VersaFlow Ultrasonic clamp-on Flowmeter Specifications

Similar documents
VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

VersaFlow TWM 9000 Electromagnetic Flow Converter Technical Datasheet. Specification. Highlights. Electromagnetic product range.

VersaFlow TWM 9000 Electromagnetic Flow Converter Technical Datasheet. Specification. Highlights. Electromagnetic product range.

Reflex-Radar BM 100 A

Ultrasonic Gas Flow Meter

Electromagnetic Flowmeter

ED 701 General Industry Pressure Transmitter

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

SLH-K Handheld Ultrasonic Flowmeter

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

tekcor TKC Multivariable Coriolis Flow Sensors

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

SmartLine Radar Level Meter RM70

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Technical specification FLUXUS F502TE

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

ISEmax CAM40/CAS40. Technical Information

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter

Pressure Measurement Single-range transmitters for general applications

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

ADI 2040 Process Analyzer

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

Metso Concentration Measurement 3300

TH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Full Metal Variable Area Flow Meter and Counter

AC axial compact fan

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16

Pressure Transmitter ED 701

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

Pressure transmitters for industrial applications MBS 32 and MBS 33

Calio-Therm NC Type Series Booklet

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Exchangeable measuring insets SensyTemp TSA101

Tecnología en Electrónica y Control SRL Ficha Técnica

PHOS 15 LED PROJECTOR

Information Technology Solutions Neptune Datasheet

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

ISEmax CAS40D. Technical Information

FXP DATASHEET JUNHO 2013

Installation guide 862 MIT / MIR

Surface-mounting Thermostats ATH Type Series

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Linear measuring technology

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

AC axial compact fan

Field IT 50T Series Transmitters

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

Conductivity sensor for hygienic applications

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

VK2 volume flow controller Overview

Wind Speed & Direction Sensors

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

Oscillation Flow Meter for Gases

Field mounted Temperature Transmitter TF212/TF212-Ex

Target Insertion Flowmeter

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

One-hand ph/temperature measuring instrument

Pressure independent balancing and control valve AB QM DN

FLOW SENSOR FOR LIQUID MEDIA Serie 210


A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

Cooling Water Flow Regulator

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

close to performances of the turbine gas meters designed for custody transfer measurements.

Direct-operated 2/2-way solenoid valves Type EV210B

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

5SJ4...-.HG Circuit Breakers to IEC and UL 489

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

CTC 155 / 350 / 660 Dry-block calibrator

Industrial Resistance Thermometers according to DIN Model MWD

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

Transcription:

VersaFlow Ultrasonic clamp-on Flowmeter Specifications 34-VF-03-14 September 2009 Clamp-On Technology HONEYWELL S VersaFlow stands for continuity and long term reliability. Flow measurement can be done anywhere and startup is immediate. The new VersaFlow clamp on flowmeter for liquids with its robust industrial construction and regreasing concept provides a revolutionary solution for easy handling. Figure 1 VersaFlow Ultrasonic clamp-on Flowmeter Highlights Minimised uncertainty Optimised reliability Minimal maintenance Efficient regreasing concept Easy sensor mounting Installation wizard All in one system Applications Chemical addition General process control Cooling water circuits Broad range of refined hydrocarbons Potable water De-ionized and demineralized water Sanitary flow rate measurements Purified water Industries Chemicals Petrochemical Power Plants Water Oil & Gas Semi-conductor Food & Beverage Pharmaceuticals

VersaFlow Ultrasonic clamp-on Flowmeter 2 VersaFlow Variants The VersaFlow is an ultrasonic clamp-on flowmeter that can be fitted on the outside of piping to measure the flowrate of liquids. The flowmeters consists of a combination of one or two VersaFlow clamp-on sensor(s) and one TWS9000 ultrasonic flow converter. VersaFlow Clamp-On Sensors 1. Small: chemical addition applications, cooling circuits 2. Medium: purified water applications, hydrocarbons 3. Large: all water applications, especially for large pipe sizes TWS9000 Ultrasonic Flow Converter 1. TWS9000 W: Wall mounted, PA, non-ex, IP65 2. TWS9000 F: Field version, die-cast aluminum, (non-) Ex, IP66/67 s 1. VersaFlow XT-small: sensor for extended temperature 2. VersaFlow XT-medium: Sensor for extended temperature

VersaFlow Ultrasonic clamp-on Flowmeter 3 Technical Data Ultrasonic flowmeter VersaFlow Versions VersaFlow VersaFlow - Ex, zone 1/2 Performance Measurement functionality Measuring range Max. deviation (under reference conditions] actual volume flow rate and totalised volume 0...20 m/s / 0...66 ft/s <± 1% of M.V. for DN ~ 50 mm / 2", v > 0.5 m/s / 1.5 ft/s <± 3% of M.V. for DN < 50 mm / 2", v > 0.5 m/s / 1.5 ft/s Repeatability <± 0.2% Process conditions Solid particle content < 5% (by volume) Gas content < 2% (by volume) Measurement Configurations Single path, single pipe or dual path/dual pipe Ultrasonic Flow Sensor VersaFlow Versions VersaFlow - small (DN15...DN100 / ½...4") VersaFlow - medium (DN50...DN400 / 2...16 ) VersaFlow - large (DN200...DN4000 / 8...160 ) VersaFlow - small (ext. temp. DN15...DN100 / ½...4 ) VersaFlow - medium (ext. temp. DN50...DN400 / 2..16 ) Pipe Specifications Material: metal, plastic, ceramic, asbestos cement, internal/external coated pipes (coatings and liners fully bonded to pipe wall) Maximum pipewall thickness of 200 mm / 7.87" Protection Category IP67 Electric Signal Level Ex-I, intrinsically safe circuits, floating Process Temperature -40...120 C / -40...284 F -50...200 C / -58...392 F, XT version

VersaFlow Ultrasonic clamp-on Flowmeter 4 Sensor Cable Length 5 m / 15 t 10 m / 30ft 20 m / 0ft 30 m / 90ft Recommended Mounting Areas Inlet Outlet ~ 10DN ~ 5DN Ultrasonic Flow Converter TWS9000 Versions W (wall) F (field) F(/i-)Eex, zone 1/2 Display Languages With Local display English, French, German TWS9000 W (general purpose) TWS9000 F (non-ex) TWS9000 F-Ex Flow Sensor VersaFlow DN15...4000 / ½...160 1 Communication Current, pulse & status output HART communication, control input Power Supply 100...230 VAC (-15/+10%), 50/60 Hz 24 VAC/DC Power consumption Approvals EEx - zone 1, zone 2 FM - Class I DIV 1, DIV 2 CSA - / Class I DIV 1, DIV 2 Protection Category W (wall) F (field) Temperature Process 22 VA IP65 (eq. to NEMA 4/4X) IP66/67 (eq. to NEMA6) see flow sensor Ambient -40...60 C / -40...140 F Storage -50...70 C / -58...158 F Cable Connection M20 x 1.5 ½ NPT PF ½ 1 Outer Diameter: 20 4300 mm / 0.79 169.29

VersaFlow Ultrasonic clamp-on Flowmeter 5 Materials Used Polyamide - polycarbonate (W-version) Die-cast aluminium with polyurethane coating) (F-version) Stainless steel 316 L / 1.4404 (F-version) Overall Functionality Highlights Continuous measurement of actual volume flow rate, flow velocity, velocity of sound, damping of acoustic signal, signal to noise ratio Flow direction (forward or reverse) Totalisation of volume flow Reliability of flow measurement, Quality of acoustic signal Current Output Function All operating data configurable; galvanically isolated; HART communication Settings Q = 0% Q = 100% Error identification Connection Active: Basic/Modular IO Ex-I I/O Connection Passive: Basic/Modular IO Ex-I I/O 0...15 ma 10...22 ma 0...22 ma I 22 ma / R L 1 kohm I 22 ma / R L 470 Ù U O = 21V / l O = 90 ma P O = 0.5 W C O = 90 nf / L O = 2 mh L 22mA / U 32 VDC I 22 ma U i = 30 V / l i = 100 ma P i = 1 W C i = 10 nf / L i ~ 0 mh

VersaFlow Ultrasonic clamp-on Flowmeter 6 Pulse Output and Status Output Function Settings Q = 100% Pulse width Status Connection Active: Basic IO Ex-I I/O Connection Passive: Basic IO Configurable as pulse output, identification for automatic range change, indicator of flow direction, overflow, errors, trip point or empty pipe indication Valve control, if batch control function is activated 0.0001...10000 pulses/s or pulses/volume 0.1...1000 ms or auto or sym. On or Off On request On request f 10 khz: I 20 ma f 10 Hz: I 100 ma U 32 VDC / I 100 ma Ex-I I/O Acc. EN 60947-5-6 U i = 30V / I i = 100 ma P i = 1 W C i = 10 nf/l i ~ 0 mh Connection NAMUR: Basic IO Ex-I I/O On request "Active" Control Input Function Settings Freeze output (e.g. during cleaning), forced return to zero, counter and error reset, ext. range selection. Freeze outputs, output zero, reset counter, reset error Connection Active: Basic IO l nom 16mA / U nom 24VDC Ex-I I/O Acc. EN 60947-5-6 Connection Passive: Basic IO U d 32 VDC U on ~ 19 VDC / U off < 2.5 VDC Ex-I I/O On request Connection NAMUR: Basic IO Ex-I I/O On request "Active"

VersaFlow Ultrasonic clamp-on Flowmeter 7 I/O Specifications Overall Functionality Function Continuous measurement of actual volume flow, mass flow, flow speed velocity of sound gain SNR diagnosis value. Bidirectional flow measurement and totalisation. Signal quality bar graph Current Output Function Settings Connection Basic / Modular IO: Active Ex-i: Active Basic/ Modular IO: Passive Ex-i: Passive All operating data configurable; galvanically isolated; HART communication Q = 0%:0...15mA Q = 100%: 10...22mA Error identification: 0...22mA l 22mA / R L 1 kohm l 22mA / R L 470 Ohm U O = 21 V/l 0 = 90mA P O = 0.5W C O = 90nF / L0 = 2mH l 22mA / U 32VDC I 22mA U i = 30V / l i = 100mA P i = 1W C i = 10nF / L i ~ 0mH Pulse Output and Status Output Function Settings Connection Basic/ Modular IO: Passive Passive Active Namur (ace. to EN 60947-5-6) Configurable as pulse output, identification for automatic range change, indicator of flow direction, overflow, errors, trip point or empty pipe indication Q = 100%: 0.0001... 10000 pulses per second or pulses per unit volume Pulse width: 0.05...2000ms or auto or sym. Status: On or Off f 10kHz: I 20mA f 10Hz: I 100mA U 32 VDC / l 100mA U i = 30V / l i = 100mA P i = 1W C i = 10nF / L i i ~ 0mH U nom = 24VDC / l <1 ma U O = 1.5 V at 10mA Passive

VersaFlow Ultrasonic clamp-on Flowmeter 8 Control Input Function Settings Connection Basic / Modular IO: Active Basic/ Modular IO: Passive Namur (ace. to EN 60947-5-6) Freeze output (e.g. during cleaning), forced return to zero, counter and error reset, ext. range selection. Freeze outputs, output zero, reset counter, reset error, start batch (in batch mode) l nom = 16mA / U nom = 24VDC U 32VDC U on > 19VDC / U off < 2.5VDC Active

VersaFlow Ultrasonic clamp-on Flowmeter 9 I/O Module Combination Possibilities Communications Basic I/O Ex-I I/O 1 Modular I/O 2 Current Input Active/passive HART Pulse and Status Output Active Passive Namur (acc. To EN 60947-5-6) Control Input Active Passive Namur (acc. To EN 60947-5-6) Foundation Fieldbus Foundation Fieldbus (pending) Protection Ex-d/e optional On request Note: 1 Ex-i I/O: up to 1 additional in-/output modules possible (see l/o-module combinations) 2 Modular I/O: up to 2 additional in-/output module possible (see l/0-module combinations)

VersaFlow Ultrasonic clamp-on Flowmeter 10 I/O modules 1 I/O 2 1st module 3 2nd module 1 Basic 0 no module possible 0 no module possible 2 Ex-i (Ia + Pp) 1 Ex-i (Ia + Pp/Cp) 3 Ex-i (Ip + Pp) 2 Ex-i (Ip + Pp/Cp) 4 Modular (Ia + Pa) 8 no module 8 no module 6 Modular (Ia + Pp) A Ia A Ia Ia = current output - active 7 Modular (Ia + Pn) B Ip B Ip Ip = current output - passive 8 Modular (Ip + Pa) C Pa/Sa C Pa/Sa Pa/Sa = pulse/status output - active, high current B Modular (Ip + Pp) E Pp/Sp E Pp/Sp Pp/Sp = pulse/status output - passive, high current C Modular (Ip + Pn) F Pn/Sn F Pn/Sn Pn/Sn = pulse/status output - passive, Namur The TWS9000 with standard basic I/O covers almost all applications, having k I/Os: active/passive current output (+HART ) passive pulse/status output passive status output passive status output / control input The l/0-module combination is thus 1-0-0 (see above). The TWS9000 with modular I/O can be tailor-made to any application: Suppose you require a converter with passive pulse output and 3 passive current outputs. The l/0-module combination then becomes B-B-B. Suppose you require a converter with 2 active pulse/status outputs. The l/0-module combination then becomes either 4-C-8 or 8-C-8 (depending on whether active or passive current output is required). The latter '8' indicates that 1 additional module can be added in future.

VersaFlow Ultrasonic clamp-on Flowmeter 11 Example for Combination of I/O s Basic I/O Ex-I/O 1 2 3 1 2 3 1 0 0 2 0 0 1 2 3 0 0 1 2 D 0 0 1 2 E 0 0 1 2 Modular I/O 1 2 3 1 2 3 1 2 3 4 8 8 8 8 8 D 8 8 A B B 8 A 8 A B A C C C G G K C 8 C 8 C 8 C C C G G K G 8 G 8 K 8 G G K 6 8 8 C 8 8 E 8 8 A 8 B 8 A 8 A B A E E C K K K E 8 E 8 C 8 E E C K K K K 8 H 8 K 8 K H K 7 8 8 C 8 8 F 8 0 A 8 B 8 A A B B F F C H H D F 8 F 8 E F F F H H G H 8 H 8 H H H K

VersaFlow Ultrasonic clamp-on Flowmeter 12 Dimensions and Weights Version Dimensions [mm] Approx. weight (without cable / L H W [kg] small 496.3 71 63.1 2.7 medium 826.3 71 63.1 3.6 large 496.3 1 71 1 63.1 1 2.7 1 Version Dimensions [inches] Approx. weight (without cable / ti ) L H W [lbs] small 19.5 2.8 2.5 6.0 medium 32.5 2.8 2.5 7.9 large 19.5 1 2.8 1 2.5 1 6.0 1 1 Value for one of the 2 delivered rails

VersaFlow Ultrasonic clamp-on Flowmeter 13 1) TWS9000 W 2) TWS9000 F Version Dimensi [mm] Weight [kg] a b c f g h TWS9000 W 198 138 299 - - - 2.4 TWS9000 F 202 120 155 141 296 277 5.7 Version Dimensio [inches] Weight [lbs] a b c f g h TWS9000 W 7.8 5.4 11.8 - - - 5.3 TWS9000 F 7.75 4.75 6.1 5.5 11.6 10.9 12.6

VersaFlow Ultrasonic clamp-on Flowmeter 14 Dimensions [mm] a b c Approx. weight (without cable/metal [kg] Cable box 102 197 67 0.85 Dimensions [inches] Approx. weight a b c (without cable/metal [lbs] Cable box 4.01 7.76 2.64 1.87

VersaFlow Ultrasonic clamp-on Flowmeter 15 Specifications are subject to change without notice. For More Information Learn more about how Honeywell s VersaFlow Ultrasonic clamp-on Flowmeter can provide long term reliability, visit our website www.honeywell.com/ps/hfs or contact your Honeywell account manager. Honeywell Process Solutions 1860 West Rose Garden Lane Phoenix, Arizona 85027 Tel: 1-800-423-9883 or 1-800-343-0228 www.honeywell.com/ps 34-VF-03-14 September 2009 2010 Honeywell International Inc.