Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

Similar documents
Journal of Chemical and Pharmaceutical Research

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 7(2),

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry

Sulfotepp impurities in Chlorpyrifos EC formulations

Development and Validation of GC-FID Method for the Quantification of N-Iodosuccinimide

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

GAS CHROMATOGRAPHY (GC)

STANDARD OPERATING PROCEDURES

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

2.1 2,3 Dichloro Benzoyl Cyanide (2,3 DCBC) and survey of. manufactured commonly for the bulk drug industry, few references were

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Anethole. Gas chromatograhpy determination of trans-anethole in Spirit srinks of viti-vinicultural origin

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Study of Residual Solvents in Various Matrices by Static Headspace

STABILITY INDICATING METHOD OF RELATED IMPURITIES IN VENLAFAXINE HYDROCHLORIDE SUSTAINED RELEASE TABLETS

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)

DEVELOPMENT AND VALIDATION OF GC-FID METHOD FOR THE DETERMINATION OF ETHANOL RESIDUE IN MARJORAM OINTMENT

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Development and Validation of a Headspace Gas Chromatographic Method for determination of Residual Solvents in Bosentan Monohydrate.

DIQUAT DIBROMIDE. The Determination of Ethylene Dibromide in Diquat Dibromide and Diquat Dibromide / Paraquat Dichloride SL Formulations

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Development and validation a RP-HPLC method: Application for the quantitative determination of quetiapine fumarate from marketed bulk tablets

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

SIMULTANEOUS RP HPLC DETERMINATION OF CAMYLOFIN DIHYDROCHLORIDE AND PARACETAMOL IN PHARMACEUTICAL PREPARATIONS.

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Method Development and Validation for the Estimation of Darunavir in Rat Plasma by RP-HPLC

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

Turkish raki is the most popular traditional distilled

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD TO DETERMINE CINITAPRIDE HYDROGEN TARTARATE IN BULK AND PHARMACEUTICAL FORMULATION

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Journal of Chemical and Pharmaceutical Research, 2017, 9(10): Research Article

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

637. Thiamethoxam. HPLC method

A Fast and Sensitive Method for Residual Hydrazine Analysis in Pharmaceutical Samples

Development and Validation of a HPLC Method for Chlorphenamine Maleate Related Substances in Multicomponents Syrups and Tablets

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

METHOD: 1403, Issue 3 EVALUATION: FULL Issue 1: 15 August 1990 Issue 3: 15 March 2003

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

A Capillary Gas Chromatographic Procedure for the Analysis of Nine Common Residual Solvents in Water-Insoluble Bulk Pharmaceuticals

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

ENVIRONMENTAL analysis

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Residual solvents analysis using an Agilent Intuvo 9000 GC system

Limit-test of NDMA and NDEA in Sartans. by GC-MS (Liquid-direct-injection)

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

Volume 6, Issue 2, January February 2011; Article-015

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Fast Analysis of USP 467 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

SIMULTANEOUS DETERMINATION OF THREE ACTIVE INGREDIENTS OF A PESTICIDE, USING GAS CHROMATOGRAPHY-FLAME IONIZATION DETECTOR

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Routine-grade performance of a new static headspace autosampler for the analysis of residual solvents according to USP <467> method

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Method for Characterization of Gum Rosin by Capillary Gas Chromatography

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

A Simple, Novel Validated Stability Indicating RP-HPLC method for estimation of Duloxetine HCl in Capsule Pharmaceutical Formulation

Department of Post graduate Chemistry, SVRM College (Autonomous) Nagaram, Andhra Pradesh, India Corresponding Author:

Application. Gas Chromatography February Introduction

1. A gas chromatograph equipped with flame ionization detection and a computing integrator.

Method for the determination of dimethyl sulfate

USP<467> residual solvents

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

Research Article. Identification and characterization of unknown impurity in zolmitriptan tablets by a sensitive HPLC method

Journal of Chemical and Pharmaceutical Research, 2017, 9(1): Research Article

Hydrogen as a Carrier Gas in the Analysis of Polar/Non-Polar Compounds Using the Polyarc System. Application Note. Author. Introduction.

