Product Descriptions and Offerings

Similar documents
110 Lowell Rd Hudson, NH USA Tel:

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

Determination of the Halogen Elements in the Deep UV Region of the Spectrum by ICP - OES

Hydra-C Application Note: 1076

The Evolution of Inductively Coupled Plasma - Optical Emission Spectroscopy (ICP-OES)

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

U.S. EPA SW-846 Method 6010C Using the Prodigy7 High- Dispersion ICP Introduction. Application Note - AN1305. Experimental

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Analysis of domestic sludge using the Agilent 4200 MP-AES

DI 3500 Discrete Aoalvzer

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Defining quality standards for the analysis of solid samples

OPTIMIZING METALS SAMPLE PREP

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Automated Clinical Analyzer

DMA-80L TECHNICAL SPECIFICATIONS

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

LIBSlab ANALYZERS ANALYZERS

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Test Method: CPSC-CH-E

Atomic Absorption Spectrometer ZEEnit P series

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Mercury Determination in Lichen, BCR-482, Using the QuickTrace M-7600 CVAAS Mercury Analyzer

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

Basic Digestion Principles

ALPHA. Innovation with Integrity. The very compact and smart FTIR spectrometer FTIR

Prof. Dr. Biljana Škrbić, Jelena Živančev

ICP-OES Application Note Number 35

Mercury Stack Monitor SM-4

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

novaa 800 D Atomic Absorption Spectrometer

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques

PRINCIPLE OF ICP- AES

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Application field / Industry branch:

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

Member of the envea Group. Automatic Mercury Analyzer for the Laboratory

Ideal and powerful solution

Laird Thermal Systems Application Note. Precise Temperature Control for Medical Analytical, Diagnostic and Instrumentation Equipment

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

TOXICOLOGY & FORENSIC APPLICATIONS

2101 Atomic Spectroscopy

Fusion UV/Persulfate TOC Analyzer

Sources of Errors in Trace Element and Speciation Analysis

á233ñ ELEMENTAL IMPURITIES PROCEDURES

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

Analytical Instrumentation

AULA 254 AULA Fluorescence

AUTOMATED CHROMATOGRAPHY SYSTEMS. Featuring EZ Prep

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Elemental analysis by X-ray f luorescence. High performance EDXRF elemental analyzer

Application note. Determination of exchangeable cations in soil extracts using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer

The Clinical Chemistry System that offers more so you do less!

The Investigation of Fertilizer Analyses Using Microwave Digestion and the Agilent 720-ES

Your partner in Science!

a. An emission line as close as possible to the analyte resonance line

IN QUALITATIVE ANALYSIS,

Maintenance with OQ. ZEEnit 700. Operational Qualification OQ within the scope of a maintenance for the. Atomic Absorption Spectrometer

ATOMIC SPECTROSCOPY APPLICATIONS IN THE CONTRACT ENVIRONMENTAL LABORATORY. Primer July 2015 Edition

The challenges of field sensors for trace metal detection. Chris Searle Product Manager Trace2o Ltd

OptiMass 9500 ICP-oTOFMS. Orthogonal Time-Of-Flight The World s Fastest Benchtop ICP Mass Spectrometer. SCIENTIFIC EQUIPMENT

Humidity Calibration Solutions

Authors: C. Derrick Quarles, Jr. *, Patrick Sullivan, M. Paul Field, Hwan Kim, and Daniel R. Wiederin

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

Atomic Spectroscopy AA/ICP/ICPMS:

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

NaturalFacts. Introducing our team. New product announcements, specials and information from New Roots Herbal. April 2009

HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE

Introduction to Fourier Transform Infrared Spectroscopy

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Spectroscopy Problem Set February 22, 2018

Mining Analyzer XRF-3360

for XPS surface analysis

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Level. Automate your processes Automate your lab Innovate with. sensing. EasyPREP. sample handler. Automated Sample Preparation.

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Traceable UV-Vis Reference Materials

Agilent Cary 630 FTIR sample interfaces combining high performance and versatility

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

SMARTCHEM 200 STATE-OF-THE-ART DIRECT READ DISCRETE ANALYZER FOR AUTOMATED CHEMISTRIES

Translational Biomarker Core

JAPAN QUALITY. Automated Clinical Analyzer

Fusion UV/Persulfate TOC Analyzer

Simple and Reliable Soil Analysis using the Agilent 7800 ICP-MS with ISIS 3

Analytical Instruments

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

SKALAR. your partner in chemistry automation. The San ++ continuous flow analyzer

University Wet Chemistry Analyzer Packages

UV3000. Accurate, precise, and portable ambient gas point analyzer

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Application of Selenium Speciation Analysis to Elucidate Limitations with Accepted Total Selenium Methods

Transcription:

Product Descriptions and Offerings

Teledyne Leeman Labs is a leading innovator of analytical instrumentation for elemental analysis. Laboratories in industries ranging from environmental science, oil and gas, food, agriculture, earth sciences, clinical chemistry, and industrial materials rely on our instrumentation due to their exceptional accuracy, reliability, and durability. Teledyne Leeman Lab s analytical instruments play a vital role in protecting the environment, maintaining the integrity of our food and water supply, ensuring the safe operation of our factories and the quality of manufactured goods. Leeman Labs is best known for its first use of the echelle spectrometer for Inductively Coupled Plasma (ICP) Spectrometers, and for its innovations in stand-alone mercury analysis equipment. In the area of Hg analysis, they pioneered groundbreaking ways to automate both sample preparation and testing, enabling the chemist to get more done in less time.

Family of Mercury Analyzers Teledyne Leeman Labs family of Mercury Analyzers are fully automated instruments that address the analysis of solids, semi-solids and liquids. They are equipped to assist today s laboratory technician, chemist or lab manager in meeting the myriad of challenges that face today s modern laboratory. These high-performance fully automated analyzers are the number one choice for laboratories searching for a mercury analyzer with a proven track record. Hydra II AA - Atomic Absorption Detection for Liquid Samples Delivers both the performance needed to meet tightening regulatory demands and the productivity needed for laboratories to operate efficiently. Its 5.0 ng/l detection limits, exceptional stability and unique over-range protection easily satisfy the most stringent QCs. Its high capacity autosampler with extra large CCV/CCB containers permits long periods of unattended operation. High sampler capacity (up to 270 sample locations) Large reservoirs for recurring QCs Easily handles difficult sample matrices Automatic over-range protection Hydra II C - Atomic Absorption Detection Direct Analysis of Solid and Semi Solid Samples Eliminates the complicated chemistry and hazardous waste associated with conventional mercury techniques. The Hydra II C is ideal for analysis of solid to semi-solid samples in a myriad of settings. 70 position autosampler On-the-fly sample programming Exceptionally easy to maintain

Family of Mercury Analyzers QuickTrace M-7600 - CVAA mercury analyzer system - ranges from ultra-trace to sub mg/l analysis Easily achieves the ultra-trace mercury detection limit of < 0.5 ng/l demanded by customers employing performance based EPA method 245.7. The QuickTrace M-7600 is ideal for ultra-trace to sub-mg/l mercury quantitation. The M-7600 is designed for routine and research use in a variety of settings, including environmental laboratories, industry, and research institutes, for virtually any aqueous acidified sample. U.S. EPA 245.7 compliant 0.5 ng/l instrument detection limits Usable range, 0.5 ng/l 500 µg/l Advanced contamination control, over range and smart rinse features Smart Rack technology QuickTrace M-8000 - CVAF system for triple mode, no enrichment, single or double gold amalgamation Ideal for ultra-trace to sub-mg/l mercury quantitation. It easily achieves the ultra-trace mercury detection limit of < 0.05 ng/l demanded by customers employing EPA method 1631. The QuickTrace M-8000 is also versatile enough to analyze samples > 400 µg/l in a research or industrial setting without dilution. U.S. EPA 1631 and 245.7 compliant 0.05 ng/l instrument detection limits Advanced contamination control, over range and smart rinse features Intuitive pump and carrier gas controls eliminating air infusion into the system during sample probe movements Smart Rack technology

Inductively Coupled Plasma Optical Emission Spectrometers (ICP-OES) At Teledyne Leeman Labs atomic spectroscopy is our business, our only business. We are deeply committed to providing technically superior products and the highly responsive support you need to meet or exceed your elemental analysis needs. Teledyne Leeman Labs ICP-OES instruments offer industry leading performance, a wide range of sample introduction options, high throughput automation, the ability to analyze samples with reduced gas consumption. Configurations for any sample type: Radial for ppm to percent level analysis Axial for ultra-trace measurements Dual View for the widest possible concentration ranges Prodigy7 Low Format, Advanced CMOS Array Detector Full Wavelength Coverage Full Spectral Access Twist-n-Lock, Auto-Aligning Sample Introduction System Compact Design Reduced Gas Consumption

Inductively Coupled Plasma Optical Emission Spectrometers (ICP-OES) Prodigy Advanced Analysis Capability Halogen, Time Resolved Spectroscopy and Laser Ablation Options Large Format Programmable Array Detector Suitable for the most basic applications to the most complex Prodigy XP Composite Programmable Array Detector (C-PAD) Image Stabilized Plasma Full Wavelength Coverage Low Stray Light Optics

DC Arc Fast, quantitative, elemental analyses of difficult samples are hallmarks of the DC Arc approach. Few other techniques can challenge the ease-of-use or productivity of DC Arc when it comes to samples that are difficult or impossible to digest. Prodigy DC Arc performs elemental analysis of samples in their native form without sample digestion. When it comes to copper analysis, DC Arc continues to be the preferred technique for the routine analysis of trace elements in a high purity copper matrix. Typical applications: Acquires the full high resolution spectrum in a single burn Uses half the number of electrodes which cuts your cost and analysis time in half High purity metals: ex. copper High purity powders: ex. oxides, carbides, graphite Precious metals Nuclear materials Geologicals

110 Lowell Rd Hudson, NH 03051 USA Tel: 603-886-8400 www.teledyneleemanlabs.com