MBUSTION ANALYZER HANDHELD GAS ANALYZER DELTA 65 2 with H2 comp. and others Data storage S Infrared interface for high speed printer Battery (NiMh)and mains operation Integrated rechargeable NiMh batteries Light weight Oil light, natural gas, coke oven gas, blast furn gas, propane, butane, coal, others on rerquest. 0... 21 % (H 2 -compensation) Draft/stack draft - 50... + 50 hpa 2 Losses Efficiency (Condensation) Excess air / 2 ratio ppm, mg/m 3 /... % 0... 99,9 % 0... 100 % (120%) 1,............ C( F) Operation time IR Printer Interface Display TÜV By RgG 283 VDI 4206-1 DELTA 65 is a handheld gas analyzer for continuous analysis of different gases in a wide range of applications of flue gas analysis low high ver y high 2 S H 2 S T E CH N I CA L S P E CI F I CAT I ON Operating temperature Storage temperature DELTA 65 - Series Complete set with transport case and enough space for more accessories. (W x H x D) Wei ght, unit only We ight, complete 100/240 Vac LCD, 4-lines + 5... + 45 C - 20... + 60 C 74 x 145 x 35 mm approx. 500 g approx. 940 g F L U E G A S A N A LY Z E R 2 NDIR SORS N 7 SE HANDHELD MULTIGAS ANALYZER OPTIMA 7 WITH sors: ) W New Sen (IR-Bench sor) Sen 0% (EC 0-2 2 500 ppm 0 low Clenched achievement on the narrowest space. For up to 7 sensors sensor protection: programmable limits and sensor purge 2 Rechargeable battery or mains power operation low x Super bright, coloured 3,5" TFT display with backlight and zoom function Tightness check Bluetooth interface (option) IR printer interface Ergonomic design TÜV By RgG 280 VDI 4206-1 T E CHN I CA L SP E CI F I CAT I ON Natural gas, liquid gas, oil light, pellets, biodiesel, others on request. 0... 21,0 Vol.-% 0... 20,0 Vol.-% high 2 S H 2S 0... 50 ppm, overload up to 500 ppm Temp. AIR 0... 650 C (SS),0... 1.100 C (Inconel) Temp. GAS 0... 100 C Diff. Press/stack draft -100...+100 hpa (dependent on fuel) 0... 2 max. 2 C Losses 0... 99,9 % Efficiency 0... 120 % Measured values mg/nm 3 referenced to, as 2 mg/kwh, x as mg/nm 3 02 C02 IR Bench (H2-comp.) GENERAL SPECIFICATIONS Operating temperature + 5... + 45 C max 95% humidity, non condensing Storage temperature - 20... + 50 C Power supply High energy Lithium-Ion battery for 15 h operation or NiMh battery for 6 hours operation external: 100... 240 Vac power supply approx. 750 g Dimensions 110 x 225 x 52 mm
2 x F L U E G A S A N A L Y Z E R PORTABLE ANALYZER VA 2000 L i g h t, r u g g e d d e s i g n i n a l u m i n i u m f r a m e d c a s e. M e e t s a w i d e r a n g e o f r e q u i r e m e n t s. TÜV By, RgG 252 TÜV VA 2000 F E x t e n s i v e s t a n d a r d e q u i p m e n t, r e a d y t o m e a s u r e U p g r a d e a b l e t o a H i g h E n d U n i t t h a n k s t o m o d u l a r h a r d - a n d s o f t w a r e - c o n c e p t R o b u s t m a t e r i a l s a n d e l e c t r o n i c m o n i - t o r i n g o f i m p o r t a n t f u n c t i o n s p r o v i d e a h i g h l e v e l o f a v a i - l a b i l i t y F o r u p t o 4 s e n s o r s S u i t a b l e f o r p e l l e t h e a t i n g s y s t e m s T E C H N I C A L S P E C I F I C AT I O N Oil light, natural gas, coke oven gas, blast furn gas, propane, butane, coal, others on request. (H 2-compensation) high (option) very high (option) (option) 2 (option) S (option) Diff. press./stack draft 0... ± 100 hpa Soot test Bacharach filter paper method 2... % Losses 0... 99,9 % Efficiency (Condensation) 0... 100 % (120%) Excess air 1,... / 2 ratio... X/ ppm, mg/m 3 /...... C Battery capacity (not with soot measurement) 115/230 Vac AUX 0... 10 V / 4... 20 ma connector Built-in printer PC Interfaces RS 232/USB/SD/Bluetooth graphic (W x H x D) 420 x 300 x 240 mm approx. 