Supplementary Information

Similar documents
Supplementary Information for Microfluidic Magnetophoretic Separations of Immunomagnetically Labeled Rare Mammalian Cells

Postprint.

Cruz, J., Hooshmand Zadeh, S., Wu, Z., Hjort, K. (2016) Inertial focusing of microparticles and its limitations. In: (pp. 1-6).

Supporting Information: PDMS Nanocomposites for Heat Transfer Enhancement in. Microfluidic Platforms

Application Note Antibody-SOMAmer Sandwich Assay

Geometry Induced Microparticle Separation in Passive Contraction Expansion Straight Channels

Experimental measurement of parameters governing flow rates and partial saturation in paper-based microfluidic devices

A Multifunctional Pipette

Supplementary Methods

Particle concentration influences inertial focusing in Multiorifice Flow Fractionation microfluidic devices

Electronic Supplementary Information. Methods

Supporting Information. Technique for real-time measurements of endothelial permeability in a

Supplementary Information for Engineering and Analysis of Surface Interactions in a Microfluidic Herringbone Micromixer

Methods. Casting Mold Fabrication. Channel Fabrication. Sample assembly

Spherotech, Inc Irma Lee Circle, Unit 101, Lake Forest, Illinois PARTICLE COATING PROCEDURES

Figure S1. Steps in the fabrication of the PEO-coated nanochannel array.

Electronic Supplementary Information

Supplementary Methods

Quantification of NS1 dengue biomarker in serum via optomagnetic nanocluster detection

A microfluidic-based hydrodynamic trap: Design and implementation

ENMA490 Capstone: Design of Microfluidics Mixer

Electronic Supplementary Information

SUPPLEMENTAL MATERIAL I: SEM IMAGE OF PHOTONIC CRYSTAL RESONATOR

SUPPLEMENTARY FIGURES

Detection limit: grain, feed 500 ppb; milk 50 ppb; cream, cheese 5 ppb

Supplementary Material (ESI) for Journal of Analytical Atomic Spectrometry This journal is The Royal Society of Chemistry 2010

Electronic Supplementary Information. Continuous Flow Microfluidic-MS System for Efficient OBOC Screening

SUPPORTING INFORMATION. Si wire growth. Si wires were grown from Si(111) substrate that had a low miscut angle

Supplementary Figure 1 a) Scheme of microfluidic device fabrication by photo and soft lithography,

Supporting Online Material. On-Chip Dielectrophoretic Co-Assembly of Live Cells and. Particles into Responsive Biomaterials

Supplementary Information

Standardization of Optical Particle Counters

Supplementary information Full range physiological mass transport control in 3D tissue cultures

Preparing the sample for determination of Viability

camp Direct Immunoassay Kit

Quantitative dynamic footprinting microscopy reveals mechanisms of neutrophil rolling

Ultrasonic particle and cell separation and size sorting

Supporting Information

Precision and accuracy of protein size determination using the ActiPix TDA200 Nano-Sizing System

Quantification Strategies Using the High Sensitivity Protein 250 Assay for the Agilent 2100 Bioanalyzer. Technical Note. Abstract

[Supplementary Figures]

Electronic Supplementary Information. Microfluidic System Incorporated with Peptide/Pd Nanowires for Heterogeneous Catalytic Reactions

Supporting Materials Ultra-small Sub-10 nm Near Infrared Fluorescent Mesoporous Silica Nanoparticles

Imaging based optofluidic air flow meter with polymer interferometers defined by soft lithography

LITERATURE SURVEY SUMMARY OF HYPERELASTIC MODELS FOR PDMS

Inserting grids into capsule Removing capsules from grid box Immunolabeling using template guide Preparing for TEM insertion

3.032 Problem Set 4 Fall 2007 Due: Start of Lecture,

Supporting Information

Multi-Physics Analysis of Microfluidic Devices with Hydrodynamic Focusing and Dielectrophoresis

In Situ Gelation-Induced Death of Cancer Cells Based on Proteinosomes

Protocol for Minichip hybridization. Equipment and Reagents needed: BLOCKING SOLUTION (2% [w/v]) CY-3 STREPTAVIDIN

Fluorescent Labeling and Tracking of Nanoclay

Supplementary Figures

specified quantity of a solvent at a given temperature. To deconvolute the value from the

Supplementary information for

Probing Liquid Surfaces under Vacuum Using SEM and ToF-SIMS Supplementary materials

Nitric Oxide Synthase Assay Kit

09/07/16 12/07/16: 14/07/16:

For the quantitative measurement of PEGylated molecules in plasma, serum and cell culture media

DRG International, Inc., USA Fax: (908)

A gas-phase amplified quartz crystal microbalance immunosensor based on catalase modified immunoparticles

Nanomaterials and Chemistry Key Laboratory, Wenzhou University, Wenzhou, (P. R. China).

Supporting Information

Lecture 18: Microfluidic MEMS, Applications

Positioning a single Metal Organic Framework particle using the magnetic field.

Technical Bulletin. Caspase 13 Fluorescein (FLICA) Assay. Catalog Number CS0320 Storage Temperature 2-8 C

Manufacturing of Anisotropic Particles by Site Specific Oxidation of Thiols

Polyethylene Glycol (PEG), High Sensitive ELISA

Calculate the total volumes of the following typical microfluidic channel dimensions.

High Sensitivity Polyethylene Glycol (PEG) ELISA Kit

Human papillomavirus,hpv ELISA Kit

Electronic Supplementary Information


Pinched Flow Fractionation: Continuous Size Separation of Particles Utilizing a Laminar Flow Profile in a Pinched Microchannel

An image depicting a 48-well plate comprising 48 individual electrochemical cells

Hydrodynamics of Diamond-Shaped Gradient Nanopillar Arrays for Effective. DNA Translocation into Nanochannels. (Supplementary information)

Microfluidics 1 Basics, Laminar flow, shear and flow profiles

11,12-EET/DHET ELISA kit

Spectrum-resolved Dual-color Electrochemiluminescence Immunoassay for Simultaneous Detection of Two Targets with Nanocrystals as Tags

RayBio Human IDUA ELISA Kit

Bottom-up Optimization of SERS Hot Spots. Supplementary Information

RayBio CaspGLOW TM Fluorescein Active Caspase-3 Staining Kit

Fluidic low pass filter for hydrodynamic flow stabilization in microfluidic environments

Problem 4.3. Problem 4.4

Chemiluminescence excited photoelectrochemistry using graphene-quantum dots nanocomposite for biosensing

Superoxide Dismutase Activity Assay Kit

Microfluidic Assisted Self-assembly of Chitosan based Nanoparticles as Drug Delivery Agents

Mapping of Deformation to Apparent Young s Modulus in Real-Time Deformability Cytometry. Christoph Herold

RayBio Human Thyroid Peroxidase ELISA Kit

56.2: Invited Paper: Pixel-Isolated Liquid Crystal Mode for Plastic Liquid Crystal Displays

IgG (Chicken) ELISA Kit

Monkey Kidney injury molecule 1,Kim-1 ELISA Kit

Comparative Analysis of Protein Recovery Rates in Eppendorf LoBind and Other Low Binding Tubes

Computational Analysis for Mixing of Fluids Flowing through Micro- Channels of Different Geometries

OESTREICH LAB CHIP PROTOCOL

Additional Materials Required (NOT PROVIDED): 200 µl; anti-ifn-ω monoclonal (murine) antibody Streptavidin-HRP* 150 µl

Rapid formation of size-controllable multicellular spheroids. via 3D acoustic tweezers

NANO 243/CENG 207 Course Use Only

Supporting Information

Solution-processable graphene nanomeshes with controlled

Transcription:

Device Fabrication Fig. S. Microfluidic devices consisted of a polycarbonate membrane sandwiched between two PDMS channels, following the technique described by Chueh et al. Anal Chem, 79, 50508, (007). 5 (a) Channels were cm long with independent inlets and outlets for top and bottom. (b) The top channel was 00 μm high, while the bottom channel was 50 μm high. The bottom channel was taller than the top channel to allow fluid permeation through the membrane. Both channels were mm wide. (c) Polycarbonate membranes (GE Whatman, Piscataway, NJ) were 0 μm thick, with an average pore size of ~00 nm and 0% porosity.

Fig. S. (a) Negative photoresist (SU8, MicroChem, Newton, MA) was photolithographically patterned on silicon wafers to create masters. The masters were then used as molds, on which polydimethylsiloxane (PDMS) prepolymer (Sylgard 8, Dow Corning, Midland, MI) mixed with its crosslinker at 0: (Sylgard, 8, Dow Corning) weight ratio was poured, degassed, and allowed to cure in a conventional oven at 65 ºC for h before removal from the molds. (b) Next, a thin layer of uncured PDMS diluted in toluene (50% v/v) (Sigma Aldrich, St. Louis, MO) was spun 800 rpm for min onto a glass slide using a highspeed spinner. (c) The thin layer of PDMS was transferred onto the channel surfaces by gently stamping the PDMS channel onto the uncured PDMS. (d) The polycarbonate membrane(ge Whatman) was gently placed over the bottom channel first and then the top channel was carefully aligned over it. (e) The device constructs was allowed to sit at room temperature overnight to cure at 70 C. The polycarbonate membranes were then covalently functionalized with AntiEpCAM (R&D Systems, Minneapolis, MN) or IgG (0 μg/ml) (R&D Systems) using a method previously described by Suye et al., Biotechnol. Appl. Biochem, 7, 58 (998). Briefly, after glutaraldehyde (Electron Microscopy Services, Hatfield, PA) incubation of the microfluidic channel, the device was thoroughly washed with phosphate buffer saline (Invitrogen, Carlsbad, CA) and incubated with 0 μg/ml of Avidin (Thermo Scientific, Rockford, IL). The device was then washed with buffer and the top channel of the device was then incubated with biotinylated antiepcam or IgG for hours. The antibody was washed with phosphate buffer and the device was incubated with 5% Pluronic F08 (Fisher Scientific, Pittsburg, PA) in % BSA (Sigma Aldrich) in order to reduce nonspecific binding of cells.

Sample Preparation Leukocytes ( buffy coat ) were isolated from whole blood using deterministic lateral displacement () and resuspended to a concentration of 500,000/mL. These cells were fluorescently labeled (CellTracker calcein green, Invitrogen) following the manufacturer protocol. PC human prostate cancer cells (ATCC) were cultured at 7ºC and 5% CO in FK growth media containing.5 mm Lglutamine supplemented with 0% FBS and % Penicillin/Streptomycin, with media changes every days. These cells were labeled with a different fluorescent dye (Cell Tracker Orange, Invitrogen) and spiked into the sample at a ratio of :50 (000/mL). The PC spike count was verified immediately before addition to the buffy coat population as well as before loading the sample into the device. These readings were consistent to within 5%. After capture, cells were nuclear stained with DAPI (Invitrogen) following manufacturer protocol. Fluid flux split control Since the optimal working of the device depends on the fluid flux through the top channel and the membrane, it is important to reproducibly achieve the same fluid field conditions in order to compare different devices. In Figure d, the flow rates through top and bottom channels scale linearly with applied pressure difference. Moreover, the ratio of flow rates in the top and bottom channels is constant, governed by the high resistance outputs. The calibration and model are further described below.

Fig. Sa, b shows the lumped resister model for device operation. It reduces the percentage permeation flux variations and quantify the performance of the device reproducibly with the addition of large resistive tubings (r t =50 µm) at the top and bottom channels helped short out any inherent variations in the commercially available membranes and insured constant permeation flux along the length of the membrane. The model was able to accurately predict the fluid split between the top and the bottom channels as a function of the sample input pressure when the tubing resistances were approximately ten times the fluidic resistance of the membrane and the channels in a sample with dilute suspension of particles (φ o < 0.). The ratio of the resistances on the top and bottom tubings determine the fluid split, whereas the actual resistances of the tubings determine the sample flow rate through the top and bottom outlets of the channels. The different component fluidic resistances of the device are shown in Table S.. The channel resistances were calculated using Eqn. S. The tubing resistances were calculated using Eqn. S. R ch = μl ch wh (S.) R tubing = 8μL t πr t The membrane resistances were calculated using Eqn S. (S.) R m = 8μL p. (S.) πr p n Based on the above resistances, the theoretical flow rates in the top channel and membrane are given by R Q t = b P (S.) Q b = (R in (R b +R t )+R b R t ) R t P (R in (R b +R t )+R b R t ) (S.5)

Where, If, R t = R ch,t + R ot,t R b = R m + R ch,b + R ot,b R ot,t > 0R ch,t, R ot,b > 0(R ch,b + R ot,b ) (S.6) (S.7) (S.8) Then, R t = R ot,t (S.9) R b = R ot,b (S.0) Qb Rt A = = Q + Q R + R (S.) t b t b The resistance values in Table S. show that the output tubings have resistance much greater (~0 times) than the fluidic resistance of the channel or the membrane. Under this condition, the resistance model can be simplified from Fig. Sa to Fig. Sb. The effect of the simplified model is to maintain a constant pressure difference along the length of the membrane and hence a constant uniform velocity of fluid flux at the wall. Additionally, the simplified model allows prediction of the fluid split and flow rates based on the lengths and therefore the resistances of the outlet tubings. Eqn. S.6S., define sample fluid flow rate through the top channel and the membrane depends on the absolute values of the top and bottom output tubing resistances, but the split depends on the ratios of the two. In the event when the outlet tubings are short in length, the flux through the top and the bottom channels varies greatly. A mean standard deviation of 0. ml/hr permeation flux through the membranes was measured due to porosity differences in the polycarbonate membranes. Inlet tubing R it (Length= 50 cm) Top Channel R ch,t Top Outlet tubing R ot,t (Length = 66 cm) Bottom Channel R ch,b Bottom outlet tubing R ot,b (Length = cm) Membrane R m (Average porosity ~ 0%, rp = 0. µm) 5

Fluidic Resistance.9x0.x0.6 x0.5x0 0.x0 0 Table S. Component resistances of the device. The tubing resistances are kept at a much higher resistance that the channel and the membrane resistances. Fluid Streamline and Particle Trajectory Calculations Equations [] and [] in the text for the fluid streamlines and particle trajectories are derived here. The coordinates x,y; pressure p, velocity u x and ratio of permeation flux to total flux A were nondimensionalized: According to the lubrication approximation,, BC s: (S.) The axial velocity profile in a microfluidic channel with solid walls is: (S.) The fluid mass balance across an elemental section in a microfluidic device with a porous bottom surface is given by relating the average fluid velocity along the length of the channel to the fluid permeating through the membrane, Integrating along the length of the channel, Therefore, In its nondimensional form, (S.) (S.5) (S.6) (S.7) 6

The transverse fluid velocity field, can be obtained from the continuity equation (S.8) Integrating eqn. S.8,, BC: (S.9) (S.0) In nondimensionalized form, (S.) Velocity profiles for a microfluidic channel with solid walls can be obtained by setting v w ~0. The fluid streamlines in the rectangular channel with a porous bottom is therefore given by, Y o Yo Y Y = (S.) + AX Cell trajectories in a dilute suspension Faxen's law provides a general relationship between force on a spherical cell (F), its velocity (u p ) and the unperturbed fluid velocity (u o ) field far from the particle center. To determine how the cell trajectory is affected by the fluid streamlines, the x and y component of Faxen's first law for a nonbuoyant cell (density difference Δρ=0.00 g/cm ) were calculated: (S.) (S.) where R c = radius of the cell (5 µm). The effect of cell radius on streamline trajectory is negligible for R c < 0µm. Therefore higher order R c terms in eqn. S. and eqn. S. can be neglected and the Faxen s first law can be rewritten as: (S.5) 7

The particle trajectory is thus given by, (S.6) (S.7) where B = R c g ρ/9µ 0 ~ µm/s, is a constant sedimentation velocity for a particle of radius R c = 5 µm and density difference ρ ~ 0.00 g/cm (with respect to the solution). The cell trajectory in the microfluidic channel can be obtained by setting v w ~ 0 in eqn S.7. Fig. S. Percentage of cells convected to a porous capture surface scales linearly with the percentage permeation flux. Each data point corresponds to measurements on 5 independent devices, with pore size r p =00 nm. 8

Comparison of Measured Cell Surface Velocity with Hydrodynamic Model The hydrodynamics of a particle moving near a solid surface due to a shear field were previously treated theoretically by Goldman et al. Chem. Eng. Sci., 65660, (967). Based on the total flow rate through the channels, there should be a shear stress of 5 dyn/cm at the entrance. Assuming a particlesurface separation of 50 nm, the initial cell surface velocity is expected to be u c,0 = 000 µm/s. This value is incorporated into a phenomenological equation based on equation []: u c (x) ~ u c,0 ( Ax / L). As shown in Fig. S, the measured velocities are consistent with the hydrodynamic model at A = 50%. However, the measured values are significantly slower those predicted from the model and increasingly deviate at higher permeation rates. This discrepancy arises from the porosity of the surface, which is not accounted for in the Goldman model. The slowdown accounts from an additional suction force that causes temporary pauses in cell motion. Fig S. Comparison of measured cell surface velocity (markers), bestfit linear regression (solid lines) and hydrodynamic model of Goldman et al (dotted lines). Measured values are in agreement with model for A = 50%, but are consistently slower at larger permeation. 9

Table S Permeation (A) Distance along the channel (cm) Shear stress (dyn/cm ) Hydrodynamic velocity* (µm/s) Experimentally measured rolling velocity (µm/s) 50% 0 5..8..5 000 880 760 60 500 85 ± 7 76 ± 6 60 ± 9 60% 0 5..5.8 000 80 700 560 00 686 ± 56 89 ± 6 88 ± 70% 0 5....5 000 80 660 80 00 58 ± 7 8 ± 5 8 ± 80% 0 5 000 800 600 00 00 0 ± 0 ± 5 0 0 Table S. Comparison of cell surface velocity on a solid flat surface and a porous surface. *Hydrodynamic velocity for unencumbered particles on a flat surface using Goldman et. al. [] at a particle separation distance of 50 nm, a representative bond length for EpCAM antigen/antibody. Measured cell velocities are the average and standard deviation of at least 0 cells per condition. 0

Optimizing Experimental Conditions to Maximize Capture Efficiency and Selectivity Fig S5. State diagram showing the boundaries where x cr = 0 on the surface of the channel for different percentage permeations (A) and initial cell volume fraction (φ o ). The critical distance x cr = 0 is reached when the volume fraction of the particles on the porous surface reaches φ w = φ max = 0.6