columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Similar documents
Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode WCX-1

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

for Acclaim Trinity TM P1

ColumnsAcclaim PolarAdvantage II (PA2) HPLC Columns

columns IonPac AS22 Anion-Exchange Column

columns IonPac AS17-C Anion Exchange Column

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

for Acclaim Mixed-Mode HILIC-1 Column

Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by HPLC Using a Mixed-Mode Weak Anion-Exchange Column

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Acclaim Mixed-Mode WAX-1 Columns

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Comparison of different aqueous mobile phase HPLC techniques

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

Acclaim HPLC and UHPLC Columns

columns IonPac SCS 1 Silica Cation Separator

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

penta-hilic UHPLC COLUMNS

New Developments in Surfactant Analysis Using HPLC

HILIC Method Development in a Few Simple Steps

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

penta-hilic UHPLC COLUMNS

A Platform Method for Pharmaceutical Counterion Analysis by HPLC

LC Columns with Liquid Separation Cell Technology

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

[ Care and Use Manual ]

columns IonPac AS18 Anion-Exchange Columns

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Packings for HPLC. Packings for HPLC

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Thermo Scientific Acclaim. Catalogue 9. Hichrom Limited

Determination of Additives in Carbonated Beverages

Acclaim HPLC and UHPLC Columns

Liquid Chromatography

Too Polar for Reversed Phase What Do You Do?

Evolution of Mixed-Mode

anion-exchange column

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Acclaim AmG C18 Column

State-of-the-art C18 HPLC Columns

Advantages of polymerbased. an alternative for ODS

Method Development Kits

Alltech Alltima HP Introduction

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Thermo Scientific. Anion-Exchange Column

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System

ANALYSIS OF BASIC COMPOUNDS

The column name corresponds to ph value of the mobile phase where acid residue on the column switches from ionize form to neutral one.

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

Acclaim HILIC-10 Columns

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

HPLC Column Classification

It s hot! ZIC -chilic

Easy Method Transfer from HPLC to RSLC with the Dionex Method Speed-Up Calculator

8. Methods in Developing Mobile Phase Condition for C18 Column

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

LC and LC/MS Column Selection Flow Chart

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

Choosing Columns and Conditions for the Best Peak Shape

Technical Guide Thermo Scientific Syncronis HPLC Columns

William E. Barber, Ph.D. Applications Chemist October

Passion. Power. Productivity.

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

LC Technical Information

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Hillel K. Brandes and David S. Bell Supelco, Liquid Separations, Bellefonte PA T GIH

State - of - the -art C18 HPLC Columns

Method Development with ZirChrom's Ion Exchange Phases

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

ProPac WCX-10 Columns

High Performance Liquid Chromatography

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

ACE Ultra Inert Base Deactivated HPLC Columns

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

UPLC Method Development and Validation

Transcription:

columns Acclaim Mixed-Mode WCX- for Separating Basic Molecules The Acclaim Mixed-Mode WCX- is a novel, high-efficiency, silica-based column specially designed for separating various basic analytes. This new packing material features a combination of both reversed-phase and weak cationexchange properties by incorporating a hydrophobic alkyl chain with carboxyl terminus (Figure ). As a result, this new column provides total control of selectivity and great flexibility for method development, as well as a wide range of applications in pharmaceutical, chemical, food and beverages and other industries. Main Features Adjustable selectivity Orthogonal selectivity Ideal for separating basic analytes: excellent peak shape, sufficient retention, high efficiency Multi-retention mechanisms: reversed-phase, cation-exchange, ion-exclusion, and HILIC Broad range of applications O C O C O C O Silica Gel C O C Silica: High-purity, porous, spherical Particle Size: 5 µm Surface Area: 00 m /g Pore Size: 0 Å 5008 Figure. Column chemistry of Acclaim Mixed-Mode WCX-. Passion. Power. Productivity.

Adjustable Selectivity Selectivity is the most important factor in determining the success of a separation. Although reversed-phase columns (i.e., C8) are most commonly used for small molecule separation, the selectivity is rather similar. Some polar-embedded columns provide somewhat different selectivity that is very often inadequate for many applications. The Acclaim Mixed-Mode WCX- combines both hydrophobic and cation-exchange characteristics, and thus facilitates adjustable selectivity through changes in mobile phase ionic strength, ph and the organic solvent content, individually or concurrently. With increasing ionic strength (cation concentration), the retention decreases for cationic analytes with virtually no change for neutral analytes (Figure ). Because of its weak cationexchange nature, the capacity of the Mixed-Mode WCX- can be adjusted by modifying the mobile phase ph. As shown in Figure, at ph 6.5, the carboxyl group on the surface is negatively charged and both cation-exchange and hydrophobic interaction contribute to the retention. Benzoic acid elutes early due to electro-repulsion and benzyl amine elutes later because of the combination of electro-attraction and hydrophobic retention. At ph.8, on the other hand, the carboxyl group on the surface is protonated and exhibits no cation-exchange capacity, thus hydrophobic interaction is the major force for retention. As a result, protonated benzyl amine elutes first due to its low hydrophobicity, uncharged benzoic acid becomes more retained, and there is virtually no change for the neutral compound: naphthalene. Organic solvent changes hydrophobic retention and can also facilitate selectivity change on the Mixed-Mode WCX- column (Figure 4). 0 mm buffer 0 6 40 mm buffer Column: Acclaim Mixed-Mode WCX-, 5 µm Dimension: 4.6 50 mm Mobile Phase: 50/50 v/v CHCN/sodium phosphate, ph 6.5 Flow Rate: ml/min Detection: UV (5 nm) Peaks:. Benzoic acid 00 µg/ml. Naphthalene 50. Benzyl amine 00 Figure. Adjustable selectivity ionic strength effect. Changing ionic strength affects cation retention without affecting neutral or anionic compounds. Switch On ph 6.5 0 6 Switch Off ph.8 Figure. Adjustable selectivity ph effect. Changing the ph causes the capacity of weak cation-exchange functionality on the stationary phase, and can be switched on or off. 0 5 0 6% MeCN (v/v ) 50% MeCN (v/v ) 5009 Column: Acclaim Mixed-Mode WCX-, 5 µm Dimension: 4.6 50 mm Mobile Phase: 50/50 v/v CHCN/0 mm sodium phosphate Flow Rate: ml/min Detection: UV (5 nm) Peaks:. Benzoic acid 00 µg/ml. Naphthalene 50. Benzyl amine 00 500 Column: Acclaim Mixed-Mode WCX-, 5 µm Dimension: 4.6 50 mm Mobile Phase: CH CN/0 mm sodium phosphate, ph 6.5 Flow Rate: ml/min Detection: UV (5 nm) Peaks:. Benzoic acid 00 µg/ml. Naphthalene 50. Benzyl amine 00 50 Figure 4. Adjustable selectivity organic solvent effect. Changing the mobile phase organic content affects selectivity.

Orthogonal Selectivity Many applications are developed on reversed-phase C8 columns. For some applications, however, regulatory secondary analytical methods are required in addition to the primary method. Usually, secondary methods are developed on a column with selectivity orthogonal to the primary column. Because of its adjustable selectivity, the Mixed-Mode WCX- is an ideal column for this purpose. As shown in Figure 5, the Mixed-Mode WCX- column exhibits different elution order compared to the C8 column under the same condition. In addition, this column provides the selectivity orthogonal to its weak anion-exchange (WAX) counterpart (Figures 6 and 7) because of their opposite retention mechanism.the Mixed-Mode WCX- column not only provides selectivity orthogonal to other column types (RP and WAX), but can also achieve orthogonal selectivities on the same column through its adjustable selectivity. Therefore, along with RP columns, the Acclaim Mixed-Mode WCX- is a useful tool for method development for a broad range of applications., 0 6 Figure 5. WCX vs RP orthogonal selectivity. Figure 6. WCX vs WAX orthogonal selectivity. Mixed Mode WCX- Acclaim 0 C8 0 4 8 Mixed-Mode WCX- Mixed-Mode WAX- Column: 5 µm Dimension: 4.6 50 mm Mobile Phase: 50/50 v/v CHCN/0 mm (total) sodium phosphate buffer, ph 6.5 Flow Rate: ml/min Detection: UV, 5 nm Peaks:. Benzoic acid 00 µg/ml. Naphthalene 50. Benzyl amine 00 50 Column: 5 µm Dimension: 4.6 50 mm Mobile Phase: 60/40 v/v CHCN/ 0 mm sodium phosphate buffer, ph 6.5 Flow Rate: ml/min Detection: UV (5 nm) Peaks:. Benzoic acid 00 µg/ml. Naphthalene 50. Benzyl amine 00 50 Mixed-Mode WCX- Mixed-Mode WAX- Column: 5 µm Dimension: 4.6 50 mm Mobile Phase: 60/40 v/v CHCN/sodium phosphate, ph 6.5 40 mm for Mixed-Mode WCX- 0 mm for Mixed-Mode WAX- Flow Rate: ml/min Inj. Volume: µl Detection: UV (5 nm) Sample: Trimipramine Maleate (50 ppm) Peaks:. Maleate. Trimipramine OH OH O O N 0 5 0 N 504 Figure 7. WCX vs WAX orthogonal selectivity.

Ideal for Basic Analytes Basic compounds are important in a variety of industrial applications, including pharmaceutical, chemical, consumer products, food, and beverages. However, analysis of these compounds is often challenging using reversed-phase silica columns. At neutral ph, these columns often exhibit tailing peaks for basic molecules because of the secondary interaction (ion-exchange) between unreacted silanol groups on the surface and the analyte. Polar-embedded columns were developed to minimize this difficulty and show optimal separation of a wide range of basic molecules. However, highly hydrophilic, basic molecules are not retained adequately without the use of ion-pairing agents to improve retention. As a consequence, the HPLC method requires a more complicated mobile phase that is incompatible with MS, and often a dedicated column. The Acclaim Mixed-Mode WCX- circumvents these difficulties. Not only does it retain basic molecules (from highly hydrophilic such as sodium ion to highly hydrophobic such as amitriptyline), but it also elutes them with symmetrical peak shapes and excellent efficiency (see Figures 0 4). Multiple-Retention Mechanisms Because of its novel column chemistry, the Acclaim Mixed-Mode WCX- column offers multiple retention mechanisms, including RPLC, cationexchange, ion-exclusion and HILIC. Figure 8 demonstrates that in highly organic mobile phase, the Mixed-Mode WCX- column can serve as a HILIC column. Hydrophilic analytes such as cytosine elute later than hydrophobic neutral analytes (naphthalene). The multiple retention mechanisms facilitate the column's effectiveness in many applications that require different selectivities. 0 5 0 Figure 8. RPLC mode vs HILIC mode. Figure 9. Simultaneous separation of acidic, neutral, and basic pharmaceuticals. Simultaneous Separation of Basic, Neutral, and Acidic Molecules Separation of different types of molecules including bases, neutrals, and acids (BNAs) within a single chromatographic run on the same column is highly desirable but challenging. The unique column chemistry of the Acclaim Mixed-Mode WCX- provides multiple separation mechanisms. Consequently, retention of basic, neutral, and acidic molecules can be either independently or concurrently adjusted by changing mobile phase 4 5 HILIC Mode RPLC Mode 0 4 8 6 7 Column: Acclaim Mixed-Mode WCX-, 5 µm Dimension: 4.6 50 mm Mobile Phase: CHCN/NH 4 OAc, ph 5 (5 mm total) v/v 95/5 for HILIC mode operation v/v 50/50 for RP mode operation Flow Rate: ml/min Detection: UV (70 nm) Peaks: 00 ppm each. Cytosine. Naphthalene Column: Acclaim Mixed-Mode WCX-, 5 µm Dimension: 4.6 50 mm Mobile Phase: 40/60 v/v CHCN/NH 4 OAc, ph 5. (0 mm total) Flow Rate: ml/min Detection: UV (5 nm) Peaks:. Maleate 50 µg/ml. Ketoprofen 0. Naproxen 0 4. Hydrocortisone 60 5. Dexamethasone 60 6. Oxprenolol 00 7. Timolol 50 505 506 ionic strength, ph, or organic solvent content. While all types of molecules are retained by hydrophobic interaction, the cation-exchange functionality results in increased retention for cationic species through electrostatic attraction, decreased retention for anionic compounds through electrostatic repulsion, and virtually no effect on neutral molecules. Figure 9 demonstrates simultaneous separations of a mixture of basic, neutral, and acidic molecules using an isocratic method, with excellent peak shape and resolution. 4

Broad Range of Applications The Acclaim Mixed-Mode WCX- column can serve as a primary column for a variety of basic analytes and as a secondary column that provides selectivity orthogonal to that of reversedphase columns. Thus it is an invaluable tool for HPLC method development for a broad range of applications, such as pharmaceutical, food and beverage, and chemical analyses. Figures 0 and show that both hydrophilic basic pharmaceuticals (catecholamines) and hydrophobic basic drugs (antidepressants) are retained and separated on this column with excellent peak shape and efficiency without using ion-pairing agents. Tris is known as trishydroxymethylaminomethane, with the formula (HOCH ) CNH. In biochemistry, it is widely used as a component of buffer solutions, especially for solutions of nucleic acids. Due to its hydrophilic nature, it is difficult to determine Tris by RPLC. By comparison, it is an easy task when using the Acclaim Mixed- Mode WCX- column (Figure ). 0 7.5 5 Figure 0. Separation of catecholamines. 4 4 5 6 Column: Acclaim Mixed-Mode WCX-, 5 µm Dimension: 4.6 50 mm Mobile Phase: /98 v/v CH CN/sodium phosphate, ph 6. (0 mm total concentration) Flow Rate: ml/min Detection: UV (5 nm) Peaks: (0.5 mm each). NE. E. DHBA 4. DA Column: Acclaim Mixed-Mode WCX-, 5 µm Dimension: 4.6 50 mm Mobile Phase: 50/50 v/v CH CN/0 mm NH 4 OAc, ph 5. Flow Rate: ml/min Detection: UV (5 nm) Peaks: 00 ppm each. Doxepin (mixture of isomers). Imipramine. Trimipramine 4. Amitriptyline (As. =.08, 6 plates/column) 5. Protriptyline 6. Nortriptyline 507 0 0 0 508 Figure. Separation of antidepressants. 5 mm 0 mm Column: Acclaim Mixed-Mode WCX-, 5 µm Dimension: 4.6 50 mm Mobile Phase: 50/50 v/v CHCN/NH 4 OAc, ph 5. Flow Rate: ml/min Sample: Tris HCl ( mg/ml) Peaks:. Cl. TrisH + 0 mm 0 4 8 509 Figure. Analysis of tris HCl salt. 5

Quaternary amines are used as oil-wetting agents, corrosion and shale inhibitors and bactericides. Figure demonstrates the capability of the new column for separating a series of alkyl quaternary amines. Phosphonium salts are used as chemical reagents for Witting reaction, corrosion inhibitors, and flameretardants. As shown Figure 4, the phosphonium cation elutes on the Acclaim Mixed-Mode WCX- column with excellent peak shape and adequate retention that can be tuned by changing mobile phase ionic strength. 40 mm 0 mm 0 mm 0 7.5 5 Figure. Analysis of quaternary amines. Column: Acclaim Mixed-Mode WCX-, 5 µm Dimension: 4.6 50 mm Mobile Phase: 50/50 v/v CHCN/NH 4 OAc, ph 5. Flow Rate: ml/min Peaks: (00 ppm each). (CH CH CH )4N +. (CH CH CH CH )4N +. (CH CH CH CH CH )4N + 500 40 mm 0 mm Column: Acclaim Mixed-Mode WCX-, 5 µm Dimension: 4.6 50 mm Mobile Phase: 60/40 v/v CHCN/NH 4 OAc, ph 5. Flow Rate: ml/min Inj. Volume: µl Sample: Tetrabutylphosphonium bromide (0.%). Br. (CH CH CH CH )4P + 0 mm 0 6 50 Figure 4. Analysis of phosphonium salt. ph.5 ph 4.0 ph 4.5 Column: Acclaim Mixed-Mode WCX-, 5 µm Dimension: 4.6 50 mm Mobile Phase: 5 mm NH 4 OAc buffer Flow Rate: ml/min Inj. Volume: µl Sample: NaCl ( mm) Peaks:. Cl. Na + ph 5.0 0.5 5 50 Figure 5. Analysis of NaCl. 6

Inorganic cations (i.e. Na + and Ca + ) are very important analytes in many samples: pharmaceutical, food, biosciences, chemical, and environmental. While reversed-phase columns fail to retain Na + and Ca + ions, the Acclaim Mixed-Mode WCX- provides adequate retention for both using MS friendly mobile phases (Figures 5 and 6). In pharmaceutical formulation, Na + is often used as the counter ion for acidic active pharmaceutical ingredients (APIs). Figure 7A demonstrates that not only can the Acclaim Mixed-Mode WCX- column retain and measure Na + ion, but it can also measure the acidic API in the same analysis. The elution order can be changed by adjusting mobile phase ionic strength (Figure 7B). Reproducible Manufacturing Each Acclaim Mixed-Mode WCX- column is manufactured to stringent specifications to ensure column-to-column reproducibility. Each column is shipped with a qualification assurance report. 0.5 5 Figure 6. Analysis of CaCl. B ph.5 ph.8 ph 4. ph 4.4 Column: Acclaim Mixed-Mode WCX-, 5 µm Dimension: 4.6 50 mm Mobile Phase: 0 mm NH 4 OAc buffer Flow Rate: ml/min Inj. Volume: µl Sample: CaCl ( mg/ml) Peaks:. Cl. Ca + A Column: Acclaim Mixed-Mode WCX-, 5 µm Dimension: 4.6 50 mm Mobile Phase: (A) 50/50 v/v CHCN/NH 4 OAc, ph 5., 5 mm (total) (B) 0/70 v/v CH CN/NH 4 OAc, ph 5., 5 mm (total) Flow Rate: ml/min Inj. Volume: µl Sample: Naproxen sodium salt ( mg/ml) 0 5 0 Peaks:. Naproxen. Na + 50 5 mm 0 mm 0 4 8 504 Figure 7. Analysis of Naproxen sodium salt. A) Analysis of counterion only. B) Simultaneous separations of both API and its counterion (with adjustable selectivity). 7

SPECIFICATIONS Column chemistry: Proprietary carboxylic group Base silica: High purity, spherical, porous Particle size: 5 µm Pore size: 0 Å Surface area: 00 m /g ORDERING INFORMATION In the U.S. call -800-46-690, or contact the Dionex Regional Office nearest you. Outside the U.S., order through your local Dionex office or distributor. Refer to the following part numbers. Acclaim Mixed-Mode WCX Columns Acclaim Mixed-Mode WCX, 5 µm (4.6 50 mm)...0685 Acclaim Mixed-Mode WCX, 5 µm (4.6 50 mm)...0685 Acclaim Mixed-Mode WCX Guard, 5 µm, /pk (4. 0 mm)...06854 Acclaim Guard Kit (holder and coupler)...05956 Acclaim SST Guard Cartridge Holder...059456 Acclaim Guard to Analytical Column Coupler...059457 Acclaim is a registered trademark of Dionex Corporation. Passion. Power. Productivity. Dionex Corporation 8 Titan Way P.O. Box 60 Sunnyvale, CA 94088-60 North America U.S. (847) 95-7500 Canada (905) 844-9650 South America Europe Austria (4) 66 5 5 Benelux () 0 68 9768; () 5 494 Denmark (45) 6 6 90 90 France () 9 0 0 0 Germany (49) 66 99 0 Ireland (5) 644 0064 Italy (9) 0 5 6 67 Switzerland (4) 6 05 9966 Asia Pacific United Kingdom (44) 76 697 Brazil (55) 7 540 8 (408) 77-0700 www.dionex.com Australia (6) 940 5 China (85) 48 8 India (9) 764 75 Japan (8) 6 6885 Korea (8) 65 580 Singapore (65) 689 90 Taiwan (886) 875 6655 LPN 04 7M 0/08 008 Dionex Corporation