VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

Similar documents
VersaFlow Ultrasonic clamp-on Flowmeter Specifications

VersaFlow TWM 9000 Electromagnetic Flow Converter Technical Datasheet. Specification. Highlights. Electromagnetic product range.

VersaFlow TWM 9000 Electromagnetic Flow Converter Technical Datasheet. Specification. Highlights. Electromagnetic product range.

Reflex-Radar BM 100 A

Ultrasonic Gas Flow Meter

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

Electromagnetic Flowmeter

ED 701 General Industry Pressure Transmitter

SLH-K Handheld Ultrasonic Flowmeter

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

tekcor TKC Multivariable Coriolis Flow Sensors

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

SmartLine Radar Level Meter RM70

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

Technical specification FLUXUS F502TE

Information Technology Solutions Neptune Datasheet

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

ISEmax CAM40/CAS40. Technical Information

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Conductivity sensor for hygienic applications

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter

Metso Concentration Measurement 3300

AC axial compact fan

LABSONIC The convenient ultrasonic homogenizer for your laboratory

Pressure Measurement Single-range transmitters for general applications

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

TPC Suppressor Capacitors Classes X & Y A KYOCERA GROUP COMPANY

ADI 2040 Process Analyzer

Full Metal Variable Area Flow Meter and Counter

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

Pressure transmitters for industrial applications MBS 32 and MBS 33

Calio-Therm NC Type Series Booklet

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Field IT 50T Series Transmitters

Oscillation Flow Meter for Gases

TH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

Wind Speed & Direction Sensors

AC axial compact fan

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Industrial Resistance Thermometers according to DIN Model MWD

ISEmax CAS40D. Technical Information

Surface-mounting Thermostats ATH Type Series

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

VK2 volume flow controller Overview

Exchangeable measuring insets SensyTemp TSA101

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Pressure Transmitter ED 701

Tecnología en Electrónica y Control SRL Ficha Técnica

FXP DATASHEET JUNHO 2013

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Linear measuring technology

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

Switches in conformity with ATEX directive

Single Phase Motors Technical Datasheets

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

Direct-operated 2/2-way solenoid valves Type EV210B

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

Surface-mounting thermostats Series ATH

PHOS 15 LED PROJECTOR

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

Cooling Water Flow Regulator

473-SHX Dew Point Mirror

System Components. Electric Motors.

YOKOGAWA. General Specifications. ROTAMASS Compact. Coriolis Mass Flowmeter

PHOENIX CONTACT - 04/2016. Features

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

V5013B-F Three-Way Mixing & Diverting Valves

Field mounted Temperature Transmitter TF212/TF212-Ex

Transcription:

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement can be done anywhere and startup is immediate. The new VERSAFLOW clamp on flowmeter for liquids with its robust industrial construction and regreasing concept provides a revolutionary solution for easy handling Figure 1 VersaFlow Ultrasonic clamp-on Flowmeter Highlights Applications Minimised uncertainty Optimised reliability Minimal maintenance Efficient regreasing concept Easy sensor mounting Installation wizard All in one system Industries Chemical addition General process control Cooling water circuits Broad range of refined hydrocarbons Potable water De-ionized and demineralized water Sanitary flow rate measurements Purified water Chemicals Petrochemical Power Plants Water Oil & Gas Semi-conductor Food & Beverage Pharmaceuticals

Page 2 VERSAFLOW variants The VERSAFLOW is an ultrasonic clamp-on flowmeter that can be fitted on the outside of piping to measure the flowrate of liquids. The flowmeters consists of a combination of one or two VERSAFLOW clamp-on sensor(s) and one TWS9000 ultrasonic flow converter. VERSAFLOW clamp-on sensors 1. Small: chemical addition applications, cooling circuits 2. Medium: purified water applications, hydrocarbons 3. Large: all water applications, especially for large pipe sizes TWS9000 ultrasonic flow converter 1. TWS9000 W: Wall mounted, PA, non-ex, IP65 2. TWS9000 F: Field version, die-cast aluminum, (non-) Ex, IP66/67 s 1. VERSAFLOW XT-small: sensor for extended temperature 2. VERSAFLOW XT-medium: Sensor for extended temperature

Page 3 Technical Data Ultrasonic flowmeter VERSAFLOW Versions VERSAFLOW VERSAFLOW - Ex, zone 1/2 Performance Measurement functionality Measuring range Max. deviation (under reference conditions] actual volume flow rate and totalised volume 0...20 m/s / 0...66 ft/s <± 1% of M.V. for DN ~ 50 mm / 2", v > 0.5 m/s / 1.5 ft/s <± 3% of M.V. for DN < 50 mm / 2", v > 0.5 m/s / 1.5 ft/s Repeatability <± 0.2% Process conditions Solid particle content < 5% (by volume) Gas content < 2% (by volume) Measurement configurations Single path, single pipe or dual path/dual pipe Ultrasonic flow sensor VERSAFLOW Versions VERSAFLOW - small (DN15...DN100 / ½...4") VERSAFLOW - medium (DN50...DN400 / 2...16 ) VERSAFLOW - large (DN200...DN4000 / 8...160 ) VERSAFLOW - small (ext. temp. DN15...DN100 / ½...4 ) VERSAFLOW - medium (ext. temp. DN50...DN400 / 2..16 ) Pipe specifications Material: metal, plastic, ceramic, asbestos cement, internal/external coated pipes (coatings and liners fully bonded to pipe wall) Maximum pipewall thickness of 200 mm / 7.87" Protection category IP67 Electric signal level Ex-I, intrinsically safe circuits, floating Process temperature -40...120 C / -40...284 F -50...200 C / -58...392 F, XT version

Page 4 Sensor cable length 5 m / 15 t 10 m / 30ft 20 m / 0ft 30 m / 90ft Recommended mounting areas Inlet Outlet ~ 10DN ~ 5DN Ultrasonic flow converter TWS9000 Versions W (wall) F (field) F(/i-)Eex, zone 1/2 Display languages With Local display English, French, German TWS9000 W (general purpose) TWS9000 F (non-ex) TWS9000 F-Ex Flow Sensor VERSAFLOW DN15...4000 / ½...160 1 Communication Current, pulse & status output HART communication, control input Power Supply 100...230 VAC (-15/+10%), 50/60 Hz 24 VAC/DC Power consumption 22 VA Approvals EEx - zone 1, zone 2 FM - Class I DIV 1, DIV 2 CSA - / Class I DIV 1, DIV 2 Protection category W (wall) F (field) IP65 (eq. to NEMA 4/4X) IP66/67 (eq. to NEMA6) Temperature Process see flow sensor Ambient -40...60 C / -40...140 F Storage -50...70 C / -58...158 F Cable connection M20 x 1.5 ½ NPT PF ½ 1 Outer Diameter: 20 4300 mm / 0.79 169.29

Page 5 Materials used Polyamide - polycarbonate (W-version) Die-cast aluminium with polyurethane coating) (F-version) Stainless steel 316 L / 1.4404 (F-version) Overall functionality Highlights Continuous measurement of actual volume flow rate, flow velocity, velocity of sound, damping of acoustic signal, signal to noise ratio Flow direction (forward or reverse) Totalisation of volume flow Reliability of flow measurement, Quality of acoustic signal Current Output Function Settings Q = 0% Q = 100% Error identification Connection Active: Basic/Modular IO Ex-I I/O Connection Passive: Basic/Modular IO Ex-I I/O All operating data configurable; galvanically isolated; HART communication 0...15 ma 10...22 ma 0...22 ma I 22 ma / R L 1 kohm I 22 ma / R L 470 Ù U O = 21V / l O = 90 ma P O = 0.5 W C O = 90 nf / L O = 2 mh L 22mA / U 32 VDC I 22 ma U i = 30 V / l i = 100 ma P i = 1 W C i = 10 nf / L i ~ 0 mh