8,5 kg (including aluminium framed case) O 2 2 2 S E M I - C O N T I N U O U S E M I S S I O N M O N I T O R I N G Simultaneous measurement of up to 9 gases (6 electrochemical and 3 NDIR)! S e m i - C o n t i n u o u s c o n t r o l m e a s u r e m e n t s o f a l l i n d u s t r i a l f i r i n g s The VARIOplus Industrial combines NDIR-technology and electrochemical sensors. This combination ensures a maximum of precise measurement results. Due to its compact design and low weight the VARIOplus Industrial is easy to use at difficult sites. A modern, rugged all metal case design, with robust, shockproof PU side covers as well as a new, super-fast line printer with easy paper loading mechanism makes this new unit the number one choice for mobile emission monitoring. VARIOplus INDUSTRIAL I m p o r t a n t f e a t u r e s Intergrated, electrical Peltiercooler unit Automatic condensate pump Heated or unheated gas sampling line Automatic print- and data storage program RS 485 Interface for additional AUX connectors SD Card with data logger up to 1 GB 8 Analog outputs 4... 20 ma VARIOplus SE without electric gas cooler unit and heated gas sampling line NDIR 3-gases infrared bench (# 61447) 2 0... 3 % / 20 % CH 4 NDIR 3-gases infrared bench (# 58118) 0... 3 % / 10 % 2 0... 3 % / 30 % CH 4 0... 1 % / 3 % NDIR 3-gases infrared bench (# 58986) 0... 3 % / 10 % 2 0... 3 % / 30 % C 3H 8 0... 2.000 / 5.000 ppm (H2 -compensation) high (option) very high (option) (option) 2 (option) (option) up to 650 /1.700 C 100... 240 Vac/12 Vdc LCD, graphic (W x H x D) 438 x 290 x 152 mm approx. 6,5 kg (without transport case)
2 x F L U E G A S A N A L Y Z E R PORTABLE ANALYZER VA 2000 L i g h t, r u g g e d d e s i g n i n a l u m i n i u m f r a m e d c a s e. M e e t s a w i d e r a n g e o f r e q u i r e m e n t s. TÜV By, RgG 252 TÜV VA 2000 F E x t e n s i v e s t a n d a r d e q u i p m e n t, r e a d y t o m e a s u r e U p g r a d e a b l e t o a H i g h E n d U n i t t h a n k s t o m o d u l a r h a r d - a n d s o f t w a r e - c o n c e p t R o b u s t m a t e r i a l s a n d e l e c t r o n i c m o n i - t o r i n g o f i m p o r t a n t f u n c t i o n s p r o v i d e a h i g h l e v e l o f a v a i - l a b i l i t y F o r u p t o 4 s e n s o r s S u i t a b l e f o r p e l l e t h e a t i n g s y s t e m s T E C H N I C A L S P E C I F I C AT I O N Oil light, natural gas, coke oven gas, blast furn gas, propane, butane, coal, others on request. (H 2-compensation) high (option) very high (option) (option) 2 (option) S (option) Diff. press./stack draft 0... ± 100 hpa Soot test Bacharach filter paper method 2... % Losses 0... 99,9 % Efficiency (Condensation) 0... 100 % (120%) Excess air 1,... / 2 ratio... X/ ppm, mg/m 3 /...... C Battery capacity (not with soot measurement) 115/230 Vac AUX 0... 10 V / 4... 20 ma connector Built-in printer PC Interfaces RS 232/USB/SD/Bluetooth graphic (W x H x D) 420 x 300 x 240 mm approx. 8,5 kg (including aluminium framed case) O 2 2 2 S E M I - C O N T I N U O U S E M I S S I O N M O N I T O R I N G Simultaneous measurement of up to 9 gases (6 electrochemical and 3 NDIR)! S e m i - C o n t i n u o u s c o n t r o l m e a s u r e m e n t s o f a l l i n d u s t r i a l f i r i n g s The VARIOplus Industrial combines NDIR-technology and electrochemical sensors. This combination ensures a maximum of precise measurement results. Due to its compact design and low weight the VARIOplus Industrial is easy to use at difficult sites. A modern, rugged all metal case design, with robust, shockproof PU side covers as well as a new, super-fast line printer with easy paper loading mechanism makes this new unit the number one choice for mobile emission monitoring. VARIOplus INDUSTRIAL I m p o r t a n t f e a t u r e s Intergrated, electrical Peltiercooler unit Automatic condensate pump Heated or unheated gas sampling line Automatic print- and data storage program RS 485 Interface for additional AUX connectors SD Card with data logger up to 1 GB 8 Analog outputs 4... 20 ma VARIOplus SE without electric gas cooler unit and heated gas sampling line NDIR 3-gases infrared bench (# 61447) 2 0... 3 % / 20 % CH 4 NDIR 3-gases infrared bench (# 58118) 0... 3 % / 10 % 2 0... 3 % / 30 % CH 4 0... 1 % / 3 % NDIR 3-gases infrared bench (# 58986) 0... 3 % / 10 % 2 0... 3 % / 30 % C 3H 8 0... 2.000 / 5.000 ppm (H2 -compensation) high (option) very high (option) (option) 2 (option) (option) up to 650 /1.700 C 100... 240 Vac/12 Vdc LCD, graphic (W x H x D) 438 x 290 x 152 mm approx. 6,5 kg (without transport case)
D I G I TA L M A N O M E T E R DIGITAL PRECISION MAMETER DM 9200 P r e s s u r e, n e g a t i v e p r e s s u r e, d i f f e r e n t i a l p r e s s u r e a n d f l o w v e l o c i t y h P a m b a r b a r p s i m m / H g i n c h / H g c m / H2O i n c h / H2O ABS transport case Microprocessor controlled precision manometer with electronic long-term stable pressure sensor. Therefore highly precise measurements are possible within the very sensitive low pressure range (Pascal). The indication automatically switches between Pascal (Pa) and Hectopascal (hpa). More scale units are selectable, e.g. mm/hg, cm/h2 O, inch/h 2O. The microprocessor automatically controls this, also the temperature compensation. ABS case with rear solenoid plate. M E A S U R I N G R A N G E S ± 7 5 h P a ( m b a r ) ± 1 3 0 h P a ( m b a r ) ± 3 5 0 h P a ( m b a r ) ± 1. 0 0 0 h P a ( m b a r ) Zero point adjustment via software no more manual adjustment using a screwdriver Automatic temperature compensation via micro processor Two ranges with autorange function Infrared interface for printer Measuring data memory for 20 measurements Minimum/maximum value memor y Programmable average value calculation R A N G E S ± 75 h P a ( m b a r ) 1. Ranges ± 99,5 Pa (Pascal) Resolution 0,5 Pa, accuracy ± 2,0 % 2. Ranges ± 75,0 hpa (mbar) Resolution 0,01 hpa, accuracy ± 0,75 % R A N G E S ± 1 3 0 h P a ( m b a r ) 1. Ranges ± 20 hpa (Pascal) Resolution 0,1 Pa, accuracy ± 0,5 % 2. Ranges ± 130,0 hpa (mbar) R A N G E S ± 3 5 0 h P a ( m b a r ) 1. Ranges ± 100 hpa (mbar) Resolution 1,0 hpa, accuracy ± 0,5 % 2. Ranges ± 350,0 hpa (mbar) R A N G E S ± 1.000 hpa (mbar) 1. Ranges ± 199,9 hpa (mbar) 2. Ranges ± 1.000 hpa (mbar) Resolution 1 hpa, accuracy ± 0,5 % Power supply Operating time Various pitot tubes for measurement of gas flow velocity 2 x batteries, LR 6 AA approx. 1.000 h Operating temperature - 5... + 45 C (W x H x D) 84 x 139 x 24 mm approx. 250 g G A S D E T E C T O R L E A K A G E D E T E C T I O N -DETECTOR 0... 2 0. 0 0 0 p p m -DETECTOR 0... 3 0 0 p p m GAS LEAKAGE DETECTION Gas detector for combustible gases (ambient air) ppm, %, %LEL Gas detector for carbon monoxide (ambient air)
NTINUOUS EMISSION MONITORING S TAT I O N A R Y M E A S U R I N G T E C H N I Q U E F O R I N D U S T R I A L A P P L I C AT I O N S. Emission monitoring of all combustion facilities 2 2 H 2S H2 C DUST VELOCITY SWG 300-1 Multicomponent M Monitoring System based on an extractive sample methode using dispersive infrared technology or electrochemical cells. This combination ensures a maximum of precise measurement results and an attractive price. Zr Reliable measurement of: OMS 420 Z r O X Y G E N M E A S U R E M E N T, e MEASUREMENT DM 401 DUST MONITORING SWG 200-1 - C O - C - N O - C XH Y C H 4 - H 2 - H 2 S P R O C E S S G A S A N A LY Z E R W-62317GB-K4-XX-031-HWH 2 S 2 Distributor: