EXCLUSION HIGH PERFORMANCE LIQUID CHROMATOGRAPHY ANALYSIS OF A CELLULOSE ACETATE-AMMONIUM NITRATE GAS GENERATOR PROPELLANT

Similar documents
High Performance Liquid Chromatography

High Performance Liquid Chromatography

High Pressure/Performance Liquid Chromatography (HPLC)

High Performance Liquid Chromatography

Determination of Polymer Modifier in Asphalt

Determination of Caffeine by HPLC

LUMEFANTRINUM LUMEFANTRINE

Headspace Technology for GC and GC/MS: Features, benefits & applications

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*

CHAPTER - 3 ANALYTICAL PROFILE. 3.1 Estimation of Drug in Pharmaceutical Formulation Estimation of Drugs

S2. INTRODUCTION TO ULTRA-VIOLET / VISIBLE SPECTROSCOPY

Gel Permeation Chromatography - GPC

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

INTRODUCTION The fundamental law of spectrophotometry is known as the Beer-Lambert Law or Beer s Law. It may be stated as: log(po/p) = A

Gas Chromatography. A schematic diagram of a gas chromatograph

Open Column Chromatography, GC, TLC, and HPLC

Determination of Gallic acid from their Methanolic Extract of Punica granatum By HPLC Method

Size Exclusion Chromatography: Method Development

Chemistry Gas Chromatography: Separation of Volatile Organics

H 3 CO H 3 CO S CH 3

CHAPTER 6 GAS CHROMATOGRAPHY

ARTEMETHER AND LUMEFANTRINE TABLETS: Final text for addition to The International Pharmacopoeia (July 2008)

Chromatography. Gas Chromatography

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies

penta-hilic UHPLC COLUMNS

Dissolution Test 5 was validated using a Zodiac C18 brand of L1 column. The typical retention time for atorvastatin is about min.

Experiment 1: Thin Layer Chromatography

ARTEMETHER AND LUMEFANTRINE ORAL SUSPENSION:Final text for addition to The International Pharmacopoeia (November 2008)

High Performance Liquid Chromatography

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

Waters GPC User Guide and Tutorial for Using the GPC in the Reynolds Research Group 2 nd Edition: April 2012

TECHNICAL TEMEPHOS. 1. Specification. Full specification WHO/SIT/19.R4 Revised 10 December Description

Chem 321 Name Answer Key D. Miller

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Polymer analysis by GPC-SEC. Technical Note. Introduction

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

FAQ's. 1 - Which column would be the most appropriate for my application?

Supporting Information

Gel Permeation Chromatography

MEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20

Principles of Gas- Chromatography (GC)

Gas Chromatography (Chapter 2 and 3 in The essence of chromatography)

Determination of Carbon Fibre-Polymer Interactions by Inverse Gas Chromatography

C18 Column. Care & Use Sheet

Luminescence transitions. Fluorescence spectroscopy

Optimizing GPC Separations

STUDY INITIATION DATE November 18, ANALYTICAL REPORT DATE December 12, AUTHORS Andrew Bosio Timothy D. Ballard

12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))

Instrumental Chemical Analysis

HPLC Praktikum Skript

INDIGOTINE. Disodium 3,3'-dioxo-[delta 2,2' -biindoline]-5,5'-disulfonate (principal component) (principal component)

TECHNICAL BRODIFACOUM

Physical Separations and Chromatography

METHANOLYSIS OF ACETAL

Cation Exchange HPLC Columns

The analysis of organic acid content of additives, premix, feed, and water.

FLUDEOXYGLUCOSE ( 18 F) INJECTION: Final text for addition to The International Pharmacopoeia (January 2009)

GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series. Contents

CHAPTER 19 PARACETAMOL + IBUPROFEN

LECTURE 2. Advanced Separation Science Techniques Present and Future Separation Tools

637. Thiamethoxam. HPLC method

Draft Method proposal: determination of glucoheptonic acid (HGA) in fertilizers.

An Introductions to Advanced GPC Solutions

CYCLOSERINE Final text for addition to The International Pharmacopoeia. (November 2008) CYCLOSERINUM CYCLOSERINE

HPLC Background Chem 250 F 2008 Page 1 of 24

Unexpected Peaks in Chromatograms - Are They Related Compounds, System Peaks or Contaminations? From the Diary of an HPLC Detective

Chromatography and Functional Group Analysis

This method describes the identification of the following prohibited colorants in cosmetic products:

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

USP 35 Official Monographs / Oxaliplatin 4143 DEFINITION

ADVANTAME. Not less than 97.0% and not more than 102.0% on the anhydrous basis. Sweetener, flavour enhancer

METHANOL REFERENCE SPECIFICATIONS

Downstream Processing Prof. Mukesh Doble Department Of Biotechnology Indian Institute of Technology, Madras. Lecture - 33 HPLC

How to use GPC/SEC for compositional analysis

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Phenogel. GPC/SEC Columns. Sample Elution. Technical Specifications 10 3 Å 10 6 Å

IMPCA METHANOL REFERENCE SPECIFICATIONS

The ph-responsive behaviour of aqueous solutions of poly(acrylic acid) is dependent on molar mass

Biochemistry. Biochemical Techniques HPLC

Report AFK0242/18 TABLE OF CONTENTS

Maximizing Performance Through GPC Column Selection

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

Minimizing Solvent Impact on Purification of Nitrogencontaining

PHYSICAL CONSTANTS: MELTING POINTS, BOILING POINTS, DENSITY

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Supporting Information For:

The Basis for Paper Chromatography

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Introduction to Chromatographic Separations

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

(Published in Journal of Liquid Chromatography 2(3): (1979) GEL PERMEATION CHROMATOGRAPHY OF POLYMERS FROM WOOD

8. Methods in Developing Mobile Phase Condition for C18 Column

Electronic Supplementary Information

Magnetic Iron Oxide Nanoparticles as Long Wavelength Photoinitiators for Free Radical Polymerization

Analytical Chemistry

Scott Anderson, Kathy Lawrence Dennis McCreary, Melissa Wilcox. Grace Davison Discovery Sciences

Transcription:

I SIZE EXCLUSION HIGH PERFORMANCE LIQUID CHROMATOGRAPHY ANALYSIS OF A CELLULOSE ACETATE-AMMONIUM NITRATE GAS GENERATOR PROPELLANT G. D. KNOWLTON and D. V. HAUN Talley Industries of Arizona, Mesa, Arizona ABSTRACT I 1 ^^ Problems involving mix-to-mix reproducibility for TAL-704 (a Talley Industries ^y of Arizona cellulose acetate-ammonium nitrate gas generator propellant), led to the rejection of several mixes. determine the causes of these problems. As a result, a series of studies were initiated to One such study involved semiquantitative, size exclusion high performance liquid chromatography (SEHPLC) analysis of TAL-704 and its components. mixes of TAL-704 showed that: ""vtv A comparison of SEHPLC results for acceptable versus failed Each mix sample analyzed exhibited five (5) characteristic peaks with correspondingly similar retention volumes (measured by both ultraviolet and refractive index detectors). These peaks were mainly attributed to cellulose acetate (5.51 ml), dinitrophenoxy-ethanol () dimer (8.62 ml), monomer (9.16 ml), (9.75 ml), and (10.11 ml) respectively^ in.% \.,L ( ~> ^-- K 4^-' The majority of the mix components analyzed contained one or more impurities in significant amounts (?1%)J ^4. Analyses of components, for which lot changes had been made between acceptable and failed mixes, revealed that both the and the contained proportionally greater quantities of impurities.^ While it was not possible to accurately quantitate the impurities due to the lack of pure material standards, the presence of these impurities in TAL-704 components could account for the lack of repeatability of propellant performance- This technique is presently under further development. INTRODUCTION T^tsj-e have been occasional problems associated with the mix-to-mix reproducibility for TAL-704 (a Talley Industries of Arizona cellulose acetate-ammonium nitrate gas generator propellant). Although the various facets of this problem 103

have been studied extensively, this paper describes only one phase of the investigative effort. The purpose of this study was to semiquantitatively analyze both acceptable and failed TAL-704 propellant mixes and their components, by means of size exclusion high performance liquid chromatography (SEHPLC), in an effort to detect any significant compositional differences between passed and failed mixes. EXPERIMENTAL Sample preparation The following solvents were tested to determine which would most completely dissolve TAL-704 propellant and each of its components: 1. Acetone 2. Acetonitrile 3. Carbon Tetrachloride 4. Cyclohexane 5. Hexane 6. Methylethylketone 7. Tetrahydrofuran (THF) 8. Toluene 9. Trichloroethylene Of the solvents tested, it was found that acetonitrile and THF produced the optimum results. Due to column/solvent compatibility considerations, THF was selected as the mobile phase, as well as the sample solvent for the majority of the analyses. TAL-704 propellant mixes Solutions of approximately 2% sample by weight were prepared by dissolving 2.0 grams propellant drillings in 100 ml THF. These solutions were vacuum filtered through a 1 inch bed of powdered 4A molecular sieve on a fine fritted glass crucible to remove undissolved carbon black and other suspended solids. It should be noted, that filtering through molecular sieve might unintentionally cause the partial or complete removal of certain propellant components other than the carbon black. Prior to injection into the liquid Chromatograph, the samples were filtered through a Fluoropore filter (Water's sample clarification kit) to remove all particles larger than 0.5 microns. TAL-704 propellant mix components Samples of each TAL-704 component (Table 1), except carbon black and ammonium nitrate, were dissolved in 100 ml THF in approximately the same proportions by weight as in the propellant mixes (weight used, based on 2.0 gram- propellant per 100 ml THF). Prior to liquid Chromatograph injection, these solutions were filtered through a Fluoropore filter. 104

, r 1.' f - ' ', ", I -. fjbjft3 T -V I "_ v ". I -i w-'wit-m u w 5 TABLE 1. TAL-704 Propellant Mix Components Component Formula Molecular Weight, g Ammonium Nitrate (AN) Acetyl TriethylCitrate () Cellulose Acetate (CA) Dinitrophenoxy-ethanol () NH NO, 4 3 C 14 H 22 0 8 ^^«le^^ C 8 H 8 N 2 0 6 Function in TAL-704 80.05 Oxidizer 318.4 Plasticizer 75,000 avg (polymer) 228.2 (monomer) Binder/fuel Burn catalyst Carbon Black C 12.1 Filler/opacifier Sodium Barbiturate NaC 4 H 3 N 2 0 3 150.1 Slope suppressor Toluene-2,4-diamine C 7 H 10 N 122.2 Acid scavenger 2 C 10 H 13 N0 163.2 Acid scavenger Ammonium oxalate C 2 0 4 H 8 N 2 124.1 Coolant Triethyl Cxtrate* (citroflex 2) * not in propellant mix Molecular weight standards C 12 H 20 O 7 276.3 Used to seal propellant to CA cup Molecular weight (MW) standards (Table 2) were prepared by dissolving 0.10 g of known molecular weight materials in 50 ml THF. In addition, a mixture con- taining 0.10 g of each MW standard in 200 ml THF was prepared and used to establish degree of separation between standards. Molecular weight resolution was found to decrease as molecular weight increased. Any solution which appeared to contain suspended particulate matter was filtered through a Fluoropore filter prior to injection. Injection volumes ranged from 1 to 20 microliters. TABLE 2. Compound Trichloroethylene l-chloro-2,4-dinitrobenzene Dithizone Phenolphthalein Thymolphthalein Molecular Weight Standards Molecular Elution Weight, g volume, ml 131.4 10.44 202.6 9.66 256.3 9.18 318.3 8.80 430.5 8.66 Waters Associates Polystyrene Standards: #26971 - lot 12C #25169 - lot 61110 #41984 - lot 50124 2,350 3,600 233,000 7.29 7.02 5.57 105

-' > '-' "- *- -- '- - - " " -" -" "-" - * "-J» _» "_ -_* "- ri* r-«. ~^ rj» '_ "_ " y r.» r.» -. r_» ; J*.' _ _ _ ^- _.,.- s \ s * * \ * - ; - * Molecular weight calibration curve Molecular weight standards ranged from 130 to 3600 g/mole. A calibration curve was prepared by plotting elution volume vs. MW on semi-log paper. Not included on the calibration curve was a 233,000 MW standard, which was run to determine elution volume of a totally excluded species. Size exclusion liquid chromatoqraphy Size exclusion high performance liquid chromatography was performed on a Waters Associates Series 200 liquid Chromatograph equipped with a Model 440 ultraviolet (UV) absorbance detector (254 run wavelength cell and photodetector assembly), a Model R401 differential refractometer, a U6K universal injector, a Model 6000A solvent delivery system, and a 30 cm x 7.8 mm Waters 500 A ^istyragel column (for separation of compounds in the 50 to 10,000 MW range). Results of all analyseswere recorded on a Perkin-Elmer Sigma I data processor/plotter interfaced with the Waters Chromatograph. Experimental parameters and instrument settings mobile phase - THF isocratic flow rate - 1.0 ml/min. column temperature - ambient system pressure - approx. 100 psi sample injection volume - 1 to 40 microliters UV detector sensitivity - 1.0 and 2.0 RI detector sensitivity - 16 X Sigma I method parameters data run time - 15 min. area sensitivity - 100 baseline sensitivity - 6 attenuation - 0 chart speed - 20 mm/min. Propellant acceptance tests TAL-704 mix 631 passed all phases of the three propellant acceptance tests (K motor test. Batch check motor test. Lot acceptance test). TAL-704 mix 628 failed the burn rate portion of the Batch check motor test at all pressures tested. RESULTS AND DISCUSSION Size exclusion high performance liquid chromatography (SEHPLC) analyses of TAL-704 mixes 628 (failed mix) and 631 (passed mix) were performed using both an ultraviolet (UV) absorption detector and a refractive index (RI) detector. The two, in series units, were used to assure the detection of all significant 106

vwim v"»-s components. The results of these analyses showed that each propellant mix exhibited five characteristic peaks with correspondingly identical elution volumes (Figures 1 and 2). ID u 0 in ß «s u w A. I I w Q H 10 11 12 ELUTION VOLUME, ml Fig. 1. TAL-704, Mix 631 - SEHPLC using UV detector These volumes ranged on an average from 5.51 ml to 10.11 ml for the UV detector, and from 5.55 ml to 10.81 ml for the RI detector (Table 3). Each TAL-704 component (Table 4), with the exception of carbon black and ammonium nitrate, was also analyzed by means of SEHPLC using either a UV or RI detector or both. By comparison of mix peak elution volumes to component peak elution volumes, each propellant peak was matched to one or more corresponding component peaks (Table 3). Thus, identification of the five characteristic propellant peaks was achieved. In addition, approximate molecular weight information was obtained for mix and component peaks (using UV detector only) by obtaining elution volume data for a series of molecular weight standards (130 to 360C MW range) and plotting a standard curve. This information was useful in differentiating component peaks from peaks in the analyses of the various mix components. 107 " --»L-.,.->-\-. (.-.»»-<*.-> i'.. '.. V. 1 i-* v-w _ * _.

*r»v'. r»\ i "i 'T'vn». L '.. i f «i..!. i l^1» T't 1»BW WVWl 11! 11 1'W^IWI^W^^HW^P^^»^ 0) 'S > H +J Ü n) u u w 2 i Q 6 7 8 ELUTION VOLUME, ml Fig. 2. TAL-704, Mix 631 - SEHPLC using RI detector UV detector A comparison of the average characteristic peak areas for the TAL-704 mixes in THF, as well as acetonitrile, showed a few minor differences between the failed and passed mixes (Table 3). In each case, a ratio of peak 3 to peak 2 showed that the area of peak 3 was slightly larger than the area of peak 2 for mix 631 (1.20:1.00), whereas for mix 628, the peak areas were almost identical (1.01:1.00). Based on the results of component analyses and considering factors such as detector sensitivity, sample size, signal attenuation and component concentration in the mix, it was determined that the differences observed are mainly due to variations in the monomer/dimer content of the dinitrophenoxyethanol () constituent. The fourth peak, which was identified as predominantly a, was approximately 1.5% greater in area for the failed mix than for the passed mix. While the increased amount of associated with the burn catalyst,, in mix 628, could be a contributing factor to that mix's failure of certain acceptance tests, it is not considered significant. Peaks 1 and 5, which were identified as cellulose acetate (CA) and respectively, were in all cases nearly invariable in area. Analysis of the various TAL-704 components showed that few were pure substances, and that several, for which a lot change had been made between passed and failed nix. For example, as previously stated, the peak was approximately 1.5% greater for the failed mix. Also, the displayed an shoulder for the failed mix, which was not present with the passed mix. Although 108, - ^,< 1 _- *_-. «_1 ^1 «L^ ^1 - *» - «- " ^~.!-" * -. tl~» -.»-T n-mttm 1*.-».-«^*- *--. A-i-a * * ' - "^ **', -^'«^J ^^T»

dv.tu/l? 1 ',, i- '. V. W «.^ _". «.IMATVTVKVK ttktrsx^-««tv ><-4 «"L «T* ITV n.»"_ «K < - k-_ w-..-.»(-.-.^ - v» j» * -. r "- -> "«T TABLE 3. SEHPLC Results For TAL-704 Propellant Mixes ITV DRTRCTOR Approx. *Approx. Elution Percent Molec. Sample, Peak Volume, Peak Weight, Mix No. No. ml Area g 628 631 628 631 1 5.56 5.51 <0.1 8.62 44.1 9.16 44.4 9.75 4.2 > 20,000 345 265 195 10.11 7.4 160 5.52 <0.1 8.62 40.9 9.17 49.1 9.75 2.7 10.11 7.3 2 8.68 23.2 3 9.23 45.6 4 9.82 10.9 10.81 8.6 5.54 12.3 8.73 16.0 9.23 49.8 9.81 14.4 10.80 7.5 > 20,000 345 265 195 160 RI DETECTOR 11.7 ** * From MW calibration curve ** No MW calibration curve run for RI Detector 109 PEAK IDENTIFICATION Major Minor Component Component(s) Cellulose Acetate dimer monomer cellulose acetate dimer monomer cellulose acetate dimer monomer cellulose acetate dimer monomer sodium barbiturate toluene-2,4~ diamine sodium barbiturate toluene-2,4- diamine

,-.-^^-.^^~-^.-,- T -,^^-;-r-^^--^-r--r-r.^»jl..» -w, w wl ^ wiwr"w'v"wfv IW I» ' J r y» ^!'.ll't M F HHI'Wl TABLE 4. SEHPLC Results For TAL-704 Mix Components Sample Mix Component Peak No. Elution Volume, ml Approx. % Peak Area MIX 628 MIX 631 Approx Molec. Wt., g. Elution Approx *Approx. Volume, % Peak Molec. ml Area Wt., g 1 8.62 45.7 345 8.62 45.2 345 2 9.16 52.3 265 9.16 53.7 265 3 9.74 2.0 195 9.72 3.1 200 Citroflex A2 1 9.16 57.6 265 No lot number change 2 9.75 42.4 195 No lot number change sh 9.62»10.0 205 - Sodium Barbiturate sh... 1 10.12»90.0 160 10.11 100.0 160 85.0 1 9.20* 260 2 11.36 15.0 82 265 Not run Cellulose Acetate 1 5.51 100.0 >20,000 5.52 100.0 >20,000 Toluene-2,4-diamine 1 9.71 100.0 200 No lot number change Ammonium Oxalate 1 9.24 250 No lot number change 76.4 sh 9.30* 245 2 11.39 23.6 81 No lot number change Citroflex 2 1 9.17 15.2 265 h-tt run 2 9.77 80.4 190 3 10.10 4.4 160 BI PBTECTQR 1 8.71 23.2 ** 8.68 23.9 ** 2 9.23 32.7 9.10 35.0 3 9.83 44.2 9.80 41.2 Citroflex A2 1 9.20 46.2 No lot number change 2 9.82 53,8 No lot number change 1 9.86 66.6 9.86 72.6 2 10.85 33.4 10.85 27.4 Citroflex 2 1 9.10 38.9 Not run 2 9.82 35.4 3 10.80 25.8 * From MW calibration curve ** No MW calibration curve run for RI Detector sh = shoulder 110

the Citroflex A2 (TAL-704 component) and Citroflex 2 (cellulose acetate cup/ propellant sealer) lot numbers were not changed from failed to passed mixes, SEHPLC analysis indicated that both materials contained significant amounts of impurities. In addition, the analyses of the sodium barbiturate and ammonium oxalate components also showed the presence of impurities as shoulders or as separate peaks. In all cases, the identification of a peak or shoulder as an was based on the magnitude of the peak and the approximate molecular weight it represented. RI detector To augment the SEHPLC-UV detector findings, a smiliar series of mix and component analyses were run utilizing a refractive index detector. The use of this second detector assured the detection of any major or minor components which do not absorb in the UV at 254 run. As with the UV detector, analyses of the propellant mixes again produced five characteristic peaks (figure 2); but with slightly larger elution volumes resulting from the downstream position of the RI detector relative to the UV detector. Also, because differences in refractive index are being measured, rather than UV absorption, peak area ratios are considerably different than those determined using the UV detector. The results of peak identification for the propellant mixes (Table 3), based on elution volume data for the various TAL-704 components, was the same as obtained using the UV detector, with the exception of peak 4. This peak, identified as predominantly a, was also attributed, in a small part, to a constituent not visible with the UV detector. The results for analyses using the RI detector confirm the findings obtained with the UV detector, in that the attributed to the third peak was found to be slightly greater for the failed mix than the passed mix. However, area analysis of peaks 2 and 3 indicated there was a 3:1 monomer:dimer ratio (ratio of peak 3 to peak 2 - Table 3) for the passed mix vs. a 2:1 monomer:dimer ratio for the failed mix. This was somewhat different than the results obtained with the UV detector. In addition, the presence of several impurities in the Citroflex A2 and Citroflex 2 was verified by means of the RI detector. CONCLUSIONS Due to the inavaliability of pure materials for standards, it was not possible to accurately quantitate the SEHPLC results presented here; however, by means of a two detector system, several potentially useful discoveries, regarding TAL-704 propellant and mix components, were made on the semi-quantitative and qualitative levels. 1. It was shown that there are one or more impurities present in the majority of the TAL-704 mix components analyzed. Ill

VT^,-T"".1 w.1 ^"1-WJT"~ -i^f V^i ^1 ' «M T r-j -^ I -H "'J l «v 7%i <-»T» rwi ' i 1^ ' 'wr» u «innn utw.^i i» % i"^',^ ' '^ T ^i Hi ^ i^m'ni' 1^ '^'^'' ^ ' 2. For at least two of the components ( and ), whose lot numbers differed between passed and failed mixes, there were proportionally greater quantities of impurities present with the failed mix. 3. A significant difference in the Monomer/Dimer ratio for the content suggests that preprocessing to control that ratio may improve reproducibility of formula characteristics. The results of this study clearly indicate that further analyses of TAL-704 and selected components are necessary; and that an effort should be made to identify, quantitate and control the impurities which may determine propellant performance. 112 fi.'jfrsi.' ". r.-.r.v> ".» v "> "> - r> :_.-_ - r.. >.>..>.-> '.» 1. \. i -. i«. 1 -. \ '_ > ". ) '. -. ^ V T «-'I»-T --