Tar & (SPA) tar analysis

Similar documents
Tar measurement by the Solid Phase Adsorption (SPA) method

Tar analysis by Solid Phase Adsorption (SPA) associated with Thermal Desorption (TD) and Gas Chromatography (GC) analysis

Magnitudes of Back Diffusion During Long-Term Diffusive Sampling of Volatile Organic Compounds Using Carbotrap and Chromosorb 106

THEORETICAL DETERMINATION OF THE SAMPLING RATES OF DIFFUSION SAMPLERS FOR VOCS AND ALDEHYDES

Chemistry Gas Chromatography: Separation of Volatile Organics

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

Experimental Determination of Pyrolysis Products from Carbon/Resin Ablative Materials

Method for the determination of 1,3-butadiene

Chapter content. Reference

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Open Column Chromatography, GC, TLC, and HPLC

Gas Chromatography. Introduction

BGB Flash Cartridges. Ultra-pure silica-based material. High-performance spherical 30 µm C18, CN, Diol & HILIC. Pressure up to 27 bar (400 psi)

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Raw Material Finished product By product Exposure standards Length of shift Physical environment

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Introduction to Gas Chromatography

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Rapid Catalyst Screening Reactors

HYDROCARBONS, AROMATIC 1501

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Chapter 27: Gas Chromatography

Chromatography. Gas Chromatography

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

Gas Chromatography. Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid

Thermal Soil Desorber Instructions September 2006

Disadvantage: Destructive Technique once analyzed by GC, the sample is lost

Chapter 31 Gas Chromatography. Carrier Gas System

Gas Chromatography (GC)

CHAPTER 6 GAS CHROMATOGRAPHY

Chapter 3: Source Measurement Techniques

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

7 INSTRUMENTAL CHROMATOGRAPHY

A STUDY OF VOLATILE ORGANIC CARBON POLLUTION ON A UNIVERSITY CAMPUS DUE TO TRAFFIC

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Title Experiment 7: Gas Chromatography and Mass Spectrometry: Fuel Analysis

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

2401 Gas (liquid) Chromatography

Emission measurements according to, M1 (3 appendices)

High Performance Liquid Chromatography

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

Determination of Volatile Substances Proof of Food Adulteration

CHEM340 Tutorial 4: Chromatography

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Chapter 11 Conventional Gas Chromatography

REFERENCE DESCRIPTION PROMO NET PRICE

Separation Benzene and Toluene from BTX using Zeolite 13X

Chapter 1. Chromatography. Abdul Muttaleb Jaber

TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES

Chemistry Instrumental Analysis Lecture 31. Chem 4631

Gas Chromatography. Rosa Yu, David Reckhow CEE772 Instrumental Methods in Environmental Analysis CEE 772 #16 2

Real-Time Detection: From Gisclard et al.: A Simple Device for Air Analysis. AIHA Quarterly, 14(1):23-25 (1953)

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

Ch24. Gas Chromatography (GC)

High Pressure/Performance Liquid Chromatography (HPLC)

Paints and varnishes Determination of volatile organic compound (VOC) content. Part 2: Gas-chromatographic method

DETERMINATION OF ON-LINE BREAKTHROUGH VOLUME AND PERCENTAGE RECOVERY OF MODIFIED POLYSTYRENE-DIVINYLBENZENE (PS-DVB) AS CHROMATOGRAPHY ADSORBENT

Understanding Gas Chromatography

Liquid Chromatography

Institute for Chemical Education, Fun With Chemistry; Vol. 1, Sarquis, Mickey and Sarquis, Gerry, Ed.; University of Wisconsin Madison, 1991,

HPLC-MS of the Initial Perfluorinated Surfactants and Shorter Chains:

SURVEY OF CHEMICALS EMISSION FACTORS FROM BUILDING MATERIALS FOR INTERIORS

Vapor Intrusion Sampling Options: Performance Data for Canisters, Badges, and Sorbent Tubes for VOCs

TDTS. Keywords. Introduction. TD Operation; Calibration; Impedance; Discrimination

Headspace Technology for GC and GC/MS: Features, benefits & applications

Muliple Gas#3 plus Sulfur GC Configuration

A biphasic oxidation of alcohols to aldehydes and ketones using a simplified packed-bed microreactor

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

Luminescence transitions. Fluorescence spectroscopy

Volumetric Analysis. Quantitative analysis answers the second question

GC Instruments. GC Instruments - Columns

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

TEPZZ A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.:

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

An Innovative Field-Based Analytical Method For Low-Level Detection of Chlorinated Solvents in Groundwater and Soil Samples

Mass Spectrometry in MCAL

Activity in the FID Detection Port: A Big Problem if Underestimated

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

INTRINSICALLY VALID VOLATILE ORGANIC COMPOUND MEASUREMENTS

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

Preparation. Sample. Solid Phase Extraction (SPE) Discovery Products SUPELCO

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

Sampling. Information is helpful in implementing control measures for reducing pollutant concentration to acceptable levels

Chemistry 311: Instrumental Analysis Topic 4: Basic Chromatography. Chemistry 311: Instrumental Analysis Topic 4: Basic Chromatography

*Correspondence to:

Instrumental Chemical Analysis

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25


2012 Parts Catalog Phone (919) URG

EXECUTIVE SUMMARY. especially in last 50 years. Industries, especially power industry, are the large anthropogenic

Analytical Instrumentation

The Suite for Environmental GC Analysis

Transcription:

Tar & (SPA) tar analysis Truls Liliedahl Chemical Technology School of Chemical Science and Engineering Royal Institute of Technology (KTH) Stockholm, Sweden

Tar when gasifying biomass Gasification at 700-800 C typically gives a condensable fraction (tar) consisting of phenols and aromatic hydrocarbons covering a wide range of molecular weights. As soon as the temperature drops below the tar dew point, the tars will either form aerosols or condense directly on the inner surfaces of the equipment, resulting in plugging and fouling of pipes. Tars may also undergo dehydration reactions to form solid char and coke that further plug up the system. The term "tar" is vague. One definition is "organic molecules with a molecular weight higher than that of benzene (Mw 78).

Tar definitions Light tars = organic compounds that can be analysed with GC as well as HPLC. (Mw 79-300). They are volatile and semi-volatile aromatics and phenolics. Heavy tar = organic compounds with so high boiling points that they can be analysed only by HPLC, not with GC. They are mixtures of high molecular weight non-volatile polar compounds (Mw >300) Total tar = sum of light and heavy tar

Three generic tar compound groups may be found Generic Principle: No phenols No heavy tar

Sampling and analysis principles for tar analysis Cold-solvent-trapping, CST 1 : 100-1000 litres of a gas is passed through a series of impingers containing a ice-cooled solvent. After preparation, samples are subjected to GC to measure individual compounds and gravimetry for total tar. Solid-phase adsorption, SPA 2 : 100 ml producer gas is passed through a disposable cartridge containing 500 mg of amino-phase (modified silica). After preparation, samples are analysed for individual compounds by GC. On-line tar analyser 3 : The method is based on the comparison of the total hydrocarbon content of the hot gas and that of the gas with all tars removed. Hot gas from the gasifier is led directly into the set up. Hydrocarbons are measured with a flame ionisation detector (FID). 1 CEN/TS 15439 Biomass gasification Tar and particles in product gases - Sampling and analysis (May 2006). 2 Brage, C.; Yu, Q.; Chen, G,; Sjöström, K.; Fuel Vol.76, No. 2, pp. 137-142, 1997. 3 Moersch, O.; Spliethoff, H.; Hein, K.R.G. ; Biomass and Bioenergy 18 (2000) 79-86

Drawbacks of principles CST: Long sampling time, laborious and time consuming sample preparation. Not useful for minute-by-minute monitoring. Exhibits a large operator dependence and is thus relatively inaccurate. SPA: Can not be used for heavy tar measurements. BTX analysis can be problematic. On-line analyser: Expensive and poorly documented. Not useful for measurement of individual compounds and low tar concentrations.

Solid-Phase Adsorption (SPA) for analysis of light biomass tar The SPA-method is restricted to GC-available (GA) compounds only. However, these compounds are significant process markers that provide good measures of reactor performance and gas quality. At 850-900 C and above do the GA-compounds roughly correspond to the total tar amount.

SPA, cont SPA is used for the measurement of the concentration (mass) of individual light aromatic hydrocarbons and phenols. The method is used for the measurement of the concentration of individual light aromatic hydrocarbons and phenols. The method involves trapping of tar vapours on to aminopropyl-bonded silica packed in a small polypropene cartridge. Analytes are desorbed by two different eluents and the fractions analysed by gas chromatography (GC) with flame ionisation detection (FID). Following the "like adsorbs like" principle, phenolic compounds are more strongly held on this polar phase than the aromatic compounds. For the aromates and phenolics, repeatability for GC-analysis is less than 1%; repeatability and reproducibility of the method, random errors (sampling, sample preparation and GC-analysis) is typically ±5%. Larger deviation may occur for unknown analytes if the background is high (many small peaks slightly above the FID background signal).

SPA, cont Through traditional SPA may compounds ranging in molecular weight from 78 (benzene) to 300 (coronene) be determined. Benzene Coronene Internal standards for the quantitative analysis are TBCH [tertbutylcyclohexane] and PEP [p-etoxyphenol]. Derivatisation of the phenolic fraction is for improving the chromatographic performance. The method is normaly calibrated for 18 aromatics and 10 phenolics. However, this range can be extended if necessary.

SPA sampling, cont T, needle, SPE-NH2 tube and syringe 100ml. The SPE tube is capped in both ends after sampling. Custom made reversible SPE tube, it consists of a female Luer inlet and a Luer male outlet.

SPA sampling 1 2 3 4 5 6 7 9 8 10 11 1 = to syringe or electrical pump; 2 = adapter (polypropylene); 3 = sample reservoir; 4 = sorbent tube (polypropylene, 1.3 OD x 7.5 cm); 5 = fritted disc (20µm polyethylene); 6 = amino-phase sorbent (40 µm, 60 Å); 7 = rubber/silicone septum; 8 = septum retainer (polypropene); 9 = Tee -adapter (glass); 10 = syringe needle (stainless steel); 11 = producer gas.

SPA sampling For improved BTX-analysis should the GCanalysis be done the same day as the sampling and the cartridge should be caped directly after sampling, preferably with Supelco caps.

Kwik-draw SPA is not a standard, more a principle, thus is it flexible and should be adapted to the given circumstances. A Kwik-draw pump can replace the syringe.

Das Bild kann zurzeit nicht angezeigt werden. SPA sample upgrading and analysis A n a l y s i s S c h e m e f o r G a s i f i c a t i o n T a r T a r i n p r o d u c t g a s e s S a m p l i n g S P A ( S o l i d P h a s e A d s o r b e n t ) u s i n g s y r i n g e o r p u m p S a m p l e p r e p a r a t i o n E l u t i o n ( h e l i u m p r e s s u r e ) A : D C M 1 B : D C M + I P A 2 + A C N 3 A B VISIPREP (Supelco) A n a l y s i s A r o m a t i c c o m p o u n d s P h e n o l i c c o m p o u n d s A n a l y s i s b y G C - F I D 4 1 D C M = d i c h l o r o m e t h a n e 2 I P A = i s o p r o p a n o l 3 A C N = a c e t o n i t r i l e 4 G C - F I D = g a s c h r o m a t o g r a p h y w i t h f l a m e i o n i s a t i o n d e t e c t i o n

SPA sampling at low tar concentrations and separate BTX analysis Determination of light tar in low concentrations Adsorbent for Benzene, Toluene and Xylene (BTX) Pump Flow meter Adsorbent for other compounds Needle Sample inlet

New method for analysis of total tar S a m p lin g S a m p le p r e p a r a t io n G r a v im e t r y T a r is d is s o lv e d in o r g a n ic s o lv e n t s W e ig h in g a f t e r s o lv e n t r e m o v a l G a s c h r o m a t o g r a p h y, G C C a lc u la t io n H e a v y t a r = g r a v im e t r y - G C Heated and isolated T -connection with SPAsepta (left) and heavy tar sampler (right).