Pelagia Research Library

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Impact factor: 3.958/ICV: 4.10 ISSN:

Int. J. Pharm. Sci. Rev. Res., 30(2), January February 2015; Article No. 09, Pages: 63-68

Determination of releasable 2,4,6-trichloroanisole in wine by cork stoppers (Resolution OIV-Oeno 296/2009)

Analysis of Terpenes in Cannabis Using the Agilent 7697A/7890B/5977B Headspace GC-MSD System

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Journal of Chemical and Pharmaceutical Research

Fast Gas Chromatography using Heated Headspace Gas Auto Sampling Techniques: Ethylene Oxide and 1,4-Dioxane in Fatty Acids

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

GC METHOD FOR QUANTITATIVE DETERMINATION OF RESIDUAL 2-(2-CHLOROETHOXY)ETHANOL (CEE) AND N-METHYL-2-PYRROLIDINONE (NMP) IN QUETIAPINE

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Novus International Journal of Analytical Innovations 2012, Vol. 1, No. 3

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

Transcription:

Trade Science Inc. September 2009 Volume 8 Issue 3 ACAIJ, 8(3) 2009 [346-349] Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection K.Rama Seshaiah* 1,2, V.Krishna Reddy 1, Ch.Krishnaiah 1, VVNKV Prasadaraju 1, K.Mukkanti 2, V.Ranga Reddy 1 1 Dr.Reddy s Laboratories Ltd. Active pharmaceutical ingredients, IPDO, Bachupally, Hyderabad-500072, A.P, (INDIA) 2 Department of chemisty, J.N.T.University, Kukatpally, Hyderabad-500072, A.P, (INDIA) E-mail: ramask@drreddys.com Received: 26 th May, 2009 ; Accepted: 5 th June, 2009 ABSTRACT A capillary gas chromatographic method using flame ionization detection was developed and validated for the trace analysis (ppm level) of mesityl oxide and diacetone alcohol in pharmaceutical drug substance. The method utilizes a megabore capillary column with bonded and crosslinked polyethylene glycol stationary phase. A dissolve-and-injection approach was adopted for sample introduction in a split mode (1:1). Water is used as sample solvent. A limit of detection of about 1.5 and 2 ppm and limit of quantitation of about 6 and 10 ppm were achieved for the Mesityl oxide and Diacetone alcohol in drug substance samples. The method optimization and validation are also discussed in this paper. 2009 Trade Science Inc. - INDIA KEYWORDS Pharmaceutical analysis; Mesityl oxide and Diacetone alcohol. INTRODUCTION Recently, the potential health hazards of trace amounts of mesityl oxide and diacetone alcohol in pharmaceuticals have attracted the attention of regulatory authorities. These are known to be potent carcinogenic compounds [1-3]. Their presence in the pharmaceutical products may be the result of leftover starting materials, or formed as by-products between acid, base (often used as a counter ion) and ketone (often used as solvents in manufacturing process). Although official guidelines [4-5] have not been established, the concentration of these compounds are expected to be controlled at a level less than or equal to 10ppm.Therefore, it is of great importance to develop analytical methods that are sensitive enough and meet all the regulatory requirements. The pure mesityl oxide and diacetone alcohol are liquids at ambient temperature with a boiling point around 130 C and 170 C respectively. Therefore, it is feasible to separate and quantify these compounds by gas chromatography. The analysis of the mesityl oxide and diacetone alcohol using HPLC is not straightforward because of the specific chemical and physical properties of these compounds. This short communication describes a simple and sensitive method for the determination of mesityl oxide and diacetone alcohol in pharmaceuticals using capillary GC with flame ionization detection (FID). The limit of detection and limit of quantitation were determined

