The Accuracy of Electronic Distance Meters over Short Distances

Similar documents
Implementation of a high-accuracy spatial network for measurements of steel constructions

Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO Second edition

UNCERTAINTY IN TACHEOMETRIC MEASUREMENT OF CONVERGENCES IN TUNNELS

INTRODUCTION TO ENGINEERING SURVEYING (CE 1305)

Determination of Angular Standard Deviation with Total Stations

Springer Berlin Heidelberg New York Barcelona Budapest Hong Kong London Milan Paris Santa Clara Singapore Tokyo

Observation of Landslide Movements by Geodetic and Borehole Tilt Measurements

Efficient Local Deformation Recognition on Highway Bridges

DETERMINATION OF AIR REFRACTION INFLUENCE ON TRIGONOMETRIC HEIGHT DIFFERENCES

available online at H. Sirůčková

Analysis of the variations of measured values in continuous long-term geodetic monitoring

Surveying Prof. Bharat Lohani Department of Civil Engineering Indian Institute of Technology, Kanpur. Module - 3 Lecture - 4 Linear Measurements

Final Report August 2010

Part 5: Total stations

Applied Terrestrial Laser Scanner in active volcano crater: correction to velocity and geometry

GRAVITY MEASUREMENTS IN THE GEODYNAMIC NETWORK SUDETY

The elimination of vertical refraction in trigonometric measurements of height differences

Estimation of the Gauging and the Calibration Time Interval for the Modern Total Stations

A COMPARISON OF TWO WEATHER DATA ACQUISITION METHODS FOR THE CALIBRATION OF THE PTB GEODETIC BASELINE

CALIBRATION OF SURVEYING INSTRUMENTS AND TOOLS MEANS TO THE QUALITY INCREASE OF DEFORMATION MEASUREMENTS

Warkworth Observatory Local Tie Survey

Chapter-2 Direct Measurement Indirect Measurement Method of linear measurement Taping corrections Optical measurement Tachometry EDM Measurement

Geodetic Works during the Estimation of the Vertical Displacement of a Bridge under a Load Test

Testing DistoX Device for Measuring in the Unfavourable Conditions

CIVIL ENGINEERING AND BUILDING SERVICE TOPOGRAPHIC PERMANENT LANDMARKS NETWORK. SPATIAL COORDINATE OPTIMIZATION

ENVIRONMENTAL ENGINEERING

MONITORING OF THE WUT GRAND HALL ROOF IN CONDITIONS OF HIGH TEMPERATURE CHANGES

Rigorous Combination of Superconducting and Absolute Gravity Measurements with Respect to Instrumental Properties

TOPOGRAPHIC MONITORING OF A WATER TANK IN THE WIDENING WORKS OF EIXO NORTE-SUL HIGHWAY IN LISBON

MEASUREMENT OF AC VOLTAGES WITH DIGITAL VOLTMETERS

PRIMARY CONTROL SURVEYS

Србија DETERMINING TEMPERATURE DEPENDENCE OF COLLIMATION ERROR OF DIGITAL LEVEL LEICA DNA 03. Jelena GUČEVIĆ, Siniša DELČEV, Vukan OGRIZOVIĆ

COPYRIGHTED MATERIAL INTRODUCTION CHAPTER 1

P1.3 EVALUATION OF WINTER WEATHER CONDITIONS FROM THE WINTER ROAD MAINTENANCE POINT OF VIEW PRINCIPLES AND EXPERIENCES

The final publication is available at

Islamic University of Gaza Civil Engineering Department Surveying II ECIV 2332

Interactive system for the interpretation of atomic spectra

Meeting the ODOT Survey & Mapping Specifications

Overview. Calibration Bench. Research topic & Error Sources. Methodology. Results. Future Research. Conclusion

VIBRATION ANALYSIS AND REPAIR PROCESS FOR THE VENTILATION SYSTEM FOR SMOKE DRAIN IN THE THERMAL POWER PLANT

Influence of the Incidence Angle on the Reflectorless Distance Measurement in Close Range

INSTRUMENTATION AND SURVEY NETWORKS AT THE ESRF

Available online at ScienceDirect. Andrej Godina*, Bojan Acko

Week 02. Assist. Prof. Dr. Himmet KARAMAN

COPYRIGHTED MATERIAL INTRODUCTION CHAPTER 1

GPS cycle slips detection and repair through various signal combinations

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

The 2008 Local-tie Survey at the Onsala Space Observatory

Geometric Reduction of Distances. John Hamilton Terrasurv

CE6404 SURVEYING II. 3. Arbitrary Bench Mark: When the RL of some fixed Points are assumed, they are termed a arbitrary Bench mark

The 2007 Tidbinbilla Local Tie Survey

GEOMATICS ENGINEERING

Utility of Geodetic Refraction

INTERNATIONAL STANDARD

Analysis of the Accuracy of GMF, NMF, and VMF1 Mapping Functions with GPT 50 a Priori Zenith Constraint in Tropospheric Delay Modelling

HORIZONTAL PROJECTION PARAMETERS: DANE COUNTY COORDINATES

PREDICTION OF THE OUTPUT VOLTAGE OF DC VOLTAGE STANDARDS

POSITIONING THE SPRING-8 MAGNETS WITH THE LASER TRACKER

ACCURACY OF WALL STATION SURVEYS

Study of DC Cylindrical Magnetron by Langmuir Probe

Practice Questions - Revision

ESTIMATING THE RESIDUAL TROPOSPHERIC DELAY FOR AIRBORNE DIFFERENTIAL GPS POSITIONING (A SUMMARY)

Modelling and Experimental Validation Possibilities of Heat Transfer Room Model

Estimation of wooden coefficient of expansion due to temperature and moisture with geodetic sensors

AUTOMATIC MEASUREMENT OF ICING ON THE WEST OF THE CZECH REPUBLIC

Carrier-phase Ambiguity Success Rates for Integrated GPS-Galileo Satellite Navigation

Progress Report on the WLRS: Getting ready for GGOS, LLR and Time Transfer

HISTORICAL PLASTER COMPOSITION DETECTION USING REFLECTANCE SPECTROSCOPY

USAGE OF OLD MAPS AND THEIR DISTRIBUTION WITHIN THE FRAME OF WEB MAP SERVICES

POSITIONING OF THE ELECTRODE MODULES OF THE KATRIN EXPERIMENT BY USING A LASER TRACKER

Kinematic Monitoring for Baselines Ranging from 3m to 30km

Formulation of L 1 Norm Minimization in Gauss-Markov Models

SAR interferometry Status and future directions. Rüdiger Gens

ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES

Statistical characteristics of L1 carrier phase observations from four low-cost GPS receivers

DETAILED ANALYSIS OF THE MÜLLER S MAP OF BOHEMIA

CHENDU COLLEGE OF ENGINEERING & TECHNOLOGY DEPARTMENT OF CIVIL ENGINEERING SUB CODE & SUB NAME : CE6404 SURVEYING II

Leveling. 3.1 Definitions

Surveying the Old Underground Mine Works Using Innovative Techniques

The Victorian Seismic Zone 2011 GNSS Campaign Data Analysis

Leica TPS1200 GeoCOM Getting Started Manual

Monitoring and Analyzing Movements of Geodetic Monuments

BUREAU INTERNATIONAL DES POIDS ET MESURES

CHARA Collaboration Year-Eight Science Review. VLTI update. F. Delplancke

CIV : THEODOLITE ADJUSTMENT

Acta Universitatis Carolinae. Mathematica et Physica

Development of the Czech National Geodetic Control

ITTC Recommended Procedures and Guidelines

Updating and Re-establishment of Cadastral Control Points in Korea by Using GPS Observations

Relative Positional Precision Explained in Everyday Language. Measurement vs. Enumeration. ALTA / ACSM Standards and Kentucky Standards of Practice

TOWARDS ROBUST LOCALIZATION OF RTK-GPS TOPOGRAPHIC SURVEYS 23

Europass Curriculum Vitae

PROFESSOR LAZZARINI S CONCEPTS IN DISPLACEMENT MEASUREMENTS AND ANALYSIS STILL VALID AND INSPIRING

Achievement Standard (Physics 2.1)

S U R V E Y I N G. Lecture Notes. Draft

Chapter 2. Theory of Errors and Basic Adjustment Principles

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Dr. Jean Lautier-Gaud October, 14 th 2016

Application of the Kalman Filtering in Terrestrial Geodesy

Mutual comparison of the combinations of the Earth orientation parameters obtained by different techniques

Transcription:

263 The Accuracy of Electronic Distance Meters over Short Distances Braun, J., Štroner, M. and Urban, R. Czech Technical University in Prague, Faculty of Civil Engineering, Department of Special Geodesy, Thákurova 7, 16629 Praha 6, Czech Republic, Web site: www.fsv.cvut.cz E-mail: jaroslav.braun@fsv.cvut.cz, martin.stroner@fsv.cvut.cz, rudolf.urban@fsv.cvut.cz Abstract The paper deals with testing of electronic distance meters on absolute baseline with forced centrings. The sizes of systematic and random errors and their time changes are determined by experimental measurements. The accuracy of distance meters is determined for short lengths up to 38 m which are common in surveying for purposes of mechanical engineering. Key words: Absolute lengths, baseline, random errors, systematic errors, stability of EDM. 1 INTRODUCTION In order to increase the accuracy of geodetic measurements, the effect of instrument errors is reduced by a suitable procedure of the measurement and measurement configuration or calculation corrections can be applied on the measured values. Constant corrections or corrections depending on measured distance can be used to correct distance measured by the EDMs (Electronic Distance Meters) of the total stations. Baselines are used to determine the distance meters errors. Manufacturers give the standard deviation of the measured distance in form: A B D. (1) D According to (Rüeger, 1990), the symbol A is in millimetres and includes phase resolution of EDM instrument, maximum amplitude (or average effect) of short periodic (cyclic) error of phase distance meters, maximum (or average) effect of non-linear distance dependent errors and accuracy of an additive constant (compatibility of reflectors). The symbol B is in ppm (part per million) and includes the range of the typical frequency drift of the main oscillator within the specified temperature range and the maximum error which may be caused by the limited step interval of the ppm dial. This list is a mix of systematic and random errors. Besides these effects accuracy of the distance measurement is also influenced by surveyor, the atmosphere and usage of other equipment. Summary of all these effects leads to the error model according to (Staige, 2007): error TS 8 Metrology, testing and calibration systematic errors random errors noise. budget (2) Procedures for testing of the EDMs used in the precise industrial measurement were designed at the Department of Special Geodesy. The aim of the tests is to determine the size of systematic and random errors for short lengths (up to 40 m), which are commonly INGEO 2014 6 th International Conference on Engineering Surveying Prague, Czech republic, April 3-4, 2014

264 INGEO 2014 measured in indoor industrial applications. Determination of the properties of EDMs leads to the use of real standard deviations in the analysis of the accuracy, more accurate measurements and greater reliability of results. This paper focuses on the initial tests of selected EDMs, i.e. tests of repeatability of the measurement of the same absolute distance and the temporal stability of errors of EDMs. 2 EDM BASELINE Baseline in the laboratory of geodesy at the Faculty of Civil Engineering CTU in Prague is used for testing of EDMs. The baseline is made up of 16 concrete pillars with forced centring and its total length is 38.6 m. Pillars are mutually spaced at a distance of 0.9 m - 5.0 m (average 2.5 m). Directly measured distances are compared with absolute distances between pillars to test EDMs. The distances between pillars were determined (for used equipment) using Leica Absolute Tracker AT401 (borrowed from the Research Institute of Geodesy, Topography and Cartography, VUGTK). The standard deviation of distances between pillars is 0.02 mm. In this measurement additive prism constant was also determined, which is defined into the instrument during the test measurements. Two tribrachs are used for the tests on the baseline (one for the instrument, one for the carrier with prism). Tribrachs are tightened on pillars in the same way every time (indicated by line marks) to avoid the influence of their eccentricity error. The tribrachs have one screw glued to ensure the consistently high placement of the prism. Another used equipment in calibration process is precision carrier GZR3 Leica and Leica mini prism GMP101. To eliminate the influence of the eccentricity the carrier is rotated always in the same way (eyepiece in the direction to the first pillar). 3 TESTING PROCEDURE The EDM measurement repeatability and stability over time are important for determining the size of errors and corrections calculation. The first tests were designed to confirm these requirements. The tests are based on measuring of the distance between the first pillar and all other pillars (15 lengths) and comparing the results to the nominal values. Distance differences were plotted to the graphs (Fig. 2 Fig. 7). Time interval was chosen to be from one to two weeks between the first and the second measurement and one to one and half month between the second and the next measurement. Results from the first three tests of all instruments are presented in this paper. Instruments were used for common geodetic activities between tests. During the tests are registered slope distances with resolution of 0.1 mm and zenith angles, measurement is performed in both faces, to speed up the process the whole first face measurement is realized at first and then the whole second face measurement. Targeting is not changed during the measurement in one face. This procedure allows evaluating the properties of the EDM in each face and also the average of both faces. Temperature and atmospheric pressure are measured in the half of the measured distance and are used to calculate the physical corrections (by the instrument s software). 3.1 NUMBER OF REPEATS The number n of repeated measurement of distance is determined by considering the value of the standard deviation of the standard deviation of the measured distance d (Štroner, 2011) given by formula

Braun, J. et al.: The accuracy of electronic distance meters over short distances 265 d (3) 2 1 n, where is standard deviation of the distance. Considering the selected condition that standard deviation d can be maximally 10% of standard deviation is the size of the random selection (number of the measurements) given by the formula d 0.1 n 51. (4) 2 n 1 For each tested EDM and one distance were measured 102 observations (51 in each face), which together give the mean value. This average value is characterized by the sample standard deviation s which is given by the formula 2n 2 d d i, 1 s 2 n 1 (5) i1 where d is the average distance (from all measurements in both faces) and d i is i-th measured distance. 4 TESTED INSTRUMENTS For initial tests were chosen instruments from the property of the Department of Special Geodesy, Faculty of Civil Engineering CTU in Prague, commonly used for precise measurements in engineering surveying (Fig. 1). These are one instrument Trimble S6 HP ( D = 1 + 1 ppm D, phase EDM), two instruments Topcon GPT7501 ( D = 2 + 2 ppm D, pulse EDM) and two instruments Leica TC1202 ( D = 2 + 2 ppm D, phase EDM). Both instruments Leica and Topcon are from the same production series (difference in serial numbers is 4 and 1), those were selected to find out if the instruments from one production series have or have not the same properties. If not, correction has to be determined for each instrument separately. Figure 1 Trimble S6 HP, Topcon GPT-7501 and Leica TC1202 total stations 5 RESULTS OF THE TESTS Each instrument was tested in three epochs. Fig. 2 shows that Trimble S6 HP s results differ maximally 0.4 mm between epochs. It shows good repeatability of the measured distance and stability over time. Distance to the pillar 2 differs by 2 mm. This was probably caused by the short distance (1.36 m) with difficult targeting or more probably by the blunder of the operator during the target placing. The resulting difference from the nominal distances influences mainly the additive constant and cyclic error. From a distance of 10 m and further

266 INGEO 2014 has the Trimble S6 EDM approximately constant error 0.5 mm compared to the nominal distances of the baseline. Sample standard deviations ranged in the interval of 0.26 mm - 0.36 mm. Figure 2 Difference of the measured and nominal distances Trimble S6 HP (S. No. 92120086) Figure 3 Difference of the measured and nominal distances Topcon GPT7501 (S. No.7W1318) Results of Topcon GPT7501 instruments testing are plotted in the Fig. 3 and Fig. 4. There can be seen that the results of the single epochs differ maximally in 0.5 mm. Both instruments showed good repeatability of the measured distance and stability over time. Both instruments show an increase in errors in the range of 0 m - 10 m and significant changes in the interval of 15 m - 25 m. In this interval can be seen for EDMs in these product line typical problems with measuring distances that have been identified previously in various experimental measurements. The graphs also show that although it is the same instrument (difference of the production numbers is 1) EDMs have the different deviations from the nominal distances. Deviations of the instrument 7W1318 range in the interval between 0.0

Braun, J. et al.: The accuracy of electronic distance meters over short distances 267 mm - 2.0 mm and of instrument 7W1317 in range of 1.5 mm - 3.0 mm. Sample standard deviations range in interval of 0.20 mm - 0.47 mm. Figure 4 Difference of the measured and nominal distances Topcon GPT7501 (S. No.7W1317) Results of Leica TC1202 instruments testing are plotted in the Fig. 5 and Fig. 6. There can be seen that the measured distances correspond with the maximum difference of 0.2 mm with nominal ones. Both instruments showed good repeatability of the measured distance and stability over time. In the Fig. 5 can be seen the solitary difference against two others of the measured distance at the pillar 4 in the second epoch, possibly the blunder of the operator again. The graphs also show that although it is the same instrument production (the difference of serial numbers is 4) EDMs show different values of deviations from the nominal distances. Sample standard deviations ranged in the interval of 0.09 mm - 0.17 mm. Figure 5 Difference of the measured and nominal distances Leica TC1202 (S. No. 228137) All the EDMs showed significant changes in deviations on the first 10 meters of the baseline. These changes correspond to assumptions of the changes of the addition constant on the very short distances (Staige, 2007). All graphs were complemented by the polynomial (fifth degree) function fitted to the mean differences, which express the deviation of the measured lengths from the correct (true) values. These polynomials will be further

268 INGEO 2014 investigated and the possibility of interpolation of the corrections from the polynomial will be tested. Figure 6 Difference of the measured and nominal distances Leica TC1202 (S. No. 228133) 6 CONCLUSION Tests of repeated measurements on EDM baseline with accurate absolute lengths were designed for determining the sizes of systematic and random errors of EDMs used in indoor industrial measurements. Tests have shown that the commonly used instruments have good repeatability and stability behaviour of EDM in time. The result is also that each instrument behaves uniquely and cannot fully generalize the behaviour of one production series. Next tests will concentrate on more detailed mapping of the measurement errors on the short distances with much shorter step and also on creating of the numerical correction procedures. ACKNOWLEDGMENT The article was written with support from the internal grant No. SGS13/059/OHK1/1T/11 Optimization of the acquisition and processing of 3D data for the needs of engineering surveying. REFERENCES RÜEGER, J. M. (1990) Electronic Distance Measurement. 3. ed. Heidelberg: Springer- Verlag, 266 pp. ISBN 3-540-51523-2. STAIGER, R. (2007). Recommended Procedures fot Routine Checks of Electro-Optical Distance Meters. FIG. 14 pp. Available: http://www.fig.net/pub/figpub/pub09/fig- Publication_Nr9_english.pdf ŠTRONER, M., HAMPACHER, M. (2011). Zpracování a analýza mení v inženýrské geodézii (Processing and Analysis of Measurements in Engineering Surveying). 1 st edition. Prague: CTU Publishing House. 313 pp., ISBN 978-80-01-04900-6.