Topics in Solid-Phase Extraction

Similar documents
A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Strategies for the Analysis of Therapeutic Peptides in Biofluids by LC-MS/MS. Lee Goodwin

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

[ Care and Use Manual ]

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

Sample Prep Options for GC users

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

Determination of Pharmaceuticals in Environmental Samples

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Thiabendazole (TBZ) and benomyl are benzamidazolic

A New Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Presentation Basic Introduction to Instrumentation Matrix Effects Challenges

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Chapter content. Reference

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

penta-hilic UHPLC COLUMNS

Solid Phase Extraction Method Development Tips and Tricks

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Introduction to Pharmaceutical Chemical Analysis

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Introduction. Chapter 1. Learning Objectives

CHAPTER 1 Role of Bioanalytical Methods in Drug Discovery and Development

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Sample Preparation. Approaches to Automation for SPE

Routine MS Detection for USP Chromatographic Methods

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Shodex TM ODP2 HP series columns

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Dilution(*) Chromatography

Glyphosate in all its forms

penta-hilic UHPLC COLUMNS

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis

Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation

PosterREPRINT COMPARISON OF PEAK PARKING VERSUS AUTOMATED FRACTION ANALYSIS OF A COMPLEX PROTEIN MIXTURE. Introduction

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Identification of Human Hemoglobin Protein Variants Using Electrospray Ionization-Electron Transfer Dissociation Mass Spectrometry

Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Peptide Isolation Using the Prep 150 LC System

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Effects of Aqueous Sample Content and Aqueous Co-Solvent Composition on UPC 2 Separation Performance

Abstract. Experimental Sample Preparation

Guide to Peptide Quantitation. Agilent clinical research

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Simplify Sample Preparation [ SAMPLE PREPARATION SOLUTIONS ]

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

ikey Separation Device

Choosing the metabolomics platform

LC-MS/MS in the Clinical Laboratory. Jo Adaway

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

ImprovIng ADmE ScrEEnIng productivity In Drug DIScovEry

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

Ion Suppression: A Major Concern in Mass Spectrometry

High Performance Liquid Chromatography

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges

Choosing Fit-For-Purpose Food Safety Methods

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120

TR ACE ORGANIC. lgcstandards.com/foodandenvironment

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA).

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

HPLC Determination of Antidepressants and their Metabolites in Plasma

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Definitive EtG/EtS LC-MS/MS Analysis:

A Sensitive and Reproducible Signature Peptide MRM Based Quantitation Method for Pegylated Interferon α-2b in Serum

Electronic Supplementary Information. The selective response of templated polymer for the cationic drug

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Chromatographic Methods: Basics, Advanced HPLC Methods

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9.

Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS

UPC 2 Strategy for Scaling from Analytical to Preparative SFC Separations

Non-Interfering Protein Assay Kit Cat. No

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Transcription:

Topics in Solid-Phase Extraction Part 1. Ion Suppression in LC/MS Analysis: A Review Strategies for its elimination by well-designed, multidimensional solid-phase extraction [SPE] protocols and methods for its quantitative assessment. Waters Corporation, 34 Maple Street, Milford, Massachusetts, 01757-3696 USA 508-478-2000 Fax: 508-872-1990 www.waters.com For Chemistry Confidence

Topics in Solid-Phase Extraction Part 1. Ion Suppression in LC/MS Analysis: A Review Strategies for its elimination by well-designed, multidimensional solid-phase extraction [SPE] protocols and methods for its quantitative assessment. Background Over the last decade, the combination of high-performance liquid chromatography and mass spectrometry has become the most important tool in many fields, especially when a determination of specific analytes in a complex matrix needs to be performed. Examples are the analysis of drugs and their metabolites in biological fluids, especially blood and urine, and the measurement of residual contaminants in food matrices or in the environment. The reason for this widespread acceptance is the high selectivity and high sensitivity of MS techniques that permit the detection of very low levels of target analytes in the presence of a complex matrix background. However, experience has taught that, while detection is no longer an obstacle, quantitative determination of the species of interest may be problematic 1. If a significant background is present, the signals for the analytes of interest are often suppressed. The magnitude of this suppression may vary from sample to sample 1. Thus, one cannot rely upon the results of an analysis with a high level of ion suppression 2. Steps must be taken prior to analysis to minimize or eliminate ion suppression effects via sample clean-up techniques 3. The detailed causes of ion-suppression are not clear and, apparently, can be manifold 4. Even commonly used mobile phase components such as trifluoroacetic acid cause ion suppression. Of course, the presence of a complex matrix amplifies the problem 5. This is not only true for plasma 1 or urine 6 samples, but also in the analysis of food samples such as cattle or fish tissues 7, fruits and vegetables 8,9, or environmental water 10,11. In all these cases, the investigator needs to be concerned about the inaccuracy of the analytical results caused by matrix interferences. Procedures have been established to quantitate matrix effects 12, and the authors of this study have strongly advocated the measurement and elimination of such effects. Only then can one avoid significant errors in the analytical results. For some period of time, it was believed that the use of isotopically labeled internal standards could be a simple solution to the ion-suppression problem. However, it has been demonstrated that this is not the case. Jemal et al. 13 showed that under certain conditions the use of an isotopically labeled standard does not guarantee the constancy of the analyte/internal response ratio. Liang et al. 14 demonstrated that isotope-labeled standards either enhance or suppress the response of the analyte, depending on the ionization technique. Enhancement was found in atmospheric pressure chemical ionization, and suppression in electrospray ionization. While the use of isotopically labeled standards may be helpful, it is certainly not a definitive solution to matrix interference problems. Elimination of matrix-induced ion suppression requires removal of extraneous matrix components via a high-quality sample cleanup. In this paper we will discuss this subject in more detail. Methods of Sample Preparation To be analyzed by HPLC, a sample must be in a liquid state, and the liquid should be free of solids. So, some sample preparation is unavoidable for nearly all samples, even for standards. Samples with very low analyte concentration(s) often require enrichment. Sample enrichment is most conveniently carried out using a solid-phase extraction [SPE] procedure, as was done, for example, in reference 15 for the determination of sulfonylurea herbicides in environmental water and soil. In addition, complex samples require, at a minimum, the removal of sample components that can clog, or accumulate as contaminants on, the HPLC column. A multitude of sample clean-up techniques are available, but they differ in their efficiency of interference removal and in their convenience of use. In addition, they are often specific to the sample matrix, since different matrices contain different components that need to be removed. Let us consider blood plasma as an example. Major constituents here are plasma proteins, sugars, salts, lipids, and a myriad of peptides and small molecules. Sample preparation protocols for plasma range from simple protein precipitation to efficient solid-phase or liquid-liquid extraction methods. Let us discuss the advantages and disadvantages of these techniques. Protein precipitation is carried out by simply adding a large proportion of acetonitrile to the sample usually, a ratio of three to four volumes of acetonitrile to one volume of plasma. A lower ratio leads to insufficient protein precipitation. A larger ratio dilutes the sample too much. Because of its simplicity, this procedure remains a popular technique in 2

blood analysis. However, as its name implies, the only type of contaminant that protein precipitation removes is protein. Other components of the plasma metabolome, e.g., phospholipids, remain and cause ion suppression when such samples are analyzed via LC/MS. In contrast, liquid-liquid extraction [LLE], often, creates rather clean extracts, but the procedure is cumbersome and has many pitfalls. In order to transfer an ionizable analyte into the organic extraction solvent, it first needs to be converted in its aqueous medium to a non-ionic form, using either high or low ph. This procedure is not suitable for compounds which have both positively and negatively chargeable groups. Next, a suitable solvent needs to be found that efficiently and preferentially extracts the analyte. However, even if an appropriate solvent is found, a single step rarely extracts the analyte quantitatively; multiple extraction steps are commonly needed. Alternatively, if one relies only on a partial extraction, the reproducibility of this step must be ensured with an internal standard that has extraction properties very similar to those of the analyte. Preferentially, a deuterated standard should be used 16. Often, a second extraction back into the aqueous medium (for example at a different ph) completes the sample preparation, with the same difficulties as those associated with the first step. Another issue with LLE is its unsuitability for automation. Manual LLE is often carried out with rather large solvent volumes, making it much less desirable for the analysis of blood samples. Clearly, the disadvantages of LLE are significant. Solid-phase extraction solves the problems of both protein precipitation and LLE. Compared to LLE, it can be scaled down readily to sample volumes below 50 µl 17, and it can be automated easily 18. SPE is usually carried out off-line using single cartridges or in 96-well plates 17, but it can also be realized online with the HPLC separation, using switching valves to direct the flow either to waste or to the HPLC column 19. Compared to protein precipitation, SPE has the advantage that much more specific protocols can be generated that permit very selective sample cleanup. Thus, the problem of matrix ion suppression can always be solved using an appropriate solid-phase extraction method. A discussion of the details of such protocols follows. Solid-phase Extraction Protocols Multiple generic SPE protocols have been developed and demonstrated 3. In general, the best cleanup results are obtained by using a sample preparation method that is orthogonal to the LC separation mode. Orthogonal methods, sometimes called two-dimensional [2-D] methods, use two completely different modes of separation or retention to improve separation power dramatically. As an example, if sample preparation is followed by a reversed-phase HPLC separation, then, the most selective SPE methods rely on ionic [ion exchange] interactions. Of course, this requires that analyte(s) have an ionizable function, but this is the case for most pharmaceuticals, and, often, for analytes of interest in other fields. Keeping in mind that other techniques or combinations thereof may be more suitable for a particular problem, here we will first focus on combining ion-exchange SPE with reversed-phase HPLC in tandem with MS detection. A sample preparation method of this type is outlined in Figures 1 and 2. Let us assume that the analyte, like a large number of pharmaceuticals, contains a basic amino functional group [Figure 1]. The sample matrix is blood plasma, of either animal or human origin. We will use an Oasis Mixed-Mode Cation Exchanger [Oasis MCX] to prepare the sample. Under acidic conditions, our protonated analyte, being positively charged, will be retained on this cartridge. Therefore, we acidify our plasma sample, add an internal standard with molecular properties similar to those of our analyte, and load this solution onto a properly prepared Oasis MCX cartridge. The analyte and internal standards bind to the ion-exchange cartridge. Very polar neutral and anionic components of the sample are washed through the Oasis cartridge, as are higher molecular weight components of the sample such as proteins, due to size exclusion and slow mass transfer. To completely remove these sample High ph Oasis MCX Elution Scheme for Basic Analytes 3 Elute Analytes Principles for cleanup and analysis of blood samples may be applied to other sample matrices. For example, today, the enrichment of trace contaminants in environmental water is preferentially carried out using a solid-phase extraction technique 11,15. Similar methodologies can be applied to human urine samples 20 or fruit juices 8,21. As pointed out above, the concern about ion suppression is universal and independent of the sample matrix 7,9,10,11. Low ph Figure 1 1 Remove 2 Remove Polar Non-polar Low Organic High Organic 3

components, the first wash solution contains an acidified, largely aqueous solution. A second wash with methanol elutes neutral compounds that had been retained via hydrophobic retention on the mixed-mode sorbent. However, very hydrophobic components of the sample matrix, e.g., some lipids, will remain on the sorbent. In the final step, the desired analyte and the internal standard are eluted with 5% ammonia in methanol. For acidic analytes, the protocol can be inverted [Figure 2]. Base is added to the sample to adjust its ph to a high value. Under these circumstances, acidic analytes are ionized and retained on an Oasis Mixed-Mode Anion Exchange cartridge [Oasis MAX]. The first wash at alkaline ph removes polar and cationic compounds, analogous to the acidic wash on the Oasis MCX cartridge. Similarly, a second wash with methanol removes less polar, hydrophobically bound compounds. Finally, the acidic analytes are neutralized and eluted with a methanol solution acidified using either formic acid or a stronger acid such as HCl. between protein precipitation and the recommended 2-D SPE method was 50-fold! This demonstrates unequivocally the magnitude of, and an excellent solution to, the ion-suppression problem. 100 % 16 100 % 7 100 % Figure 3 Protein Precipitation 1 ng/ml Simple SPE Protocol 1 ng/ml Oasis MCX Protocol 1 ng/ml Propranolol 3.8 min MRM of 2 Channels ES+ 259.9 > 154.9 Area: 278 MRM of 2 Channels ES+ 259.9 > 154.9 Area: 1,329 MRM of 2 Channels ES+ 259.9 > 154.9 Area: 13,534 2 0 1 2 3 4 5 min High ph Low ph Figure 2 1 Remove 2 Remove Polar Non-polar Oasis MAX Elution Scheme for Acidic Analytes Low Organic Elute Analytes This protocol delivers excellent results, both with respect to recovery and sample cleanup. Figure 3 shows a comparison of the results obtained from a standard protein precipitation, a simple onedimensional [1-D] SPE protocol relying solely on the reversed-phase interaction of a neutral analyte with a hydrophobic SPE sorbent, and the 2-D sample cleanup and elution using the Oasis MCX cartridge protocol just described 17. At a sample concentration of 1 ng/ml, the respective peak areas for propranolol, the basic compound eluting at 3.8 minutes, were 278 with protein precipitation, 1,329 with simple on/off 1-D hydrophobic SPE, and 13,534 for the method combining 2-D SPE sample cleanup with reversed-phase HPLC/MS. Thus, the straightforward, yet sophisticated, SPE method described in the last two paragraphs gave 10-fold less suppression than the simple on/off 1-D SPE method, which, in turn, was about a 5-fold improvement over protein precipitation. In this example, the net reduction in ion suppression 3 High Organic It is a fallacy to assume that the ion-suppression problem can be obviated by using an internal standard. An identical protocol, executed with the analyte amitriptyline, gave, within experimental error, the same response for both a standard solution and for a plasma sample prepared by the mixed-mode SPE protocol, demonstrating both complete recovery and the elimination of ion suppression. For a corresponding protein precipitation sample cleanup, the response was nearly 5 times lower than that for the neat sample. Thus, LC/MS data for propranolol determination in a sample prepared via protein precipitation using amitriptyline as the internal standard would have underestimated the level of amitriptyline roughly 10-fold an intolerable error for quantitative analysis of a drug in plasma! This reinforces the strong recommendations by Matuszewski et al. 12 on how to carry out properly quantitative bioanalytical methods and how to measure ion suppression or avoid sample preparation errors. Good sample preparation is not only necessary for blood samples in the pharmaceutical industry. It is also required in food analysis 7. As an example of an elegant sample clean-up procedure, the analysis of a fluoroquinolone antibiotic in beef kidney will be described 22. Fluoroquinolone antibiotics have been approved since 1995 for use in animal husbandry. For the analysis of enrofloxacin in beef kidney, ciprofloxacin was the internal standard. These compounds are amphoteric; they can be selectively extracted and cleaned up using a combination of anion exchange and cation exchange [Figure 4]. Homogenized kidney was diluted with buffer. After addition of the internal standard and ultracentrifugation, the resulting fluid was then subjected to the standard protocol for the Oasis MAX cartridge. Conditioned in base, the cartridge retained the anionic and amphoteric species by ion 4

exchange and the cationic and neutral interferences by a reversed-phase mechanism. The latter species were washed off with methanol. In the final step, 0.2N HCl in methanol eluted the amphoteric analytes. This acidified eluent was loaded directly onto an Oasis MCX cartridge. Acidic interferences passed through unretained; less polar neutral species eluted in the intermediate methanol wash. The final basic eluate contained only zwitterionic compounds with properties similar to those of the fluoroquinoline antibiotics. This cleanup procedure delivered a sample that was even clean enough for an analysis with UV or fluorescence detection! Of course, MS/MS detection permitted the determination of the residual content of the antibiotic at still lower concentrations [Figure 4]. Such elegant sample preparation procedures can completely eliminate ion-suppression issues, even from samples in complex matrices. Similarly well-designed sample preparation techniques have been used for the determination of acrylamide in fried potato products 23. second sample set consists of five different lots of sample matrix [plasma or urine] to which blank mobile phase is added. The third sample set is made up of the same five sample matrix samples as in set two, except, instead of blank mobile phase, the analyte-in-mobile-phase solutions are added. Now sample sets 2 and 3 are subjected to the same sample preparation technique. Finally, analytes are added to sample set 2 after the sample preparation step, and all three sample sets are analyzed. The comparison of sample set 1 and sample set 2 permits the calculation of the matrix effect (ME%) from the ratio of corresponding responses from sample set 2 to those of sample set 1. Similarly, the recovery of the sample preparation procedure (RE%) is calculated from the ratio of sample set 3 to sample set 2. In addition, the use of five different sample sources permits an estimate of the influence of source variability on the results. For example, different diets for, or metabolism variation of, the subjects under investigation can influence matrix suppression and yield incorrect results. Methods have also been established to measure ion-suppression effects directly in the chromatographic method via post-column infusion 24,25,26. Here, the HPLC analysis is carried out on a blank matrix sample with MS detection. Prior to the MS inlet, a second stream carrying the analyte(s) is added to the column effluent. The MS system monitors the signal for the analytes over time. For those regions in the chromatogram that suffer from ion suppression (or the more rare event of ion enhancement), the signal of the analyte(s) differs from the signal obtained with straight mobile phase. This permits a direct, qualitative measurement of ion suppression or enhancement and leads investigators to the best sample preparation or chromatographic technique for their analytical problem. Figure 4 Methods for Measuring Ion Suppression To compare different sample preparation techniques for the analysis of drugs in biological fluids, Matuszewski et al. 12 proposed a specific protocol that permits the determination of the reduction of matrix effects (ME%), recovery of the sample preparation procedure (RE%) and the overall process efficiency (PE%), which is the product of the matrix effect and the recovery. The desired values are 100% in all cases, indicating the absence of matrix suppression and complete recovery of the analytes of interest after the sample preparation process. The protocol requires three sets of experiments which generate three sets of samples. The first set of five samples is prepared by dissolving the analytes in mobile phase. The Summary Ion suppression a common phenomenon in the LC/MS analysis of complex samples can be effectively eliminated by good solid-phase extraction methods. Today, with tools such as SPE, coupled with the availability of methods for the quantitative assessment of ion suppression, significant errors in LC/MS analysis due to ion suppression are avoidable and inexcusable. Uwe D. Neue and Patrick D. McDonald 5

