Technical specification FLUXUS F502TE

Similar documents
Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

Technical specification FLUXUS F502BT

ISEmax CAM40/CAS40. Technical Information

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Field mounted Temperature Transmitter TF212/TF212-Ex

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

Pressure Measurement Single-range transmitters for general applications

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

SVH with HYDROVAR (HVL range)

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Ultrasonic Gas Flow Meter

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

EX-EMERGENCY LIGHT FITTINGS

Electromagnetic Flowmeter

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Conductivity sensor for hygienic applications

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

Operating Instructions for Digital Manometer. Model: MAN-SD

SLH-K Handheld Ultrasonic Flowmeter

A New Calibration Method for Ultrasonic Clamp-on Flowmeters

Capacitive Sensors. Contents

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

SYSTEM OF ELECTRONIC PUMPS IN CASCADE Heating Air conditioning 50 Hz

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

ATEX/IECEx RTD temperature probe

ED 701 General Industry Pressure Transmitter

Industrial Resistance Thermometers according to DIN Model MWD

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

Cooling Water Flow Regulator

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

TABLE OF CONTENT Designation code

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

Ex floating switches and Ex immersion probes

Metso Concentration Measurement 3300

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

Oscillation Flow Meter for Gases

Reflex-Radar BM 100 A

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

Pressure Transmitter ED 701

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

Linear actuator Econom 2. Our intelligent model: Econom 2. Econom 2

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Direct-operated 2/2-way solenoid valves Type EV210B

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

Surface-mounting Thermostats ATH Type Series

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97

VK2 volume flow controller Overview

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

Z7A. Load cells. Special features. Data sheet. Wiring code

Calio-Therm NC Type Series Booklet

HiPace 1200, with TC 1200, DN 200 CF-F

Application Your benefits

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

Thermal Mass Flow Meter for Gases

473 Dew Point Hygrometer

Automatic titrators, TitroMatic

Thermometers. Applications

Transcription:

Technical specification FLUXUS F502TE Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Precise and intelligent energy measuring system with extremely high measuring dynamic Features Integrated measuring system for the determination of thermal energy in real time For inner pipe diameters of DN 25...DN 500 High-precision temperature measurement using paired temperature probes (0.1 C temperature difference) Extremely high measuring dynamic > 100 : 1 Measures even the lowest flow velocities down to 0.01 m/s important for the measurement of low flow rates, e.g., during the night Permanent acoustic coupling of the ultrasonic transducers by long-lasting coupling pads; does not require further greasing and maintenance Support of standard bus systems FLUXUS F502TE Applications District heating Heating and cooling systems Heat interface units Distribution nets Building technology Heating and cooling systems Internal balancing Energy management Energy efficiency Energy monitoring Variofix L TSFLUXUS_F502TEV2-2-2EN_Leu, 2018-04-26

FLUXUS F502TE Technical specification Table of contents Function....................................................................................... 3 Measurement principle............................................................................. 3 Calculation of heat flow............................................................................ 4 Max. permissible error............................................................................. 4 Number of sound paths............................................................................ 5 Typical measurement setup......................................................................... 6 Transmitter..................................................................................... 7 Technical data................................................................................... 7 Dimensions...................................................................................... 9 2" pipe mounting kit............................................................................... 9 Terminal assignment............................................................................. 10 Transducers................................................................................... 11 Technical data.................................................................................. 11 Transducer mounting fixture........................................................................ 12 Coupling materials for transducers................................................................... 12 Connection systems.............................................................................. 13 Junction box................................................................................... 14 Technical data.................................................................................. 14 Dimensions..................................................................................... 14 2" pipe mounting kit.............................................................................. 14 Terminal assignment............................................................................. 15 Clamp-on temperature probe (optional)............................................................. 16 Technical data.................................................................................. 16 Fixation........................................................................................ 16 Junction box.................................................................................... 16 Inline temperature probe (optional)................................................................18 Technical data.................................................................................. 18 Fixation........................................................................................ 18 2

Technical specification FLUXUS F502TE Function Measurement principle The transducers are mounted on the pipe which is completely filled with the fluid. The ultrasonic signals are emitted alternately by a transducer and received by the other. The physical quantities are determined from the transit times of the ultrasonic signals. Path of the ultrasonic signal in the flowing fluid As the fluid where the ultrasound propagates is flowing, the transit time of the ultrasonic signal in flow direction is shorter than the one against the flow direction. The transit time difference, t, is measured and allows the flowmeter to determine the average flow velocity along the propagation path of the ultrasonic signals. A flow profile correction is then performed in order to obtain the area averaged flow velocity, which is proportional to the volumetric flow rate. Two integrated microprocessors control the entire measuring process. This allows the flowmeter to remove disturbance signals, and to check each received ultrasonic wave for its validity which reduces noise. Transit time difference t t 0 t Calculation of volumetric flow rate t V = k Re A k a ---------- 2 t where V - volumetric flow rate k Re - fluid mechanics calibration factor A - cross-sectional pipe area k a - acoustical calibration factor t - transit time difference t γ - average of transit times in the fluid TSFLUXUS_F502TEV2-2-2EN_Leu, 2018-04-26 3

FLUXUS F502TE Technical specification Calculation of heat flow The heat flow is internally calculated with the following formula: Φ = k i V (T V - T R ) (heating application) Φ = k i V (T R - T V ) (cooling application) where Φ heat flow k i heat coefficient V volumetric flow rate T V supply temperature T R return temperature The heat coefficient k i results from several heat flow coefficients for the specific enthalpy and density of the fluid. The heat flow coefficients of some fluids are stored in the internal database of the transmitter. Further user-defined fluids are possible. Max. permissible error The max. permissible error MPE of a complete heat meter is according to EN 1434 the arithmetic sum of the max. permissible errors of the subassemblies: calculator, temperature sensor pair and flow sensor. MPE = E c + E t + E f where MPE total max. permissible error E c max. permissible relative error of the calculator E t max. permissible relative error of the temperature sensor pair E f max. permissible relative error of the flow sensor 4

Technical specification FLUXUS F502TE Number of sound paths The number of sound paths is the number of transits of the ultrasonic signal through the fluid in the pipe. Depending on the number of sound paths, the following methods of installation exist: reflection arrangement The number of sound paths is even. Both of the transducers are mounted on the same side of the pipe. Correct positioning of the transducers is easier. diagonal arrangement The number of sound paths is odd. Both of the transducers are mounted on opposite sides of the pipe. In the case of a high signal attenuation by the fluid, pipe and coatings, diagonal arrangement with 1 sound path will be used. The preferred method of installation depends on the application. While increasing the number of sound paths increases the accuracy of the measurement, signal attenuation increases as well. The optimum number of sound paths for the parameters of the application will be determined automatically by the transmitter. As the transducers can be mounted with the transducer mounting fixture in reflection arrangement or diagonal arrangement, the number of sound paths can be adjusted optimally for the application. Reflection arrangement, number of sound paths: 2 a a - transducer distance Diagonal arrangement, number of sound paths: 3 a Diagonal arrangement, number of sound paths: 1 Diagonal arrangement, number of sound paths: 1, negative transducer distance a > 0 a < 0 TSFLUXUS_F502TEV2-2-2EN_Leu, 2018-04-26 5

FLUXUS F502TE Technical specification Typical measurement setup Example of a heat flow measurement measuring the volume flow rate in the return line supply line return line transducers temperature probe volumetric flow rate temperature probe supply temperature return temperature transmitter 6

Technical specification FLUXUS F502TE Transmitter Technical data FLUXUS F502TE-NN design field device with 1 measuring channel application energy meter transducers CDM2LZ7, CDP2LZ7, CDQ1LZ7 measurement energy max. permissible calculator: E c = ±(0.4 + 1 K/ θ) % relative error temperature temperature θ min = 3 K, θ max = 300 K difference max. permissible temperature sensor pair: E t - depending on type, see Technical data of temperature probes relative error flow measurement transit time difference correlation principle principle flow m 3 /h Q p = 15...6000 flow velocity m/s 0.01...25 fluid pressure without influence pressure loss - repeatability 0.25 % of reading ±0.01 m/s fluid water glycol/h 2 O: 20 %, 30 %, 40 %, 50 % max. permissible flow sensor: E f = ±2 % of reading ±0.01 m/s relative error transmitter power supply 100...230 V/50...60 Hz or 20...32 V DC or 11...16 V DC power consumption W < 10 number of measuring 1 channels damping s 0...100 (adjustable) measuring cycle Hz 10 response time s 1 housing material aluminum, powder coated degree of protection IP66 dimensions mm see dimensional drawing weight kg 1.9 fixation wall mounting, optional: 2" pipe mounting ambient temperature C -10...+60 display 2 x 16 characters, dot matrix, backlight menu language English, German, French, Dutch, Spanish, Polish, Czech measuring functions physical quantities heat flow, volumetric flow rate, flow velocity totalizer heat quantity, volume, mass communication interfaces process interfaces max. 1 option: RS485 (sender) Modbus RTU, sender (switchable) BACnet MS/TP, sender (switchable) M-Bus data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values remark with communication interface only in sender mode 1 for reference conditions and v > 0.25 m/s TSFLUXUS_F502TEV2-2-2EN_Leu, 2018-04-26 7

FLUXUS F502TE Technical specification FLUXUS F502TE-NN outputs The outputs are galvanically isolated from the transmitter. current output number 2 range ma 0/4...20 accuracy 0.1 % of reading ±15 μa active output R ext < 500 Ω binary output number 2 optorelay 28 V/100 ma binary output as alarm output functions limit, change of flow direction or error binary output as pulse output functions mainly for totalizing pulse value units 0.01...1000 pulse width ms 80...1000 inputs The inputs are galvanically isolated from the transmitter. temperature input number 2 type Pt100/Pt1000 connection 4-wire range C -150...+560 resolution K 0.01 accuracy ±0.01 % of reading ±0.03 K 1 for reference conditions and v > 0.25 m/s Max. permissible error of the calculator 1.5 1 0.5 Ec [%] 0-0.5-1 -1.5 0 10 20 30 40 50 50 θ [K] max. permissible error according to EN 1434, θ min = 3 K FLUXUS θ - temperature difference between supply and return line of the heat-exchange circuit 8

Technical specification FLUXUS F502TE Dimensions *502 ø8.4 thread: 4x M20 x 1.5 cable gland: max. 4x M20 ø4.5 205 10 103 140 71 83 fixing holes for wall mounting 220 in mm 2" pipe mounting kit *50* TSFLUXUS_F502TEV2-2-2EN_Leu, 2018-04-26 9

FLUXUS F502TE Technical specification Terminal assignment *502 AV AVS AGN ARS AR power supply 1 terminal connection (AC) connection (DC) PE earth earth N(-) neutral - L(+) phase + transducers, extension cable terminal connection transducer AV signal AVS internal shield ARS internal shield AR signal cable gland external shield outputs 1 terminal connection 1(-), 2(+) binary output B1 3(-), 4(+) binary output B2 5(-), 6(+) current output I1 7(-), 8(+) current output I2 communication interfaces 1 terminal connection communication interface 10 9 signal + signal - RS485 Modbus RTU BACnet MS/TP 11 shield M-Bus inputs 1 terminal temperature probe direct connection (clamp-on) connection with extension cable direct connection (inline) (clamp-on) TF1, TX1 red red red TF2, TX2 red/blue grey grey TF3, TX3 white/blue blue blue TF4, TX4 white white white 1 сable (by customer): lead cross sectional area: 0.25...2.5 mm 2 10

Technical specification FLUXUS F502TE Transducers Technical data Shear wave transducers (nonex) technical type CDM2LZ7 CDP2LZ7 CDQ2LZ7 transducer frequency MHz 1 2 4 nominal size min. DN 200 DN 80 DN 25 max. DN 500 DN 250 DN 100 pipe wall thickness min. mm 2 1 0.6 material housing PEEK with stainless steel cap 316Ti (1.4571) contact surface PEEK degree of protection IP67 transducer cable type 2606 length m 10, optional: 20 dimensions length l mm 59 36 width b mm 28 18 height h mm 31 21 dimensional drawing l b h weight (without cable) kg 0.066 0.024 ambient temperature min. C -40 max. C +100 Shear wave transducers (nonex, extended temperature range) technical type C(DL)M2N53 C(DL)P2N53 C(DL)Q2N53 transducer frequency MHz 1 2 4 nominal size min. DN 200 DN 80 DN 25 max. DN 500 DN 250 DN 100 pipe wall thickness min. mm 2 1 0.6 material housing PEEK with stainless steel cap 304 (1.4301 contact surface PEEK degree of protection IP67 transducer cable type 1699 length m 4, optional: 9 3, optional: 9 dimensions length l mm 64 40 width b mm 32 22 height h mm 40.5 25.5 dimensional drawing l h l b b h weight (without cable) kg 0.066 0.016 ambient temperature min. C -40 max. C +130 TSFLUXUS_F502TEV2-2-2EN_Leu, 2018-04-26 11

FLUXUS F502TE Technical specification Transducer mounting fixture tension straps, clasps and transducer shoes material: stainless steel 304 (1.4301), 303 (1.4305) tension strap length: 10 m transducers: CD*2LZ7 Variofix L (VLM, VLQ) material: stainless steel 304 (1.4301), 301 (1.4310), 410 (1.4006) inner length: VLM: 234 mm VLQ: 176 mm dimensions: VLM: 309 x 57 x 63 mm VLQ: 247 x 43 x 47 mm transducers: ***2*5* Coupling materials for transducers type ambient temperature material C coupling compound type N -30...+130 mineral grease paste coupling foil type VT -10...+200 fluoroelastomer 12

Technical specification FLUXUS F502TE Connection systems connection with extension cable direct connection transducers technical type JB05 *****53 x x transmitter transmitter x ****LZ7 transmitter x - transducer cable length l - max. length of extension cable Cable transducer cable type 2606 1699 weight kg/ m 0.033 0.094 ambient temperature C -40...+100-55...+200 cable jacket material PUR PTFE outer diameter mm 5 2.9 thickness mm 0.3 colour grey brown shield x x sheath material - stainless steel 316Ti (1.4571) outer diameter mm - 8 extension cable type 2615 max. length l m 90 weight kg/ m 0.18 ambient temperature C -30...+70 properties halogen free fire propagation test according to IEC 60332-1 combustion test according to IEC 60754-2 cable jacket material PUR outer diameter mm 12 thickness mm 2 colour black shield x TSFLUXUS_F502TEV2-2-2EN_Leu, 2018-04-26 13

FLUXUS F502TE Technical specification Junction box Technical data JB05 weight kg 1.2 kg fixation wall mounting optional: 2" pipe mounting material housing stainless steel 316L (1.4404) gasket silicone degree of protection IP67 ambient temperature min. C -40 max. C +80 Dimensions JB0x wall mounting holder 156 174 70 163.5 Ø 9 2 119 thread: 3x M20 x 1.5 cable gland: max. 2x M20 in mm 2" pipe mounting kit JBxx 14

Technical specification FLUXUS F502TE Terminal assignment JB05 transducers terminal strip terminal connection transducer KL1 TV signal TVS internal shield TRS internal shield TR signal cable gland external shield extension cable equipotential bonding terminal (at wall mounting holder) terminal strip terminal connection KL2 TV signal TVS internal shield TRS internal shield TR signal cable gland external shield TSFLUXUS_F502TEV2-2-2EN_Leu, 2018-04-26 15

FLUXUS F502TE Technical specification Clamp-on temperature probe (optional) Technical data PT12N type 2x Pt100 matched according to EN 1434 connection 4-wire measuring range C -30...+250 accuracy θ ±(0.15 C + 2. 10-3. T [ C] ) class A max. permissible relative error E t = 0.1 K (3 K < θ 6 K) E t = 0.2 K (6 K < θ 30 K) E t = 0.3 K (30 K < θ 50 K) response time s 50 housing aluminum degree of protection IP66 dimensions length l mm 15 width b mm 13 height h mm 20 dimensional drawing l h connection system connection with extension cable extension cable junction box direct connection connection weight kg 0.25 accessories thermal conductivity foil 250 C x b temperature probe red/blue red white/blue white сable temperature probe extension cable type 4 x 0.25 mm² black LIYCY 8 x 0.14 mm² grey standard length m 3 5/10/25 max. length m - 200 cable jacket PTFE PVC Fixation tension strap PT12N material: stainless steel 301 (1.4310), 410 (1.4006) Junction box JBT3 weight kg 1.2 kg fixation wall mounting optional: 2" pipe mounting material housing stainless steel 316L (1.4404) gasket silicone degree of protection IP67 ambient temperature min. C -40 max. C +80 16

Technical specification FLUXUS F502TE Dimensions JBTx wall mounting holder 156 174 70 163.5 Ø 9 2 119 thread: 3x M20 x 1.5 cable gland: max. 2x M12 in mm 2" pipe mounting kit JBxx Terminal assignment JBT3 temperature probe terminal strip terminal connection KL1 1 red 2 red/blue 3 white 4 white/blue extension cable equipotential bonding terminal (at wall mounting holder) terminal strip terminal connection KL2 1 red 2 grey 3 white 4 blue TSFLUXUS_F502TEV2-2-2EN_Leu, 2018-04-26 17

FLUXUS F502TE Technical specification Inline temperature probe (optional) Technical data PT12N-IT-P PT12N-IU-P type 2x Pt100 matched according to EN 1434 connection 4-wire measuring range C -30...+200 accuracy θ ±(0.15 C + 2. 10-3. T [ C] ) class A max. permissible % E t = ±0.9. (0.5 + 3. θ min / θ) relative error response time s T50: 5, T90: 19 housing 316Ti (1.4571) connecting head J: aluminum degree of protection IP65 dimensions length l mm 72 PT12N-IT-P: l E = 140 PT12N-IU-P: l E = 230 width b mm 51 dimensional drawing l E l connection сable temperature probe red red white white сable red grey blue white temperature probe type LIYCY 8 x 0.14 mm² grey standard length m 10/20 max. length m 200 cable jacket PVC b weight kg PT12N-IT-P: 0.136 PT12N-IU-P: 0.142 Fixation threaded thermowell PT12N l E PT12N-IT-P PT12N-IU-P mounting length l E mm 120 210 material threaded thermowell stainless steel 316L (1.4404) clamping nut zinc coated steel 1.0037, PTFE weight kg 0.08 0.091 outer diameter mm 8 process connection G 1/2 fluid pressure PN25 (water) max. flow velocity 1 water m/s 6.93 4.37 glycol/h 2 O m/s 8.4 3.78 1 max. permissible values for laminar flows; further influences like motors, pumps, valves which provoke turbulences, water hammers, pulsations, oscillations, etc. have to be considered by the customer 18

FLEXIM GmbH Boxberger Str. 4 12681 Berlin Germany Tel.: +49 (30) 93 66 76 60 Fax: +49 (30) 93 66 76 80 internet: www.flexim.com e-mail: info@flexim.com Subject to change without notification. Errors excepted. FLUXUS is a registered trademark of FLEXIM GmbH.