook of Chemometrics and Qualimetrics: Part A, Elsevier (1997) thermoscientific.com 2014 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Africa-Other +27 11 570 1840 Australia +61 2 8844 9500 Austria +43 1 333 50 34 0 Belgium +32 53 73 42 41 Canada +1 800 530 8447 China +86 10 8419 3588 Denmark +45 70 23 62 60 Europe-Other +43 1 333 50 34 0 Finland /Norway/Sweden +46 8 556 468 00 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9434 Italy +39 02 950 591 Japan +81 45 453 9100 Latin America +1 608 276 5659 Middle East +43 1 333 50 34 0 Netherlands +31 76 579 55 55 South Africa +27 11 570 1840 Spain +34 914 845 965 Switzerland +41 61 716 77 00 UK +44 1442 233555 USA +1 800 532 4752