HANDHELD GAS ANALYZER DELTA 65

Similar documents
EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Automatic titrators, TitroMatic

473-SHX Dew Point Mirror

MEASURING INSTRUMENTS LEAKAGE AND PRESSURE

Air velocity & IAQ measuring instruments

Air velocity & IAQ measuring instruments

Petrochemical. Transformer Oil Gas Analysis - TOGA

473 Dew Point Hygrometer

Metso Concentration Measurement 3300

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Gaseous CEMS technology

Impedance relay and protection assemblies

473 Dew Point Hygrometer

610,- KERN ADB. Analytical balances. Quick-Finder Analytical balances. Large glass draught shield with 3 sliding doors

One-hand ph/temperature measuring instrument

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Infrared Hand-Held Thermometers

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

PG-100 HANDY MANOMETER COPAL ELECTRONICS FEATURES MODEL NUMBER DESIGNATION P G G P. marking Compatible with EMC directive

Wöhler DP 700 Leakage Tester

Non contact temperature measurement

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:


3. Analytical measurement and testing Timing/Clocks-Climate measurement/hygrometer

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Intuitive air velocity and IAQ.

ebro has expanded its range of measuring instruments in the food area even further: ebro Data Logger Family EBI 20

InfraRed Thermometer with Laser Pointer

SwemaMan 7 Operating instructions vers 1.13 MB_CW

MEASURING INSTRUMENTS FLUE GAS ANALYSIS

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

CapaciTorr HV 200 HIGHLIGHTS

Total station LEICA TPS

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code

UV3000. Accurate, precise, and portable ambient gas point analyzer

Ion-Chamber Survey Meter OD-02

3URGXFWLQIRUPDWLRQ 5HVHUYDWLRQRISURSHUW\ULJKWV

HD32.2 WBGT Index HD32.3 WBGT-PMV. [ GB ] - WBGT index. - PMV index and PPD

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

INFRARED THERMOMETER Model : TM-959

AW/AHW Professional Weighing Scale. User Manual

Operating Instructions for Digital Manometer. Model: MAN-SD

Acceleration/Velocity/Displacement VIBRATION METER

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

GW Professional Weighing Scale. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGW

Cantilever enhanced tunable diode laser photoacoustic spectroscopy in gas purity measurement case study: acetylene in ethylene

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

New Instruments from GRIMM

HD32.2 WBGT Index HD 32.2 INSTRUMENT FOR THE ANALYSIS OF THE WBGT INDEX

CapaciTorr HV Pumps. making innovation happen,together

OXEA - Online Elemental Analyzer

Single cam type. Double cam type. Grip force N. Type Model/size Stroke Screw type straight style. Screw type tee style

No HOT WIRE ANEMOMETER MODEL SK-27V. SPECIFICATIONS Measurement object : Clean air at normal pressure and humidity

Dual laser + type K thermometer INFRARED THERMOMETER

ED 701 General Industry Pressure Transmitter


Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Atomic Absorption Spectrometer ZEEnit P series

Pressure transmitters for industrial applications MBS 32 and MBS 33

Product Description and Specification

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry

MEASURE WITH INTELLIGENCE!

Mini Environmental Quality Meter

WEATHER STATION FOR SOLAR FARM MONITORING

CEO LETTER. - Rolf Ludwig

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

PRODUCTS FROM THE MANUFACTURER

450W/650W/1000W Modular Power

PYCKO SCIENTIFIC LIMITED

Edgetech Instruments Inc.

Minimum (-31) every 10 s -35 (-31)

RADEAGLE. Next Generation Radioisotope Identification Device. Detection and Identification: Fast, Accurate and Easy

Slide 1. Slide 2. Slide 3. Choosing and Using the Best Sensor Technologies for Marine Chemistry Applications

Bright Advance Corporation

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

Infrared Hand-Held Thermometers

Heat stress index. Dewpoint. pressure. altitude

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Pressure Display Controller

Analog - Digital multimeters

ph/redox Measurement CPM 280

novaa 800 D Atomic Absorption Spectrometer

Thermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

2100TR Liquid Scintillation Counter

Protein Sequencer PPSQ-31A / 33A C297-E055B

Moisture Analyzers.

UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability

Transcription:

MBUSTION ANALYZER HANDHELD GAS ANALYZER DELTA 65 2 with H2 comp. and others Data storage S Infrared interface for high speed printer Battery (NiMh)and mains operation Integrated rechargeable NiMh batteries Light weight Oil light, natural gas, coke oven gas, blast furn gas, propane, butane, coal, others on rerquest. 0... 21 % (H 2 -compensation) Draft/stack draft - 50... + 50 hpa 2 Losses Efficiency (Condensation) Excess air / 2 ratio ppm, mg/m 3 /... % 0... 99,9 % 0... 100 % (120%) 1,............ C( F) Operation time IR Printer Interface Display TÜV By RgG 283 VDI 4206-1 DELTA 65 is a handheld gas analyzer for continuous analysis of different gases in a wide range of applications of flue gas analysis low high ver y high 2 S H 2 S T E CH N I CA L S P E CI F I CAT I ON Operating temperature Storage temperature DELTA 65 - Series Complete set with transport case and enough space for more accessories. (W x H x D) Wei ght, unit only We ight, complete 100/240 Vac LCD, 4-lines + 5... + 45 C - 20... + 60 C 74 x 145 x 35 mm approx. 500 g approx. 940 g F L U E G A S A N A LY Z E R 2 NDIR SORS N 7 SE HANDHELD MULTIGAS ANALYZER OPTIMA 7 WITH sors: ) W New Sen (IR-Bench sor) Sen 0% (EC 0-2 2 500 ppm 0 low Clenched achievement on the narrowest space. For up to 7 sensors sensor protection: programmable limits and sensor purge 2 Rechargeable battery or mains power operation low x Super bright, coloured 3,5" TFT display with backlight and zoom function Tightness check Bluetooth interface (option) IR printer interface Ergonomic design TÜV By RgG 280 VDI 4206-1 T E CHN I CA L SP E CI F I CAT I ON Natural gas, liquid gas, oil light, pellets, biodiesel, others on request. 0... 21,0 Vol.-% 0... 20,0 Vol.-% high 2 S H 2S 0... 50 ppm, overload up to 500 ppm Temp. AIR 0... 650 C (SS),0... 1.100 C (Inconel) Temp. GAS 0... 100 C Diff. Press/stack draft -100...+100 hpa (dependent on fuel) 0... 2 max. 2 C Losses 0... 99,9 % Efficiency 0... 120 % Measured values mg/nm 3 referenced to, as 2 mg/kwh, x as mg/nm 3 02 C02 IR Bench (H2-comp.) GENERAL SPECIFICATIONS Operating temperature + 5... + 45 C max 95% humidity, non condensing Storage temperature - 20... + 50 C Power supply High energy Lithium-Ion battery for 15 h operation or NiMh battery for 6 hours operation external: 100... 240 Vac power supply approx. 750 g Dimensions 110 x 225 x 52 mm

2 x F L U E G A S A N A L Y Z E R PORTABLE ANALYZER VA 2000 L i g h t, r u g g e d d e s i g n i n a l u m i n i u m f r a m e d c a s e. M e e t s a w i d e r a n g e o f r e q u i r e m e n t s. TÜV By, RgG 252 TÜV VA 2000 F E x t e n s i v e s t a n d a r d e q u i p m e n t, r e a d y t o m e a s u r e U p g r a d e a b l e t o a H i g h E n d U n i t t h a n k s t o m o d u l a r h a r d - a n d s o f t w a r e - c o n c e p t R o b u s t m a t e r i a l s a n d e l e c t r o n i c m o n i - t o r i n g o f i m p o r t a n t f u n c t i o n s p r o v i d e a h i g h l e v e l o f a v a i - l a b i l i t y F o r u p t o 4 s e n s o r s S u i t a b l e f o r p e l l e t h e a t i n g s y s t e m s T E C H N I C A L S P E C I F I C AT I O N Oil light, natural gas, coke oven gas, blast furn gas, propane, butane, coal, others on request. (H 2-compensation) high (option) very high (option) (option) 2 (option) S (option) Diff. press./stack draft 0... ± 100 hpa Soot test Bacharach filter paper method 2... % Losses 0... 99,9 % Efficiency (Condensation) 0... 100 % (120%) Excess air 1,... / 2 ratio... X/ ppm, mg/m 3 /...... C Battery capacity (not with soot measurement) 115/230 Vac AUX 0... 10 V / 4... 20 ma connector Built-in printer PC Interfaces RS 232/USB/SD/Bluetooth graphic (W x H x D) 420 x 300 x 240 mm approx. 8,5 kg (including aluminium framed case) O 2 2 2 S E M I - C O N T I N U O U S E M I S S I O N M O N I T O R I N G Simultaneous measurement of up to 9 gases (6 electrochemical and 3 NDIR)! S e m i - C o n t i n u o u s c o n t r o l m e a s u r e m e n t s o f a l l i n d u s t r i a l f i r i n g s The VARIOplus Industrial combines NDIR-technology and electrochemical sensors. This combination ensures a maximum of precise measurement results. Due to its compact design and low weight the VARIOplus Industrial is easy to use at difficult sites. A modern, rugged all metal case design, with robust, shockproof PU side covers as well as a new, super-fast line printer with easy paper loading mechanism makes this new unit the number one choice for mobile emission monitoring. VARIOplus INDUSTRIAL I m p o r t a n t f e a t u r e s Intergrated, electrical Peltiercooler unit Automatic condensate pump Heated or unheated gas sampling line Automatic print- and data storage program RS 485 Interface for additional AUX connectors SD Card with data logger up to 1 GB 8 Analog outputs 4... 20 ma VARIOplus SE without electric gas cooler unit and heated gas sampling line NDIR 3-gases infrared bench (# 61447) 2 0... 3 % / 20 % CH 4 NDIR 3-gases infrared bench (# 58118) 0... 3 % / 10 % 2 0... 3 % / 30 % CH 4 0... 1 % / 3 % NDIR 3-gases infrared bench (# 58986) 0... 3 % / 10 % 2 0... 3 % / 30 % C 3H 8 0... 2.000 / 5.000 ppm (H2 -compensation) high (option) very high (option) (option) 2 (option) (option) up to 650 /1.700 C 100... 240 Vac/12 Vdc LCD, graphic (W x H x D) 438 x 290 x 152 mm approx. 6,5 kg (without transport case)

