Free-electron laser: Introduction :

Similar documents
Free Electron Laser. Project report: Synchrotron radiation. Sadaf Jamil Rana

The peak brilliance of VUV/X-ray free electron lasers (FEL) is by far the highest.

4 FEL Physics. Technical Synopsis

Coherence properties of the radiation from SASE FEL

Free-electron laser SACLA and its basic. Yuji Otake, on behalf of the members of XFEL R&D division RIKEN SPring-8 Center

X-ray Free-electron Lasers

SPARCLAB. Source For Plasma Accelerators and Radiation Compton. On behalf of SPARCLAB collaboration

Research Topics in Beam Physics Department

Lecture 1 August 29

Liverpool Physics Teachers Conference July

Electron Linear Accelerators & Free-Electron Lasers

MAX IV, NSLS II, PLS II, LCLS, SACLA, European XFEL,

Free-Electron Lasers

Linac Based Photon Sources: XFELS. Coherence Properties. J. B. Hastings. Stanford Linear Accelerator Center

INNOVATIVE IDEAS FOR SINGLE-PASS FELS

Insertion Devices Lecture 2 Wigglers and Undulators. Jim Clarke ASTeC Daresbury Laboratory

Research with Synchrotron Radiation. Part I

Harmonic Lasing Self-Seeded FEL

CONCEPTUAL STUDY OF A SELF-SEEDING SCHEME AT FLASH2

NON LINEAR PULSE EVOLUTION IN SEEDED AND CASCADED FELS

The Free Electron Laser: Properties and Prospects 1

Update on and the Issue of Circularly-Polarized On-Axis Harmonics

First operation of a Harmonic Lasing Self-Seeded FEL

The SCSS test accelerator Free-Electron Laser seeded by harmonics produced in gas

SLAC Summer School on Electron and Photon Beams. Tor Raubenheimer Lecture #2: Inverse Compton and FEL s

An Adventure in Marrying Laser Arts and Accelerator Technologies

3. Synchrotrons. Synchrotron Basics

Echo-Enabled Harmonic Generation

FLASH overview. Nikola Stojanovic. PIDID collaboration meeting, Hamburg,

Introduction to Free Electron Lasers and Fourth-Generation Light Sources. 黄志戎 (Zhirong Huang, SLAC)

The European XFEL in Hamburg: Status and beamlines design

Introduction to electron and photon beam physics. Zhirong Huang SLAC and Stanford University

Brightness and Coherence of Synchrotron Radiation and Free Electron Lasers. Zhirong Huang SLAC, Stanford University May 13, 2013

arxiv: v1 [physics.acc-ph] 1 Jan 2014

Experimental Path to Echo-75 at NLCTA

START-TO-END SIMULATIONS FOR IR/THZ UNDULATOR RADIATION AT PITZ

Hiromitsu TOMIZAWA XFEL Division /SPring-8

USPAS course on Recirculated and Energy Recovered Linacs Ivan Bazarov, Cornell University Geoff Krafft, JLAB. ERL as a X-ray Light Source

Laserphysik. Prof. Yong Lei & Dr. Yang Xu. Fachgebiet Angewandte Nanophysik, Institut für Physik

1 Introduction. 1.1 Accelerator-based light sources. Introduction

Investigation of the Feasibility of a Free Electron Laser for the Cornell Electron Storage Ring and Linear Accelerator

Introduction to Synchrotron Radiation

Modern optics Lasers

FURTHER UNDERSTANDING THE LCLS INJECTOR EMITTANCE*

A two-oscillator echo enabled tunable soft x-rays

The Broadband High Power THz User Facility at the Jefferson Lab - FEL

Far IR (FIR) Gas Lasers microns wavelengths, THz frequency Called Terahertz lasers or FIR lasers At this wavelength behaves more like

Linac Driven Free Electron Lasers (III)

Free-electron lasers as sources of extremely brilliant x-ray radiation (Introduction European XFEL)

Some Sample Calculations for the Far Field Harmonic Power and Angular Pattern in LCLS-1 and LCLS-2

Polarization control experiences in single pass seeded FELs. Carlo Spezzani on behalf of

MULTI-DIMENSIONAL FREE-ELECTRON LASER SIMULATION CODES: A COMPARISON STUDY *

Far IR Gas Lasers microns wavelengths, THz frequency Called Terahertz lasers or FIR lasers At this wavelength behaves more like

FLASH/DESY, Hamburg. Jörg Rossbach University of Hamburg & DESY, Germany - For the FLASH Team -

Layout of the HHG seeding experiment at FLASH

Cooled-HGHG and Coherent Thomson Sca ering

Steady State Analysis of Short-wavelength, High-gain FELs in a Large Storage Ring. Abstract

Transverse Coherence Properties of the LCLS X-ray Beam

Introduction to single-pass FELs for UV X-ray production

Undulator radiation from electrons randomly distributed in a bunch

FUTURE SRF-LINAC BASED LIGHT SOURCES: INITIATIVES AND ISSUES *

Generating intense attosecond x-ray pulses using ultraviolet-laser-induced microbunching in electron beams. Abstract

Generation and characterization of ultra-short electron and x-ray x pulses

Coherence Properties of the Radiation from X-ray Free Electron Lasers

Baryshevsky V., Gurinovich A., Gurnevich E., Lobko A.

Greenfield FELs. John Galayda, SLAC Kwang-Je Kim, ANL (Presenter) James Murphy, BNL

Research Laboratory for Quantum Beam Science

parameter symbol value beam energy E 15 GeV transverse rms beam size x;y 25 m rms bunch length z 20 m charge per bunch Q b 1nC electrons per bunch N b

Characterization of an 800 nm SASE FEL at Saturation

Beam Echo Effect for Generation of Short Wavelength Radiation

VARIABLE GAP UNDULATOR FOR KEV FREE ELECTRON LASER AT LINAC COHERENT LIGHT SOURCE

Traveling Wave Undulators for FELs and Synchrotron Radiation Sources

Introduction to Particle Accelerators & CESR-C

Short Wavelength SASE FELs: Experiments vs. Theory. Jörg Rossbach University of Hamburg & DESY

OPTICAL GAIN AND LASERS

Towards a Low Emittance X-ray FEL at PSI

Progress Report on the LCLS XFEL at SLAC

The MID instrument.

NSLS Source Development Laboratory

High Energy Gain Helical Inverse Free Electron Laser Accelerator at Brookhaven National Laboratory

ASTRA simulations of the slice longitudinal momentum spread along the beamline for PITZ

29th International Free Electron Laser Conference 2007

Generation of GW-level, sub-angstrom Radiation in the LCLS using a Second-Harmonic Radiator. Abstract

Performance Metrics of Future Light Sources. Robert Hettel, SLAC ICFA FLS 2010 March 1, 2010

Analysis of FEL Performance Using Brightness Scaled Variables

Synchrotron radiation: A charged particle constrained to move in curved path experiences a centripetal acceleration. Due to it, the particle radiates

Radiological safety studies for the TeraFERMI beamline at

Theory of Nonlinear Harmonic Generation In Free-Electron Lasers with Helical Wigglers

PAL LINAC UPGRADE FOR A 1-3 Å XFEL

X-ray free-electron lasers: An introduction to the physics and main characteristics

Radiation Safety at LCLS: The Photon Beam s Maximum Capability and Material Damage Potential

Trends in X-ray Synchrotron Radiation Research

Fundamental and Harmonic Microbunching Measurements in a High-Gain, Self-amplified, Spontaneous Emission Free-Electron Laser

Synchrotron Radiation in IRAN

Diagnostic Systems for Characterizing Electron Sources at the Photo Injector Test Facility at DESY, Zeuthen site

SPARCLAB. Source For Plasma Accelerators and Radiation Compton with Laser And Beam

The history of X-ray free-electron lasers

The spectrum of electromagnetic waves stretches from radio waves to gamma rays (Fig. VIII-1).

SUPPLEMENTARY INFORMATION

X-Band RF Harmonic Compensation for Linear Bunch Compression in the LCLS

Transcription:

Free-electron laser: Free-electron laser FELIX at FOM (Nieuwegein) Introduction : A free-electron laser, or FEL, is a laser that shares the same optical properties as conventional lasers such as emitting a beam consisting of coherent electromagnetic radiation which can reach high power, but which uses some very different operating principles to form the beam. Unlike gas, liquid, or solid-state lasers such as diode lasers, in which electrons are excited in bound atomic or molecular states, FELs use a relativistic electron beam as the lasing medium which moves freely through a magnetic structure, hence the term free electron. [1] The free-electron laser has the widest frequency range of any laser type, and can be widely tunable, [2] currently ranging in wavelength from microwaves, through terahertz radiation and infrared, to the visible spectrum, to ultraviolet, to X- rays. [3] Free-electron lasers were invented by John Madey in 1976 at Stanford University. The work emanates from research done by Hans Motz and his coworkers who built an undulator at Stanford in 1953 using the wiggler magnetic configuration which is at the heart of a free electron laser. Madey used a 24 MeV electron beam and 5 m long wiggler to amplify a signal. Soon afterward, other laboratories with accelerators started developing such lasers. A Free Electron Laser generates tunable, coherent, high power radiation, currently spanning wavelengths from millimeter to visible and potentially ultraviolet to x-ray. It can have the optical properties characteristic of conventional lasers such as high spatial coherence and a near diffraction limited radiation beam. It differs from conventional lasers in using a relativistic electron beam as its lasing medium, as opposed to bound atomic or molecular states, hence the term free-electron. 1

Beam creation : Free electron laser schematic of operation Undulator of FELIX To create a FEL, a beam of electrons is accelerated to almost the speed of light. The beam passes through the FEL oscillator, a periodic transverse magnetic field produced by an arrangement of magnets with alternating poles within a optical cavity along the beam path. This array of magnets is sometimes called an undulator, or a "wiggler", because it forces the electrons in the beam to follow a sinusoidal path. The acceleration of the electrons along this path results in the release of photons (synchrotron radiation). Since the electron motion is in phase with the field of the light already emitted, the fields add together coherently. Whereas conventional undulators would cause the electrons to radiate independently, instabilities in the electron beam resulting from the interactions of the oscillations of electrons in the undulators and the radiation they emit leads to a bunching of the electrons, which continue to radiate in phase with each other. [4] The wavelength of the light emitted 2

can be readily tuned by adjusting the energy of the electron beam or the magnetic field strength of the undulators. Accelerators Today, a free-electron laser requires the use of an electron accelerator with its associated shielding, as accelerated electrons are a radiation hazard. These accelerators are typically powered by klystrons, which require a high voltage supply. The electron beam must be maintained in a vacuum which requires the use of numerous vacuum pumps along the beam path. While this equipment is bulky and expensive, free-electron lasers can achieve very high peak powers, and the tunability of FELs makes them highly desirable in several disciplines, including medical diagnosis and nondestructive testing. X-ray uses The lack of suitable mirrors in the extreme ultraviolet and x-ray regimes prevents the operation of a FEL oscillator; consequently, there must be suitable amplification over a single pass of the electron beam through the undulator to make the FEL worthwhile. X-ray free electron lasers use long undulators. The underlying principle of the intense pulses from the X-ray laser lies in the principle of self-amplified stimulated emission (SASE), which leads to the microbunching of the electrons. Initially all electrons are distributed evenly and they emit incoherent spontaneous radiation only. Through the interaction of this radiation and the electrons' oscillations, they drift into microbunches separated by a distance equal to one radiation wavelength. Through this interaction, all electrons begin emitting coherent radiation in phase. In other words, all emitted radiation can reinforce itself perfectly whereby wave crests and wave troughs are always superimposed on one another in the best possible 3

way. This results in an exponential increase of emitted radiation power, leading to high beam intensities and laser-like properties. [5] Examples of facilities operating on the SASE FEL principle include the Free electron LASer (FLASH) in Hamburg, the Linac Coherent Light Source (LCLS) at the SLAC National Accelerator Laboratory, the European x-ray free electron laser (XFEL) in Hamburg, the SPring-8 Compact SASE Source (SCSS), the SwissFEL at the Paul Scherrer Institute (Switzerland) and, as of 2011, the SACLA at the RIKEN Harima Institute in Japan. One problem with SASE FELs is the lack of temporal coherence due to a noisy startup process. To avoid this, one can "seed" an FEL with a laser tuned to the resonance of the FEL. Such a temporally coherent seed can be produced by more conventional means, such as by high-harmonic generation (HHG) using an optical laser pulse. This results in coherent amplification of the input signal; in effect, the output laser quality is characterized by the seed. While HHG seeds are available at wavelengths down to the extreme ultraviolet, seeding is not feasible at x-ray wavelengths due to the lack of conventional x-ray lasers. In late 2010, in Italy, the seeded-fel source FERMI@Elettra http://www.elettra.trieste.it/fermi/ has started commissioning, at the Sincrotrone Trieste Laboratory. FERMI@Elettra is a single-pass FEL user-facility covering the wavelength range from 100 nm (12 ev) to 10 nm (124 ev), located next to the third-generation synchrotron radiation facility ELETTRA in Trieste, Italy. The advent of femtosecond lasers has revolutionized many areas of science from solid state physics to biology. This new research frontier of ultra-fast VUV and X-ray science drives the development of a novel source for the generation of femtosecond pulses. Test-stand for High-gain SASE Expts. l High-brightness electron beam l Diagnostics for electrons and photons 4

First Measurement of Large SASE Gain l Gain = 300 for the one-meter undulator Measurement of Largest SASE Gain l Gain = 10 5 for the two-meter undulator Observation of SASE-induced bunching 5

l Observation of coherent transition radiation l Results corroborate SASE measurements SASE Startup Studies 6

Transverse power distribution for the UCLA experiment predicted by FAST in the low gain regime The Pendulum Model: Many features of the dynamics of free electron lasers can be understood using a simple pendulum model. This model comes about because the electromagnetic wave (i.e., the laser field) and the magnetic field of the wiggler act in tandem on the electron to produce a sinusoidal potential similar to that of a pendulum in the earth's gravitational field, A (1- cos(ξ+φ)). The constant A will depends on a number of FEL parameters including the distance between the wiggler magnets, the strength of the wiggler field, and the energy of the injected electrons. But most importantly, A is proportional to the laser field strength. Imagine that an electron is part way up the potential well but falling toward the potential minimum at theta =0. The energy released by the electron increases the laser field and consequently lowers the minimum further. Conversely, electrons moving away from the potential minimum up the potential well decrease the laser field. Since many electrons are injected into the FEL simultaneously, the dynamics of the system can become very complex indeed. [6] 7

Equations of Motion: Both the equations of motion for individual electrons, d 2 ξ/dt 2 = A sin(ξ+φ) and the wave equation for the laser field, d A/ dt = -J <exp(-i ξ)> are solved by the FEL applet embedded in this document. The non-dimensional scaled parameters, A and J, are proportional to the optical field strength and the current density, respectively. The beam current density, J, determines the rate of change of the laser field, A. The phase of the laser field phase, φ, is of course the phase of the complex scalar, A. The position of the electron is determined by the pondermotive (or electron) phase, ξ. It is a measure of the position of an electron with respect to the beat wave between the electromagnetic and wiggler fields, ξ=(k u -k)z - ωt. The pendulum FEL model is valid for both weak or strong optical fields and for high or low gain. The theory does not include space charge effects, i.e., the electrons do not interact among themselves, nor does it include any off axis field dependence, i.e., the optical field is smoothly varying and one dimensional. The theory also assumes that the fractional energy change of the electron in passing through a single wiggler magnet is small. [7] Application; 1- Medical uses Research by Dr. Glenn Edwards and colleagues at Vanderbilt University's FEL Center in 1994 found that soft tissues like skin, cornea, and brain tissue could be cut, or ablated, using infrared FEL wavelengths around 6.45 micrometres with minimal collateral damage to adjacent tissue. [8]9] This led to further research and eventually surgeries on humans, the first ever using a free-electron laser. Starting in 1999, and using the Keck foundation funded FEL operating rooms at the Vanderbilt FEL Center, Dr. Michael Copeland and Dr. Pete Konrad of Vanderbilt performed three surgeries in which they resected meningioma brain tumors. [10] Beginning in 2000, Dr. Karen Joos and Dr. Louise Mawn 8

performed five surgeries involving the cutting of a window in the sheath of the optic nerve, to test the efficacy for optic nerve sheath fenestration. [11] These eight surgeries went as expected with results consistent with the routine standard of care and with the added benefit of laser surgery and minimal collateral damage. A review of FELs for medical uses is given in the 1st edition of Tunable Laser Applications. [12] Since these successful results, there have been several efforts to build small, clinical lasers tunable in the 6 to 7 micrometre range with pulse structure and energy to give minimal collateral damage in soft tissue. [citation needed] At Vanderbilt, there exists a Raman shifted system pumped by an Alexandrite laser. [13] At the 2006 annual meeting of the American Society for Laser Medicine and Surgery (ASLMS), Dr. Rox Anderson of the Wellman Laboratory of Photomedicine of Harvard Medical School and Massachusetts General Hospital reported on the possible medical application of the free-electron laser in melting fats without harming the overlying skin. [14] It was reported that at infrared wavelengths, water in tissue was heated by the laser, but at wavelengths corresponding to 915, 1210 and 1720 nm, subsurface lipids were differentially heated more strongly than water. The possible applications of this selective photothermolysis (heating tissues using light) include the selective destruction of sebum lipids to treat acne, as well as targeting other lipids associated with cellulite and body fat as well as fatty plaques that form in arteries which can help treat atherosclerosis and heart disease. [15] 2- Military uses : FEL technology is being evaluated by the US Navy as a good candidate for an anti aircraft and missile directed-energy weapon. Significant progress is being made in raising FEL power levels (the Thomas Jefferson National Accelerator Facility's FEL has demonstrated over 14 kw) [16] and it should be possible to build compact multi-megawatt class FEL weapons. [17] On June 9, 2009 the Office of Naval Research announced it had awarded Raytheon a contract to develop a 100 kw experimental FEL. [18] On March 18, 2010 Boeing Directed Energy Systems announced the completion of an initial design for U.S. Naval use. [19] A prototype FEL system has since been demonstrated with a full-power prototype scheduled by 2018. [20] 9

References: 1-"Duke University Free-Electron Laser Laboratory" http://www.fel.duke.edu/. Retrieved 2007-12-21. 2- F. J. Duarte (Ed.), Tunable Lasers Handbook (Academic, New York, 1995) Chapter 9. 3-"SLAC,NationalAcceleratorLaboratory". http://home.slac.stanford.edu/pressreleases/2009/20090421.htm. 4- Feldhaus et al., J. Phys. B: At. Mol. Opt. Phys. 38 (2005) S799 S819 5- "XFEL information webpages". http://xfelinfo.desy.de/en/start/2/index.html. Retrieved 2007-12-21. 6-W. B. Colson and A, M. Sessler, Ann. Rev. Nuc. Part. Sci., 1985 (35) 25-54. 7-H. P. Freund and R. K. Parker, Free Electron Lasers in Encyclopedia of Physical Science and Technology 1991 Yearbook, Academic Press, New York 199 8- Glenn Edwards et al., Nature 371 (1994) 416-419 9- "Laser light from Free-Electron Laser used for first time in human surgery". http://www.vanderbilt.edu/news/register/jan10_00/story5.html. Retrieved 2010-11-06. 10- Glenn S. Edwards et al., Rev. Sci. Instrum. 74 (2003) 3207 11- Karen M. Joos et al., in Proc. of SPIE 4611 (2002) 81-85, eds. Manns, Soederberg, and Ho. 12- F J Duarte (Ed.), Tunable Laser Applications,1st Ed. (Marcel-Dekker, New York,1995) Chapter 6. 13- "Efficiency and Plume Dynamics for Mid-IR Laser Ablation of Cornea". 2009-03-18. http://meetings.aps.org/link/baps.2009.mar.t27.6. Retrieved 2010-11-06. 14- "BBC health". BBC News. 2006-04-10. http://news.bbc.co.uk/1/hi/health/4895148.stm. Retrieved 2007-12-21. 15- "Dr Rox Anderson treatment". http://www.physorg.com/news63806610.html. Retrieved 2007-12- 21. 16- "Jefferson Lab FEL". http://www.jlab.org/fel/. Retrieved 2009-06-08. 17- "Airbourne megawatt class free-electron laser for defense and security". http://www.osti.gov/energycitations/product.biblio.jsp?osti_id=841301. Retrieved 2007-12-21. 18- "Raytheon Awarded Contract for Office of Naval Research's Free Electron Laser Program". http://news.prnewswire.com/viewcontent.aspx?acct=109&story=/www/story/06-09- 2009/0005040843&EDATE=. Retrieved 2009-06-12. 10

19- "Boeing Completes Preliminary Design of Free Electron Laser Weapon System". http://boeing.mediaroom.com/index.php?s=43&item=1126. Retrieved 2010-03-29. 20- "Breakthrough Laser Could Revolutionize Navy's Weaponry". Fox News. 2011-01-20. http://www.foxnews.com/scitech/2011/01/20/raygun-breakthrough-revolutionize-navalpower/?test=faces. Retrieved 2011-01-22. 11