References: 1. B. K. Matuszewksi, M. L. Constanzer, C. M. Chavez-Eng, Matrix Effect in Quantitative LC/MS/MS Analyses of Biological Fluids: A Method for Determination of Finasteride in Human Plasma at Picogram Per Milliliter Concentrations, Anal. Chem. 70 (1998), 882-889 2. P. R. Tiller, L. A. Romanyshyn, Implications of matrix effects in ultra-fast gradient or fast isocratic liquid chromatography with mass spectrometry in drug discovery, Rapid Commun. Mass Spectrom. 16 (2002), 92-98 3. U. D. Neue, C. R. Mallet, Z. Lu, Y.-F. Cheng, J. R. Mazzeo, Techniques for Sample Preparation Using Solid-Phase Extraction, Handbook of Analytical Separations Vol. 4, pp. 73-90, I. D. Wilson ed., Elsevier Science, 2003 4. C. R. Mallet, Z. Lu, J. R. Mazzeo, A study of ion suppression effects in electrospray ionization from mobile phase additives and solid-phase extracts, Rapid. Commun. Mass Spectrom. 18 (2004), 49-58 5. P. R. Tiller, L. A. Romanyshyn, U. D. Neue, Fast LC/MS in the analysis of small molecules, Analytical and Bioanalytical Chemistry 377 (2003), 788-802 6. M. L. Constanzer, C. M. Chavez-Eng, I. Fu, E. J. Woolf, B. K. Matuszewski, Determination of dextromethorphan and its metabolite dextrorphan in human urine using high performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry: a study of selectivity of a tandem mass spectrometric assay, J. Chromatogr. B 816 (2005), 297-308 7. S. Bogialli, R. Curini, A. Di Corcia, M. Nazzari, R. Samperi, A Liquid Chromatography Mass Spectrometry Assay for Analyzing Sulfonamide Antibacterials in Cattle and Fish Muscle Tissues, Anal. Chem. 75 (2003), 1798-1804 8. M. S. Young, M. F. Early, C. R. Mallet, J. Krol, Application of a mixed-mode solid-phase extraction and cleanup procedure for LC/MS determination of thiabendazole and carbendazim in apple juice, J. AOAC Int. 84 (2001), 1608-1613 9. I. Ferrer, J. F. García-Reyes, M. Mezcua, E. M. Thurman, A. R. Fernández-Alba, Multiresidue pesticide analysis in fruits and vegetable by liquid chromatography time-of-flight mass spectrometry, J. Chromatogr. A 1082(1) (2005), 81-90 10. A. Kloepfer, J. B. Quintana, T. Reemtsma, Operational options to reduce matrix effects in liquid chromatography electrospray ionization mass spectrometry analysis of aqueous environmental samples, J. Chromatogr. A 1067 (2005), 153-160 11. R. Rodil, J. B. Quintana, T. Reemtsma, Liquid Chromatography Tandem Mass Spectrometry Determination of Nonionic Organophosphorous Flame Retardants and Plasticizers in Wastewater Samples, Anal. Chem. 77 (2005), 3083-3089 12. B. K. Matuszewksi, M. L. Constanzer, C. M. Chavez-Eng, Strategies for the Assessment of Matrix Effect in Quantitative Bioanalytical Methods Based on HPLC-MS/MS, Anal. Chem. 75 (2003), 3019-3030 13. M. Jemal, A. Schuster, D. B. Whigan, Liquid Chromatography/tandem mass spectrometry methods for quantitation of mevalonic acid in human plasma and urine: method validation, demonstration of using a surrogate analyte, and demonstration of unacceptable matrix effect in spite of use of a stable isotope internal standard, Rapid Commun. Mass Spectrom. 