2 x F L U E G A S A N A L Y Z E R PORTABLE ANALYZER VA 2000 L i g h t, r u g g e d d e s i g n i n a l u m i n i u m f r a m e d c a s e. M e e t s a w i d e r a n g e o f r e q u i r e m e n t s. TÜV By, RgG 252 TÜV VA 2000 F E x t e n s i v e s t a n d a r d e q u i p m e n t, r e a d y t o m e a s u r e U p g r a d e a b l e t o a H i g h E n d U n i t t h a n k s t o m o d u l a r h a r d - a n d s o f t w a r e - c o n c e p t R o b u s t m a t e r i a l s a n d e l e c t r o n i c m o n i - t o r i n g o f i m p o r t a n t f u n c t i o n s p r o v i d e a h i g h l e v e l o f a v a i - l a b i l i t y F o r u p t o 4 s e n s o r s S u i t a b l e f o r p e l l e t h e a t i n g s y s t e m s T E C H N I C A L S P E C I F I C AT I O N Oil light, natural gas, coke oven gas, blast furn gas, propane, butane, coal, others on request. (H 2-compensation) high (option) very high (option) (option) 2 (option) S (option) Diff. press./stack draft 0... ± 100 hpa Soot test Bacharach filter paper method 2... % Losses 0... 99,9 % Efficiency (Condensation) 0... 100 % (120%) Excess air 1,... / 2 ratio... X/ ppm, mg/m 3 /...... C Battery capacity (not with soot measurement) 115/230 Vac AUX 0... 10 V / 4... 20 ma connector Built-in printer PC Interfaces RS 232/USB/SD/Bluetooth graphic (W x H x D) 420 x 300 x 240 mm approx. 8,5 kg (including aluminium framed case) O 2 2 2 S E M I - C O N T I N U O U S E M I S S I O N M O N I T O R I N G Simultaneous measurement of up to 9 gases (6 electrochemical and 3 NDIR)! S e m i - C o n t i n u o u s c o n t r o l m e a s u r e m e n t s o f a l l i n d u s t r i a l f i r i n g s The VARIOplus Industrial combines NDIR-technology and electrochemical sensors. This combination ensures a maximum of precise measurement results. Due to its compact design and low weight the VARIOplus Industrial is easy to use at difficult sites. A modern, rugged all metal case design, with robust, shockproof PU side covers as well as a new, super-fast line printer with easy paper loading mechanism makes this new unit the number one choice for mobile emission monitoring. VARIOplus INDUSTRIAL I m p o r t a n t f e a t u r e s Intergrated, electrical Peltiercooler unit Automatic condensate pump Heated or unheated gas sampling line Automatic print- and data storage program RS 485 Interface for additional AUX connectors SD Card with data logger up to 1 GB 8 Analog outputs 4... 20 ma VARIOplus SE without electric gas cooler unit and heated gas sampling line NDIR 3-gases infrared bench (# 61447) 2 0... 3 % / 20 % CH 4 NDIR 3-gases infrared bench (# 58118) 0... 3 % / 10 % 2 0... 3 % / 30 % CH 4 0... 1 % / 3 % NDIR 3-gases infrared bench (# 58986) 0... 3 % / 10 % 2 0... 3 % / 30 % C 3H 8 0... 2.000 / 5.000 ppm (H2 -compensation) high (option) very high (option) (option) 2 (option) (option) up to 650 /1.700 C 100... 240 Vac/12 Vdc LCD, graphic (W x H x D) 438 x 290 x 152 mm approx. 6,5 kg (without transport case)

