Using Alba with the FemtoFiber laser by Toptica for 2-photon quantitative imaging

Similar documents
Imagent for fnirs and EROS measurements

Electronic Supplementary Information

Femtosecond laser microfabrication in. Prof. Dr. Cleber R. Mendonca

Ultrafast Dynamics and Single Particle Spectroscopy of Au-CdSe Nanorods

LABORATORY OF ELEMENTARY BIOPHYSICS

Confocal Microscopy Imaging of Single Emitter Fluorescence and Hanbury Brown and Twiss Photon Antibunching Setup

Electronic Supplementary Information

Time resolved optical spectroscopy methods for organic photovoltaics. Enrico Da Como. Department of Physics, University of Bath

Richard Miles and Arthur Dogariu. Mechanical and Aerospace Engineering Princeton University, Princeton, NJ 08540, USA

Fluorescence Spectroscopy

Microfabricação em materiais poliméricos usando laser de femtossegundos

Behavior and Energy States of Photogenerated Charge Carriers

Supplementary Figure 1 Comparison of single quantum emitters on two type of substrates:

Optical Spectroscopy. Steady State and Time Dependent Fluorescence Measurements. Kai Wen Teng. October 8 th PHYS 403 Fall 2013

A few Experimental methods for optical spectroscopy Classical methods Modern methods. Remember class #1 Generating fast LASER pulses

The solution for all of your

SUPPLEMENTARY INFORMATION 1. MATERIALS AND METHODS

Highly Efficient and Anomalous Charge Transfer in van der Waals Trilayer Semiconductors

Supporting Information. Synthesis, Structural and Photophysical Properties of. Pentacene Alkanethiolate Monolayer-Protected Gold

High Resolution Optical Spectroscopy

Supplemental Materials and Methods

Femtosecond laser applied to biophotonics. Prof. Cleber R. Mendonca

Second-Harmonic Generation Studies of Silicon Interfaces

Application of the EQP and EQS mass spectrometers to time resolved studies in ion beam and plasma processes

Photoluminescence Spectrometer (FLS980)

Harmonic Generation for Photoionization Experiments Christian J. Kornelis Physics REU Kansas State University

Diffuse reflection BBSFG optical layout

Studies of the Spin Dynamics of Charge Carriers in Semiconductors and their Interfaces. S. K. Singh, T. V. Shahbazyan, I. E. Perakis and N. H.

Development of a table top TW laser accelerator for medical imaging isotope production

Fast and Slow Ligand Exchange at the Surface of Colloidal Gold Nanoparticles

Supporting Information

Ultrafast Wavelength Tuning and Scaling Properties of a Noncollinear Optical Parametric Oscillator (NOPO)

Introduction to Fourier Transform Infrared Spectroscopy

Rapid hyperspectral, vibrationally resonant sum-frequency generation microscopy

The Second Half Year 2017 PAL-XFEL Call for Proposals

Diagnostics of Filamentation in Laser Materials with Fluorescent Methods

Enhancement of Exciton Transport in Porphyrin. Aggregate Nanostructures by Controlling. Hierarchical Self-Assembly

P. Lambrev October 10, 2018

χ (3) Microscopic Techniques

1 Mathematical description of ultrashort laser pulses

Chem 681: Student Seminar Series. Two-Photon Induced Fluorescence

Pulsed lasers. To induce new chemistry, different from that initiated by conventional sources

APPLICATION NOTE. Supercontinuum Generation in SCG-800 Photonic Crystal Fiber. Technology and Applications Center Newport Corporation

Tracking Iodide and Bromide Ion Segregation in Mixed Halide Lead Perovskites during Photoirradiation

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

Figure 1. Decay Scheme for 60Co

Introduction to Fourier Transform Infrared Spectroscopy

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Time-resolved spectroscopy

Laboratory 3: Confocal Microscopy Imaging of Single Emitter Fluorescence and Hanbury Brown, and Twiss Setup for Photon Antibunching

TIME-RESOLVED OPTICAL SPECTROSCOPY

High photostability and enhanced fluorescence of gold nanoclusters by silver doping-supporting information

SUPPLEMENTARY INFORMATION

Facile and purification-free synthesis of nitrogenated amphiphilic graphitic carbon dots

University of Groningen. Laser Spectroscopy of Trapped Ra+ Ion Versolato, Oscar Oreste

SUPPLEMENTARY INFORMATION

Supplemental material for Bound electron nonlinearity beyond the ionization threshold

SIZE-SELECTED AEROSOL FILTER ANALYSIS USING ELECTROSTATIC CLASSIFICATION AND LIBS

STM: Scanning Tunneling Microscope

Dual-Wavelength Lasing from Organic Dye Encapsulated Metal-Organic Framework Microcrystals

Fluorescence Spectroscopy

Industrial Applications of Ultrafast Lasers: From Photomask Repair to Device Physics

Boosting Transport Distances for Molecular Excitons within Photo-excited Metal Organic Framework Films

Carrier dynamics of rubrene single-crystals revealed by transient broadband terahertz

Lecture 11, May 11, 2017

Optics and Spectroscopy

Supporting Information: Ultrafast Excited State Transport and Decay Dynamics in Cesium Lead Mixed-Halide Perovskites

Supplementary Materials

Introduction to FCS. Enrico Gratton. Laboratory for Fluorescence Dynamics Department of Biomedical Engineering University of California, Irvine

PD300 PD300-1W PD300-3W PD300-TP

Time and space resolved spectroscopy of nanoenergetic materials Dana Dlott

SUPPORTING INFORMATION: Titanium Contacts to Graphene: Process-Induced Variability in Electronic and Thermal Transport

Optoelectronic Applications. Injection Locked Oscillators. Injection Locked Oscillators. Q 2, ω 2. Q 1, ω 1

Nonlinear Optics (WiSe 2015/16) Lecture 12: January 15, 2016

PH300 Spring Homework 06

Federal University of São Carlos Physics Department. Time Resolved Measurement System MUE: 2014/

Lecture 9. PMTs and Laser Noise. Lecture 9. Photon Counting. Photomultiplier Tubes (PMTs) Laser Phase Noise. Relative Intensity

Supplementary Information

Resonantly Pumped Er:YAG and Er:YAP Lasers

Anti-Bunching from a Quantum Dot

Measurement Examples. Excitation and Emission Scans. Steady State Fluorescence Anisotropy. Kinetic Measurements

Title: Ultrafast photocurrent measurement of the escape time of electrons and holes from

Survey on Laser Spectroscopic Techniques for Condensed Matter

Optical Frequency Comb Fourier Transform Spectroscopy with Resolution beyond the Path Difference Limit

Selected measurements with FluoTime 300

PC Laboratory Raman Spectroscopy

Transient Thermal Measurement and Behavior of Integrated Circuits

stabilized 10-fs lasers and their application to laser-based electron acceleration

XR Analog Clock - Manual Setting Model Troubleshooting Guide

Simple strategy for enhancing terahertz emission from coherent longitudinal optical phonons using undoped GaAs/n-type GaAs epitaxial layer structures

Overview of X-Ray Fluorescence Analysis

Advanced Spectroscopy Laboratory

A Straight Forward Path (Roadmap) to EUV High Brightness LPP Source

Temperature-dependent spectroscopic analysis of F 2 + ** and F 2 + **-like color centers in LiF

Technology, Techniques and Applications. Ric Allott Business Development Manager

Small Signal Gain in DPAL Systems

Parametric down-conversion

Single Emitter Detection with Fluorescence and Extinction Spectroscopy

Single Microwave-Photon Detector based on Superconducting Quantum Circuits

Energy transport in metal nanoparticle plasmon waveguides

Transcription:

TECHNICAL NOTE Using Alba with the FemtoFiber laser by Toptica for 2-photon quantitative imaging Shih-Chu Liao, Yuansheng Sun, Ulas Coskun ISS, Inc. Introduction The advantages of multiphoton excitation for quantitative cell biology are numerous: reduced phototoxicity as excitation occurs in the range from 700 nm to 950 nm (or longer), femtosecond pulses, reduced excitation volume. Yet the cost of standard multiphoton lasers is sometimes out of the range for several research laboratories. Toptica Photonics (Graefelfing, Germany; Victor, NY) offers a family of ultrafast fiber lasers. Two systems feature dual wavelength output from the single unit. The new Dichro biomp laser emitting two wavelengths, 780 nm and 1030 nm and the virtual 888nm, is suitable for two-photon laser excitation (see Table I). The FemtoFiber Pro NIR emits 780 nm and 1560 nm (Table I). Wavelengths [nm] 780 1030 Model: Dichro biomp Laser output power [mw] >100 >200 Pulse width [fs] <100 Repetition rate 80 MHz Beam Shape TEM00, M 2 < 1.2 Wavelengths [nm] 780 1560 Model: FemtoFiber pro NIR Laser output power [mw] >150 >350 Pulse width [fs] <100 Repetition rate 80 MHz Beam Shape TEM00, M 2 < 1.2 Table I. Features of FemtoFiber laser family. The measurements reported in this Note were acquired using the FemtoFiber Pro NIR laser. In fact, several probes are available for the fundamental 780 nm wavelength. Instrument Setup The system optical setup is shown below. The laser beam is sent into the excitation head of the Alba (Figure 1) by using a periscope; the intensity of the 2p laser into Alba is controlled using the Intensity Control Unit (ISS part no. 1 ISS TECHNICAL NOTE

A450) featuring a halfwave plate and a Glan-Thompson laser polarizer; the laser intensity can be tuned continuously from less than 0.1 mw to more than 100 mw. In the Alba, a 720-nm long pass dichroic (D1) is used to separate the 780-nm laser excitation and the emission in the visible range; a 720-nm short pass emission filter is used as an IR blocking (IRB) filter. The Alba is equipped with two Hamamatsu H7422P-40 photomultiplier tubes detectors. Figure 1. Schematics of the instrument. FCS Measurements Fluorescence Correlation Spectroscopy (FCS) measurements were carried out on a solution of Fluorescein (ph 7.4) at different concentrations ranging from 1 nm to 200 nm. The microscope (Model Ti by Nikon) is equipped with a 60X (1.2 NA) water immersion objective. A bandpass filter (525 ± 20 nm) is placed in front of the detector. The Laser power measured before entering the Alba is 20 mw. Figure 2. FCS curves for the 1.5-200 nm concentration solutions 2 ISS TECHNICAL NOTE

The auto correlation functions were fitted with the Gaussian Lorentz 1 species model, giving the lateral dimension (w0) to be 289 nm; while the axial / lateral (z0 / w0) ratio by assuming the 3D Gaussian shape was estimated to be 4.56. The experimental results obtained with the Gaussian Lorentz fit are reported in Table II below. They were determined by fixing the value of the diffusion coefficient to 430 µm 2 s -1 ; the concentrations of the solutions were retrieved by the fitting procedure using VistaVision software. Parameter 1 2 3 4 D, um^2/s 430 430 430 430 C (nm) 1.47 9.97 49.9 232 w0 (µm) 0.289 0.289 0.289 0.289 TauD (µs) 24.2 24.2 24.2 24.2 N, # 0.0247 0.168 0.839 3.89 G 1.12 0.167 0.0319 0.007 G(0) 2.76 0.406 0.0811 0.018 ExcVol (µm 3 ) 0.028 0.028 0.028 0.028 CPS 1940 15000 68900 3E+05 Chi-Sq 0.857 0.459 0.391 0.409 Table II. Fitting results of the FCS curves for the 1.5-200 nm concentration solutions FLIM Measurements FLIM measurements were acquired using the Alba equipped with the FastFLIM data acquisition. For calibration, two lifetime standards were used, a solution of Fluorescein in buffer at ph 7.4 and a solution of Coumarin 6 in Ethanol. The lifetime data for the two solutions are displayed on the polar plot in Figure 3: 2.56 ns was obtained for the Coumarin and 4 ns for the Fluorescein. Figure 3. Phasor plot of the fluorescence lifetime data of fluorescein in buffer at ph 7.4 and Coumarin 6 in Ethanol. 3 ISS TECHNICAL NOTE

FLIM data were acquired on a slide with Lily Convallaria (Figure 4). Figure 4. Intensity image (left) and lifetime image (right). Image size is 1024x1024 (100 µm x 100 µm). A stack of FLIM measurements (3D FLIM) measurements was acquired using a slide with pollen (Figure 5). Figure 5. Volume rendering of intensity images (left) and of lifetime images (right), Stability Test The FemtoFiber Pro NIR laser unit provides a clock out signal for the laser pulse reference. With a 50Ω termination, the laser clock reference is a clean negative NIM signal with the peak amplitude of -200mV and a FWHM of less than 2ns. The clock out signal is first amplified by a 36-dB preamp and the amplified signal is given to the FastFLIM clock in for synchronization, required by FLIM measurements. A stable laser reference clock is critical for a robust timelapse FLIM measurement. To test the stability, time-lapse FLIM measurements of fluorescein (ph7.4) were carried out: 4 ISS TECHNICAL NOTE

Figure 6. 2760 time points over 8 hours, data accumulation time per time point, 10 seconds: both the laser intensity and the reference clock are quite stable Conclusions Alba V combined with the Toptica FemtoFiber Pro laser (780 nm) provides high-sensitivity and time-resolved 2p imaging capability, and is ready for advanced FLIM and FFS (FCS, PCH) measurements. The results obtained with the FemtoFiber Pro laser are comparable to those obtained with commercial Ti:Sapphire 2p lasers operating at the same wavelength. The reference clock of the FemtoFiber Pro laser is more stable than the clock of the Ti:Sapphire lasers. For more information please call (217) 359-8681 or visit our website at www.iss.com 1602 Newton Drive Champaign, Illinois 61822 USA Telephone: (217) 359-8681 Fax: (217) 359-7879 Email: iss@iss.com Copyright 2015 ISS Inc. All rights reserved, including those to reproduce this article or parts thereof in any form without written permission from ISS. ISS, the ISS logo are registered trademarks of ISS Inc. 5 ISS TECHNICAL NOTE