17 (2003), 1723-1734 14. H. R. Liang, R. L. Foltz, M. Meng, P. Bennett, Ionization enhancement in atmospheric pressure chemical ionization between target drugs and stable-isotope-labeled internal standards in quantitative liquid chromatography/tandem mass spectrometry, Rapid Commun. Mass Spectrom. 17 (2003), 2815-2821 15. M. S. Young, Preparation of Environmental Samples for Determination of Sulfonylurea Herbicides by Solid-Phase Extraction Using a Polymeric Sorbent, J. AOAC Int. 81 (1998), 99-104 16. W. Li, Y.-H. Li, A. C. Li, S. Zhou, Weng Naidong, Simultaneous determination of norethindrome and ethinyl estradiol in human plasma by high-performance liquid chromatography with tandem mass spectrometry experiences on developing a highly selective method using derivatization reagent for enhancing sensitivity, J. Chromatogr. B (2005), in press. 17. C. R. Mallet, Z. Lu, R. Fisk, J. R. Mazzeo, U. D. Neue, Performance of an ultra-low-elution-volume 96-well plate: drug discovery and development applications, Rapid Commun. Mass Spectrom. 17 (2003), 163-170 18. a. R. Fisk, J. Belanger, P. Iraneta, S. Serpa, Z. Lu, C. Mallet, J. Mazzeo, U. Neue, Y.-F. Cheng, High-Throughput High-Sensitivity Oasis Elution Technology, LC-GC Europe, The Applications Book, April (2003), 27-28; pdf available on http://www.waters.com: Click on Library, then Search Posters and Technical Presentations, & use keyword WA30754 b. R. Fisk, J. Belanger, P. Iraneta, S. Serpa, Z. Lu, C. Mallet, J. Mazzeo, U. Neue, Y.-F. Cheng, High-throughput high-sensitivity Oasis elution technology, LC-GC North America 21 (2003) Supplement, 22-23 19. C. R. Mallet, J. R. Mazzeo, U. D. Neue, Evaluation of several solid phase extraction liquid chromatography/tandem mass spectrometry on-line configurations for high-throughput analysis of acidic and basic drugs in rat plasma, Rapid Commun. Mass Spectrom. 15 (2001), 1075-1083 20. K. M. Jenkins, M. S. Young, C. R. Mallet, A. A. Eilan, Mixed-mode solid-phase extraction procedures for the determination of MDMA and metabolites in urine using LC-MS, LC-UV or GC-NPD, J. Anal. Toxicol. 28 (2004), 50-58 21. M. S. Young, D. J. Phillips, P. C. Iraneta, J. Krol, Mixed-mode solid-phase extraction and cleanup procedures for the liquid chromatographic determination of thiabendazole and carbendazim in fruit juices, J. AOAC Int. 84 (2001), 556-561 22. K. M. Jenkins, M. S. Young, presentation at the Fall ACS 2003, AGRO Division; pdf available on http://www.waters.com: Click on Library, then Search Posters and Technical Presentations, & use keyword WA31770 23. M. S. Young, K. M. Jenkins, C. R. Mallet, Solid-Phase Extraction and Cleanup Procedures for Determination of Acrylamide in Fried Potato Products by Liquid Chromatography / Mass Spectrometry, J. AOAC Int. 87 (2004), 15 24. Weng Naidong, T. D. J. Halls, Biopharm 49, Jan 2002, 22-26 25. C. Miller-Stein, R. Bonfiglio, T. V. Olah, R. C. King, Am. Pharm. Rev. 3 (2000), 54 26. M. Wood, M. Laloup, N. Samyn, M. R. Morris, E. A. de Bruijn, R. A. Maes, M. S. Young, V. Maes, G. De Boek, Simultaneous analysis of gamma-hydroxybutyric acid and its precursors in urine using liquid chromatography tandem mass spectrometry, J. Chromatogr. A 1056 (2004), 83-90 2005 Waters Corporation. Waters and Oasis are registered trademarks of Waters Corporation. All other trademarks are acknowledged. 720001273EN