D I G I TA L M A N O M E T E R DIGITAL PRECISION MAMETER DM 9200 P r e s s u r e, n e g a t i v e p r e s s u r e, d i f f e r e n t i a l p r e s s u r e a n d f l o w v e l o c i t y h P a m b a r b a r p s i m m / H g i n c h / H g c m / H2O i n c h / H2O ABS transport case Microprocessor controlled precision manometer with electronic long-term stable pressure sensor. Therefore highly precise measurements are possible within the very sensitive low pressure range (Pascal). The indication automatically switches between Pascal (Pa) and Hectopascal (hpa). More scale units are selectable, e.g. mm/hg, cm/h2 O, inch/h 2O. The microprocessor automatically controls this, also the temperature compensation. ABS case with rear solenoid plate. M E A S U R I N G R A N G E S ± 7 5 h P a ( m b a r ) ± 1 3 0 h P a ( m b a r ) ± 3 5 0 h P a ( m b a r ) ± 1. 0 0 0 h P a ( m b a r ) Zero point adjustment via software no more manual adjustment using a screwdriver Automatic temperature compensation via micro processor Two ranges with autorange function Infrared interface for printer Measuring data memory for 20 measurements Minimum/maximum value memor y Programmable average value calculation R A N G E S ± 75 h P a ( m b a r ) 1. Ranges ± 99,5 Pa (Pascal) Resolution 0,5 Pa, accuracy ± 2,0 % 2. Ranges ± 75,0 hpa (mbar) Resolution 0,01 hpa, accuracy ± 0,75 % R A N G E S ± 1 3 0 h P a ( m b a r ) 1. Ranges ± 20 hpa (Pascal) Resolution 0,1 Pa, accuracy ± 0,5 % 2. Ranges ± 130,0 hpa (mbar) R A N G E S ± 3 5 0 h P a ( m b a r ) 1. Ranges ± 100 hpa (mbar) Resolution 1,0 hpa, accuracy ± 0,5 % 2. Ranges ± 350,0 hpa (mbar) R A N G E S ± 1.000 hpa (mbar) 1. Ranges ± 199,9 hpa (mbar) 2. Ranges ± 1.000 hpa (mbar) Resolution 1 hpa, accuracy ± 0,5 % Power supply Operating time Various pitot tubes for measurement of gas flow velocity 2 x batteries, LR 6 AA approx. 1.000 h Operating temperature - 5... + 45 C (W x H x D) 84 x 139 x 24 mm approx. 250 g G A S D E T E C T O R L E A K A G E D E T E C T I O N -DETECTOR 0... 2 0. 0 0 0 p p m -DETECTOR 0... 3 0 0 p p m GAS LEAKAGE DETECTION Gas detector for combustible gases (ambient air) ppm, %, %LEL Gas detector for carbon monoxide (ambient air)

NTINUOUS EMISSION MONITORING S TAT I O N A R Y M E A S U R I N G T E C H N I Q U E F O R I N D U S T R I A L A P P L I C AT I O N S. Emission monitoring of all combustion facilities 2 2 H 2S H2 C DUST VELOCITY SWG 300-1 Multicomponent M Monitoring System based on an extractive sample methode using dispersive infrared technology or electrochemical cells. This combination ensures a maximum of precise measurement results and an attractive price. Zr Reliable measurement of: OMS 420 Z r O X Y G E N M E A S U R E M E N T, e MEASUREMENT DM 401 DUST MONITORING SWG 200-1 - C O - C - N O - C XH Y C H 4 - H 2 - H 2 S P R O C E S S G A S A N A LY Z E R W-62317GB-K4-XX-031-HWH 2 S 2 Distributor: