Field Pro Operation and Installation Manual

Similar documents
SkyScan EWS-PRO - Manual -

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

CASSINI CQR-120 OPERATING INSTRUCTIONS

MET ONE RAIN GAGE MODELS 380, 385, 380M, 385M

Installation guide 862 MIT / MIR

AM 500A 500 WATT AM 1A 1 KILOWATT AM BROADCAST TRANSMITTERS. October, 1999 IM No

IF YOU NEED ANY FURTHER HELP WITH YOUR GALILEO TELESCOPE PLEASE CALL MON-FRI 9AM - 5PM E.S.COM

MKIII -MB USER S GUIDE 09/18/18. Rev. 3

PTA-427 BAROMETRIC PRESSURE TRANSDUCER OPERATOR S MANUAL

INSTRUCTIONS FOR ATTACHING THE NORDIC PLOW TO THE ACTION TRACKCHAIR

Small Absolute Pressure Sensor

QUICK SET UP MANUAL WEATHER CENTER

Small Gage Pressure Sensor

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

SK Series BOX PLOW INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS

A.R.M. 52 PLOW With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER BLACK MODEL NUMBER GRAY. Owner s Manual

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

Small, Gauge Pressure Sensor

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

Operating Instructions for Digital Manometer. Model: MAN-SD

Low Pressure Sensor Amplified Analog Output SM6295-BCM-S

FOR POLARIS ATV s P/N ASSEMBLY / OWNERS MANUAL

PUSH TUBE STANDARD DUTY

MODEL 107 TEMPERATURE PROBE INSTRUCTION MANUAL

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

FOR CAN-AM ATV s P/N ASSEMBLY / OWNERS MANUAL

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

FIELD GUIDE FOR HORUS SCOPES

Training Guide. Coastal Environmental Systems, Inc.

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

POWER PUSHER Snowplow

RAYTECH USA, Inc. 90C Randall Avenue, Woodlyn, PA USA Tel Fax Instruction Manual

INSTALLATION INSTRUCTIONS FRONT PLOW MOUNT KIT Part Number: Application: Polaris Sportsman 400, 500, 800

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

MODEL H3022 MAGNETIC BASE / DIAL INDICATOR / CALIPER COMBO OWNER'S MANUAL

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

A.R.M. 52 POLY PLOW BLACK With QUICK ATTACH MOUNTING SYSTEM MODEL NUMBER Owner s Manual

CR10XTCR THERMOCOUPLE REFERENCE

LDR Series BOX PLOW INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS

NEVER USE A TELESCOPE TO LOOK AT THE SUN DIRECTLY!

WHEN BRIGHTNESS COUNTS

WEATHERPAK TRx Training Guide

LIGHTNING SAFETY #24 CONSTRUCTION SAFETY EDUCATION PROGRAM

RP-200 TELESCOPE Instruction Manual

CAUTION: BEFORE INSTALLATION, CONFIRM THAT THE CROSSBOW IS UNLOADED AND IS IN SAFE OPERATING CONDITION.

LT8-300LTU Owner s Guide

WARRANTY AND ASSISTANCE

WeatherHub2 Quick Start Guide

Lamp and Control Panel (Lamp Panel)

Commercial Generator Parts Catalog. PROTEC Series

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Temperature Profile for 36 Marker Spheres on 3M 788 ACCR Conductor 3M Company

Jumbo Cross Beam Ionizer

Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C

DRIFTER PLOW-IN-A-BOX

PLOW MOUNT KIT FOR YAMAHA VIKING P/N ASSEMBLY / OWNERS MANUAL. Application PLOW PUSH FRAME NO or

ATV WP2 FRONT MOUNT PUSH TUBE

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

LUDLUM MODEL 42-5 NEUTRON BALL CART. August 2015 Serial Number PR and Succeeding Serial Numbers

For Customer Service, Rev A - 6/ OF 6

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

WS-7211U Wireless 433 MHz Weather Station. Instruction Manual

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

Assembly and Operation Manual. April 2016

CR10TCR THERMOCOUPLE REFERENCE

OASIS WIRELESS WEATHER STATION

QUANTUM CONCEPT. Swimming User s Manual

product manual H-4204 Proving Ring Penetrometer

TB-2012M BAROMETRIC PRESSURE SENSOR USER S MANUAL

Medium Pressure Sensor Analog Output

WT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual

Installation and Operation Manual. AllSync Plus Wired Clocks

INSTALLATION INSTRUCTIONS ProVantage Plow Pulley Part Number: 84526

OEM Silicon Pressure Die

Red and Green Dot Sight FF26002 USER MANUAL

CR10XTCR THERMOCOUPLE REFERENCE

Integrated Suppression Module

Since Mechanical Clocks Barometers. Owner s Manual

1 YEAR LIMITED WARRANTY TELESCOPES

One-Year Limited Warranty

WARRANTY AND ASSISTANCE

User s Manual: MODEL 904-T CLINOMETER PAK

Quick Start Guide. The ieq30 Pro GoTo German Equatorial Mount #3000E

1450 First Ave. Page 1 of 10 Chippewa Falls, WI (800) or (715) Fax: (715)

Power Resistor for Mounting onto a Heatsink Thick Film Technology

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

FOREMAN ASSEMBLY / OWNER S MANUAL

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

product manual H-3220A Benkelman Beam

6.Ebz!boe!8.Ebz!!! Gpsfdbtufst!!! G U I D E n catio Lo

50 Gordon Drive, Rockland, Maine sherplows.com. STORM BOXX Snowplow. 10' and 12' Box Plow for Backhoe Loaders

TORNADO PREPAREDNESS AND INFORMATION MANUAL

Quick Start Guide. For SmartEQ TM Pro+ (#3200) Portable German Equatorial GOTO Mount

ASSEMBLY / OWNER S MANUAL

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

Transcription:

Field Pro Operation and Installation Manual Xtreme Research Corporation SkyScan Division P.O. Box 336, Port Richey, FL 34673-0336 1-800-732-0665

Table of Contents 1. Installation 3 2. Operation 5 3. Care and Maintenance 6 4. Warranty / Service 8 5. Troubleshooting 8 6. Specifications 9

1. Installation AC power installation Remove the two screws and open the swing door. Run 3/4 conduit and wiring to the compression Fitting on the Control Enclosure. The AC adaptor in the Control Enclosure is a two pin isolated adaptor and does not require a ground connection. Connect the neutral (white) wire to the connector with the white wire already attached. Connect the hot line (black) to the connector with the black wire. Cap off the ground (green) wire with the wire nut supplied. During operation should the unit lose power, the internal backup battery will power the unit for up to one hour. This battery is charged during normal operation. The system should be hooked to the AC power source for an hour before operation to fully charge the battery. compression fitting swing door 2 screws 10-32 x 1/4

Interface Cables There are two cables, each 10 long. The cable with the 8 pin connector connects the Control Enclosure to the Display Enclosure. Be sure to turn the locking collar tight after installing to insure a solid connection. The cable with the 4 pin connector connects the Display to the Horn assembly. Different cable lengths can be specially ordered by contacting Xtreme Research. locking collar Mounting Brackets It is important that the Display Enclosure not be mounted directly against a metal object. The display enclosure may be mounted using two methods. The preferable method is to use the supplied flange on the back of the enclosure connecting it via a pipe to another structure. The other way is to use the four mounting tabs against a sutable surface. The height of the display should be such that all affected persons can easily see it (usually 8 to 10 high). The cover should be locked to protect from any unauthorized access. The control enclosure may be mounted any place that is convenient. Longer cables may be ordered as an option. The horn must be mounted at least 5 feet from the display enclosure so as to not interfere with the operation. There are four tabs on the back of the housing that may be used for mounting.

2. Operation Theory of Operation: Field Pro detects the characteristic electromagnetic emissions from individual lightning strikes and uses patented technology to determine the distance to the detected strike. The distances are indicated in four ranges: 0-3 miles; 3-8 miles; 8-20 miles and 20-40 miles. This allows you to track the approach of dangerous storm activity. When installation is complete you can operate the unit via the On/Off switch in the Control Enclosure. The indicators will cycle once. A blinking green LED will indicate that the unit is set properly. The Horn switch should be off at this time. Wait 3 sec. for the system to do a self check and all of the LEDs have stopped blinking (except for the on/off LED), then turn the horns on. Turning the horns off does not disable the normal operation. The blinking green horn LED indicates that the horn/siren is activated. The Range switch allows you to choose the distance at which detected lightning strokes will triggert the siren. To activate the Range distance, press the switch repeatly until the desired range category indicator is on. wait for 3 seconds and this range will be entered in the computer. To change the range repeat this process.

Facts about Lightning and Thunderstorms Thunderstorms and the associated lighting cause an average of 200 deaths and many more injuries in the U.S. every year. Most of these deaths and injuries could be prevented by the warning provided by Field Pro. The average lightning strike is 5-6 miles long A lightning strike is incredibly powerful; up to 30 million volts at 100,000 amps flow in less than 1/10 of a second. The average thunderstorm is 6-10 miles wide and moves at a rate of 25 miles per hour. Once the leading edge of a thunderstorm approaches to within 10 miles, you are at immediate risk due to the possibility of lightning strikes coming from the storm s overhanging anvil cloud. This is the reason many lightning deaths and injuries occur with clear skies overhead. On average, the thunder from a lightning strike can only be heard over a distance of 3-4 miles, depending on the terrain, humidity and background noise around you. By the time you can hear the thunder, the storm has already approached to within 3-4 miles. The sudden cold wind that many people use to gauge the approach of a thunderstorm is the result of down drafts and usually extends less than 3 miles from the storm s leading edge. By the time you feel the wind, the storm can be less than 3 miles away. Approximately 100,000 thunderstorms occur in the U.S. each year. About 10% of all thunderstorms are severe enough to produce high winds, flash floods and tornadoes. IMPORTANT There are two types of lightning produced by a thunderstorm, cloud-to-ground and cloud-to-cloud. For any user on the ground, the cloud-to-ground is the most dangerous. The Field Pro is designed to detect cloud-to-ground lightning strikes. While it may detect cloudto-cloud lightning strikes, there may be occasions where storms will produce cloud-to-cloud lightning strikes that are not detected by the Field Pro. User should therefore still exercise extreme caution when exposed to lightning storms.

3. Care and Maintenance The Field Pro has been manufactured of the highest quality materials and components. It should provide you with years of service with minimum maintenance. A few important tips will maximize the operational life of your Field Pro. The Field Pro is weather-resistant not waterproof. Your Field Pro should never be immersed in water. The Field Pro is a sensitive electronic instrument and should never be dropped or subjected to high impact forces. Your Field Pro contains no user serviceable parts and is not intended to be opened. Opening the case will void the Product Warranty. 4. Warranty, Service and Support Warranty Xtreme Research corporation, SkyScan Division, P.O.Box 336, Port Richey, FL 34673-0336 agrees to repair or replace this product for one year from the original date of purchase absolutely free. This warranty does not include any physical damage to the unit or any of its accessory items and does not cover damage to the Field Pro unit resulting from the use of accessories not manufactured or authorized for use by Field Pro. Any modifications or repairs by unauthorized service personnel will void this warranty. You are responsible for all shipping charges to Xtreme Research. Xtreme Research will pay for ground UPS back to the customer. NO OTHER EXPRESS WARRANTY HAS BEEN MADE OR WILL BE MADE WITH RESPECT TO THE UNIT AND NO PERSON IS AUTHORIZED TO PROVIDE ANY OTHER WARRANTY IN CONNECTION WITH THE SALE OF OUR PRODUCTS BEYOND THE DESCRIPTION ON THE FACE HEREOF. IM- PLIED WARRANTIES, INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE. XTREME RESEARCH CORP. RESERVES THE RIGHT TO PERFORM MODIFICATIONS OR IMPROVE- MENTS ON ITS PRODUCTS WITHOUT INCURRING THE OBLIGATION TO INSTALL THE CHANGES ON UNITS PREVIOUSLY SOLD, DELIVERED OR SERVICED. SOME STATES DO NOT ALLOW LIMI- TATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. XTREME RESEARCH CORP S LIABILITY SHALL BE LIMITED TO THE COST OF REPAIR OR REPLACEMENT OF THE UNIT AND XTREME RESEARCH CORP. SHALL IN NO EVENT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.

Service This Service Policy is valid in the United States only. This applies to Field Pro units returned to our factory in Arvada, CO and is subject to change without notice. Field Pro reserves the right to deem any product unserviceable when replacement parts are no longer reasonably available. After the original warranty period, a standard service charge will be assessed for each repair (physical damage and missing parts are not included). Please call our Customer Support Department to verify the service charge for you unit. The standard service charge includes UPS Gnd. or Parcel Post freight only. If charges are not prepaid, the unit will be returned C.O.D. Repairs are warranted for ninety (90) days. Return units for repair to Orion Engineering, Inc. 6626 W. 79th Ave. Arvada, CO 80003 5. Troubleshooting The unit may be tested by placing it near a high voltage source, i.e. the back of an operating CRT (approximately 30K volts). A one foot separation should be sufficient. A small stun gun may also be used with a one to one and a half foot separation from the unit. A wait time of 10 seconds after turn on is necessary before initiating a high voltage signal. A wait time of 45 seconds is necessary between successive tests. If the unit fails to alarm, turn it off, restart, wait the appropriate time, then retry. If the unit fails to start, call the factory for further information.

6. Specifications Microprocessor controlled Patented dual antenna technology 4 detection zones 0 to 3 miles 3 to 8 miles 8 to 20 miles 20 to 40 miles Separate control and display enclosures with 10 interface cables. Horns - 120 db Custom length interface cables available (call for a quote)