Introduction to Fluid Mechanics - Su First experiment: Flow through a Venturi

Similar documents
Measurements using Bernoulli s equation

PART 1B EXPERIMENTAL ENGINEERING. SUBJECT: FLUID MECHANICS & HEAT TRANSFER LOCATION: HYDRAULICS LAB (Gnd Floor Inglis Bldg) BOUNDARY LAYERS AND DRAG

ME 4600:483 Lab Notes Revised 11/16/2015. Flow Measurement

Chapter 3 Bernoulli Equation

ME332 FLUID MECHANICS LABORATORY (PART I)

Mass of fluid leaving per unit time

5 ENERGY EQUATION OF FLUID MOTION

Introduction to Aerospace Engineering

Lab Section Date. ME4751 Air Flow Rate Measurement

vector H. If O is the point about which moments are desired, the angular moment about O is given:

In which of the following scenarios is applying the following form of Bernoulli s equation: steady, inviscid, uniform stream of water. Ma = 0.

If a stream of uniform velocity flows into a blunt body, the stream lines take a pattern similar to this: Streamlines around a blunt body

Flow rate and mass flow rate

The E80 Wind Tunnel Experiment the experience will blow you away. by Professor Duron Spring 2012

Applied Fluid Mechanics

AEROSPACE ENGINEERING DEPARTMENT. Second Year - Second Term ( ) Fluid Mechanics & Gas Dynamics

Aerodynamics. Basic Aerodynamics. Continuity equation (mass conserved) Some thermodynamics. Energy equation (energy conserved)

Applied Fluid Mechanics

AER210 VECTOR CALCULUS and FLUID MECHANICS. Quiz 4 Duration: 70 minutes

Flow Measurement in Pipes and Ducts COURSE CONTENT

Sudden Expansion Exercise

Why do Golf Balls have Dimples on Their Surfaces?

Lab 1a Wind Tunnel Testing Principles & Drag Coefficients of Golf balls

Rapid Averaging Probe (RAP)

Given the water behaves as shown above, which direction will the cylinder rotate?

Chapter 7 The Energy Equation

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

Experiment (4): Flow measurement

CEE 3310 Control Volume Analysis, Oct. 7, D Steady State Head Form of the Energy Equation P. P 2g + z h f + h p h s.

3.25 Pressure form of Bernoulli Equation

Objectives. Conservation of mass principle: Mass Equation The Bernoulli equation Conservation of energy principle: Energy equation

Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras

Department of Energy Sciences, LTH

Detailed Outline, M E 320 Fluid Flow, Spring Semester 2015

STUDY OF BOUNDARY LAYER PARAMETERS ON A FLAT PLATE USING WIND TUNNEL

CHAPTER 3 BASIC EQUATIONS IN FLUID MECHANICS NOOR ALIZA AHMAD

for what specific application did Henri Pitot develop the Pitot tube? what was the name of NACA s (now NASA) first research laboratory?

EXPERIMENT No.1 FLOW MEASUREMENT BY ORIFICEMETER

Experimental Studies for Visualization of Flow with Boundary Layers in an Axial Compressor Fan Inlet using Pressure Probes

What is the velocity profile downstream of the sudden expansion? What is the relationship between the velocity profile and the flow rate?

Partner s Name: EXPERIMENT MOTION PLOTS & FREE FALL ACCELERATION

Chapter Four fluid flow mass, energy, Bernoulli and momentum

Steady waves in compressible flow

2.The lines that are tangent to the velocity vectors throughout the flow field are called steady flow lines. True or False A. True B.

Heat Transfer F12-ENG Lab #4 Forced convection School of Engineering, UC Merced.

Lecture-2. One-dimensional Compressible Fluid Flow in Variable Area

Experiment #4: Optical Spectrometer and the Prism Deviation

An Experimental Investigation to Control the Flow Emerging From a Wide Angle Diffuser

3.8 The First Law of Thermodynamics and the Energy Equation

Lab 8 Impulse and Momentum

Fluids. Fluids in Motion or Fluid Dynamics

Experiment No.4: Flow through Venturi meter. Background and Theory

Q1 Give answers to all of the following questions (5 marks each):

Lab 8 Impulse and Momentum

1. Introduction. Technical presentation of the Bernoulli Filter

AK-47/74 Barrel and Front Trunnion Rivet Removal

Lab 3 Acceleration. What You Need To Know: Physics 211 Lab

CEE 3310 Control Volume Analysis, Oct. 10, = dt. sys

Background Information for Use of Pitot Tube, Manometer, Hot Wires, and Hot Films

Millikan Oil Drop Experiment

TRANSPIRATION With LabQuest INTRODUCTION

PART II. Fluid Mechanics Pressure. Fluid Mechanics Pressure. Fluid Mechanics Specific Gravity. Some applications of fluid mechanics

CHEN 3200 Fluid Mechanics Spring Homework 3 solutions

Lecture 3 The energy equation

Chapter (6) Energy Equation and Its Applications

4. Dispersion. The index of refraction of the prism at the input wavelength can be calculated using

Therefore, the control volume in this case can be treated as a solid body, with a net force or thrust of. bm # V

TA guide Physics 208 Spring 2008 Lab 3 (E-1): Electrostatics

CHAPTER THREE FLUID MECHANICS

Pressure Measurement Techniques and Instrumentation

Lab Reports Due on Monday, 11/24/2014

MCE380: Measurements and Instrumentation Lab

FLUID MECHANICS PROF. DR. METİN GÜNER COMPILER

FLOW MEASUREMENT IN PIPES EXPERIMENT

ME3560 Tentative Schedule Spring 2019

Momentum (Newton s 2nd Law of Motion)

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

1.060 Engineering Mechanics II Spring Problem Set 3

Experiment 3 The Simple Magnifier, Microscope, and Telescope

The radial pressure gradient for turbulent flow in smooth pipes

Thermodynamics. We can summarize the four laws of thermodynamics as follows:

Solar Energy Cooking with the Sun

Iran University of Science & Technology School of Mechanical Engineering Advance Fluid Mechanics

11.1 Mass Density. Fluids are materials that can flow, and they include both gases and liquids. The mass density of a liquid or gas is an

Lab: Electric Potential & Electric Field I

ME3560 Tentative Schedule Fall 2018

Atomic Spectra HISTORY AND THEORY

1.060 Engineering Mechanics II Spring Problem Set 4

Please welcome for any correction or misprint in the entire manuscript and your valuable suggestions kindly mail us

6.1 Momentum Equation for Frictionless Flow: Euler s Equation The equations of motion for frictionless flow, called Euler s

the pitot static measurement equal to a constant C which is to take into account the effect of viscosity and so on.

ME 431A/538A/538B Homework 22 October 2018 Advanced Fluid Mechanics

ME332 FLUID MECHANICS LABORATORY (PART II)

Chapter 4 DYNAMICS OF FLUID FLOW

Unit 2: Electrostatics

Fluid Mechanics. du dy

PHYS 3324 Lab Millikan Oil Drop Experiment: Demonstration of the Quantization of Charge

Lab #4 Similitude: The Kármán Vortex Street CEE 331 Fall 2004

Republic of Iraq Ministry of Higher Education and Scientific Research University of Technology- Electromechanical Department

DETERMINATION OF DISCHARGE AND HEAD LOSS USING A FLOW-MEASURING APPARATUS

Transcription:

530.327 - Introduction to Fluid Mechanics - Su First experiment: Flow through a Venturi 1 Background and objectives. In this experiment, we will study the flow through a Venturi section using both flow visualization and pressure measurements. A Venturi is basically a converging-diverging section (like an hourglass), typically placed between tube or duct sections with fixed cross-sectional area. We will see in class how, for example, the flow rate through a Venturi can be related to pressure measurements, using Bernoulli s equation. Here we will explore the use of Bernoulli s equation over a range of flow conditions, paying particular attention to the validity of the assumptions behind the derivation of Bernoulli s equation. In particular, in deriving Bernoulli s equation we assume that the flow in question is (I) inviscid, (II) steady, and (III) incompressible. It turns out that conditions (II) and (III) are fairly easy to guarantee in a Venturi, but that (I) can be problematic. This is particularly true when the area ratio is large, i.e. when the narrowest part of the Venturi (variously known as the throat or the waist ) is much smaller than the widest part. The culprit is a phenomenon known as flow separation. Consider a streamline that is very close to the wall in a Venturi. An inviscid fluid will have no trouble following the contour of the wall. Provided that the area change is gradual enough and that the flow speeds are low enough, a real, viscous fluid will also easily follow the wall, and the behavior of such a real fluid can be treated as being a good approximation to the behavior of an inviscid fluid. However, as the area change becomes more abrupt and/or the flow speed increases, the situation changes; downstream of the throat, a real fluid will become unable to turn sharply enough away from the centerline to follow the wall. The term flow separation means that the flow streamlines no longer remain attached to the contours of the wall, as depicted in Fig. 1. Flow separation arises due to viscous effects in fluids, Figure 1: Flow separation from a curved wall. The flow is from left to right. The smooth streamlines that are evident on the upper part of the image clearly do not follow the sharp downward curve of the wall, i.e the streamlines separate from the wall. so any time flow separation is present in a flow, Bernoulli s equation is automatically invalidated. This experiment has two parts: We will observe the flow pattern in a Venturi section with adjustable throat area, paying particular attention to the presence of any flow separation. We will measure pressures and velocities in the Venturi, and compare the results with the predictions of Bernoulli s equation. 1

2 Experimental apparatus. The experiment will use one of the wind tunnels in Krieger B-2 (the one further from the main entrance). Figure 2 shows the test section. The upper and lower walls of the Venturi are constructed Tunnel outlet Test section Slant-tube manometer Pressure manifold Figure 2: The wind tunnel test section, showing the static pressure ports, the pressure manifold, and the manometer to be used for pressure measurements. The tunnel flow is from right to left. of flexible metal sheet. The width of the throat can be adjusted using control wheels mounted on threaded rods. Pressure measurement. Figure 2 shows the slant-tube manometer (water is the working fluid) by which we will measure pressures. Make sure you understand the principle of the manometer, which was discussed in Ch. 3 in the text (for example, which side of the manometer should be connected to higher pressures, and which to lower pressures?). The figure also shows the line of 11 pressure ports along the centerline of test section. The most upstream pressure port is located essentially in the parallel part of the tunnel (before the Venturi). This port (call it port 0) is connected to a flexible tube that can be connected directly to the manometer. The remaining 10 ports (ports 1 10) are connected to a pressure manifold that is connected to a single flexible tube; asystemofvalvesallowstheusertoselectthespecificporttobeused. On the back side of the test section, there are 11 holes located at the same downstream positions as the pressure ports on the front side, through which a Pitot-static probe can be inserted for the measurement of dynamic pressure. Figure 3 shows the configuration of our probe; again, make sure you understand the theory of the Pitot-static probe, discussed in Ch. 6 in the text. Stagnation pressure is sensed through the hole at the tip of the probe, while static pressure is sensed through the ring of holes that lie a little bit downstream the probe tip. The same manometer used for the static pressure measurements will be used for the stagnation pressure measurement. When using the manometer, keep these things in mind: Make sure to establish the reference fluid level in the manometer, i.e. the level when both sides are exposed to the same pressure. You can move the graduated scale to set the reference level somewhere convenient. Confirm that the manometer is level. If it isn t, shim it up to level using the scraps of paper provided for this purpose. Be consistent in defining the measurement point on the meniscus. It may be easiest to assign one member of your lab group to this task for the entire experiment. 2

Incoming flow Holes for static pressure measurement To static pressure readout To stagnation pressure readout Figure 3: The Pitot-static probe used for dynamic pressure measurements. The hole at the upstream tip of the probe senses stagnation pressure, while a ring of holes just downstream of the tip sense static pressure. In this lab we will measure the dynamic pressure by reading the difference between the stagnation and static pressures directly using the slant-tube manometer. Let the fluid level stabilize somewhat before taking each reading, but be aware that it won t stabilize completely; you will need to estimate the proper value through a small range of fluctuations. Don t take too long with each reading. Time is tight in this lab. Flow visualization. For the flow visualization, we will use the fog generation apparatus described in the separate handout. For this lab, there is one change from the handout the apparatus has been modified to generate two fog streams instead of four. 3 Experimental procedure. Preliminaries. (Target time: 5 minutes.) In order to perform this experiment efficiently, it is a good idea to distribute tasks among the different group members. There are four preliminary tasks to get out of the way. 1. Read the atmospheric pressure in the room, using the mercury barometer on the wall of the lab, in the corner of the room just to the right of the entrance. The TA can help you with this. Get the temperature from the thermometer located there also. You will use this information to estimate the air density. 2. Warm up the fog machine, as described in the handout. 3. Record the geometric parameters of the test section. Measure the height and width of the interior of the test section (ignore the Venturi walls for now), and measure the spacing between the pressure tap holes. 4. Adjust the Venturi walls so that the throat is 5 wide, and symmetric about the test section centerline. (There is a ruler mounted on the side wall of the tunnel to help you do this.) Flow visualization. (Target time: 20 minutes.) In this part of the experiment you will use the fog apparatus to make purely qualitative observations of the flow through the Venturi. Each group member should record his/her observations individually. 3

1. Turn on the tunnel by flipping the switch on the control box, and set the speed to 50 on the rotary dial. (Note: if you ever need to turn the tunnel off, always return the rotary dial to zero before flipping the switch to off.) 2. With the fog machine warmed up, turn on the fog supply as described in the handout. Move the fog apparatus so the output holes on the fog plenum are almost touching the tunnel inlet screen. 3. To see the fog go through the tunnel, it is helpful to turn down the room lights and use the desk lamp to illuminate the test section. Adjust the light to minimize glare from your vantage point. You may need to stare at the test section for a short time before your eye can make out the fog, since the contrast will be low. What can you say about the streakline pattern, both upstream and downstream of the throat? A particularly good view of the streaklines can be had by having one group member shine the desk lamp on the test section, while the others look down the tunnel through the fan end. 4. Increase the tunnel speed to 70 on the dial. Repeat your observations. 5. In your recorded observations, pay particular attention to any evidence of flow separation, or streaklines that become wavy, etc. 6. If you have time, set the Venturi throat width to 2 and repeat the above. 7. Shut down the fog machine after your observations are finished. Pressure and velocity measurements. (Target time: 50 minutes.) In this part of the experiment you will measure pressures and velocities in the Venturi, and you will use these results to assess quantitatively the validity of Bernoulli s equation for this flow, along with the assumption of a one-dimensional velocity distribution. 1. Set the tunnel speed to 70, and the Venturi throat width to 5. 2. Begin with static pressure measurements using the pressure manifold. Connect port 0 to the low-pressure side of the slant-tube manometer, and leave the high-pressure side open to the atmosphere (whose pressure you already know). Remember to ensure that the manometer is level. Record the gage pressure at port 0. Then connect the pressure manifold to the lowpressure side of the manometer, and record the gage pressure at each of the ports 1 through 8only. Make sure the valves are fully open (the manometer level equilibrates faster that way), but note that you don t have to gorilla-tighten them to make sure they re closed. Not everyone needs to record all data, but everyone in the group needs access to the data for the write-up. 3. While the pressure measurements are going on, someone else can measure the Venturi width, h i (i.e. the distance between the top and bottom walls of the Venturi), corresponding to each of the pressure tap locations i (this is best done on the opposite wall from the pressure manifold). 4. Having completed the static pressure measurements, connect the Pitot-static probe to the manometer (the flexible tube that is colinear with the body of the probe gives the stagnation pressure, and the perpendicular tube gives the static pressure). You can leave the manometer where it is. Take dynamic pressure measurements at ports 1 10 (not port 0). Try to keep the probe in the horizontal plane and make sure the business end faces directly upstream. You will note that at port 1, the probe can t be pushed in flush with the side wall because the 4

flange on the test section is in the way. To be consistent, for ports 2 10, only push the probe in as far as you can for port 1. There is a piece of tape on the probe that helps you do this. 5. Important: When the Pitot-static probe is inserted in a given port, you ll notice that the stagnation and static pressures are actually being measured some distance upstream of that port. Assume that the dynamic pressure read on the manometer corresponds to a point halfway between the stagnation and static pressure sensing holes, and record how far upstream that point is from the port being used. 6. Reduce the tunnel speed to 50, leave the throat width at 5, and repeat steps 2 and 4. 7. Adjust the throat to a 2 width (symmetric about the centerline), and return the tunnel speed to 70. Repeat steps 2, 3 and 4. 8. Reduce the tunnel speed to 50 and leave the throat width at 2. Repeat steps 2 and 4. 9. When the measurements are complete, shut off the tunnel and (if Lester is serving as your TA) make sure everything else is in the condition you found it, otherwise hightail it out of there and leave janitorial tasks to the TA. Formal lab report. Guidelines for the formatting and style requirements of the formal report are in a separate handout. The report should include the following observations and data analyses. Summarize your observations from the flow visualization portion. Say something about the possibility or observed presence of flow separation. Make sure you understand exactly what is meant by flow separation. Convert your dynamic pressure data to velocities. Interpolate your results (linear interpolation is fine) to get the velocity values, V i, that correspond directly to the locations of the pressure ports, i. (Explain why we didn t bother to measure static pressure at the two most downstream ports.) For each case (tunnel speed and throat width), plot the mass flow rate, calculated as ρv i A i,wherea i is the Venturi section area at each port location, versus i. This is a check on the assumption of uniform velocities at each section (why?). Using port 0 as the reference value, calculate and plot the percent error in the mass flow rate measurements. Comment on your results. Use the velocities, V i, together with the gage static pressures, p i,g, to evaluate the Bernoulli constant: B i = p i,g ρ + 1 2 V 2 i (1) at each port position where you have data available. Plot your results. Think of a good way to evaluate the accuracy of the assumption that B i is a constant. Display your results and comment. Discuss your quantitative results in light of the possibility of flow separation. 5