ACAIJ, 8(3) September 2009 to be about 2ppm and 10ppm per gram of API, respectively. The method utilizes a dissolve-and-inject approach for sample preparation and introduction. The samples were injected in the split mode and quantitation was achieved using a single point external standard calibration. Instrumentation EXPERIMENTAL An Agilent 6890 GC (Agilent, Palo Alto, CA, USA) equipped with an auto sampler was used in the experiment. Data acquisition and processing were conducted using the Waters Empower software. Chemicals Mesityl oxide and Diacetone alcohol were purchased from Aldrich Chemical (Milwaukee, WI, USA). HPLC grade equivalent water was obtained from an in-house Millipore Milli-Q-Gradient ultrapure water system (Millipore, Billerica, MA, USA). This study also involves two proprietary Dr. Reddy s Laboratories Pharmaceutical Research & Development compounds. Preparation of Solutions The stock solutions of mesityl oxide and diacetone alcohol were prepared by dissolving 5.8 L and 5.3 L each of the compounds in sample solvent. The diluted stock solution (standard solution) was prepared by pipetting 10 L each of the stock solutions into a 10- ml volumetric flask and diluting to volume with sample solvent. The sample solution was prepared by accurately weighing about 50 mg of the drug substance into a 2-mL GC vial and adding 1.0 ml of sample solvent. Operating Conditions The GC separation was conducted on an Alltech AT-WAX column with a dimension of 30 m 0.53 mm and a film thickness of 1 m. Helium was used as carrier gas at a constant flow of 2.6psi. The GC oven temperature program utilized an initial temperature of 50 C and an initial holding time of 6 min, then increased at 8 C/min to 115 C with a hold time of 6 min, then increased at 35 C/min to 220 C. The final temperature was held for 10 min. A flame ionization detection (FID) system was used. K.Rama Seshaiah et al. 347 The H2, air, makeup flows were kept at 30, 350 and 30 ml/min, respectively. The detector temperature was set at 260 C. The samples were injected with the Agilent 6890 series auto sampler. The inlet temperature was kept at 110 C. A straight glass injection liner with glass wool was obtained from Restek, (Restek, Bellefont, PA, USA). The samples were injected in a split mode (1:1) with a 1- L injection volume unless otherwise specified. RESULTS AND DISCUSSION Method Development and Optimization The main challenge was to achieve the desired detection and quantitation limit using the most commonly available instrument, i.e. a gas chromatograph with a FID system. To obtain the desired sensitivity, one approach is to increase sample amount injected into the GC system. The adoption of a megabore capillary GC column (0.53 mm I.D.) with a high capacity bonded stationary phase seems to be the obvious choice. Suitable initial column temperature in combination with a moderate inlet temperature (120 C) may allow a relatively large injection volume without significant deterioration in column efficiency. The effect of injection volume on the quantitation of the mesityl oxide and diacetone alcohol was investigated by injecting between 0.5 L and 3 L of the standard solution containing 10ppm each of mesityl oxide and diacetone alcohol. The results show that the peak widths of mesityl oxide and diacetone alcohol are independent of injection volume within the tested range. Further studies were not done to determine the maximum injection volume that the chromatographic system could handle because interfering peaks from the sample solvent started being detected when the injection volume was greater than 2 L in our experiments. An injection volume of 1 L was chosen for this method as it will not over load the column. The effect of inlet temperature on the drift of the baseline was investigated. The inlet temperature was varied from 100 to 200 C. An aliquot of 1 L of the sample was injected in the split mode. The results show that at an inlet temperature more than 130 C there is a

348 Trace Analysis of Mesityl Oxide. and Diacetone Alcohol drift in the baseline which will effect the quantification of diacetone alcohol. An inlet temperature of 110 C was chosen, which allowed smooth baseline. This method utilizes a dissolve-and-inject approach for the analysis. Several factors were considered in selection of a sample solvent, including the purity, its ability to dissolve the analyte, and its chemical compatibility with the compounds of interest. To detect the mesityl oxide and diacetone alcohol at 2ppm level, the purity of sample solvent is critical. It has been observed in our laboratory that the HPLC grade solvents are generally suitable. The tested sample concentration of drug substances was in the range of 40 100 mg/ml. The use of water was successfully used for one of the inhouse compounds for the residue analysis (Fig 1). The mesityl oxide and diacetone alcohol showed reasonable stability in the aqueous solution. This is important because many pharmaceuticals are in salt forms, which sometimes show limited solubility in pure organic solvents. pa 12.00 11.80 11.60 11.40 11.20 11.00 10.80 10.60 10.40 10.20 10.00 9.80 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 26.00 28.00 30.00 32.00 Minutes Figure 1 : Chromatogram of sample solvent Method Validation A Critical parameters of validation was done for the developed work. The validated method parameters include establishment of limit of detection, limit of quantification, precession at limit of quantification and accuracy at limit of quantification was done. The detection limit (LOD) of the method for the mesityl oxide and diacetone alcohol was estimated from a chromatogram of a solution containing about 1.5ppm and 2.0ppm respectively. From the chromatogram, a signal-to-noise ratio of 2.8 and 3.0, was obtained for mesityl oxide and diacetone alcohol respectively. In the pharmaceutical industry, the quantitation limit (LOQ) was defined as the lowest amount of analyte in a sample that can be quantitatively determined with suitable precision and accuracy. The LOQ was determined to be ACAIJ, 8(3) September 2009 6ppm and 10ppm respectively for mesityl oxide and diacetone alcohol (Fig 2) based on the precision and accuracy data discussed below. Figure 2 : Chromatogram of a standard solution containing 6ppm and 10ppm of mesityl oxide and diacetone alcohol respectively. The experimental results also show that this method has excellent precision without using an internal standard. Multiple injections were made for the standard solutions containing 6ppm and 10ppm respectively of mesityl oxide and diacetone alcohol. For six injections of the solution, the R.S.D. of the peak area of mesityl oxide was 7.8% and for diacetone alcohol was 8.2% Accuracy of the method was determined by analyzing drug substance samples spiked with limit of quantification amount of the mesityl oxide and diacetone alcohol. The recovery was 122% for mesityl oxide and 91% for diacetone alcohol Because this method uses the dissolve-and-inject approach, for every sample injection, about 500 g of the drug substance is introduced in the injection port. The accumulation of drug substance may have negative effect on the recovery. Therefore the injection liner should be replaced after every sequence of 15 20 injections. CONCLUSION A simple and sensitive GC method has been developed and validated for the trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals. The mini validation was performed. Compared with the previously reported methodologies, this method utilizes a FID detector, which is readily available in most of the quality control testing laboratories in the pharmaceutical industry and relatively simple to use. This method is sensitive enough to detect 1.5ppm of mesityl oxide, 2.0ppm

