Analysis and Purification of Diastereomeric Steroid Saponins from the Trigonella foenum-graecum Seed Extract Using SFC/ELSD

Similar documents
Enantiomeric and Diastereomeric Separations of Pyrethroids Using UPC 2

Multi-Channel SFC System for Fast Chiral Method Development and Optimization

Expediting Achiral SFC Method Development Using a Multi-Channel SFC System with MS Detection

Basic Principles for Purification Using Supercritical Fluid Chromatography

UPC 2 Strategy for Scaling from Analytical to Preparative SFC Separations

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Effects of Aqueous Sample Content and Aqueous Co-Solvent Composition on UPC 2 Separation Performance

Peptide Isolation Using the Prep 150 LC System

Routine MS Detection for USP Chromatographic Methods

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

Analysis of Saponins in Spine Date Seed using Agilent ZORBAX Solvent Saver HT (1.8 µm) Columns

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Dilution(*) Chromatography

Application Note. Authors. Abstract. Pharmaceuticals

Integration of normal phase liquid chromatography with supercritical fluid chromatography for analysis of fruiting bodies of Ganoderma lucidum

An Investigation of the Impact of Common Experimental Parameters on Signal Intensity in SFC ESI MS

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

Electron Transfer Dissociation of N-linked Glycopeptides from a Recombinant mab Using SYNAPT G2-S HDMS

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Solvent Flexibility for Size-Based Polymer Analysis Using the Advanced Polymer Chromatography (APC) System

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

Multi-stage Mass Spectrometry up to MS 4 on a QTof System

A novel approach to the analysis of multivitamin by online supercritical fluid extraction/supercritical fluid chromatography

LC Technical Information

Analysis of Organic Light Emitting Diode Materials by UltraPerformance Convergence Chromatography Coupled with Mass Spectrometry (UPC 2 /MS)

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Sesquiterpenoids with PTP1B Inhibitory Activity and Cytotoxicity. from the Edible Mushroom Pleurotus citrinopileatus

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

Determination of Gallic acid from their Methanolic Extract of Punica granatum By HPLC Method

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Evaluation of Ketone Containing Terpene Compounds using Evaporative Light Scattering Detection

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

LC-MS compatible Separation of the Fungicide Spiroxamine

UPC 2 Method Development for Achiral Impurity Analysis

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

Preparative Chromatography with Improved Loadability

[ a ppl ic at ion no t e ]

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

ANALYSIS OF BASIC COMPOUNDS

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Impact of Instrument Dispersion on Performance of HPLC Capillary Columns

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Agilent 385-ELSD Evaporative Light Scattering Detector

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

1Determination of optical purity of N-acetyl-1-naphthylethylamine by chiral chromatography and NMR spectroscopy

Fast methods for the determination of ibuprofen in drug products

with diode array detection

How to Troubleshoot a Failed System Suitability Test

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Use of High Speed/High Resolution Size-Based Chromatographic Separation of Polymeric Mixtures with Offline Infrared Detection

Agilent 385-ELSD Evaporative Light Scattering Detector

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Nexera UC Unified Chromatography

APPLICATION NOTE Goal. Introduction. Keywords

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

ACD/AutoChrom Assisted Method Development for Challenging Separations. Vera Leshchinskaya February 7, 2018

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

PosterREPRINT AN INTERACTIVE PHYSICOCHEMICAL PROPERTY PROFILING SOFTWARE FOR EARLY CANDIDATE ANALYSIS IN DRUG DISCOVERY INTRODUCTION

Easy Method Transfer from HPLC to RSLC with the Dionex Method Speed-Up Calculator

Minimizing Solvent Impact on Purification of Nitrogencontaining

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

Application Note. Edgar Naegele. Abstract

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Chiral Separation Using SFC and HPLC

Use of the SFC-MS Splitter Kit G

Automatization for development of HPLC methods

Identification of Human Hemoglobin Protein Variants Using Electrospray Ionization-Electron Transfer Dissociation Mass Spectrometry

SEPARATION OF FLURBIPROFEN AND IBUPROFEN ENANTIOMERS ON A CHIRAL STATIONARY PHASE USING SUPERCRITICAL FLUIDS

Refractive Index Detection Using an Ultraviolet Detector with a Capillary Flow Cell in Preparative SFC

Rapid quantification of Chinese medicine Zuo Jin Pill using rapid resolution liquid chromatography

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Analysis of Star Polymers Using the Agilent 1260 Infinity Multi-Detector GPC/SEC System

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Monitoring Protein PEGylation with Ion Exchange Chromatography

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

A rapid and highly selective colorimetric method for direct detection of tryptophan in proteins via DMSO acceleration

Transcription:

Analysis and Purification of Diastereomeric Steroid Saponins from the Trigonella foenum-graecum Seed Extract Using SFC/ELSD John McCauley, 1 Liping Kang, 2 Heshui Yu, 2 Baiping Ma, 2 and Rui Chen 1 1 Waters Corporation, Milford, MA, USA 2 Beijing Institute of Radiation Medicine, Beijing, P. R. China A P P L I C AT IN B E N E F I T S The structural complexity of steroid saponins presents a daunting challenge in resolving their stereoisomers, especially those 25 R/S diastereomers. As a result, bioassays are often performed on the isomeric mixtures, which might lead to skewed results. Here, we demonstrate the first successful separation of a pair of 25 R/S spirostanol saponin diastereomers using supercritical fluid chromatography (SFC). SFC complements HPLC and offers unique capability and flexibility for stereoisomeric resolution. INT R DU C T IN Biosynthesis enzymes are inherently three-dimensional. As a result, enzymatically-derived natural products are usually structurally diverse, sterically complex, and chiral. Compared to synthetic compounds, natural products contain significantly more rings and chiral centers. 1 For example, steroid saponins are an important class of compounds widely distributed in plant and marine animal kingdoms. They are glycosides consisting of one or more oligosaccharide chains, linked to a steroid aglycone with multiple five- and six-member ring structures. In addition to different oligosaccharides, stereochemistry at C-25 also contributes to their structural variability. Spirostanol saponins, shown in Figure 1, are a subgroup of steroid saponins, and refer to those containing spirostane-type of aglycones. S C-25 R C-25 H H WAT E R S S LU T INS Method Station SFC System H H H H H H H H H 3 C H H 3 C H H H H Figure 1. Chemical structures of a spirostanol saponin. H Investigator SFC System 2424 Evaporative Light Scattering Detector (ELSD) MassLynx Software ChromScope Software K E Y W R D S Natural product, Traditional Chinese Medicine, spirostanol saponin, diastereomer, SFC, ELSD, column coupling, purification, stacked injections Steroid saponins show many pharmacological activities, including anticancer, cytotoxicity, anti-inflammatory, antioxidant, antiviral, antifungal, and antimicrobial, to name a few. For example, the seeds of Trigonella foenum-graecum L. are rich in steroid saponins and have long been used as a remedy for tonic and stomachic purposes in Traditional Chinese Medicine (TCM). 2 There is a substantial research effort to isolate steroid saponins from various plants using TLC and HPLC, followed by structural elucidation and bioassays. 3-6 However, the structural complexity of steroid saponins presents a daunting challenge in resolving their stereoisomers, especially those 25 R/S diastereomers. To date, there has not been a successful resolution of 25 R/S spirostanol saponin isomers by any chromatographic technique. 7-8 Instead, bioassays were performed on the isomeric mixtures, which might lead to skewed results as optical isomers could possess considerably different bioactivities. 1

E X P E R IM E N TA L SFC method conditions Analytical SFC Flow rate: 3.5 ml/min Co-solvent: Methanol Back pressure: 120 bar Temp.: 40 C Co-solvent percentage: 33% Herein, we report the chromatographic resolution of a pair of 25 R/S spirostanol saponin diastereomers from the Trigonella foenum-graecum L. seed extract using SFC/ELSD, both analytically and preparatively. The advantages of using SFC for spirostanol saponin analysis and purification are discussed. Instrumentation: Analytical method development was performed on a Waters Method Station SFC System controlled by MassLynx Software. The Method Station SFC System consists of the following components: Fluid Delivery Module (FDM), Automated Back Pressure Regulator (ABPR), Alias Autosampler, 10-port Analytical-2-Prep Column ven, and 2424 Evaporative Light Scattering Detector (ELSD). Column: ELSD: CHIRALPAK IC (4.6 x 150 mm or 250 mm or 400 mm, 5 µm) N 2 pressure: 35 psi, Drift tube temp.: 60 C, Nebulizer heater: 85% All preparative experiments were performed on a Waters Investigator SFC System controlled by ChromScope Software. The Investigator SFC System consists of the following components: FDM, ABPR, Alias Autosampler, 10-port Analytical-2-Prep Column ven, 2424 ELSD, make-up pump, and six-position Fraction Collection Module. A tee was placed immediately before the ABPR to split the flow to the ELSD and the ABPR at a ratio of approximately 1:20. Injection vol.: 10 µl Preparative SFC Flow rate: 3.5 ml/min Co-solvent: Methanol Back pressure: 120 bar Temp.: 40 C Co-solvent percentage: 33% Column: CHIRALPAK IC (4.6 x 150 mm, 250 mm, or 400 mm, 5 µm) ELSD: N 2 pressure: 35 psi, Drift tube temp.: 60 C, Nebulizer heater: 85% Injection vol.: 75 µl Chemicals: SFC-grade C 2 was provided by Air Gas (Salem, NH, USA). HPLC-grade methanol was purchased from Thermo Fisher Scientific (Fair Lawn, NJ, USA). Sample preparation: The seeds of Trigonella foenum-graecum L. were purchased from Anguo, Hebei province, China. Extraction and isolation were previously described elsewhere. 9 The sample was white, amorphous powder dissolved in methanol at approximately 1 mg/ml prior to SFC. R E SU LT S A N D D IS C U S S IN With very few exceptions, most saponins do not possess chromophores necessary for UV detection. Therefore, ELSD and MS have been coupled to HPLC for detection of saponins. 10-11 In our experiments, we chose ELSD as the choice of detection to ensure the continuity between analysis and purification. Since ELSD response is highly dependent on the co-solvent percentage, 12 isocratic methods were developed for the separation of the 25 R/S spirostanol saponin diastereomers, to accurately assess the isocratic ratio. Figure 2 shows the RPLC/ELSD, and SFC/ELSD chromatograms. No separation was observed with RPLC. Using a 250-mm CHIRALPAK IC column, the resolution of the isomeric pair was 1.76 and the isomeric ratio (peak 1/peak 2) was 0.64. 2

140.00 120.00 (A) RPLC 100.00 mv 80.00 60.00 40.00 20.00 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 75 70 (B) SFC 65 60 55 50 45 40 35 30 25 20 15 10 5 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 Time Figure 2. RPLC/ELSD (A) and SFC/ELSD (B) chromatograms of the spirostanol saponin diastereomers. RPLC method conditions were the following: Lichrospher C 18 (4.6 x 250 mm, 5 μm) column; column heater: 35 C; mobile phase: 83:17 methanol/water; flow rate: 1.0 ml/min. SFC method conditions are listed in the experimental section. Resolution has a direct impact on sample loadability in preparative chromatography. A successful preparative chromatography often requires a resolution of 2 or greater. In an effort to further improve the resolution, two IC columns (150 mm and 250 mm) were coupled in tandem, and the resulting chromatograms are shown in Figure 3. The resolution and isomeric ratio for each run were calculated, and are summarized in Table 1. 75 (A ) 150 mm 50 25 0.00 5.00 10.00 15.00 20.00 25.00 60 (B) 250 mm 40 20 0.00 5.00 10.00 15.00 20.00 25.00 60 (B) 400 mm 40 20 Time 0.00 5.00 10.00 15.00 20.00 25.00 Figure 3. SFC/ELSD chromatograms of the spirostanol saponin diastereomers with different column lengths. 3

Clearly, as the column length increased, the retention time increased proportionally, while the resolution also increased. The extent of the resolution improvement tracks well with those from theoretical predications, as described by equations 1 and 2. The isomeric ratios were consistent among all three runs, indicating the column coupling approach taken in our experiments did not cause any peak distortion or sacrifice the chromatographic integrity. Additional peak dispersion, due to increased column length, did not seem to have a noticeable detrimental impact on resolution enhancement. There are two possible factors contributing to this observation. First, high flow rates are often used in SFC, which in turn minimize the analyte residence time on column and reduce the longitudinal dispersion; and secondly, the dispersion resulting from the resistance to mass transfer is also minimal in SFC because of the high diffusivity of liquid C 2. 1 4 N= L d p k k + 1 Equation 1 Equation 2 Increasing column length is one of the most fundamental and facile means to improve chromatographic resolution. However, it is less commonly used in HPLC, due to the limitation posed by the pressure drop across the column, as depicted in equation 3. P= 250LηF d c 2d p 2 Equation 3 Column coupling has been used for both analytical and preparative SFC, 13-15 when selectivity or retentivity was inadequate to improve resolution. Compared with HPLC, SFC holds a unique advantage because of the low viscosity of liquid C 2. The viscosity of the liquid C 2 under typical SFC conditions is 10- to 100-fold lower than those commonly used HPLC solvents; hence, effectively offsetting the P elevation resulting from longer columns. Column length (mm) 2(t 2 t 1 ) 1.7(w 0.5,1 +w 0.5,2 ) t 1 (min) t 2 (min) w 0.5,1 w 0.5,2 Isomeric ratio (peak1/peak2) R s = *, where t is the retention time and w 0.5 is the peak width at half height. *R s Increase Theoretical increase 150 7.14 7.95 0.34 0.39 0.62 1.31 0% 0% 250 11.21 12.54 0.44 0.48 0.64 1.71 31% 29% 400 18.20 20.33 0.55 0.58 0.64 2.23 70% 63% Table 1. Comparison of three SFC runs with different column lengths. 4

Next, the optimized method with two IC columns was transferred to the Investigator SFC System for preparative runs. Figure 4 shows a representative SFC/ELSD chromatogram with five stacked injections. With 75-µL injections, baseline resolution was well maintained, allowing for high purity compound collection. Despite the 20-min run time for each injection, with stacked injections, five runs were completed in less than 60 min. Stacked injections is an effective means to improve productivity without compromising chromatographic efficiency. Performed under isocratic conditions, injections are made during the course of chromatography so that the first peak from a subsequent injection elutes off the column adjacent to the last peak from the preceding injection. The chromatographic space is efficiently populated by peaks from consecutive injections, resulting in noticeable savings of both time and solvents. Post purification analysis indicated 100% purity for both fractions, and the collections were subject to high resolution mass spectrometry (HRMS) and nuclear magnetic resonance (NMR) analyses (results not shown). Figure 4. SFC/ELSD chromatogram of the spirostanol saponin diastereomers showing five stacked injections. The shaded area indicates collected fractions. 5

C N C LUSINS We have demonstrated, for the first time, the successful chromatographic resolution of a pair of 25 R/S spirostanol saponin diastereomers using SFC. Leveraging the low viscosity of liquid C 2 used in SFC, two columns were coupled in tandem to achieve the desired resolution necessary for preparative runs. In preparative SFC, to circumvent the relative long chromatography time, stacked injections were employed to save both time and solvents. As isomeric separation is often a prerequisite for accurate bioassays in natural product drug discovery, SFC readily lends itself as a complementary chromatographic technique to HPLC, especially for diastereomeric resolution. References 1. Krastel P, Peterson F, Roggo S, and Schmitt E. Aspects of Chirality in Natural Products Drug Discovery in Chirality in Drug Research, Francotte E, and Lindner Wolfgang Eds. Weinheim, Wiley-VCH Verlag GmbH & Co. KGaA, 2006; 67-94. 2. Pharmacopoeia of People s Republic of China, Volume 1. Beijing: People s Press, 2010; 225-226. 3. Dinan L, Harmatha J, and Lafont R. J. Chromatogr. A, 2001; 935, 105-123. 4. leszek WA. J. Chromatogr. A, 2002; 967, 147-162. 5. leszek WA, and Bialy Z. J. Chromatogr. A, 2006; 1112, 78-91. 6. Vincken J-P, Heng L, Groot A, and Gruppen H. Phytochemistry, 2007; 68, 275-297. 7. Zheng Q, Zhang Y, Li H, and Yang C. Steroids, 2004; 69, 111-119. 8. Miyakoshi M, Tamura Y, Masuda H, Mizutani K, Tanaka, Ikeda T, htani K, Kasai R, and Yamasaki K. J. Nat. Prod., 2000; 63, 332-338. 9. Yu H, Zhang J, Kang L, Han L, Zou P, Zhao Y, Xiong C, Tam D, Song X, Yu K, and Ma B. Chem. Pharm. Bull., 2009; 57(1), 1-4. 10. Chai X, Li S, and Li P. J. Chromatogr. A, 2005; 1070, 43-48. 11. Man S, Gao W, Zhang Y, Wang J, Zhao W, Huang L, and Liu C. J. Chromatogr. B, 2010; 878, 2943-2948. 12. DePhillipo T, Lefler JL, and Chen R. LCGC Europe, Applications Notebook Supplement, 2009; 22(3), 38-39. 13. Phinney KW, Sander LC, and Wise SA. Anal. Chem., 1998; 70, 2331-2335. 14. Barnhart WW, Gahm KH, Thomas S, Notari S, Semin D, and Cheetham J. J. Sep. Sci., 2005; 28, 619-626. 15. Lefler J and Chen R. LCGC, The Peak E-zine, 2008 March; 7-15. Waters is a registered trademark of Waters Corporation. The Science of What s Possible, MassLynx, ChromScope, and Analytical-2-Prep are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 2012 Waters Corporation. Produced in the U.S.A. April 2012 720004208EN AG-PDF Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com