Page 6 Pulse output and status output Function Configurable as pulse output, identification for automatic range change, indicator of flow direction, overflow, errors, trip point or empty pipe indication Settings Q = 100% Pulse width Status Connection Active: Basic IO Ex-I I/O Connection Passive: Basic IO Valve control, if batch control function is activated 0.0001...10000 pulses/s or pulses/volume 0.1...1000 ms or auto or sym. On or Off On request On request f 10 khz: I 20 ma f 10 Hz: I 100 ma U 32 VDC / I 100 ma Ex-I I/O Acc. EN 60947-5-6 U i = 30V / I i = 100 ma P i = 1 W Connection NAMUR: Basic IO Ex-I I/O Control input Function C i = 10 nf/l i ~ 0 mh On request "Active" Freeze output (e.g. during cleaning), forced return to zero, counter and error reset, ext. range selection. Settings Freeze outputs, output zero, reset counter, reset error Connection Active: Basic IO l nom 16mA / U nom 24VDC Ex-I I/O Acc. EN 60947-5-6 Connection Passive: Basic IO Ex-I I/O Connection NAMUR: Basic IO Ex-I I/O U d 32 VDC U on ~ 19 VDC / U off < 2.5 VDC On request On request "Active"

Page 7 I/O Specifications Overall functionality Function Current output Function Settings Connection Basic / Modular IO: Active Ex-i: Active Basic/ Modular IO: Passive Ex-i: Passive Pulse output and Status output Function Settings Connection Basic/ Modular IO: Passive Passive Active Namur (ace. to EN 60947-5-6) Control input Function Settings Connection Basic / Modular IO: Active Basic/ Modular IO: Passive Namur (ace. to EN 60947-5-6) Continuous measurement of actual volume flow, mass flow, flow speed velocity of sound gain SNR diagnosis value. Bidirectional flow measurement and totalisation. Signal quality bar graph All operating data configurable; galvanically isolated; HART communication Q = 0%:0...15mA Q = 100%: 10...22mA Error identification: 0...22mA l 22mA / R L 1 kohm l 22mA / R L 470 Ohm U O = 21 V/l 0 = 90mA P O = 0.5W C O = 90nF / L0 = 2mH l 22mA / U 32VDC I 22mA U i = 30V / l i = 100mA P i = 1W C i = 10nF / L i ~ 0mH Configurable as pulse output, identification for automatic range change, indicator of flow direction, overflow, errors, trip point or empty pipe indication Q = 100%: 0.0001... 10000 pulses per second or pulses per unit volume Pulse width: 0.05...2000ms or auto or sym. Status: On or Off f 10kHz: I 20mA f 10Hz: I 100mA U 32 VDC / l 100mA U i = 30V / l i = 100mA P i = 1W C i = 10nF / L i i ~ 0mH U nom = 24VDC / l <1 ma U O = 1.5 V at 10mA Passive Freeze output (e.g. during cleaning), forced return to zero, counter and error reset, ext. range selection. Freeze outputs, output zero, reset counter, reset error, start batch (in batch mode) l nom = 16mA / U nom = 24VDC U 32VDC U on > 19VDC / U off < 2.5VDC Active

Page 8 I/O module combination possibilities Communications Basic I/O Ex-I I/O 1 Modular I/O 2 Current Input Active/passive HART Pulse and status output Active Passive Namur (acc. To EN 60947-5-6) Control Input Active Passive Namur (acc. To EN 60947-5-6) Foundation Fieldbus Foundation Fieldbus (pending) Protection Ex-d/e optional On request Note: 1 Ex-i I/O: up to 1 additional in-/output modules possible (see l/o-module combinations) 2 Modular I/O: up to 2 additional in-/output module possible (see l/0-module combinations)

Page 9 I/O modules 1 I/O 2 1st module 3 2nd module 1 Basic 0 no module possible 0 no module possible 2 Ex-i (Ia + Pp) 1 Ex-i (Ia + Pp/Cp) 3 Ex-i (Ip + Pp) 2 Ex-i (Ip + Pp/Cp) 4 Modular (Ia + Pa) 8 no module 8 no module 6 Modular (Ia + Pp) A Ia A Ia Ia = current output - active 7 Modular (Ia + Pn) B Ip B Ip Ip = current output - passive 8 Modular (Ip + Pa) C Pa/Sa C Pa/Sa Pa/Sa = pulse/status output - active, high current B Modular (Ip + Pp) E Pp/Sp E Pp/Sp Pp/Sp = pulse/status output - passive, high current C Modular (Ip + Pn) F Pn/Sn F Pn/Sn Pn/Sn = pulse/status output - passive, Namur The TWS9000 with standard basic I/O covers almost all applications, having k I/Os: active/passive current output (+HART ) passive pulse/status output passive status output passive status output / control input The l/0-module combination is thus 1-0-0 (see above). The TWS9000 with modular I/O can be tailor-made to any application: Suppose you require a converter with passive pulse output and 3 passive current outputs. The l/0-module combination then becomes B-B-B. Suppose you require a converter with 2 active pulse/status outputs. The l/0-module combination then becomes either 4-C- 8 or 8-C-8 (depending on whether active or passive current output is required). The latter '8' indicates that 1 additional module can be added in future.

Page 10 Example for combination of I/O s Basic I/O Ex-I/O 1 2 3 1 2 3 1 0 0 2 0 0 1 2 3 0 0 1 2 D 0 0 1 2 E 0 0 1 2 Modular I/O 1 2 3 1 2 3 1 2 3 4 8 8 8 8 8 D 8 8 A B B 8 A 8 A B A C C C G G K C 8 C 8 C 8 C C C G G K G 8 G 8 K 8 G G K 6 8 8 C 8 8 E 8 8 A 8 B 8 A 8 A B A E E C K K K E 8 E 8 C 8 E E C K K K K 8 H 8 K 8 K H K 7 8 8 C 8 8 F 8 0 A 8 B 8 A A B B F F C H H D F 8 F 8 E F F F H H G H 8 H 8 H H H K

Page 11 Dimensions and weights Dimensions [mm] Approx. weight Version (without cable / strip) L H W [kg] small 496.3 71 63.1 2.7 medium 826.3 71 63.1 3.6 large 496.3 1 71 1 63.1 1 2.7 1 Version Dimensions [inches] Approx. weight (without cable / strip) L H W [lbs] small 19.5 2.8 2.5 6.0 medium 32.5 2.8 2.5 7.9 large 19.5 1 2.8 1 2.5 1 6.0 1 1 Value for one of the 2 delivered rails

Page 12 1) TWS9000 W 2) TWS9000 F Version Dimensions [mm] Weight [kg] a b c f g h TWS9000 W 198 138 299 - - - 2.4 TWS9000 F 202 120 155 141 296 277 5.7 Version Dimensions [inches] a b c f g h Weight [lbs] TWS9000 W 7.8 5.4 11.8 - - - 5.3 TWS9000 F 7.75 4.75 6.1 5.5 11.6 10.9 12.6

Page 13 Dimensions [mm] Approx. weight a b c (without cable/metal [kg] Cable box 102 197 67 0.85 Dimensions [inches] Approx. weight a b c (without cable/metal [lbs] Cable box 4.01 7.76 2.64 1.87

Page 14 Ordering Information Contact your nearest Honeywell sales office, or In the U.S.: Honeywell Process Solutions Honeywell International Inc 2500 West Union Hills Drive Phoenix, AZ 85027 1-800-343-0228 In Europe and Africa: Honeywell S. A. Avenue du Bourget 1 1140 Brussels, Belgium In Asia: Honeywell Asia Pacific Inc. Honeywell Building, 17 Changi Business Park Central 1 Singapore 486073 Republic of Singapore In Canada: The Honeywell Centre 155 Gordon Baker Rd. North York, Ontario M2H 3N7 1-800-461-0013 In Eastern Europe: Honeywell Praha, s.r.o. Budejovicka 1 140 21 Prague 4, Czech Republic In the Pacific: Honeywell Pty Ltd. 5 Thomas Holt Drive North Ryde NSW Australia 2113 (61 2) 9353 7000 In Latin America: Honeywell Inc. 480 Sawgrass Corporate Parkway, Suite 200 Sunrise, FL 33325 (954) 845-2600 In the Middle East: Honeywell Middle East Ltd. Khalifa Street, Sheikh Faisal Building Abu Dhabi, U. A. E. In Japan: Honeywell K.K. 14-6 Shibaura 1-chrome Minato-ku, Tokyo, Japan 105-0023 Or, visit Honeywell on the World Wide Web at: http://www.honeywell.com Specifications are subject to change without notice.