Chilled Mirror Hygrometry

Similar documents
The Fundamentals of Moisture Calibration

Humidity Calibration Solutions

MICHELL TECHNOLOGIES FOR MOISTURE. Calibration. General Principles & Theory, Equipment Considerations

Humidity Calibration Solutions

CALIBRATION. Calibration. General Principles & Theory, Equipment Considerations. Copyright Caltech 2014

Overview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen

473 Dew Point Hygrometer

473-SHX Dew Point Mirror

Edgetech Instruments Inc.

473 Dew Point Hygrometer

Understanding uncertainties associated with the 5128A RHapid-Cal Humidity Generator

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

Multi-element process analyzer

Understanding the uncertainties associated with using the 5128A RHapid Cal portable humidity generator

REALIZATION OF HUMIDITY STANDARD FACILITY USING TWO-PRESSURE HUMIDITY GENERATOR AND HUMIDITY CHAMBER

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Techniques for Fast Measurements of Low Dewpoint in Portable Hygrometers

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Mercury Stack Monitor SM-4

Introduction to Blackbody Sources

Heat stress index. Dewpoint. pressure. altitude

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

CERTIFICATE OF CALIBRATION

Dewpoint Meter Data Sheet / Instructions

Data Sheet / Instructions. Dewpoint MeterO

CALIBRATION CERTIFICATE # 503

Elcometer 116A. Whirling Hygrometer. Operating Instructions

Field IT 50T Series Transmitters

E THERMADATA LOGGER Humidity & temperature recording meter

Mason Technology Ltd

ADI 2040 Process Analyzer

SOPHISTICATED DESIGN, INTUITIVE OPERATION, RESEARCH-GRADE RESULTS

Kestrel 4500 Pocket Weather Tracker

DVS Intrinsic Compact and Economical Dynamic Vapor Sorption System

Complete Moisture Analysis

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

WATER ACTIVITY MEASUREMENT WATER ACTIVITY

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

COPLEY S C I E N T I F I C. A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for:

Response Characteristics of Dew Point Sensor with Aluminum Oxide by means of Correlation between Purging Rate and Tube Length

Fundamentals of Moisture Measurement in Industrial Applications

UV3000. Accurate, precise, and portable ambient gas point analyzer

Quality assurance for sensors at the Deutscher Wetterdienst (DWD)

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

AWOS. Automated Weather Observing Systems COASTAL

Meteorological Instruments for Solar Energy

Measuring Humidity in the Charters of Freedom Encasements Using a Moisture Condensation Method

STATUS OF THE WIGOS DEMONSTRATION PROJECTS

WEATHER STATION FOR SOLAR FARM MONITORING

1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology

DESIGN, CONSTRUCTION AND EVALUATION OF A HUMIDITY GENERATOR

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

Comparison of HCD5000 DewPoint Duo to Condumax II

Mason Technology Ltd

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

LANCOM200 PORTABLE ACID DEWPOINT TEMPERATURE MONITORING. Acid Dewpoint SO3 H2 SO4 QUALITY CUSTOMER SOLUTIONS

3URGXFWLQIRUPDWLRQ 5HVHUYDWLRQRISURSHUW\ULJKWV

Wind Speed & Direction Sensors

CERTIFICATE OF ACCREDITATION

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

792A AC/DC Transfer Standard

Acceleration/Velocity/Displacement VIBRATION METER

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Introduction to Fourier Transform Infrared Spectroscopy

Certificate of Accreditation to ISO/IEC 17025:2005

Metso Concentration Measurement 3300

Automated multi-vapor gravimetric sorption analyzer for advanced research applications

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Lufft MARWIS-UMB Mobil Advanced Road Weather Information Sensor

SERIES 4000 PRECISION DEWPOINT HYGROMETER Integrale INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Solenoid valves Type EVUL

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

792A AC/DC Transfer Standard

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

The calibration of Hygrometer (LectureandTraining )

CERTIFICATE OF CALIBRATION

ITS Sensors. Intelligent Transportation System. The future of mobility and trafic management

Product data sheet Palas U-SMPS 1050 / 1100 / 1200

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Best selling products overview of company AURA a.s.

WEATHER MULTI-SENSOR. Vaisala Weather Transmitter WXT510. Change the Way You Measure Weather

CALIBRATION REPORT FOR THERMOHYDROMETER

Introduction to Fourier Transform Infrared Spectroscopy

Document No: TR 12 Issue No: 1

Spa & Wellness for Pipettes

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Transcription:

Chilled Mirror Hygrometry Precision instruments for critical measurement and control applications

Chilled Mirror Hygrometry Wherever precise, fundamental measurements are required in your laboratory or industrial application, Michell Instruments chilled mirror hygrometers provide the solution. Michell Instruments is an international leader in high-precision sensing with 40 years humidity measurement and calibration experience. In 1980, we designed and provided the Transfer Standard Dew-Point Hygrometer, which formed the first traceability link between NIST (National Institute of Standards and Technology) and European calibration laboratories. We ve been building on this foundation ever since: continually developing and verifying our own chilled mirror reference instruments through continuous usage in our own laboratories and production environment. Our chilled mirror technology is used in-house to consistently and reliably calibrate over 2000 sensors at any moment in time at our calibration centres in UK, Netherlands, France, Italy, USA, Germany and Japan. Michell Chilled Mirror Technology Chilled mirror is the measurement technology of choice for national standards laboratories worldwide. Here s why: Highest attainable accuracy of any dew-point measurement technology Excellent repeatability Wide measurement range Proven, well established and reliable technology Does not suffer from hysteresis Calibration does not drift over time Furthermore, our technology is: Designed with Michell s 40 years expertise in chilled mirror technology built into every instrument Sensitive to minute changes (<5 ppb) in moisture content Designed to withstand harsh industrial applications Accuracy You Can Rely On Moisture is a critical factor in many processes that needs to be monitored and controlled. Chilled mirror hygrometers measure a primary characteristic of moisture the temperature at which condensation forms on a surface. This means that chilled mirror instruments: Have no drift: the temperature at which condensation forms is measured directly, so there are no calculated variables that could shift over time Are inherently repeatable, giving reliable results every time From trace moisture in laboratory environments to hot, saturated gases in heavy industrial processes, Michell s chilled mirror technology provides the most precise, accurate and repeatable measurement of dew point and relative humidity available. Environmental Calibration Aero & Auto Metallurgy Power Gen

Dew / Frost Point Temperature Certificate Number 00000 Date of Issue 04 th January 2012 48 Lancaster Way Business Park Ely, Cambridgeshire CB6 3NW United Kingdom Approved Signatory Mr G. Daines Tel: +44 (0)1353 658000 Fax: +44 (0)1353 658199 e-mail: uk.info@michell.com Website: Page 1 of 2 Customer Sample Customer Customer address Sample Address Customer order number Sample Order Number Received 07 th December 2011 Instrument Michell Dewpoint meter Model Optidew Vision Serial number Instrument 123456 Sensor 123456. Temperature probe 123456 Michell reference number T12345 Measurements performed 19 th to 22 nd December 2011 Laboratory temperature 21 ±2 Laboratory humidity 35 ±10 %rh The hygrometer was calibrated by comparison using reference instruments with UKAS calibration certificates. The Dewpoint sensor was placed in a sensor block through which the sample air passed. The sample At 21, the sensor temperature was controlled, by placing the sensor in a liquid cooled sample was performed in a climatic chamber to within ±0.3 of the nominal value. 0179 The optical surfaces of the hygrometers were cleaned using de-ionised water, prior to the calibration. The output used from the hygrometer was the digital display with a resolution to 0.1. This certificate is issued in accordance with the laboratory accreditation requirements of the United Kingdom Accreditation Service. It provides traceability of measurement to recognised national standards, and to units of measurement realised at the National Physical Laboratory or other recognised national standards laboratories. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. UKAS Accredited Calibration Laboratory 0179 At each Dewpoint, time was allowed to ensure that the calibration conditions had stabilised. This was confirmed while recording the 10 readings (at 2 minute intervals) that are averaged to give the figures recorded in this certificate. No adjustment was made to the hygrometer before the calibration was performed. The measured sample flow rate through the Dewpoint sensor was 1.0 l/m. Generated Test hygrometer Dewpoint Dewpoint Sensor Dewpoint Expanded Temperature Correction Uncertainty -20.37-20.2 21-0.2 ±0.21-5.03-4.9 21-0.1 ±0.19 10.26 10.2 21 +0.1 ±0.18 25.06 25.1 45 0.0 ±0.25 39.98 39.9 45 +0.1 ±0.25 70.10 70.1 75 0.0 ±0.25 Applied Test hygrometer Temperature Temperature Temperature Expanded Correction Uncertainty 10.03 10.0 0.0 ±0.19 25.05 25.0 +0.1 ±0.19 40.07 40.0 +0.1 ±0.19 70.01 70.0 0.0 ±0.18 The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95 %. The uncertainty evaluation has been carried out in accordance with UKAS requirements. The uncertainties quoted in the Certificate of Calibration only apply to the measured value obtained during the period of calibration and are not indicative of the long-term stability of the instrument under test. Chilled Mirror Instruments Chilled Mirror Features Michell s 40 years of expertise in the field of moisture measurement is built into each and every chilled mirror hygrometer design. All of our chilled mirror instruments come with the following features as standard: Measurement Reliability (DCC) DCC Dynamic Contamination Control (DCC) ensures that measurement accuracy and stability are maintained even when contamination is present on the surface of the mirror. During the DCC process the mirror is heated to approximately 20 (36 F) above the sensor temperature to remove the condensation which has formed during measurement. The surface finish of this mirror, with the contamination which remains, is used by the optics as a reference point for further measurements. This removes the effect of contamination on accuracy. Frost Assurance Technology (FAST) 0-5 -10-15 -20-25 -30-35 -40-45 185 Legend Frost Point Dew Point 500 1250 2800 6000 Moisture Content ppm V In carefully controlled laboratory conditions, super-cooled water can exist in temperatures as low as 48 ( 54 F). However, when using a chilled mirror instrument it only occurs on the mirror at temperatures down to around 30 ( 22 F). The difference in vapor pressure between condensed water and ice formed on a chilled mirror can introduce dew-point errors of up to 10% of reading. It is also possible for intermediate states to exist, where the formation is a mixture of ice and super-cooled water, making calculated conversions from one state to the other invalid. All Michell Chilled Mirror Products feature FAST, the frost assurance technology which guarantees all dew-point measurements below 0 (+32 F) are made over ice. The FAST system works by detecting whether the mirror is at a temperature where super cooled water could form, and if so; rapidly cooling the mirror until a film of ice of predetermined thickness forms. Once ice has formed, control returns to the instrument and measurement can begin. Data Communication and Application Software Our chilled mirror instruments feature a digital output (USB, RS232, RS485, ModBus or Ethernet options, depending on model) and multiple analog outputs, allowing configuration and monitoring by a suitable computer, data logger or other device. Adjustable isolated alarm contacts allow the Optidew and S8000 Series to be used for direct process control. Comprehensive application software is supplied with our chilled mirror hygrometers free of charge, to provide an interface to configure and control instrument functions, and enable all measured and calculated parameters to be graphed or logged over time. Supplied with Traceable Calibration CERTIFICATE OF CALIBRATION air was divided to give one path through the reference hygrometer and the other through the test hygrometer. CERTIFICATE OF CALIBRATION Certificate Number 00000 Page 2 of 2 Chilled mirror is free from temperature dependence and remains accurate and drift-free across the entire measurement range. All of our chilled mirror instruments are delivered with calibrations performed against test equipment traceable to NPL and NIST national standards through Michell s ISO/IEC 17025 UKAS accreditation. block, and circulating fluid through it. The fluid temperature is controlled by a re-circulating bath to within ±1.0 of the nominal value and ±0.5 stability. At the higher temperatures the calibration The temperature probe was placed approximately 10 mm from the two reference probes. The calibration was performed in a climatic chamber.

How Does Chilled Mirror Technology Work? The chilled mirror sensor consists of a temperature-controlled mirror and an advanced optical detection system. RRS Michell Instruments S8000 sensors utilize our RRS Optical System to guarantee 0.01 (0.018 F) sensitivity and the fastest dynamic response to dew points as low as 90 ( 130 F). The system employs active monitoring and adjustment to automatically rebalance the optics to accommodate any changes in the signal level not associated with condensed moisture. 3 1 5 4 2 6 7 A beam of light from an LED (1) is focused on the mirror surface (2) with a fixed intensity. As the mirror is cooled, less light is reflected due to the scattering effect of the condensate formed on the mirror surface. The levels of reflected and scattered light are measured by two photo-detectors (3 & 4) and compared against a third reference detector (5) measuring the intensity of light from the LED. The signals from this optics system are used to precisely control the drive to a solid state thermoelectric cooler (TEC) (6), which heats or cools the mirror surface. The mirror surface is then controlled in an equilibrium state whereby evaporation and condensation are occurring at the same rate. In this condition, the temperature of the mirror, measured by a platinum resistance thermometer (7), is equal to the dew-point temperature of the gas. In the S8000 RS, and S4000 TRS, an auxiliary cooling system is used to remove heat from the hot side of the TEC. This supplements the depression capabilities of the heat pump, and enables measurement of very low dew points.

Optidew Series The Optidew Series is Michell Instruments entry-level range of chilled mirror hygrometers, offering a feature-complete instrument at an affordable price. The Optidew Series includes DCC, FAST, digital RS232 or RS485 communications, analog current loop outputs, alarm relays, optional display, and bundled PC application software as standard. The Optidew Series remote chilled mirror sensor offers a wide measurement range from the equivalent of <0.5 to 100% RH at ambient temperature. This equates to a dew-point range of 40 to +90 ( 40 to +194 F), with accuracy of ±0.2 (±0.36 F) dew point and ±0.1 (±0.18 F) temperature across the entire measurement range. A selection of corrosion resistant sensor materials are available, along with high pressure (up to 250 barg / 3625.9 psig) and high temperature (up to +130 (+266 F)) versions, making it possible to use the sensor in even the most demanding industrial applications. A special version of the sensor is also available that has been optimized for environmental monitoring applications, such as climatic chambers. Optidew The Optidew is supplied in a rugged IP66, NEMA 4X, 304 stainless steel wall-mount enclosure, making it ideal for industrial applications, or outdoor installation. Precision process dew point, %RH and temperature measurement Measurement Range: <0.5 to 100% RH, 40 to +90dp ( 40 to +194 Fdp) ±0.2dp (±0.36 Fdp) accuracy (±0.15 (±0.27 F) optional) Fundamental drift-free dew-point measurement Rugged NEMA 4X industrial housing High temperature sensor option to +130 (+266 F) Optional local display Optidew Vision The Optidew Vision has all the same great features as the Optidew, but is supplied in a bench-top package with a carry handle, making it perfect for laboratory use. Fundamental drift-free dew-point measurement Convienient, transportable package ±0.2dp accuracy; optional higher accuracy available High temperature sensor option to +130 (+266 F) NEMA-12 bench-top housing Display and output of multiple engineering units High pressure sensor option to 25 MPa (250 barg / 3625.9 psig)

S8000 Series Michell s S8000 Series of chilled mirror reference hygrometers provide extremely accurate and precise measurement of dew point, relative humidity and temperature. These feature-rich modern laboratory instruments include an intuitive user-interface, built-in data logging, digital and analog outputs, and comprehensive application software. The S8000 Series chilled mirror sensors ±0.1 (±0.18 F) dew-point accuracy, coupled with the ±0.1 (±0.18 F) accuracy of the remote temperature probe provides highly precise relative humidity measurement. With an accuracy of 1% RH or better (up to 70% RH) and 1.5% RH or better (between 70 to 98% RH), the S8000 series gives the highest available relative humidity accuracy of any chilled mirror instrument on the market. S8000 Integrale The S8000 Integrale features an integrated sensor head allowing measurement to 60dp ( 76 Fdp), making it suitable for a range of calibration applications. This dew-point reference instrument combines the measurement sensitivity and accuracy of the RRS system, with light weight construction and flexibility for dynamic measurements or for use as a calibration reference standard. Fundamental, accurate and drift-free measurement Rapid measurement response speed 60 to +40dp ( 76 to +104 Fdp) measurement range ±0.1dp (±0.18 Fdp) accuracy Operates at pressures up to 2.0 MPa (20 barg / 290.1 psig Simple configuration and operation via touch screen interface S8000 Remote The S8000 Remote has all the great features of the other S8000 Series chilled mirror hygrometers, but with a convenient and compact remote sensor design. The relative humidity in climatic chambers will always deviate from the set point. Even in high precision chambers this deviation is typically between 1 to 3% RH, which can have a considerable effect on the results of many tests. The S8000 Remote can reduce this uncertainty to just 0.5% RH, depending on set point. The compact remote sensor takes up minimal space in the chamber and features an open cell design, removing the need for any complex heated sampling arrangements or an external pump. Fundamental, accurate and drift-free measurement Remote sensor Open design allows the remote sensor to be mounted into a sample flow or simply placed in an environment to be monitored 40 to +90 ( 40 to +194 F) dew-point range with ±0.1 (±0.18 F) accuracy Sensor operates in pressures up to 2 MPa (20 barg / 290 psig)

S8000 RS Michell s flagship chilled mirror hygrometer, capable of measuring as low as 90 ( 130 F) dew point with no external cooling or bulky refrigeration unit. The sensor head construction has been optimized for fast response to low dew points, with the RRS system ensuring precision and accuracy across the measurement range. The S8000 RS is our first chilled mirror instrument to feature a touch screen, providing a user-friendly and powerful interface for the control and configuration of all the instrument s features and parameters. Accuracy of ±0.1 (±0.18 F) Precision measurement to 90 ( 130 F) dew point (100 ppb) with no need for additional cooling Simple configuration and operation via touch-screen interface Sensor head optimized for fast response to low moisture levels High measurement sensitivity Microscope for visual inspection of condensate on mirror Compact 19 x 4U package for flexibility of installation Lightweight at 17kg (37.5lbs) less than half the weight of its closest competitor S4000 Series The Michell Instruments S4000 Series of chilled mirror hygrometers is available in two distinct models: the S4000 TRS for very dry dew-point measurements to 100 ( 148 F), and the S4000 RC for a dynamic range of wet and dry measurements. Both models feature 0.1 (0.18 F) dew-point and temperature measurement accuracy. The S4000 Series is supplied with all the standard features of our other chilled mirror hygrometers including dynamic contamination control, a microscope for visual identification of the condensate, RS232 digital communications, and both current and voltage analog outputs. S4000 TRS The S4000 TRS was developed from the TSDH (Transfer Standard Dew-Point Hygrometer), which was selected to provide transfer of the trace humidity standard between the NPL (National Physical Laboratory, London, UK) and NIST (National Institute of Standards & Technology, Washington DC, USA), on account of its excellent stability and reproducibility. Its descendant the S4000 TRS, is now widely used in calibration and standards laboratories worldwide, in recognition of these characteristics in addition to its long term reliability. S4000 RC The S4000 RC features a monolithic sensor block for mounting in climatic chambers and other controlled environments. It is built with the same high quality sensing components as the S4000 TRS, but can operate over a wide range of environmental temperatures resulting in a measurement range of 80 to +85 ( 112 to +185 F) dew point.

Services Guide Chilled Mirror Instruments We invite you to take advantage of our full range of support services to maintain your instrument and to keep its calibration up to date for absolute confidence in your moisture measurements. Calibration Services Michell Instruments offers a calibration service for most moisture sensors and instrumentation, carried out in our ISO17025, ISO9001:2008 certified laboratories. Our four laboratories are accredited by UKAS (United Kingdom Accreditation Service), and maintain full traceability to NPL (National Physical Laboratory, London, UK) & NIST (National Institute of Standards and Technology, Washington DC, USA). Extended Maintenance Agreement Michell s extended maintenance agreement includes application support, full annual service including traceable calibration or sensor exchange, free software upgrades and repairs (if required). A regular calibration schedule is the best way to maintain traceability to national standards, so customers soon recoup the cost of the agreement, as well as benefiting from peace of mind and increased reliability that comes from the regular servicing and maintenance of the covered instruments. Customization Projects Where a standard product doesn t quite meet the needs of an application, Michell s team of design engineers will work with you to develop a specific solution. From specialized sampling systems, to something as simple as a different connector, Michell s 40 years of experience in moisture measurement enables us to find the best fit for specific moisture measurement needs. Other Product Ranges Portable Instruments Dew-Point Transmitters & Instruments Process Analyzers Calibration Instruments Relative Humidity Instruments Oxygen & Binary Gas Analyzers Michell Instruments, Inc 319 Newburyport Turnpike, Suite 207, Rowley, MA 01969 Tel: 978 484 0005, Fax: 978 843 7669, Email: us.info@michell.com, Web: /us Michell Instruments adopts a continuous development programme which sometimes necessitates specification changes without notice. Issue no: Chilled Mirror_97138_V5.1_US_0716