ACAIJ, 8(3) September 2009 of diacetone alcohol and quantify 6ppm of mesityl oxide, 10ppm of diacetone alcohol in pharmaceutical products. K.Rama Seshaiah et al. 349 REFERENCES [1] Sara P.Fore, H.P.Dupuy, E.T.Rayner; Southern Regional Research Center 2, New Orleans, Louisiana 70179, J.Am.Oil Chem.Soc. [2] Afafk Amar, A lexandebra Ldwiny Oung, A.N.S.Raymonedv; M. Arch., Department of Chemistry, Trent University, Peterborough, Ont., Canada, K9J 7B8, J.Chem., 64, 1979 (1986). [3] D.A.Cronin, H.E.Nursten, J. A.M.L.Woolfe; Int.J.Mass Spectrom.Ion Phys. [4] ICH Guide Q3A: Impurities in New Drug Substances, International Conference on harmonization. Fed. Reg. (68 FR 6924), 11 February (2003). [5] ICH Guide Q3B: Impurities in New Drug Products, International Conference on harmonization. Fed. Reg. (62 FR 27454), 19 May (1997).

Trade Science Inc. September 2009 Volume 8 Issue 3 ACAIJ, 8(3) 2009 [346-349] Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection K.Rama Seshaiah* 1,2, V.Krishna Reddy 1, Ch.Krishnaiah 1, VVNKV Prasadaraju 1, K.Mukkanti 2, V.Ranga Reddy 1 1 Dr.Reddy s Laboratories Ltd. Active pharmaceutical ingredients, IPDO, Bachupally, Hyderabad-500072, A.P, (INDIA) 2 Department of chemisty, J.N.T.University, Kukatpally, Hyderabad-500072, A.P, (INDIA) E-mail: ramask@drreddys.com Received: 26 th May, 2009 ; Accepted: 5 th June, 2009 ABSTRACT A capillary gas chromatographic method using flame ionization detection was developed and validated for the trace analysis (ppm level) of mesityl oxide and diacetone alcohol in pharmaceutical drug substance. The method utilizes a megabore capillary column with bonded and crosslinked polyethylene glycol stationary phase. A dissolve-and-injection approach was adopted for sample introduction in a split mode (1:1). Water is used as sample solvent. A limit of detection of about 1.5 and 2 ppm and limit of quantitation of about 6 and 10 ppm were achieved for the Mesityl oxide and Diacetone alcohol in drug substance samples. The method optimization and validation are also discussed in this paper. 2009 Trade Science Inc. - INDIA KEYWORDS Pharmaceutical analysis; Mesityl oxide and Diacetone alcohol. INTRODUCTION Recently, the potential health hazards of trace amounts of mesityl oxide and diacetone alcohol in pharmaceuticals have attracted the attention of regulatory authorities. These are known to be potent carcinogenic compounds [1-3]. Their presence in the pharmaceutical products may be the result of leftover starting materials, or formed as by-products between acid, base (often used as a counter ion) and ketone (often used as solvents in manufacturing process). Although official guidelines [4-5] have not been established, the concentration of these compounds are expected to be controlled at a level less than or equal to 10ppm.Therefore, it is of great importance to develop analytical methods that are sensitive enough and meet all the regulatory requirements. The pure mesityl oxide and diacetone alcohol are liquids at ambient temperature with a boiling point around 130 C and 170 C respectively. Therefore, it is feasible to separate and quantify these compounds by gas chromatography. The analysis of the mesityl oxide and diacetone alcohol using HPLC is not straightforward because of the specific chemical and physical properties of these compounds. This short communication describes a simple and sensitive method for the determination of mesityl oxide and diacetone alcohol in pharmaceuticals using capillary GC with flame ionization detection (FID). The limit of detection and limit of quantitation were determined

ACAIJ, 8(3) September 2009 to be about 2ppm and 10ppm per gram of API, respectively. The method utilizes a dissolve-and-inject approach for sample preparation and introduction. The samples were injected in the split mode and quantitation was achieved using a single point external standard calibration. Instrumentation EXPERIMENTAL An Agilent 6890 GC (Agilent, Palo Alto, CA, USA) equipped with an auto sampler was used in the experiment. Data acquisition and processing were conducted using the Waters Empower software. Chemicals Mesityl oxide and Diacetone alcohol were purchased from Aldrich Chemical (Milwaukee, WI, USA). HPLC grade equivalent water was obtained from an in-house Millipore Milli-Q-Gradient ultrapure water system (Millipore, Billerica, MA, USA). This study also involves two proprietary Dr. Reddy s Laboratories Pharmaceutical Research & Development compounds. Preparation of Solutions The stock solutions of mesityl oxide and diacetone alcohol were prepared by dissolving 5.8 L and 5.3 L each of the compounds in sample solvent. The diluted stock solution (standard solution) was prepared by pipetting 10 L each of the stock solutions into a 10- ml volumetric flask and diluting to volume with sample solvent. The sample solution was prepared by accurately weighing about 50 mg of the drug substance into a 2-mL GC vial and adding 1.0 ml of sample solvent. Operating Conditions The GC separation was conducted on an Alltech AT-WAX column with a dimension of 30 m 0.53 mm and a film thickness of 1 m. Helium was used as carrier gas at a constant flow of 2.6psi. The GC oven temperature program utilized an initial temperature of 50 C and an initial holding time of 6 min, then increased at 8 C/min to 115 C with a hold time of 6 min, then increased at 35 C/min to 220 C. The final temperature was held for 10 min. A flame ionization detection (FID) system was used. K.Rama Seshaiah et al. 347 The H2, air, makeup flows were kept at 30, 350 and 30 ml/min, respectively. The detector temperature was set at 260 C. The samples were injected with the Agilent 6890 series auto sampler. The inlet temperature was kept at 110 C. A straight glass injection liner with glass wool was obtained from Restek, (Restek, Bellefont, PA, USA). The samples were injected in a split mode (1:1) with a 1- L injection volume unless otherwise specified. RESULTS AND DISCUSSION Method Development and Optimization The main challenge was to achieve the desired detection and quantitation limit using the most commonly available instrument, i.e. a gas chromatograph with a FID system. To obtain the desired sensitivity, one approach is to increase sample amount injected into the GC system. The adoption of a megabore capillary GC column (0.53 mm I.D.) with a high capacity bonded stationary phase seems to be the obvious choice. Suitable initial column temperature in combination with a moderate inlet temperature (120 C) may allow a relatively large injection volume without significant deterioration in column efficiency. The effect of injection volume on the quantitation of the mesityl oxide and diacetone alcohol was investigated by injecting between 0.5 L and 3 L of the standard solution containing 10ppm each of mesityl oxide and diacetone alcohol. The results show that the peak widths of mesityl oxide and diacetone alcohol are independent of injection volume within the tested range. Further studies were not done to determine the maximum injection volume that the chromatographic system could handle because interfering peaks from the sample solvent started being detected when the injection volume was greater than 2 L in our experiments. An injection volume of 1 L was chosen for this method as it will not over load the column. The effect of inlet temperature on the drift of the baseline was investigated. The inlet temperature was varied from 100 to 200 C. An aliquot of 1 L of the sample was injected in the split mode. The results show that at an inlet temperature more than 130 C there is a

348 Trace Analysis of Mesityl Oxide. and Diacetone Alcohol drift in the baseline which will effect the quantification of diacetone alcohol. An inlet temperature of 110 C was chosen, which allowed smooth baseline. This method utilizes a dissolve-and-inject approach for the analysis. Several factors were considered in selection of a sample solvent, including the purity, its ability to dissolve the analyte, and its chemical compatibility with the compounds of interest. To detect the mesityl oxide and diacetone alcohol at 2ppm level, the purity of sample solvent is critical. It has been observed in our laboratory that the HPLC grade solvents are generally suitable. The tested sample concentration of drug substances was in the range of 40 100 mg/ml. The use of water was successfully used for one of the inhouse compounds for the residue analysis (Fig 1). The mesityl oxide and diacetone alcohol showed reasonable stability in the aqueous solution. This is important because many pharmaceuticals are in salt forms, which sometimes show limited solubility in pure organic solvents. pa 12.00 11.80 11.60 11.40 11.20 11.00 10.80 10.60 10.40 10.20 10.00 9.80 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 26.00 28.00 30.00 32.00 Minutes Figure 1 : Chromatogram of sample solvent Method Validation A Critical parameters of validation was done for the developed work. The validated method parameters include establishment of limit of detection, limit of quantification, precession at limit of quantification and accuracy at limit of quantification was done. The detection limit (LOD) of the method for the mesityl oxide and diacetone alcohol was estimated from a chromatogram of a solution containing about 1.5ppm and 2.0ppm respectively. From the chromatogram, a signal-to-noise ratio of 2.8 and 3.0, was obtained for mesityl oxide and diacetone alcohol respectively. In the pharmaceutical industry, the quantitation limit (LOQ) was defined as the lowest amount of analyte in a sample that can be quantitatively determined with suitable precision and accuracy. The LOQ was determined to be ACAIJ, 8(3) September 2009 6ppm and 10ppm respectively for mesityl oxide and diacetone alcohol (Fig 2) based on the precision and accuracy data discussed below. Figure 2 : Chromatogram of a standard solution containing 6ppm and 10ppm of mesityl oxide and diacetone alcohol respectively. The experimental results also show that this method has excellent precision without using an internal standard. Multiple injections were made for the standard solutions containing 6ppm and 10ppm respectively of mesityl oxide and diacetone alcohol. For six injections of the solution, the R.S.D. of the peak area of mesityl oxide was 7.8% and for diacetone alcohol was 8.2% Accuracy of the method was determined by analyzing drug substance samples spiked with limit of quantification amount of the mesityl oxide and diacetone alcohol. The recovery was 122% for mesityl oxide and 91% for diacetone alcohol Because this method uses the dissolve-and-inject approach, for every sample injection, about 500 g of the drug substance is introduced in the injection port. The accumulation of drug substance may have negative effect on the recovery. Therefore the injection liner should be replaced after every sequence of 15 20 injections. CONCLUSION A simple and sensitive GC method has been developed and validated for the trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals. The mini validation was performed. Compared with the previously reported methodologies, this method utilizes a FID detector, which is readily available in most of the quality control testing laboratories in the pharmaceutical industry and relatively simple to use. This method is sensitive enough to detect 1.5ppm of mesityl oxide, 2.0ppm

ACAIJ, 8(3) September 2009 of diacetone alcohol and quantify 6ppm of mesityl oxide, 10ppm of diacetone alcohol in pharmaceutical products. K.Rama Seshaiah et al. 349 REFERENCES [1] Sara P.Fore, H.P.Dupuy, E.T.Rayner; Southern Regional Research Center 2, New Orleans, Louisiana 70179, J.Am.Oil Chem.Soc. [2] Afafk Amar, A lexandebra Ldwiny Oung, A.N.S.Raymonedv; M. Arch., Department of Chemistry, Trent University, Peterborough, Ont., Canada, K9J 7B8, J.Chem., 64, 1979 (1986). [3] D.A.Cronin, H.E.Nursten, J. A.M.L.Woolfe; Int.J.Mass Spectrom.Ion Phys. [4] ICH Guide Q3A: Impurities in New Drug Substances, International Conference on harmonization. Fed. Reg. (68 FR 6924), 11 February (2003). [5] ICH Guide Q3B: Impurities in New Drug Products, International Conference on harmonization. Fed. Reg. (62 FR 27454), 19 May (1997).