Flow measurements in the Scrape-Off Layer of Alcator C-Mod using Impurity Plumes

Similar documents
A novel tracer-gas injection system for scrape-off layer impurity transport and screening experiments

Drift-Driven and Transport-Driven Plasma Flow Components in the Alcator C-Mod Boundary Layer

Blob sizes and velocities in the Alcator C-Mod scrapeoff

Alcator C-Mod. Particle Transport in the Alcator C-Mod Scrape-off Layer

Helium-3 transport experiments in the scrape-off layer with the Alcator C-Mod omegatron ion mass spectrometer

GA A26119 MEASUREMENTS AND SIMULATIONS OF SCRAPE-OFF LAYER FLOWS IN THE DIII-D TOKAMAK

Alcator C-Mod. Particle Transport in the Scrape-off Layer and Relationship to Discharge Density Limit in Alcator C-Mod

FAR SCRAPE-OFF LAYER AND NEAR WALL PLASMA STUDIES IN DIII D

Driving Mechanism of SOL Plasma Flow and Effects on the Divertor Performance in JT-60U

Density Limit and Cross-Field Edge Transport Scaling in Alcator C-Mod

Fluctuation statistics in the scrape-off layer of Alcator C-Mod

1 EX/P6-5 Analysis of Pedestal Characteristics in JT-60U H-mode Plasmas Based on Monte-Carlo Neutral Transport Simulation

Development of a New Gas Puff Imaging Diagnostic on the HL-2A Tokamak

Cross-field plasma transport and main chamber recycling in diverted plasmas on Alcator C-Mod. Abstract

Plasma Spectroscopy in ISTTOK

Plasma Fusion Center Massachusetts Institute of Technology Cambridge, MA Burrell, K.H. General Atomics PO Box San Diego, CA

Transport and drift-driven plasma flow components in the Alcator C-Mod boundary plasma

OVERVIEW OF THE ALCATOR C-MOD PROGRAM. IAEA-FEC November, 2004 Alcator Team Presented by Martin Greenwald MIT Plasma Science & Fusion Center

Total Flow Vector in the C-Mod SOL

Scaling of divertor heat flux profile widths in DIII-D

Local Plasma Parameters and H-Mode Threshold in Alcator C-Mod

Connections between Particle Transport and Turbulence Structures in the Edge and SOL of Alcator C-Mod

Direct drive by cyclotron heating can explain spontaneous rotation in tokamaks

Cross-Field Transport in the SOL: Its Relationship to Main Chamber and Divertor Neutral Control in Alcator C-Mod

Cross-Field Plasma Transport and Main Chamber Recycling in Diverted Plasmas on Alcator C-Mod

ONION-SKIN METHOD (OSM) ANALYSIS OF DIII D EDGE MEASUREMENTS

L-mode filament characteristics on MAST as a function of plasma current measured using visible imaging

Investigation of causes for the discrepancy between the measured and modeled helium emissions using a gas puff imaging diagnostic

Modelling of JT-60U Detached Divertor Plasma using SONIC code

Fusion Nuclear Science Facility (FNSF) Divertor Plans and Research Options

Experimental investigation of the parallel structure of fluctuations in the scrape-off layer of Alcator C-Mod

IMPLICATIONS OF WALL RECYCLING AND CARBON SOURCE LOCATIONS ON CORE PLASMA FUELING AND IMPURITY CONTENT IN DIII-D

Electrode and Limiter Biasing Experiments on the Tokamak ISTTOK

Some Notes on the Window Frame Method for Assessing the Magnitude and Nature of Plasma-Wall Contact

PSI meeting, Aachen Germany, May 2012

GA A23411 COMPARISON OF LANGMUIR PROBE AND THOMSON SCATTERING MEASUREMENTS IN DIII D

Effect ofe B driven transport on the deposition of carbon in the outer divertor of ASDEX Upgrade

Study of B +1, B +4 and B +5 impurity poloidal rotation in Alcator C-Mod plasmas for 0.75 ρ 1.0.

Simulation of ASDEX Upgrade Ohmic Plasmas for SOLPS Code Validation

Impurity accumulation in the main plasma and radiation processes in the divetor plasma of JT-60U

ARTICLES PLASMA DETACHMENT IN JET MARK I DIVERTOR EXPERIMENTS

Effect of Ion Orbit Loss on Rotation and the Radial Electric Field in the DIII-D Tokamak

Measurements of rotational transform due to noninductive toroidal current using motional Stark effect spectroscopy in the Large Helical Device

Rapid changes of turbulence propagation direction in the edge of

Formation of High-b ECH Plasma and Inward Particle Diffusion in RT-1

Progress of Confinement Physics Study in Compact Helical System

Partially Coherent Fluctuations in Novel High Confinement Regimes of a Tokamak

GA A26123 PARTICLE, HEAT, AND SHEATH POWER TRANSMISSION FACTOR PROFILES DURING ELM SUPPRESSION EXPERIMENTS ON DIII-D

High Speed Imaging of Edge Turbulence in NSTX

Observation of Neo-Classical Ion Pinch in the Electric Tokamak*

Power Balance and Scaling of the Radiated Power in the Divertor and Main Plasma of Alcator C-Mod

Bolometry. H. Kroegler Assciazione Euratom-ENEA sulla Fusione, Frascati (Italy)

Relating the L-H Power Threshold Scaling to Edge Turbulence Dynamics

GA A22863 PLASMA PRESSURE AND FLOWS DURING DIVERTOR DETACHMENT

Evidence for electromagnetic fluid drift turbulence controlling the edge plasma state in the Alcator C-Mod tokamak

Divertor Detachment on TCV

Impact of neutral atoms on plasma turbulence in the tokamak edge region

Simulation of Plasma Flow in the DIII-D Tokamak

ArbiTER studies of filamentary structures in the SOL of spherical tokamaks

DIVIMP simulation of W transport in the SOL of JET H-mode plasmas

Operational Phase Space of the Edge Plasma in Alcator C-Mod

A neoclassical model for toroidal rotation and the radial electric field in the edge pedestal. W. M. Stacey

Progress in characterization of the H-mode pedestal

EFFECT OF EDGE NEUTRAL SOUCE PROFILE ON H-MODE PEDESTAL HEIGHT AND ELM SIZE

Observations of Counter-Current Toroidal Rotation in Alcator C-Mod LHCD Plasmas

TH/P4-9. T. Takizuka 1), K. Shimizu 1), N. Hayashi 1), M. Hosokawa 2), M. Yagi 3)

Nuclear Fusion Energy Research at AUB Ghassan Antar. Physics Department American University of Beirut

L-to-H power threshold comparisons between NBI and RF heated plasmas in NSTX

Divertor Heat Flux Reduction and Detachment in NSTX

Reduction of Turbulence and Transport in the Alcator C-Mod Tokamak by Dilution of Deuterium Ions with Nitrogen and Neon Injection

Effect of ExB Driven Transport on the Deposition of Carbon in the Outer Divertor of. ASDEX Upgrade

Plasma Science and Fusion Center

Current Drive Experiments in the Helicity Injected Torus (HIT II)

Comments on Particle and Energy Balance in the Edge Plasma of Alcator C-Mod

Tokamak Divertor System Concept and the Design for ITER. Chris Stoafer April 14, 2011

Impurity transport analysis & preparation of W injection experiments on KSTAR

EXD/P3-13. Dependences of the divertor and midplane heat flux widths in NSTX

Physics of the detached radiative divertor regime in DIII-D

Current Drive Experiments in the HIT-II Spherical Tokamak

arxiv: v1 [physics.plasm-ph] 14 Jul 2014

Development of a High-Speed VUV Camera System for 2-Dimensional Imaging of Edge Turbulent Structure in the LHD

Lower Hybrid Wave Induced Rotation on Alcator C-Mod* Ron Parker, Yuri Podpaly, John Rice, Andréa Schmidt

Measurement of lower hybrid waves using microwave scattering technique in Alcator C-Mod

Effect of divertor nitrogen seeding on the power exhaust channel width in Alcator C-Mod

3D analysis of impurity transport and radiation for ITER limiter start-up configurations

Divertor physics research on Alcator C-Mod. B. Lipschultz, B. LaBombard, J.L. Terry, C. Boswell, I.H. Hutchinson

Triggering Mechanisms for Transport Barriers

ICRF Loading Studies on Alcator C-Mod

Contents: 1) IEC and Helicon 2) What is HIIPER? 3) Analysis of Helicon 4) Coupling of the Helicon and the IEC 5) Conclusions 6) Acknowledgments

Fusion Development Facility (FDF) Divertor Plans and Research Options

Highlights from (3D) Modeling of Tokamak Disruptions

Erosion and Confinement of Tungsten in ASDEX Upgrade

Spontaneous Core Toroidal Rotation in Alcator C- Mod L-Mode, H-Mode and ITB Plasmas.

UPGRADED CALIBRATIONS OF THE THOMSON SYSTEM AT DIII D

Integrated Simulation of ELM Energy Loss Determined by Pedestal MHD and SOL Transport

Scaling of divertor heat flux profile widths in DIII-D

Modelling of prompt deposition of tungsten under fusion relevant conditions

Additional Heating Experiments of FRC Plasma

Effects of q(r) on the Alpha Particle Ripple Loss in TFTR

EFDA European Fusion Development Agreement - Close Support Unit - Garching

Transcription:

Flow measurements in the Scrape-Off Layer of Alcator C-Mod using Impurity Plumes S. Gangadhara,. Laombard M.I.T. Plasma Science and Fusion Center, 175 Albany St., Cambridge, MA 2139 USA Abstract Accurate measurements of plasma flows in the scrape-off layer (SOL) are a necessary requirement for understanding the physics of tokamak edge plasmas. A system is being developed on Alcator C-Mod for inferring flows parallel (v ) and perpendicular (v E ) to local magnetic field lines from impurity emission patterns ( plumes ) generated by local gas injection. Carbon plumes are generated at variable location in the SOL by puffing deuterated ethylene gas (C 2 D 4 ) through the end of a reciprocating fast-scanning probe. Two intensified CCD cameras are used to record C +1 and C +2 emission patterns simultaneously from near-perpendicular views. Plumes are modeled using a Monte Carlo impurity transport code, from which values for the background flows may be extracted. The sensitivity of the plume structure is investigated for a number of code inputs, including radial electric field (E r ) and the neutral launch dynamics. Initial modeling results indicate discrepancies between values of v and E r extracted from the plumes and measurements obtained from probe data. Key words: Alcator C-Mod; Scrape-Off Layer Flows; Plumes. 1 Introduction Flows parallel and perpendicular to local magnetic field lines play an important role in tokamak edge plasmas. Accurate measurements of flows in the scrape-off layer (SOL) are therefore desired. On Alcator C-Mod, reciprocating fast-scanning probes are typically used to make measurements of parallel flows (v ) and radial electric fields (E r ) in the SOL. Interesting conclusions about edge plasma physics result from the interpretation of these measurements. For example, recent results [1] indicate that over much of the SOL cross-field transport to the main-chamber walls dominates over parallel transport to the divertor, a result based in part on the measurement of low parallel flow velocities in the SOL. Reversed flows, or flows away from the divertor, are also 1

measured near the separatrix of most C-Mod discharges [2]. Depending on the magnitudes of v and E r, impurities generated near divertor surfaces may be transported into the main-chamber SOL, providing a mechanism of enhancing impurity concentrations in the core plasma. An independent measurement of SOL flows is available by viewing impurity emission patterns ( plumes ) generated by localized injection of gas into the edge plasma. A system has been developed on Alcator C-Mod to inject impurity gas at variable position in the SOL, up to the separatrix, via a reciprocating fast-scanning probe [3]. Plasma flows are inferred from modeling the resulting impurity emission plumes, imaged from two near-perpendicular views. Measurements of the local electron density and temperature are also provided by the probe, and are used in plume modeling. In this paper, we report initial results and progress towards developing a system to infer SOL flows from the dispersal of C +1 and C +2 plumes. 2 Experimental Arrangement A cross-section of the Alcator C-Mod vacuum chamber with a layout of the main diagnostics for the gas-injection system is shown in Figure 1. This system consists of two near-perpendicular views of a reciprocating fast-scanning probe (FSP) designed to injected gas locally into the SOL at the probe s end-ofstroke. For these experiments deuterated ethylene (C 2 D 4 ) was used as the working gas, with 5 x 1 16 molecules of gas typically injected per probe scan. The probe head is machined from a molybdenum cylinder and has four tungsten electrodes. Views are obtained using fiber optic bundles coupled to gated, intensified CCD cameras through beam-splitter optics. The majority of this system is described in detail in [4] the new features are the beamsplitters, composed of mirrors, lenses, and bandpass interference filters, which allow for the simultaneous acquisition of C +1 (CII) and C +2 (CIII) emission at each view location. 2

Cross Section of Alcator C-Mod Showing Injection Location and Views Top View of Gas Injection Location Four Langmuir Probe Elements: 1.5 mm diameter tungsten wires, cut to match pyramidal surface Plume North East West South 16mm -Field Gas Injection Location Side View of Gas Injection Location Close-up view of probe elements along axis of pyramid Gas-Injecting, Fast-Scanning Probe Fig. 1. (a) Cross-section of the Alcator C-Mod vacuum chamber with a typical diverted equilibrium. Gas is injected locally into the scrape-off layer at the end of stroke of a vertically-scanning probe. Impurity emission plumes are viewed from two near-perpendicular locations. (b) Close-up view of molybdenum probe head, indicating the location of the gas-injection capillary and the Langmuir probe elements used for density and temperature measurements and for providing estimates of the background flow. 3 Initial results 3.1 Plume emission patterns in the near and far SOL False color images of CII (514.1 nm) and CIII (465. nm) emission recorded by the CCD cameras are shown in Figure 2 for a pair of ohmic L-mode discharges taken at different depths in the SOL. In the side view (SVC), emission is partly obscured by the probe head, while in the top view (TVC) the probe head contributes some reflected light. A schematic of the probe head is shown in each figure. Asymmetries exist in both the parallel and cross-field structure of plume emission. Parallel asymmetries are related to background parallel flows, and the nature of these asymmetries is seen to vary with distance in the SOL (far SOL strong asymmetry indicating flow towards the divertor; near SOL asymmetry indicating reversed flow). In the cross-field direction, it is observed that the tails of the emission are bent further off of the axis of emission as distance 3

is increased from the injection location. This boomerang effect is thought to be due to the E drift of impurity ions resulting from the prescence of a radial electric field in the SOL. This effect is rather weak for plumes in the far SOL, but can be much stronger for plumes near the separatrix. In both cases the direction of the boomerang implies that E r is directed radially outward, i.e. E r >. This is true for the majority of plumes studied. Side view Top view vertical distance (cm) radial distance (cm) 1 5 1 CIII increasing Z CII towards the divertor towards the divertor 5 increasing Z FSP 1 2 3 1 2 3 toroidal distance (cm) toroidal distance (cm) 1 5 1 5 Far SOL (ρ = 12 mm) CIII increasing R CII towards the divertor Near SOL (ρ = mm) FSP CIII CIII increasing R 5 1 15 2 25 5 1 15 2 25 toroidal distance (cm) toroidal distance (cm) CII CII towards the divertor Pixel value (arb. units) 135 11 86 61 37 Pixel value (arb. units) 231 189 147 15 63 Fig. 2. Smoothed CII (514.1 nm) and CIII (465. nm) emission data from the side (SVC) and top (TVC) views. oth data were taken during Ohmic L-mode discharges. Data on the left was taken at a position in the far scrape-off layer, whereas data on the right was taken at the separatrix (indicated by ρ, which represents distance across flux surfaces mapped to the midplane). A schematic of the probe head is drawn in each figure to indicate its perturbance. An approximate local magnetic field direction is indicated to orient the emission. 3.2 Carbon source distribution Experimental results suggest that two sources of carbon contribute to plume formation carbon ions formed from prompt breakup of C 2 D 4 gas and carbon sputtered from a deposited layer on the probe head. A close-up view of an experimental CIII TVC plume (mapped to field-aligned coordinates using the 4

EFIT magnetic reconstruction code [5]) is shown in Figure 3 (top panel). A simulated plume (to be discussed in section 4.3) is shown in the bottom panel. distance across (cm) distance across (cm) 6 4 2-2 -4 6 4 2-2 -4 Experiment "Jet"-like region rightness (W/m 2/ster) -1-5 5 1 distance along (cm) Simulation rightness (W/m 2/ster).84.69.53.38.23.84.69.53.38.23-1 -5 5 1 15 distance along (cm) Fig. 3. Comparison between experimental and simulated CIII TVC plumes. Top panel: CIII TVC plume generated at the separatrix during discharge 11126, 95 ms (n e = 1.14 x 1 2 m 3, T e = 6 ev). Emission has been absolutely calibrated and mapped to field-aligned coordinates using the EFIT reconstruction code. ottom panel: Simulated CIII TVC plume. Density and temperature profiles measured by the scanning probe for discharge 11126, 95 ms are used in the simulation. Code inputs are: M = -.46 (constant over source region); v = 2.2 km/s (towards the divertor) at the injection location, corresponding to E r = 11 kv/m for this discharge; λ ( = source e-folding length) = 1.2 cm; U ( = surface binding energy) = 2 ev; D = 1 m 2 /s. The experimental emission pattern is characterized by large cross-field width and jet -like behavior. ased on the injection capillary diameter (1 mm), and typical diffusivities (D.1-1 m 2 /s) and ionization times (τ ion 1-1 µs) for C +2 in the SOL, the cross-field width of CIII plumes is expected to be 1-3 mm. However, experimental results indicate a much larger cross-field width, 7-1 mm. This would be consistent with plume emission generated from sput- 5

tering of re-deposited carbon on the molybdenum probe head. Experimental evidence for this exists in the form of plumes generated in a discharge without gas injection following a discharge with gas injection. Near the gas injection location (along ), plumes exhibit a jet -like structure, as particles in the shadow of the probe seem to flow more strongly away from the probe than particles outside the probe shadow. This behavior is related to the injection source, as it is not seen in plumes generated without gas injection. In this paper, we focus on the development of a sputter source model of the plume emission to simulate the overall extent of the carbon dispersal (the issue of the jet is revisited later). 4 Plume modeling 4.1 Impurity transport model Extraction of plasma flows from emission data requires modeling of the plume structure. This is done using LIM [6], a 3-D Monte Carlo code describing the transport of impurities generated from a limiter surface. Inputs to the code include background transport parameters (v, v E r, D ), as well as background density and temperature profiles, in this case obtained from probe measurements. The primary outputs of the code are 3-D density distributions for each impurity charge state. Numerical simulations of the camera views are used to image the simulated emission, producing 2-D brightness data which can be directly compared with experimental results. Transport parameters are then varied to obtain a match between simulation and experiment. Plumes are simulated using a sputter source model neutral carbon atoms are launched from the probe surface with a Thompson velocity distribution relative to the local surface normal [7]. The surface binding energy, U, is specified as a code input. The source strength is assumed to vary exponentially with distance from the injection location along the probe axis the e-folding length, λ, is also a code input. 4.2 Sensitivity Study Sensitivity studies have been conducted to investigate the affect various code parameters have on the overall plume shape. An example of the affect of finite poloidal flow (due to E drifts) on simulated CIII TVC plumes is shown 6

6 4 2 No poloidal flow rightness (W/m 2/ster).84.69.53.38.23 distance across (cm) -2-4 6 4 2 Poloidal flow profile rightness (W/m 2/ster).84.69.53.38.23-2 -4-1 -5 5 1 15 distance along (cm) Fig. 4. Simulated CIII top view plumes for cases with and without poloidal flows. Density and temperature profiles near the separatrix for a typical medium density, ohmic L-mode discharge are used. Top panel: No poloidal flow. The boomerang is due to the radial skewness in the impurity density resulting from the radial variation of the ionization rate. ottom panel: Poloidal flow profile, with flows directed towards the divertor (E r > ) and a value of 225 m/s at the injection location. oth poloidal flow (due to E drifts) and radial ionization rate variation contribute to the overall boomerang in the plume. in Figure 4. Typical density and temperature profiles near the separatrix for a medium density ohmic L-mode discharge are assumed. In the top panel, no poloidal flow is given in the simulation. Nonetheless, the emission exhibits a boomerang shape consistent with E r <! This boomerang arises because of the radial variation of the ionization rate, which causes a radial skewness in the impurity density. This skewness is towards regions of low n e and T e, i.e. outward in major radius as seen from the top view and vertically downwards as seen from the side (not shown). In the bottom panel a poloidal flow profile has been inputted, with flow directed towards the divertor, (E r > ; v E at the injection location = 225 m/s), causing the plume boomerang to change direction. For E r >, the boomerang resulting from the poloidal skewness in the plumes is radially inwards when seen from the top view and vertically downwards when seen from the side. Thus, when E r is positive, the effect of ionization rate variation is to increase the plume boomerang in the side view 7

and to decrease the boomerang (or change its direction if E drifts are small) in the top view. Other effects found to have a significant influence on the plume shape include the prescence of flows and electric fields in the presheath and the neutral source e-folding length. Presheath fields tend to reduce the effective parallel velocity of impurities away from the probe, causing the parallel emission profile to be more peaked and the plume boomerang to increase. As the neutral source e- folding length, λ, is increased, the cross-field width and parallel asymmetry in the plume emission are also seen to increase. This results from the pyramidal probe shape yielding a larger source size with increased λ, and a larger fraction of neutrals consequently being launched in regions of colder and less dense plasma, where ionization rates are decreased and coulomb momentum transfer cross-sections are increased. These particles have a longer effective lifetime and are more strongly coupled to the background plasma, allowing them more opportunity to cross-field diffuse and to acquire the background flow velocity. 4.3 Simulation of experimental data LIM has been used to simulate an experimental CIII TVC plume generated at the separatrix during an ohmic L-mode discharge (n e = 1.14 x 1 2 m 3, T e = 6 ev). False color images of the experimental and simulation results are shown in Figure 3. Input parameters for this case are: M = -.46 (constant over the source region); v = 2.2 km/s (towards the divertor) at the injection location, corresponding to E r = 11 kv/m for this discharge; λ = 1.2 cm; U = 2 ev; D = 1. m 2 /s. ased on these results, a net poloidal flow can be calculated, by summing together the poloidal projection of the parallel flow (v θ ) with the E flow. For this case the result is v θ,net = -2 km/s, implying a net poloidal flow away from the divertor. However, other measurements on Alcator C-Mod suggest that near the separatrix the net poloidal flow velocity is small, i.e. that to a large degree the poloidal projection of the parallel flow cancels the E flow [2]. In addition, the values for M and E r disagree with those measured by the scanning probe: M,probe = -.2, E r,probe = -2 kv/m. What are the causes for these discrepancies? One problem is the inability of the simulated plumes to re-create the jet-like behavior seen in the experiment. As mentioned previously, this phenomenon is related to the direct injection source, which is not presently being modeled in LIM. This jet results in broad parallel profiles in the emission to simulate the overall extent of the plume without a jet, an artifically high value of U (surface binding energy) is required, which results in the average speed 8

of particles away from the injection location also being large. To match the parallel asymmetry in the experimental emission, a large background flow is then necessary. Incorrect modeling of the source profile may also affect what cross-field flows are required to match the plume boomerang, leading to errors in E r. In addition, the plumes exist over a finite volume, and values for v and E r inferred from the emission structure are averages weighted by the impurity distribution. Difficulties may arise in comparing these values with localized measurements from the scanning probe. The probe measures E r < for this case, whereas plume modeling implies E r >. Regardless of whether the magnitude of E r is correctly assessed by the modeling, the direction of the experimental boomerang implies that E r must be positive. This result suggests the probe measurement is incorrect. Probe measurements of E r involve taking the derivative of the local plasma potential, which itself involves summing the sheath potential (inferred by multiplying the electron temperature by a scale factor) with the floating potential. Near the separatrix these are large offsetting quantities, so that their sum may be subject to large errors. Recently, a comparison of E r inferred from fluctuation propagation velocities with that inferred from probe-sheath potential drop has been performed [2] results suggest that the latter technique may be unreliable. Thus, near the separatrix the plumes may provide a more reliable measurement of E r. 5 Summary A novel system has been developed for determining flows in the SOL of Alcator C-Mod. A reciprocating fast-scanning probe has been designed to inject gas locally in the SOL, while two near-perpendicular views of the probe provide images of the resulting impurity dispersal plumes. Parallel and cross-field flows are inferred from modeling the dimension and structure of the plumes. Experimental results suggest that both the direct injection source and sputtering of re-deposited carbon on probe head contribute to the plume emission. Modeling thus far has focused on development and implementation of a sputter source. A Monte Carlo impurity transport code is used to model the plume emission, and to investigate which parameters affect plume structure. Plume shape is found to be sensitive to radial variations in the impurity ionization rate. These variations result in a boomerang in the emission, which adds to or subtracts from the boomerang due to E flows, depending on the sign of E r and the geometry of the view. Plume structure has also been found to depend on 9

presheath physics and neutral launch dynamics. Simulation of an experimental plume has been performed, allowing v and E r to be extracted from the emission data. These results do not compare well with those obtained from probe measurements. This may be due to jet -like behavior observed in the experimental plume emission which is not presently modeled. Averaging resulting from the finite emission volume may also lead to discrepancies between plume results and probe measurements. Finally, there is evidence that the probe measurement of E r is incorrect. From the direction of the plume boomerang, the sign of E r can be directly inferred for the case studied, this value is positive, which is inconsistent with the probe estimate of E r. In this regard, the plumes may ultimately provide a more robust measurement of this quantity near the separatrix region. Acknowledgements The authors would like to thank David Elder and Steve Lisgo at the University of Toronto for their assistance with LIM modeling. This work is supported by US Department of Energy Contract No. DE-AC2-78-ET-5113. References [1]. Laombard, M.V. Umansky, et al., Nucl. Fusion 4 (2) 241. [2]. Labombard, et al., these proceedings. [3]. Laombard, S. Gangadhara, et al., J. Nucl. Mater. 266-269 (1999) 571. [4] S. Gangadhara,. Laombard, et al., J. Nucl. Mater. 29-293 (21) 598. [5] L.L. Lao, et al., Nucl. Fusion 25 (1985) 1611. [6] P.C. Stangeby, et al., Nucl. Fusion 28 (1988) 1945. [7] R.A. Langley, et al., Data Compendium for Plasma-Surface Interactions, Nucl. Fusion Special Issue 1984, IAEA, Vienna (1984) 61. 1